mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-10-17 19:36:28 +02:00
60f8529a3c83460b54b565a4dc697d3d3113bde0
1908
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
60f8529a3c |
Recover the preview slice from custom G-code the sidecar cannot parse
Opening the slice dialog on an unsliced project runs a preview slice purely
to ask the slicer which AMS slots the chosen plate consumes. Bambu Studio 2.8
writes {if timelapse_inline_photo} into the machine's time_lapse_gcode but
exports no definition for that variable, so the template is unresolvable the
moment it leaves Studio: an older sidecar stops with a placeholder parse error
before producing any slice_info. The preview returned nothing and the caller
fell back to guessing from painted faces, silently. On the H2D project this
was found with, the guess dropped the support material -- a whole slot off a
four-filament plate.
Retry the preview once with just the named template emptied, still on the
file's own settings. Keeping the embedded settings is what keeps the answer
honest: overriding the process preset instead discards the project's support
configuration, which loses that slot and moves used_g by up to 2x. Measured
against the same file: retry reproduces all four slots gram for gram, a
printer+process override returns three.
Only templates that cannot extrude are eligible -- a start or filament-change
template lays a prime line or purges, so emptying one would move the very
grams the preview reports, and returning nothing beats a confident wrong
number. Verified on a working H2D slice that emptying time_lapse_gcode leaves
every used_g/used_m in slice_info identical.
Match on a normalised option name: the slicer reports timelapse_gcode while
the 3MF stores time_lapse_gcode, so a literal comparison finds nothing.
Decide whether a retry applies before logging, so a slice that recovers does
not announce itself at WARNING twenty seconds before it succeeds.
|
||
|
|
61b2a20f38 |
Stop offering server-side slicing for STEP files
The Slice action appeared on .step / .stp and the endpoint accepted the job,
but neither slicer can load one from its command line -- both answer
"Unknown file format. Input file must have .stl, .obj, .amf(.xml) extension."
So the file was read, converted and uploaded before failing as "The input
model file to the slicer can not be parsed", which reads as a corrupt model
rather than an unsupported format.
The endpoint refuses a STEP up front with a message saying to export it as
STL or 3MF, and the Slice and pipeline buttons no longer appear on one.
Open in Slicer is unchanged and still hands STEP to the desktop application,
which opens it fine -- that was always the working path. isSliceableFilename
(desktop) and isApiSliceableFilename (sidecar) are now separate predicates so
the two cannot drift back together.
|
||
|
|
270990faf4 |
Explain an oversized model instead of reporting a slicer crash (#2802)
The sidecar caps model uploads and reports a rejection as a bare
HTTP 500 "File too large" -- multer's MulterError is not the sidecar's
AppError, so its handler falls through to the default status. A 500
reads as a crash inside the slicer, and the one message Bambuddy had
about request size was written for the 413 a reverse proxy sends, so
it never appeared. The reporter tried MAX_FILE_SIZE, BODY_PARSER_LIMIT
and EXPRESS_PAYLOAD_LIMIT, stopped nginx, and moved from Windows to
Docker -- none of which the sidecar reads.
Match the rejection by what it says rather than by its status, so an
installation still on an older sidecar image gets the same explanation.
The 500 match is strict -- the body must be only multer's message --
because a genuine CLI failure is also a 500 and has to keep reaching
the embedded-settings fallback. Old images are told to update, since
they have no setting to change; current ones are told which one to set.
Raising SlicerInputError rather than SlicerApiServerError is also what
skips the fallback retry, which had been re-uploading the identical
oversized file after a second 25-second 3MF conversion.
Log the model size on every slice. Nothing recorded it, so a support
package from a slice that died on an upload cap looked exactly like one
that died on a bad profile, and this had to be sized by hand.
Fall back to the exception class name when a transport error stringifies
empty -- three lines of the reporter's log read "Slicer sidecar
unreachable: " and stopped there.
Needs a sidecar image update to take full effect; MAX_MODEL_UPLOAD_MB is
documented in slicer-api/.env.example.
|
||
|
|
42946df211 |
Let API clients resolve user ids to names (#1894)
Archives, the queue and statistics report ownership as a numeric
created_by_id, and statistics accept it as a filter, but nothing let an
API key discover whose id was whose -- the only user listing returns
emails, roles, group membership and full permission sets, so it is
administrative and rejects keys.
Add GET /users/slim returning id + username only, gated on a new
users:read_slim permission mapped to can_read_status. That grants no
data a key could not already reach: for API-keyed requests the
permission deps return None as current_user, so the stats:filter_by_user
guard short-circuits and ?created_by_id=N is already honoured for every
N. What was missing was the ability to address the filter, not
permission to use it. The full listing stays unmapped = admin-only.
