A Shelly reports one energy figure — aenergy.total, a lifetime counter in Wh
that never resets. Bambuddy had a single REST energy field and filed whatever
it found under "today", so the value never reset at midnight, and Yesterday
and Total stayed at zero: get_energy() simply never set those keys.
With `total` unpopulated, the hourly snapshot recorder skipped the plug, so
the Statistics page's energy figure was zero as well, not just the Settings
card.
Split the REST energy config in two: rest_energy_path still means "used
today", rest_energy_total_path means "lifetime counter". A Shelly has only
the latter; a Tasmota behind a REST bridge has both; sharing a URL costs one
fetch, not two.
Then derive Today and Yesterday from that counter using the snapshots we were
already taking: today = counter now - counter at the last local midnight;
yesterday = the gap between the two previous midnights. Local midnight, not
UTC — a UTC boundary rolls Today over at 02:00 in Berlin. The snapshot loop
now ticks on the local hour so a reading lands on the boundary instead of up
to an hour early. A counter that goes backwards (factory reset) reports
nothing rather than a negative.
Collateral, found while verifying on both engines: the smart-plug DateTime
columns are naive UTC but the code wrote aware datetimes into them. SQLite
drops the offset; asyncpg raises DataError. So on Postgres every snapshot
capture raised inside the loop's except, and every status poll raised on
last_checked — the whole subsystem was dead on the database we recommend for
multi-printer installs. All plug timestamps are naive UTC now.
Existing REST users with a cumulative path in the today field must move it to
the new lifetime field; the form and wiki now name which counter each wants.
Cam Wall had no URL — the only way in was the toggle on the Printers page,
so it could not be bookmarked, linked, or shown on a wall-mounted screen.
Add a standalone /camwall route. Signed in, it is the wall as it was. For a
TV or Pi with no login, it authenticates with a long-lived token in the URL.
A kiosk needs the printer list and per-printer status, both of which sit
behind PRINTERS_READ. Rather than widen camera_stream to cover GET /printers
— whose response carries serial_number and ip_address, which have no business
on a screen in a shared room — add a read-only feed at
GET /api/v1/camwall/printers that serves only what a tile draws, and gate it
on a new camwall token scope. The print filename is not served at all: a token
wall renders the compact overlay, so the part on the bed is never named.
The scope is separate rather than a widening: camera_stream tokens are already
in the wild, minted to hand out video, and must not gain the ability to
enumerate a fleet by name. camera_stream is refused by the feed; camwall
passes the stream gate so its own tiles fill.
Kiosk walls drop the settings popover and click-through entirely (not merely
hidden — a passive screen must carry no focusable control it cannot act on),
cap the overlay at compact, and poll rather than open a WebSocket. maxLive,
interval and status can be set from the URL, clamped to the popover's ranges.
Adds PHP to CURRENCY_SYMBOLS, which feeds both getCurrencySymbol() and the
Settings currency dropdown. Backend stores the code string and needs no change.
The reporter found what his P1S was doing, and it is in Bambu's P1 manual:
"P1S connected AMS drying functions may only be controlled from the P1S screen."
The firmware acks ams_filament_drying with result: success and then discards it,
which is why three commands on an idle printer left the AMS 2 Pro at dry_status 0.
No command can start a cycle on a P1, on any firmware, so don't offer one.
supports_drying() now excludes the P1 series outright, replacing the 01.08+ gate
carried since #292 — that version is when P1 firmware gained AMS 2 Pro support,
not remote drying, and it was never checked against a live P1. Both drying routes
refuse with a specific 400 instead of publishing a message the printer will drop;
queue and ambient auto-drying skip P1s via the same helper.
A new drying_screen_only flag keeps the control on the card, disabled, saying why
— a P1 owner needs to learn where to dry, not watch the button disappear. A cycle
started at the printer still shows with its countdown; only Stop goes away, since
a P1 ignores stop exactly as it ignores start.
Also corrects the wiki firmware matrix, which listed P1P/P1S as supported and
(separately) P2S/H2S/H2C as unsupported. 8 tests.
The Start Drying button gave no feedback at all and reported success on the
strength of the MQTT ack alone. On a P1S the firmware answers
ams_filament_drying with result=success and then silently declines, and
P1-family firmware never publishes dry_sf_reason — so the #971 reason guard
is inert there and the card just sat unchanged.
Both drying mutations now toast. The start toast claims only that the command
was sent, since that is all the ack proves; the amber countdown badge remains
the signal that a cycle is genuinely live. After a start, the card watches the
unit's dry_status/dry_time (straight from the info bitmask, updated on every
push); firmware reaches DryStatus 1 within seconds of a real start, so still
sitting at zero 30s later means the cycle never began. Bambuddy now says so
and names the two causes: AMS power adapter not connected, or the printer not
idle. Unlike the dry_sf_reason guard this is model-agnostic.
The Start Drying button gave no feedback at all and reported success on the
strength of the MQTT ack alone. On a P1S the firmware answers
ams_filament_drying with result=success and then silently declines, and
P1-family firmware never publishes dry_sf_reason — so the #971 reason guard
is inert there and the card just sat unchanged.
Both drying mutations now toast on success. After a start, the card watches
the unit's dry_status/dry_time (straight from the info bitmask, updated on
every push); firmware reaches DryStatus 1 within seconds of a real start, so
still sitting at zero 30s later means the cycle never began. Bambuddy now
says so and names the two causes: AMS power adapter not connected, or the
printer not idle. Unlike the dry_sf_reason guard this is model-agnostic.
A spool with no readable RFID was reported by the standard AMS with an empty
tray_type and state=9 — structurally identical to a truly-empty slot at the
tray level — so the AMS card rendered it "Empty" while Bambu Studio correctly
showed "?". The authoritative "a spool is physically here" signal is firmware's
AMS-level tray_exist_bits bitmask (what Studio uses), but Bambuddy inferred
emptiness from the per-tray state/tray_type. Confirmed from the reporter's
bundle: tray_exist_bits=f (all four slots present) with tray_is_bbl_bits=5
(only slots 0,2 Bambu) — the present-but-non-Bambu slots were the ones shown
Empty. Supersedes closed#1838.
apply_tray_exist_bits() already parses the bitmask to clear stale fields on
absent slots; it now also annotates each slot with an authoritative `exists`
bool, gated behind a new annotate_exists flag so only the printer-card path
sets it. The VP bridge leaves it off, so the `exists` key never reaches the
slicer wire format. `exists` flows through the AMSTray schema/serialization to
the frontend, where getEmptySlotKind() uses it: exists===true + no tray_type
-> "?" (present, unconfigured), exists===false -> "Empty", exists absent ->
the previous state=9/10 heuristic (AMS-HT and missing-bitmask paths unchanged).
H2D/X1C already reported present-unknown slots with a non-9 state and took the
"?" path; with the fix they reach it via `exists` and are unaffected.
P1-series printers have a MicroSD slot but no reachable control to enable
"Store sent files on external storage": current P1 firmware (through
01.10.00.00) never publishes support_save_remote_print_file_to_storage, so
the Bambu Studio toggle never renders, and the P1S has no screen — leaving
store_to_sdcard stuck False with no way for the user to change it. The
external_storage check reported a permanently-unresolvable fail.
Add NO_REMOTE_STORAGE_TOGGLE_MODELS (P1S, P1P) + has_remote_storage_toggle(),
kept distinct from the no-slot NO_EXTERNAL_STORAGE_MODELS. When a model has a
slot but no reachable toggle and the option is off, the check now emits skip
with params reason=unsupported_model rather than fail, and overall no longer
escalates. A P1S reporting the option on still passes. Model-scoped and
default-open, so X1/P2S/H2 (where the fail is actionable) are unaffected; if
a future firmware surfaces the capability, drop the model and it reactivates.
The frontend DiagnosticChecklist renders a reason-specific message variant
(external_storage.skip_unsupported_model) so P1 users see an accurate
explanation instead of the generic "needs a live MQTT connection" skip text.
The fix propagates to the support-bundle diagnostic snapshot automatically.
Chamber-image printers came up black on load and only recovered ~20 min
later. Two causes: (1) late fan-out subscribers got an empty queue and
waited for the next frame, so the browser never fired onLoad and the
stall-detector reconnect-looped, churning short-lived viewers; (2) the
churn reopened the port-6000 socket before the old one closed, so the
printer fed an orphaned socket until its TCP keepalive reaped it.
Prime late subscribers with the last pumped frame; make a replacement
broadcaster's pump wait for the predecessor's socket to close before
dialing (bounded 10s); require two consecutive stalled reads before the
frontend reconnects.
The README panel rendered full-width above the file grid, pushing model
files below the fold with no page scroll to get past it. On lg+ it now
docks as a fixed-width right-hand column beside the list (own full-height
scroll); on mobile it stacks on top and the page scrolls. Added a collapse
toggle (thin strip / slim bar + one-click reopen) with the choice persisted
to localStorage. New i18n keys readme.show/hide/label across 11 locales.
The Configure AMS Slot picker was hardwired to 0.4mm (nozzleDiameter
prop never passed from PrintersPage / SpoolBuddyAmsPage), so a 0.6
machine could only set 0.4 profiles on its trays. Resolve the real
installed nozzle per-AMS (ams_extruder_map on dual-nozzle) and pass it
in. Separately, nothing validated the sliced nozzle against the
installed one, so a mismatch reached the printer as a cryptic HMS
_8012 "Failed to get AMS mapping table". Add a fail-safe pre-dispatch
guard in _start_print that fails the item with an actionable message
before upload; no slice diameter or no reported nozzles = no-op.
LoginPage rendered the credentials form for an already-authenticated
session, so a direct visit to /login (browsers autocomplete the origin
to it) looked like "Remember Me" never worked despite a live token.
Read user/loading from the auth context and redirect to / once the
auth check settles, gated on the credentials step so the 2FA and
OIDC-callback branches keep their own navigation.
The 40x30 mm box label rendered its QR too densely for low-res thermal
printers — the modules bled together and wouldn't scan. Two causes: the QR
was 20% of inner width (~7.5 mm on the narrowest template, half of the
others) and used ERROR_CORRECT_M. Fix adaptively so all templates benefit:
give the roomy-layout QR a 12 mm minimum size (box_40x30 -> 12 mm, ~3.5
dots/module at 203 dpi) and switch label QRs to ERROR_CORRECT_L (same
payload, chunkier modules; a label needs no M-level recovery). Keep the
quiet-zone border at 2 — the size+L gains suffice without risking scans.
Also add a Monochrome (black & white printer) option to the label dialog:
drops the colour swatch (a useless grey block on B&W) and widens the text;
the hex-code line still carries the colour. Threaded through the renderer,
route, API client, and modal, with translations in all 11 locales.
The app was built dark-first, so hundreds of hardcoded Tailwind semantic
text/icon utilities at light shades (text-amber-400, text-blue-300, ...) had
no dark: variant. With darkMode:'class' they applied in light theme too,
producing washed-out text on pale tints and white cards — including the three
reported spots (AMS Drying banner, Archives no-3MF warning, debug-logging
banner). Give each a theme-aware pair: a darker readable shade in light theme
with the original pinned to dark:, so dark theme is unchanged. ~100 files.
The bambu-* CSS-variable palette (self-correcting) and the dark-only SpoolBuddy
kiosk are left untouched. Plain text-white is already theme-aware via the
existing index.css .text-white override, so it needed no changes.
The sponsor toast re-fired on every fresh browser session. The backend
owns the 14-day cooldown but only persists the anchor (last_shown_at) and
the seen-milestone record inside POST /sponsor-prompt/dismiss, and the hook
only called dismiss from the "View supporters" CTA onClick. A user who saw
the toast but never clicked the CTA persisted no state; the per-tab
sessionStorage guard hid the re-fire within one session, but every new
session re-checked against empty state and re-showed the same milestone.
Record the toast as shown the moment it renders (POST /dismiss right after
showPersistentToast) so display is what arms the cooldown. CTA click stays
optional and just navigates. Frontend-only; backend cooldown logic unchanged.
The sidebar-ordering refactor in #1673 accidentally dropped the
`notifications` entry from `defaultNavItems` and its
`notifications:user_email` permission mapping, but kept the advanced-auth
visibility gate that references that id. With no nav entry the id never
enters the render set, so the /notifications page (route, page, and API
all intact) became reachable only by typing the URL — users could no
longer opt in/out of their own print email notifications from the menu.
Restore both the defaultNavItems entry and the permission gate, matching
the permission the user-email-preferences API actually requires
(notifications:user_email, held by both default groups). Add comments so
the entry isn't dropped again in a future sidebar refactor.
PROJECTS_CREATE/UPDATE/DELETE were in _APIKEY_DENIED_PERMISSIONS with no
entry in _APIKEY_SCOPE_BY_PERMISSION, so every project mutation returned a
generic 403 for any API key regardless of granted permissions -- the same
regression class as archives (#1888) and library (#1832).
Add a per-key can_manage_projects scope. Project routes gate on plain
PROJECTS_* (no OWN/ALL split), so all three CRUD permissions map to the one
scope; membership edits (add-archives) gate on PROJECTS_UPDATE and are
covered. PROJECTS_READ is unchanged (already under can_read_status).
Column defaults TRUE for new keys; existing rows backfill to FALSE so the
upgrade never silently widens scope. Migration is BOOLEAN (SQLite + Postgres
safe), verified on fresh SQLite and Postgres 17. Bundled SpoolBuddy kiosk key
set to False. Settings API-key UI gets a Manage Projects toggle + Projects
badge; 11-locale i18n. RBAC scope matrix + drift guards extended.