Also fix /auth/me, which answered an API key with a synthetic
administrator: id 0, role admin, is_admin true and every permission in
the enum. A key cannot reach an administrative route at all, so clients
building their UI from that response rendered actions that 403 on use.
It now reports the key owner's identity, is_admin false, and the
permissions the key's scopes actually admit. Ownerless legacy keys keep
id 0 but no longer claim admin.
---
Source user names from the slim listing where only names are needed (#1894)
Stats filter-by-user, the Archives print log filter, the File Manager
username autocomplete, the camera-token owner column and the Finance
member picker all render nothing but a username, but all of them read
the full user listing, which is gated on the admin-level users:read.
An operator granted stats:filter_by_user but not users:read got an
empty filter with no indication why.
Point them at /users/slim under a separate react-query key, since the
full listing shares the 'users' key and the two shapes would clobber
each other in the cache.
|
||
|
|
228ef36a84 |
Stop tearing down AMS drying for a print that cannot start (#2801)
A printer in FINISH with an unacknowledged plate and something pending in
its queue stopped and restarted drying once per scheduler tick, for as
long as the plate stayed unacknowledged. The reporter's Home Assistant
history recorded about 2000 state changes over ten days. No cycle ever
ran long enough to remove moisture, and cycles the user had started by
hand on other AMS units of the same printer were torn down with it.
Two concerns had become tangled. Plate-clear answers "is the bed ready
for the next job" and says nothing about whether the AMS may heat. The
gap between a finished print and the acknowledgment is when drying is
most useful -- the printer is free and nobody is waiting on it -- and
leaving the plate unacknowledged is also how people hold the queue by
hand, so the hold was costing them the drying it should have enabled.
Four faults, all in print_scheduler.
The "print takes priority" stop sat inside the not-idle branch. Drying is
not one of the things _is_printer_idle looks at, so stopping a cycle can
never turn a non-idle printer into an idle one: the stop was futile every
time it fired, and never fired on the dispatches where it was supposed to
mean something. It now runs when the printer is actually dispatchable,
and only where the model cannot dry through a print -- #2758 settled that
capable hardware should keep its cycle.
mid_print was inferred from busy_printers, which means "the queue could
not dispatch here this pass", not "is printing". A plate-held printer was
therefore treated as printing: the mid-print spool-protection cap
silently lowered its drying temperature, the cycle was logged as
(mid-print) in FINISH, and it bypassed the very gate meant to hold it.
busy_printers keeps its dispatch role; auto-drying now gets a narrow set
snapshotted before the item loop -- running, held post-dispatch, or
mid-upload -- and mid_print comes from the printer's own state. The
interlock comment at the seed already documented this hazard and worked
around it by staying out of the set; this generalises that instead of
adding a third special case. The other call site was already passing the
narrow set, so the wide one was the inconsistency.
_stop_drying sent a stop to every AMS reporting dry_time > 0. One
auto-dried unit was enough to kill a manual cycle on a different unit of
the same printer, contradicting the contract _sync_drying_state already
documents: the entry gate only knows about cycles Bambuddy began, so the
action must not reach past them. Consequence worth stating -- after a
restart Bambuddy cannot prove a running cycle is its own, so it leaves it
alone rather than risk stopping somebody's manual dry.
Fourth, and the reason #2770's guard did not catch this: a reading at or
below the threshold popped the unit's whole entry, ended_at included, so
the 30-minute re-arm cooldown went with it. An AMS reads higher warm than
cool, which is #2770's own finding, so a unit a point or two above the
threshold dipped below it as it cooled, wiped its history, and re-armed
immediately. Lifting a suspension now clears the judgement and keeps the
clock.
queue_drying_block changes behaviour as a result. It previously had no
effect on dispatch at all -- both branches skipped anyway, and it only
decided whether drying was needlessly killed. With the stop on the
dispatch path it now does what it says: a queued print waits for a
running cycle. Off by default.
Reported by @superflyer11, who traced both defects to the line and
brought ten days of external sensor history to date the cadence.
|
||
|
|
f648439536 |
Resolve the H2C rack nozzle at dispatch instead of letting firmware pick (#2800)
An H2C ran its startup clean and bed levelling on one hotend, switched,
and then printed several millimetres above the plate. The same job from
Bambu Studio was fine.