After the GHSA-r2qv gate (b7d7c825), /api/v1/ws needs a token from
POST /api/v1/auth/ws-token (Permission.WEBSOCKET_CONNECT). When the mint
failed, useWebSocket swallowed the error, opened a tokenless socket, the
server closed it 4401, and ws.onclose rescheduled connect() every 3s -
an endless loop that hammered /auth/ws-token. The dominant trigger is a
validly-logged-in user whose group lacks WEBSOCKET_CONNECT (mint returns
403). A secondary leak: the unmount-triggered onclose could schedule a
post-unmount reconnect.
Classify the mint failure: 401 (JWT expired; request() already clears it
and dispatches auth:expired) or 403 (valid session, missing permission;
degrade to REST polling) now stop the hook - no tokenless socket, no
reconnect. A 4401 close is terminal. Network/5xx still reconnect. A
disposedRef set in cleanup before close() prevents the unmount-race
reconnect. Same 401/403 no-open guard applied to StreamOverlayPage.
Also surface a one-line hint under the WebSocket permission in the group
editor (all 11 locales) explaining that live updates need it and fall
back to polling without it - rather than auto-granting the permission,
which would partly undo the GHSA-r2qv gate.
On mount, AuthContext.checkAuthStatus restores the persisted "Remember Me"
token from localStorage and validates it via GET /auth/me. The catch around
that call cleared the token on ANY failure, not just a definitive 401
invalid-token — so a brief backend-not-ready or reverse-proxy hiccup during
page load (plausible right after a container restart, e.g. on Unraid) would
delete a still-valid token. Because the token was deleted, a reload couldn't
recover it and the user was bounced to the login screen.
Token validation now retries transient failures (up to 3 attempts with short
backoff) and only discards the token on a definitive 401 — which request()
already handles (clears the token and dispatches auth:expired). Transient /
5xx / network errors leave the persisted token intact so the session survives
a slow load. "Remember Me" stays client-storage only; it does not extend the
server-side JWT lifetime (session_max_hours, default 24h).
Adds AuthContext tests: transient /auth/me failure keeps the token, a
definitive 401 clears it, and a valid token loads the user. Rebuilt frontend
bundle.
DELETE /api/v1/archives/{id} rejected every API key with 403
"API keys cannot be used for administrative operations", regardless of
the print's owner or the key's scopes. ARCHIVES_DELETE_ALL/_OWN (and the
create/update variants) were on the denylist and absent from the scope
allowlist, so require_ownership_permission fell through to the generic
admin-denied 403 — the whole archive-management surface was unreachable
for API keys. Same regression class as the #1832 library/maintenance
carve-outs.
Add a can_manage_archives per-key scope: ARCHIVES_CREATE, ARCHIVES_
UPDATE_OWN/_ALL and ARCHIVES_DELETE_OWN/_ALL move from the denylist to
the allowlist under it (OWN and ALL fold into the same scope, matching
can_manage_library). ARCHIVES_PURGE stays admin-only — it drops the
print's Quick Stats contribution, mirroring LIBRARY_PURGE. Column
defaults TRUE for UI-created keys; existing rows backfill to FALSE so the
upgrade never silently widens scope. Bundled SpoolBuddy kiosk key stays
minimally scoped (False). Migration is dialect-agnostic and verified on
fresh SQLite and Postgres 17.
Adds the Settings API-key toggle + badge (11-locale i18n) and extends the
RBAC scope matrix to cover all five archive-management permissions.
Editing a queue item that was created with "Any of model X" left the
printer selection area completely blank — the assignmentMode was
initialised to 'model' from queueItem.target_model, but the three
model-mode props (onAssignmentModeChange, onTargetModelChange,
onTargetLocationChange) were gated behind !isEditing. That flipped
modelAssignmentAvailable to false in PrinterSelector and hid the mode
toggle, the model dropdown, AND the location filter; combined with the
assignmentMode === 'printer' gate on the printer list, the whole
selector rendered empty.
Users hit this whenever they queued something to "Any of model X" and
then wanted to change the target model / location — the only workaround
was delete + re-queue.
Fix: drop the !isEditing gate on all three PrinterSelector props. The
submit path already handles both flavours (target_model+target_location
with printer_id=null vs. printer_id with the target fields nulled), so
un-gating the UI just surfaces the machinery that was already there.
Edit is still only offered on pending items, so the mode-flip can't race
an in-flight dispatch.
Carve MAINTENANCE_CREATE/UPDATE/DELETE out of the admin denylist so
HA automations can log "cleaned nozzle" / reset a counter via API key
without granting broader printer control. Follows the same shape as
can_manage_library and can_manage_inventory: new column, allowlist
entry, UI checkbox, wiki row, RBAC test coverage.
Distinct backfill: these perms were EXPLICITLY denied for every API
key before this change (no existing integration relies on them), so
existing rows migrate to FALSE — no silent scope widening on upgrade.
New keys default to TRUE, matching the safe-on-by-default pattern.
Bundled SpoolBuddy kiosk key gets False explicitly (kiosk doesn't need it).
P1S has an enclosure door but no hall sensor for it; P1P has no
enclosure at all. Both models were rendering a permanent green
"Door Closed" chip driven by bit 23 of the stat field, which stays
0 forever on that firmware. Whitelist now covers only models that
actually ship with a door sensor: X1 family, X2D, P2S, and H2 family.
Corrected the matching stale comments in the PrinterStatus TS
interface (client.ts) and PrinterState dataclass (bambu_mqtt.py).
Backend parse left as-is — cheap and future-proof if Bambu ever
wires the P-series enclosure into a sensor.
PrintModal carried a useEffect that reset scheduleOptions.gcodeInjection
to false whenever mode === 'create' AND effectiveQuantity <= 1. The
comment claimed the checkbox only renders for quantity > 1, but the
actual render gate in ScheduleOptions is just hasGcodeSnippets — no
quantity check. So with snippets configured + quantity = 1 (the OP
scenario): user clicks the checkbox, React updates state to true,
the parent's useEffect immediately sees effectiveQuantity <= 1 and
resets to false, and the checkbox appears un-clickable. Edit-queue-
item mode worked because mode !== 'create' short-circuited the reset.
Drop the effectiveQuantity <= 1 clause from the reset. Keep the
!settings?.gcode_snippets half as the legitimate cleanup for the
"admin removes all snippets while modal is open" case. The scheduler
reads item.gcode_injection per queue item regardless of batch size,
so single prints can inject too.
New scheduler stage that heats the bed (and the chamber, on supported
printers) and holds at temperature before each queued print starts —
the heat-soak engineering filaments need for adhesion and warp
control. Bambuddy waits between FTP upload and start_print, so the
soak runs while the printer is otherwise idle. M191 is silently
ignored by Bambu firmware, so doing this at the orchestration layer
is the only place it works.
Resolution order at dispatch:
1. PrintQueueItem.preheat_override ∈ {inherit, on, off}.
'off' skips entirely; 'inherit' falls back to the global
preheat_enabled toggle; 'on' forces the stage even when the
global is off.
2. chamber_target = item.preheat_chamber_target_override
?? max(filament_map[normalize(t.tray_type)] for loaded slots)
?? 0.
Mixed PA+PLA picks PA's 50 (max-across-slots — PA's chamber
requirement is binding, PLA doesn't suffer being warm). PLA-only
derives 0 and skips the chamber phase automatically.
3. Three hardware tiers for chamber heat:
- Active chamber heater (H2C/H2D/H2D Pro/H2S/X2D/X1E) → M141 +
chamber-sensor wait
- Chamber sensor only (X1C/P2S) → no M141, passive bed-radiation
wait with hard max-wait cap
- No chamber sensor (P1S/P1P/A1/A1 Mini) → bed + soak timer only
4. Airduct flap (H2C/H2D/H2D Pro/H2S/X2D/P2S) auto-switches to
match the chamber target — heating mode for engineering
filaments, cooling mode for PLA. Bambu firmware does NOT
auto-switch the flap with M141, so without this an ABS print
on a previously-cooling flap fights the open exhaust, and a
PLA print on a previously-hot flap recirculates ABS heat.
Idempotent: only fires set_airduct_mode when current ≠ desired.
Settings → Workflow → Queue & Dispatch → Preheat & Heat Soak card:
master enable toggle (default off — disabled installs see no change),
per-filament chamber-target editor (replaces a single global int that
shipped in the first cut and couldn't serve PA + PLA in the same
config), preheat_max_wait_seconds, preheat_soak_seconds. The Print
Options panel in PrintModal gets a Preheat sub-section with the
tri-state Inherit/On/Off control and an optional chamber-target
override input.
DB migration: PrintQueueItem gains preheat_override VARCHAR(10)
DEFAULT 'inherit' and preheat_chamber_target_override INTEGER NULL.
Idempotent via _safe_execute. Existing rows behave exactly as before
the migration.
Best-effort throughout: printer drops, refused M141 or set_airduct,
missing bed temp, lost MQTT state mid-wait all log and return cleanly.
Normal upload + start path runs after this returns regardless.
The HMS error modal had three compounding bugs that surfaced when a
user forced a wrong-plate HMS (0500_8051) and tried to dispatch the
per-fault actions.
(1) IGNORE_RESUME did not ignore. Bambuddy redirected the action on
state=PAUSE to a plain `resume` command, citing a #1830 verdict that
BambuStudio's "err-bearing shape" was firmware-silently-rejected.
BambuStudio source disagrees: DeviceErrorDialog.cpp:600 dispatches
IGNORE_RESUME via command_hms_ignore, whose wire shape is
{command:"ignore", err:"<decimal>", param:"reserve", job_id:...}.
That's a distinct command from `resume` — the firmware suppresses
the next re-check AND auto-resumes in one operation. Plain resume
means "re-check normally", which is exactly why the wrong-plate
detection re-fired 1-2 s after the user clicked Ignore. The #1830
"err-bearing shape rejected" test almost certainly sent the err as
a hex shortcode; BambuStudio passes std::to_string(int m_error_code)
i.e. the DECIMAL form, which is what the firmware matches against.
(2) Action buttons read as inert badges. The button className used
`hover:${buttonHoverColor}` — a template-literal interpolation
Tailwind's JIT scanner can't see as a literal string, so the
per-severity hover utility never reached the compiled CSS. Same
bg/text color as the severity badge above and no border made it
read as another label. No disabled state and no spinner during the
2.5 s ack wait left clicks sitting silently inert.
(3) Ack-detection 502'd on legitimate ack. The route compared
(gcode_state, hms_errors-len) before vs after publish; wrong-plate
re-pause round-tripped both fields to their pre-publish values
inside the 2.5 s window → false 502 even though the firmware fully
ack'd. PROBLEM_SOLVED_RESUME working but IGNORE_RESUME 502'ing on
the same fault was the same race resolving differently.
Fixes:
bambu_mqtt.py — new hms_ignore_command() publishes the BambuStudio
shape; existing hms_ignore(persistent) renamed to hms_idle_ignore
(unchanged shape, used by NO_REMINDER_NEXT_TIME per
DeviceErrorDialog.cpp:588). Dispatch routes IGNORE_RESUME,
IGNORE_NO_REMINDER_NEXT_TIME, and DONT_REMIND_NEXT_TIME to
hms_ignore_command (BambuStudio routes all three to the same
command_hms_ignore — the "don't remind" half is the firmware's
job). NO_REMINDER_NEXT_TIME stays on hms_idle_ignore type=0. Hex →
decimal err conversion at the helper layer with a defensive
fallback. job_id=None → empty string (matches BambuStudio's
std::string default).
HMSErrorModal.tsx — getSeverityInfo loses the dead buttonHoverColor
field. Action button uses static
`bg-white/10 hover:bg-white/20 active:bg-white/30 text-white
border border-white/20`, wires
`disabled={!hasPermission||mutation.isPending}`, and renders
`<Loader2/>` only on the button whose (action,print_error) matches
mutation.variables.
printers.py — ack-detection probes `client._last_message_time`
(bumped on every MQTT push regardless of payload) rather than
diffing state fields. The pushall that follows every command
guarantees a fresh push lands inside the 2.5 s window on any
healthy printer; only firmware-silent-drop leaves the timestamp
untouched, which is the 502 path #1830 wanted.
Two compounding bugs let an H2C-bound filament land in slot 1 of an A1
slice silently. (1) `_slicer_rejection_message` discarded the actual CLI
diagnostic - `filament preset Generic PLA @BBL H2C (slot 1) is not
compatible with printer Bambu Lab A1 0.4 nozzle.` - when the sidecar's
headline error_string was Bambu Studio's catch-all
`The input preset file is invalid and can not be parsed.` placeholder.
The real reason was in the stdout `[error] run NNNN:` line, trimmed off
before reaching the SliceJob's error_detail. (2) `pickFilamentForSlot`
used a soft `-100` mismatch penalty rather than a hard skip, leaving
the "never auto-fill an incompatible preset while a compatible one
exists" contract implicit. The unused-slot substitution in
`substitute_unused_plate_filaments` then propagated whatever slot 1
held across every unused slot - one bad pick poisoned the array.
(1) Mine `[error] <msg>` (with or without `run NNNN:`) from the full
pre-trim response; substitute the placeholder, keep meaningful
headlines. (2) Partition candidates into compatible/unknown vs
mismatch; prefer compatible whenever the bucket is non-empty, fall
back to mismatch only on graceful-degrade. Picker helpers moved out
of `SliceModal.tsx` into `utils/slicePresetPicker.ts` so the modal
file stays component-only (react-refresh lint).
filterKnownHMSErrors and the modal-local copy gated visibility on
ERROR_DESCRIPTIONS membership. H2C 0500_809C carries IGNORE_RESUME /
PROBLEM_SOLVED_RESUME but is missing from the bundled 853-entry catalog,
so the entire error — pip, count, panel, action buttons — never rendered
even though backend captured + dispatched it correctly.