The H2C is the only model that mounts its nozzle from a rack of six, and
a print command names that nozzle by physical rack position -- the
firmware reports those as 16 to 21 -- not by the extruder index, 0 or 1,
every other dual-nozzle printer uses. Bambuddy only ever had a rack
position when a job arrived through the Virtual Printer, which captures
Bambu Studio's pick and replays it (#1780). Anything queued from the
library, an archive, the webhook or a slicer pipeline carried none, so
the field was omitted and the firmware chose -- and its choice need not
match what the file was sliced for.
The scheduler now derives the per-slot extruder assignment from the file
it is about to send, and the MQTT layer resolves it against the rack
position the printer reports live. Both are needed: the file knows which
side a slot prints from, only the printer knows which hotend is in the
carriage, and it can be swapped from the touchscreen between queueing a
job and printing it.
Derived at dispatch rather than at creation because that is the first
point knowing both the real printer and the real file -- an item can be
created unassigned, reassigned later, or have its file swapped for a
G-code-injected copy. One call therefore covers the print dialog, bulk
library adds, the webhook and pipeline runs, and no column is needed.
extract_nozzle_mapping_from_3mf is deliberately untouched. Its output
feeds the AMS matcher, where nozzle_id is compared against a tray's
extruder_id as a hard filter, and physical_extruder_map is what makes
that comparison correct -- on an H2D it is [1, 0] and flips the two.
Dropping the translation to suit the rack would send every dual-nozzle
AMS match to the wrong extruder. The dense per-slot form is a separate
function reusing the same output.
Nothing here can fail a dispatch. The command is built and published with
no exception handler above it, and the queue item is already committed as
printing by then, so a bad input has to degrade to "firmware picks"
rather than wedge the item. resolve_rack_nozzle_mapping validates every
input and raises nothing; an unresolvable mapping, an unparseable value
or an unknown rack position all omit the field, which is the behaviour
that existed before. Slot IDs are bounded before the dense list is built:
they come from the file, and one declaring filament id="50000000" would
otherwise allocate a fifty-million-entry list on the dispatch path.
Two things are not guessed. A job printing only from the fixed hotend is
still left to the firmware, because that nozzle's physical ID is not
confirmed by a known-good capture. And the rack is taken to feed extruder
0 from a single hardware observation -- if that is flipped, a one-sided
job matches nothing and falls back to the old behaviour, so only a job
using both nozzles at once could be harmed, which is what a second
capture needs to confirm.
Confined to the H2C throughout. Building the print command for 21 model
spellings with and without the new argument changes exactly three of them
-- H2C, O1C and O1C2. The other 18, including H2D and X2D, are identical.
Reported by @tru3l3gend, who diagnosed it on real hardware against a
working Bambu Studio dispatch, established the rack ID range and supplied
a patch.
|
||
|
|
493dadb1a8 |
Replace the embedded G-code viewer with the slicer's own renderer
Sliced files previewed through a vendored copy of PrettyGCode in an
iframe. It drew each move as a screen-space line -- a line has no
thickness in the scene, so it cannot occlude the layer behind it, which
is why prints came out stringy and shimmered where layers crossed. Being
a separate app in a frame, it could be neither themed nor translated, and
carried its own machinery for detecting a proxy refusing the embed.
Now built on libvgcode, the renderer OrcaSlicer draws its own preview
with, vendored from three-slicer (AGPL, same as us). It takes the THREE
namespace as an argument and imports nothing, so it runs on our 0.181
rather than the 0.160 its package pins.
The parser is ours; upstream renders its own kernel's output and ships no
G-code parser at all. Two things it has to get right, both found by
checking a real plate rather than assuming:
- BambuStudio does not use the OrcaSlicer/PrusaSlicer annotations. It
writes "; FEATURE:", "; LINE_WIDTH:", "; CHANGE_LAYER" and
"; Z_HEIGHT:", not ";TYPE:", ";WIDTH:" and ";LAYER_CHANGE". Reading
only the latter showed a 52-layer print as 23,165 layers in one colour,
because with no layer marker recognised every travel Z-hop split a
layer and every segment took the fallback feature.
- It emits a tenth of its moves as G2/G3 arcs -- 706 extruding ones in a
single plate. Ignoring them punched holes through curved walls and tree
supports. Arcs with no X/Y are the helical travel lift and lay down
nothing, so they interpolate as travels.
Four colour modes: filament (default, from the AMS slots the file was
sliced with), feature, layer height, line width. Speed, fan and
temperature are deliberately absent -- upstream derives those from
settings rather than the toolpath, and guesses dressed as measurements
are worse than an honest omission. The parser now carries the data to do
them properly later.