The gate isn't dead code: PrintersPageBucketing pins the post-cancel
0C00_001B junk-echo regression to it. Widen the predicate to keep
(cataloged) OR (actions.length > 0) so noise is still filtered out
while user-actionable faults always surface.
Replace the modal's inline filter with the shared helper so badge
counts and modal contents agree by construction. Fall back to
hmsErrors.unknownCode ("Unknown HMS code — see the Bambu Lab wiki
for details.") when the catalog has no entry. New key translated in
all 11 locales.
New bucketing test pins PAUSE + uncataloged-with-actions = error;
existing FAILED + uncataloged-without-actions = finished stays green.
Administrators system group sync
- Fresh installs already bootstrap with ALL_PERMISSIONS, so they always have
every permission. Upgrades previously only got what one-off backfill blocks
in seed_default_groups() explicitly listed (library:purge, archives:purge,
the OWN/ALL read-flag block, orca_cloud:auth, pipelines:*). Any Permission
enum member added without a matching block silently stayed missing on
existing admin rows. The most recent gap was printer_sensor_history:read
(Sensor History charts returned 403 for upgraded admins).
- seed_default_groups() now syncs Administrators to ALL_PERMISSIONS on every
startup: append every Permission value that isn't already on the row.
Additive only -- hand-added custom permissions are preserved.
- The pure-admin one-off backfills (library:purge / archives:purge block,
the OWN/ALL + orca_cloud:auth + legacy-read-flag block, the Administrators
branch of the pipeline backfill) are retired since the sync subsumes
them. Non-admin backfills (Operators / Viewers OWN-tier reads, Operators
orca_cloud:auth, pipelines for non-admin groups, makerworld:*, clear_plate
cross-group adders) are untouched.
- Tests: test_administrators_printer_sensor_history_read_backfilled
(regression for the reported gap),
test_administrators_sync_covers_every_current_permission (generic
invariant -- any future new permission lands on admin without needing
a one-off test), test_administrators_sync_is_additive_only (custom
permissions preserved). 12/12 backfill-migration + 102/102 broader
permission tests green; ruff clean.
Pipelines runs dashboard
- PipelineRunsPage.tsx: the Pipeline / Status / Target filter row's three
native <select> elements are replaced with a bambu-themed FilterDropdown
(button trigger, floating menu, optgroup-style headers for the Target
picker, hover + selected states with a check mark, closes on outside
click and Escape). Same value/onChange contract -- visual only.
- SlicerPipelinesPanel.tsx: wrap list?.pipelines ?? [] in useMemo so the
reference is stable when the data is stable. Fixes the
react-hooks/exhaustive-deps warning where the inline fallback returned
a fresh empty array every render, invalidating both downstream useMemo
caches (target-options + filtered-pipelines list).
PR A/B turned the slice modal's preset bundle into a one-click dispatch
with a pinned target printer. PR C closes the original issue: operators
type in a number of copies, Bambuddy slices once and distributes prints
across a fleet per the pipeline's chosen fanout strategy. A new dashboard
surfaces every run with filters, expandable per-copy status, cancel,
and retry-failed-copies. WS pushes keep everything live.
Backend
- copies field on POST /run, capped by new pipeline_max_copies setting
(default 50, hard cap 1000). PipelineRun.parent_run_id chains retries.
- SlicerPipelineUpdate accepts target_kind (specific_printer /
printer_class), target_model_class, fanout_strategy.
- Eligibility matcher branches: class-targeting enumerates matching
Printer rows, runs per-printer checks via a status_lookup closure,
returns printer_reports[]. New issue kinds: no_class_matches,
class_not_set.
- _pick_assignments distributes copies per strategy:
- max_parallel: target_model set, printer_id None — scheduler picks
- round_robin: copy i → eligible[i % N], fixed printer_id
- fill_one_first: all copies pinned to eligible[0]
All three reuse the slice-once path through slice_dispatch.enqueue.
- New routes:
- GET /pipeline-runs (paginated, filterable by pipeline + status)
- POST /pipeline-runs/{id}/retry-failed (creates child run with
copies = failed+cancelled count, parent_run_id set)
- Cancel cascades to all N queue entries (only pending/queued)
- _roll_up_run_status computes run-level status from per-job statuses;
introduces partial_failure for "some completed, some failed".
- ws_manager.broadcast_to_user emits pipeline_run_updated on every
state transition with the full materialised response.
Frontend
- Pipeline editor: target_kind radio + class picker (filtered to
installed models) + fanout-strategy radio. Read-only row shows
"X1C · Round robin" for class pipelines.
- RunWithPipelineModal: copies number input bounded by
settings.pipeline_max_copies. Accepts class-targeted pipelines.
- Settings → Workflow → Queue & Dispatch: new "Slicer Pipeline limits"
card with the max-copies input.
- New /pipelines/runs dashboard page (sidebar entry, gated on
pipelines:read). Two-filter dropdown, 25-per-page pagination, per-row
expandable to job list, Cancel + Retry-failed buttons.
- useWebSocket case for pipeline_run_updated invalidates both
pipeline-runs-all and pipeline-runs/{id} query keys.
Two real gaps from the PR B drop:
1. Run-with-pipeline only existed in the file manager. Operators who keep
working files in archives had to copy them to the library to use a
pipeline.
2. Triggering a slice via a pipeline produced a silent multi-second-to-
minute wait. The manual SliceModal flow shows the sticky
"Slicing X - Generating G-code 75%" persistent toast; the pipeline
path went through asyncio.create_task directly and never registered
with SliceJobTracker.
Archive entry point
- POST /slicer-pipelines/{id}/check-eligibility and /run accept
source_archive_id as an alternative to source_library_file_id (XOR,
enforced by Pydantic validator).
- PipelineRun.source_archive_id is a new nullable FK column with the
ALTER TABLE migration in run_migrations (idempotent via _safe_execute,
works on SQLite + Postgres).
- _resolve_source branches: archive path reads source_3mf_path with
fallback to file_path, mirroring routes/archives.py.
- ArchiveCard's context menu picks up a "Run with pipeline" item next to
Slice (only on source archives), gated on useSlicerApi + pipelines:run.
Slice (only on source archives), gated on useSlicerApi + pipelines:run.
- Path-safety: SEC-PATH-OK markers added at both LibraryFile.file_path
and archive.source_3mf_path join sites, citing the upload-time
validators.
Progress toast
- Pipeline orchestration is now the `run` callable of a
slice_dispatch.enqueue call — the same dispatcher SliceModal uses —
instead of a bare asyncio.create_task. The SliceJob lifecycle drives
the existing progress toast end to end with no separate notification
surface for pipeline runs.
- PipelineRun.slice_job_id is set before the 202 returns.
- RunWithPipelineModal calls useSliceJobTracker().trackJob() from
runMutation.onSuccess.
- RunWithPipelineModal source prop is now {kind, id, filename}
mirroring SliceModal.SliceSource; api.checkPipelineEligibility +
api.runPipeline take a discriminated-union source argument.
The SliceModal forces the user to pick four slots every time (printer /
process / filament(s) / bed type). For fleet production that's tedious
and error-prone. Pipelines let an operator save a named bundle and apply
it with one click on the next file.
PR A is bundle-and-management only. PR B adds single-target dispatch,
PR C adds multi-copy batch with capability-matched fanout. Future-PR
columns (target_kind / target_printer_id / target_model_class /
fanout_strategy) ship in this migration so PR B+ is code-only, not a
schema bump.
Backend
- New model SlicerPipeline + slicer_pipelines table; soft-delete via
is_deleted so PR B+ run history can still resolve metadata.
- Pydantic schemas reuse the existing PresetRef shape from
schemas/slicer.py.
- CRUD routes at /api/v1/slicer-pipelines/ — list (newest first by id
DESC), create (201), get-by-id, partial PUT, soft-delete (204).
- Three new permissions: PIPELINES_READ / PIPELINES_WRITE / PIPELINES_RUN.
Administrators + Operators get all three; Viewers get READ.
Backfill in seed_default_groups() so existing installs upgrade
cleanly. All three denied to API keys for now.
Frontend
- Settings → Workflow splits into two horizontal sub-tabs mirroring
the Authentication tab pattern: "Queue & Dispatch" (existing
Workflow content) and "Pipelines" (new). URL deep-link via
?tab=queue&sub=pipelines.
- SlicerPipelinesPanel — list, inline rename, delete, stale-preset
warning when a referenced preset no longer resolves.
- SliceModal gets "Apply pipeline ▾" + "Save as pipeline". Apply
fills all four slot states; the filament list right-pads from
current state so a pipeline with fewer entries than the current
source's slot count keeps the existing tail.
FTP push to the printer into the server-side scheduler tick. That
removed the browser-side upload the old XHR-progress modal listened
to — users only saw the queue item flip to "active" with no visibility
into the FTP push + the H2D/H2D Pro 80-210 s project_file digestion
window before the printer actually started.
Port the legacy bg-dispatch toast rendering from
0b43ac0d:frontend/src/contexts/ToastContext.tsx lines 510-650 back in
place verbatim — same DOM tree, same Tailwind classes, same
formatFileSize bytes line, same uppercase status chip, same collapse
chevron, same awaitingPrinter derivation, same auto-dismiss. The only
adapt is the event ingestion: a useEffect maps the four scheduler-side
WS events to the legacy DispatchToastJob shape.
The toast materializes when the FTP push to the printer ACTUALLY
STARTS (queue_item_uploading) — NOT on POST /queue. A draft that
fired at queue-add made the toast jump to "Dispatched" before any
upload had happened.
Four backend WS events drive it: uploading (carries printer_name +
total_bytes), upload_progress (throttled at 200 ms / 256 KB to match
legacy background_dispatch.py:614-615 1:1, first call always emits,
completion always emits; an _UploadProgressBridge bridges from the
FTP executor thread to the asyncio loop), acked (printer transitioned
out of pre_state), failed (with a reason key the toast looks up as
dispatchToast.failed.{reason}). No queue_item_dispatched event: the
legacy path kept status=processing from upload start until printer
ack, "Awaiting printer..." derives from upload_progress_pct >= 99.9
(legacy uploadDoneAwaitingPrinter trick).
Per-user routing: WS connect resolves the principal username to
User.id once and stashes it on websocket.state, so
ws_manager.broadcast_to_user filters O(connections). Auth-disabled
installs route user_id=None to all connections — matches the legacy
single-user behaviour. The watchdog receives created_by_id through a
new kwarg so the static method can still emit acked without
re-fetching the queue item.
The original #793 fix added the spool note as an HTML title= tooltip
on each picker button in AssignSpoolModal.tsx. title= only surfaces
on hover, which doesn't exist on touch devices — phone users tapping
a card just selected it, the note never appeared. Users who store
their tracking ID in the note field were blind on mobile (raised by
@EmcetPL on the closed issue).
Render the note as a small muted truncated line directly under the
weight on both the internal-inventory branch (line 436-ish) and the
Spoolman branch (line 510-ish): text-[10px] text-bambu-gray/70 mt-1
truncate, kept inside the truthy `&&` guard so empty notes don't add
a blank row. The existing title={spool.note} is preserved on the new
<p> so desktop hover and mobile long-press still surface the full
untruncated text for notes that overflow the truncate.
Mirrored across both inventory branches per the parity rule
(internal and Spoolman pickers stay shape-equal). No backend change,
no new state, no popover, no new touch target.
Three distinct bugs combined into one user-facing failure: clicking
Stop / Problem-solved-and-resume / Ignore-and-resume returned 200 OK
but the printer didn't act, modal stayed up, print stayed paused.
Verified by injecting candidate command shapes on device/<sn>/request
against a live H2D paused on a wrong-plate HMS (print_error=0x05008051).
(1) hms_resume / hms_stop dispatched the "err"-bearing shape that
BambuStudio doesn't actually send; Bambu firmware silently rejects it.
Both now send the plain shape ({"print":{"command":"<x>","param":"",
"sequence_id":"0"}}). PAUSE -> FAILED in 1.7s for stop, PAUSE -> RUNNING
in <2s for resume.
(2) IGNORE_RESUME mapped to idle_ignore, which is BambuStudio's
"dismiss a warning" command and only works for non-pause warnings.
hms_ignore now branches on state.state == "PAUSE": paused -> plain
resume; not-paused -> idle_ignore with the full-length err.
(3) 64-bit hms[]-array faults were truncated to a non-matching err.
short_code in _parse_status discarded 32 of the 64 identifier bits, so
the firmware didn't match it to the active fault. HMSError.full_code
now carries the canonical hex identifier (16 chars for hms[] faults,
8 chars for print_error faults). Catalog lookup tries 16-char first,
falls back to 8-char. HmsActionBody.print_error pattern relaxed to
^[0-9A-Fa-f]{8}([0-9A-Fa-f]{8})?$.
(4) execute_hms_action returned publish-success as success, masking
every silent-rejection bug above as 200 OK. Route now snapshots
(state.state, len(state.hms_errors)) before dispatch, awaits
HMS_ACTION_ACK_WAIT_SECONDS (default 2.5s, module-level so tests
override), and returns 502 with "Printer did not acknowledge HMS
action within 2.5s" if state didn't move.
On dual-nozzle printers (H2C/H2D), the External card stacked a
separate "Ext-L" / "Ext-R" caption below each tray to mark which
extruder it fed. That caption appeared on the External card only,
making the bottom row of the printer card's AMS panel visibly
taller than the row above it.
Fix: the L/R distinction now lives inside the slot's colour circle
in place of the numeric index, and the bottom caption is removed.
FilamentSlotCircle's slotNumber prop is widened to `number | string`
to carry the letter. Single-nozzle externals (one tray, no L/R
distinction) keep the numeric "1".
The Ext-L / Ext-R strings still drive the slot's "location" label
in the filament hover card, so detail context is preserved.
streams when one viewer closes
1) Offline tiles now show OFF (not LIVE)
CameraWall.modeByPrinter assigned 'live' to any visible printer
without considering status.connected, so a disconnected X1C wasted
a live-budget slot AND rendered the red LIVE chip on top of the
WifiOff placeholder. Disconnected printers now map to 'paused' and
don't decrement liveBudget — the existing WifiOff + Off chip
rendering takes over.
2) /camera/stop no longer kills other viewers' streams
The cam-wall tile, EmbeddedCameraViewer, and the /camera/:id popup
all subscribe to the same fan-out broadcaster for a printer.
/camera/stop used to unconditionally shutdown_broadcaster() + kill
every ffmpeg process for the printer, so closing the embedded viewer
while the cam-wall tile of the same printer was live force-killed
the source the tile was pulling from — the tile's <img> errored.
New get_subscriber_count(key) accessor in camera_fanout.py exposes
the broadcaster's subscriber list length. /camera/stop now reads
that first; when >= 1 subscriber is still attached, return
{stopped: 0, skipped: true} and leave the broadcaster + ffmpeg
processes alone. The leaving viewer's HTTP teardown still runs the
natural iter_subscriber.finally -> unsubscribe path, so its slot is
released; the broadcaster keeps serving the other viewers. Single-
viewer close still hits the immediate force-teardown (count is 0).
Three issues from the post-merge audit of the unified-dispatch PR, all
pre-existed on dev but became more impactful once every print routes
through the queue:
1. Start/Stop ownership gates. /queue/{id}/stop required QUEUE_UPDATE_ALL
(admin-only) -- operators saw the Stop button in the queue UI but got
403 on click. /queue/{id}/start required QUEUE_UPDATE_OWN with no
ownership check -- _OWN holders could start anyone's queue items via
direct API. Both routes now use require_ownership_permission, mirroring
/cancel. Stop is strict (rejects unowned items for _OWN); start preserves
#1670's VP-import flow where _OWN can start NULL-owner items and claim
ownership at click-time. Frontend QueuePage Start/Stop buttons flip
from printers:control to canModify('queue', 'update', created_by_id).
2. TOCTOU race on insert_position. Concurrent ASAP inserts to the same
scope both computed MAX(position) from before the other committed; in
an empty scope, both inserted at position=1 (duplicate). Wraps the
read+update in a transaction-scoped Postgres pg_advisory_xact_lock
keyed on the printer_id. Different printers don't contend. SQLite
serializes writes implicitly so the path is no-op there. Dialect is
checked against the live session binding, not the is_sqlite() helper,
because the test fixture overrides get_db to SQLite while
settings.database_url still points at Postgres.
3. /reorder duplicate-position validator. POST /queue/reorder set position
from the payload in a loop with no uniqueness validation -- a buggy
drag-drop client could leave the queue with ambiguous ordering (the
scheduler's ORDER BY (printer_id, position) ties break by row order).
New model_validator on PrintQueueReorder rejects duplicates at the
schema layer with 422 + "Duplicate positions in reorder request: [N, ...]".
Adds a global local_login_enabled setting plus a per-provider
is_autologin flag on OIDCProvider so operators who run their own SSO
enabled, or if the calling admin has no UserOIDCLink — either would
lock everyone out. App-layer invariant: at most one provider can carry
is_autologin; setting it on one clears it on every other.
/auth/advanced-auth/status surfaces both new fields so the LoginPage
decides UI in one query. The env-var bypass flips the reported
local_login_enabled back to true so the SPA matches what the route
will accept.
New view toggle on the Printers page renders a responsive grid of live
camera tiles instead of printer cards. Reuses the existing /camera/stream
fan-out so the backend ffmpeg pipeline is unchanged.
To stay sustainable on the median Pi 4 install, only on-screen tiles run
live, and only up to a per-user cap (default 4). Other visible tiles
fall back to periodic /camera/snapshot polling (default 8s). Off-screen
tiles pause entirely. Tiles POST /camera/stop on unmount and on
leave-live so the backend transcoder slot is released the same way
EmbeddedCameraViewer does it.
CameraTile is a 3-mode leaf (live / snapshot / paused) with a single
<img> and an onError no-signal fallback. CameraWall is the scheduler:
IntersectionObserver tracks visibility, a stable walker over the sorted
printer list assigns live slots first-N-visible to avoid LRU churn. Same
['printerStatus', id] React Query cache the cards already populate, so
flipping between Cards and Cam Wall is instant.
Tile click honours the existing Settings camera_view_mode preference
(window vs embedded). Both wall settings are per-user localStorage
(camWallMaxLive, camWallSnapshotSec) — a Pi 4 user and a NUC user want
different caps.
Bambu's per-tick AMS push carries only the dry_time countdown — the
filament name and target temperature the user chose are never echoed on
the wire. The AMS card had no source of truth for them and rendered the
bare "Drying · 11h 35m left". The badge now shows
"Drying · PETG @ 65°C · 11h 35m left", matching the cycle the user
actually started.
BambuMQTTClient caches {ams_id: {filament, temp}} on send_drying_command
(mode=1), clears on mode=0 and on the dry_time falling edge to 0 — the
same per-AMS edge detector that drives the smart-plug-after-drying
callback. PrinterManager.get_drying_targets exposes it, the four
printer_state_to_dict call sites thread it through, AMS schema gains
dry_target_temp + dry_filament, and routes/printers.py builds the same
fields into the manually-constructed AMSUnit response.
When no cached target exists (drying started in a previous backend
lifetime, or initiated outside Bambuddy), the badge falls back to the
first loaded tray's tray_type + RFID-recommended drying_temp — the
heuristic the popover already uses to seed defaults.
i18n: printers.drying.targetSummary = "{{filament}} @ {{temp}}°C" in
all 11 locales. Parity check 5356 leaves per locale.
Note: a user reported the H2D's own physical display still labels the
cycle by the loaded tray's filament (e.g. "PLA" instead of the
Bambuddy-requested "PETG"). The wire payload is correct end-to-end —
journalctl shows filament: "PETG" sent and result: success ACKed — and
the badge in Bambuddy's own UI now reflects what we actually sent,
independent of the firmware's display choice.
Continue Auto-Drying while a print is running on capable hardware.
New Settings > Print Queue > "Continue drying while printing" toggle
(default OFF). Extends _check_auto_drying in print_scheduler.py to
evaluate running printers when supports_drying_while_printing(model,
firmware) returns true. Strict allowlist verified per Bambu wiki
release notes for "Print While Drying" / "printing while filament is
drying": H2D 01.03.00.00+, H2C/H2S/P2S/H2D Pro 01.02.00.00+, X2D/A2L
01.01.00.00+, X1C 01.11.02.00+. P1*, A1, A1 Mini, X1 (non-C), X1E
intentionally excluded. Mid-print drying temperature is capped at
max(40, preset_temp - 5) to protect spools from heat damage inside the
hot enclosure during a print, matching Bambu's own "lower drying
temperature during printing" guidance.
Rotate-spool toggle in the drying popover is now disabled when any tray
in the targeted AMS has filament threaded into the feed tube
(tray.state === 11). The whole AMS rotates as one mechanism, so a
single loaded slot locks the entire unit. Previously the toggle was
always clickable and the firmware rejected with dry_sf_reason=[3]
(ConsumableAtAmsOutlet) after the click. The first cut keyed on the
printer-level tray_now but missed the H2D's typical post-print state
where tray_now resets to 255 while filament stays in the tube — the
per-tray state field reports it correctly. Submission also clamps
rotateTray off so a stale-true state from a previous AMS can't leak
through.
Backend: supports_drying_while_printing in printer_manager.py covers
display names and internal SSDP/MQTT codes (O1D, O1E/O2D, O1C/O1C2,
O1S, N6, BL-P001, N7, N9). New print_drying_enabled boolean in
settings schema. Frontend: toggle on SettingsPage, gate + clamp on
PrintersPage drying popover using existing amsData cache. i18n: 3 new
keys x 11 locales, no English fallback. Tests: 7 cases on the gate
matrix (TestSupportsDryingWhilePrinting), 4 cases on the scheduler
mid-print path (TestMidPrintDrying), 9 cases on the rotate gate state
transitions. Full backend pytest -n 30 green (4251/4251), ruff clean,
frontend npm run build clean, i18n parity 5355 leaves per locale.
fix(db): order filament_shopping_list color_name ALTER after CREATE
PR #1814 added ALTER TABLE filament_shopping_list ADD COLUMN color_name
before the CREATE TABLE IF NOT EXISTS for that table. On fresh installs
the ALTER hit "no such table" — not in _safe_execute's swallow list —
and aborted run_migrations, breaking every migration test that starts
from a fresh DB. Moved the ALTER to after the CREATE on both SQLite and
Postgres branches; the CREATE already declares color_name, so this is
purely the upgrade path and "duplicate column name" on re-runs is
swallowed.
Single failure on a printer with require_previous_success queue items
permanently skipped every downstream + every new item — the
_check_previous_success lookback always walked back to the original
failed row (skipped is excluded from the lookback), and no code path
could dismiss that failure.
Three pieces:
1. PrintQueueItem.gate_acknowledged Boolean column (default False).
SQLite/Postgres-safe ALTER, dialect-branched DEFAULT.
2. _check_previous_success skips rows where gate_acknowledged=True so
acknowledged failures walk past the lookback. Fresh post-resume
failures still gate independently.
3. POST /api/v1/queue/printer/{printer_id}/resume — gated on
QUEUE_UPDATE_ALL — acknowledges failed/aborted items for that
printer AND restores items where
status='skipped' AND error_message='Previous print failed or was
aborted' back to pending in one transaction. Returns
{acknowledged, restored}.
Frontend banner above the active Queue tab surfaces blocked printers,
fires a warning-variant ConfirmModal, and shows a precise toast on
success.
Banner pointed to bambuddy.cool/wiki/getting-started/... which 404s;
the wiki lives under the wiki.bambuddy.cool subdomain. Anchor was
correct (MkDocs slug matches the existing "Step 4: Enable Store sent
files on external storage" heading).
Bulk operations on the Inventory page in both built-in and Spoolman modes.
Reporter wanted ten-of-the-same-spool edits without ten round-trips through
the per-spool editor.
Frontend
- New checkbox column on the inventory table (header / row / group). Sticky
toolbar appears when at least one row is selected with Edit / Print labels /
Reset usage / Archive (or Restore in the Archived tab) / Delete / Clear.
Selection clears on any filter / tab / search change so the count can't
drift from what is on screen.
- BulkEditSpoolsModal is a three-state-per-field form. The user opts in per
field by ticking its checkbox or just typing into it; only ticked + non-
empty fields are sent. Clearing fields in bulk is intentionally NOT
supported per the issue discussion.
- A new SearchableSelect renders all categorical fields (material, sub-type,
brand, category, slicer preset name, slicer filament, storage location)
with the same dropdown pattern the per-spool editor uses - text input +
chevron + filtered button list, click-outside / Escape closes. No native
select anywhere in the modal. Options merge the canonical constants from
spool-form/constants.ts with whatever already exists in the user's
inventory. Slicer-preset dropdowns fetch the same sources as the per-spool
form (Bambu Cloud + Orca Cloud + local + built-in) through buildFilament
Options() and three useQuery calls gated on isOpen.
- onSuccess handlers surface three outcomes: all-succeeded (green toast),
partial-success (yellow toast with ok / failed counts), all-failed (red
toast that keeps the selection and modal open so the user can retry).
The first cut silently dropped errors / not_found arrays - audited and
fixed before merge.
- Invalid rgba hex is flagged inline with a red border + helper text and
the Apply button is gated on a hasDroppedTickedField guard, so silently
dropping a ticked field is no longer possible.
- bulkResetConsumedCounterMutation.onSuccess now closes the confirm modal +
clears selection, matching the other three bulk mutations.
Backend
- Four new endpoints per inventory mode (eight total):
POST /api/v1/inventory/spools/bulk-update INVENTORY_UPDATE
POST /api/v1/inventory/spools/bulk-delete INVENTORY_UPDATE
POST /api/v1/inventory/spools/bulk-archive INVENTORY_UPDATE
POST /api/v1/inventory/spools/bulk-restore INVENTORY_UPDATE
POST /api/v1/spoolman/inventory/spools/bulk-* FILAMENTS_UPDATE
- Built-in update runs the same prepare_internal_spool_payload(...) +
weight_used / weight_locked auto-stamp as the per-spool PATCH.
- Spoolman update loops the per-spool update_spool route function so the
filament re-linking / extra-dict / extra-lock / shared-filament rules
stay byte-identical to single-spool edits.
- Per-spool failures inside the batch are collected. Spoolman bulk-delete /
archive / restore now catch non-HTTPException too (matches bulk-update) -
a mid-batch httpx.ConnectError or TimeoutError no longer aborts the route
with a 500 and skips the WS broadcast.
- Both modes broadcast a single inventory_changed WS event at the end of
the batch.