Legend entries are switches. Hiding removes the records before the mesh
is built rather than recolouring them: the shader packs colour into a
single float with no alpha, so there is no transparent to set, and
removal is the useful behaviour anyway -- a hidden support stops
occluding what it covered.
The scene is built once and only the toolpath rebuilds. Doing otherwise
constructed a new WebGLRenderer on every render, because the buildVolume
default is an object literal and so a fresh identity each time; browsers
cap live WebGL contexts and drop the oldest, which blanked the canvas
after a few interactions.
utils/framing.ts goes with the iframe, along with six now-orphaned
strings in all 13 locales. src/lib/vendor is excluded from eslint --
acting on findings in vendored code makes it impossible to re-copy on the
next upstream release.
|
||
|
|
84cd400685 |
Say why a preset's values are unavailable, not just that they are
The settings panel collapsed four causes into one message -- "the picked
preset's own values could not be read" -- with no indication of what to do
about it.
The overwhelmingly common cause has an obvious fix, and it isn't an edge
case: an install pulls its sidecar as SIDECAR_TAG:-latest regardless of
which Bambuddy channel it is on, so a current Bambuddy talking to a
sidecar that predates POST /profiles/resolve is the normal state, not a
misconfiguration. Those users would have seen an amber warning on every
slice with nothing pointing at the sidecar image.
resolve_profile now returns ResolvedProfile(values, reason) instead of
None for everything, the route passes the reason through, and the panel
picks its message from it:
sidecar_outdated -> name the fix: update the sidecar image
sidecar_unavailable -> the sidecar did not answer
not_configured -> no sidecar is configured
preset_unresolved -> the previous generic wording
A request that fails outright maps to sidecar_unavailable, since a
backend we cannot reach and a sidecar that will not answer are the same
thing from the dialog.
Every variant still ends with "anything you don't change still uses the
preset" -- that reassurance is the point of the notice, and it is true
whichever way the lookup failed.
Tests pin the distinction rather than just the happy path: a 404 and a
500 must produce different reasons, and each panel case asserts both that
its own message appears and that the "update the sidecar image" line does
not leak into the others.
|
||
|
|
eda86e5198 |
Show the picked preset's real values in the process-settings panel
The panel baselined every field on the option schema's compiled-in
defaults, so a preset setting a 0.42mm line width displayed 0 -- the C++
default meaning "derive from the nozzle". Every field was affected; the
Line width group just made it obvious.
Bambuddy cannot answer this itself. A standard-tier pick is only an
{inherits: ...} stub on our side, and local/cloud presets are deltas whose
remainder lives in the profile tree bundled inside the running sidecar.
The values now come from the sidecar's POST /profiles/resolve, which runs
the same resolver /slice does against the same profiles, so what the panel
shows cannot disagree with what a slice produces. Deliberately not the
local orca_profiles resolver: it walks OrcaSlicer's published tree, which
can differ from the image actually installed.
An untouched field shows the preset's value and reverting returns to it.
isModified compares against that baseline too, so fields the preset moved
off the C++ default are no longer flagged as user edits, and values nobody
typed are no longer sent. When the values can't be read -- sidecar offline
or older than the endpoint -- the panel falls back to schema defaults and
says so rather than presenting them as the preset's.
Row layout, from screenshots:
- The control column is anchored to the right edge at a fixed width. It
had been packed left after a fixed label column, leaving the values
stranded mid-container with dead space beside them.
- Units are no longer truncated to "mm o...". The cap fitted the common
"mm" but not "mm or %" or "mm/s² or %".
- The "from file" tick moved ahead of the control it qualifies; it used to
sit past the unit at the row's right edge, reading as unrelated.
Both the unit and the control keep fixed widths, and the tick's slot is
reserved on rows without one -- sizing any of them to content makes each
row's input land at a different x and the column comes out ragged.
Also fixes a field that could not be cleared: emptying a free-text input
dropped the key, so it snapped back to the baseline and retyping appended
to it ("0.42" + "0.5" = "0.420.5"). The number branch was fixed earlier;
the text branch -- coFloatOrPercent, coString, the vector types -- was
not, and the regression test used a number input so it never caught it.
Requires a sidecar built from orca-slicer-api 4b664b7 or later. Older
images 404 the endpoint, which is handled as the fallback above.
|
||
|
|
a7324ad846 |
Edit the full print-parameter set from the slice dialog
Slicing from Bambuddy meant taking a process preset as-is; any change
meant a round trip through Bambu Studio. The slice dialog now carries
OrcaSlicer's full process tree -- pages, groups, labels, tooltips,
ranges and defaults extracted from the slicer's own sources.
Enable/disable rules are evaluated from the slicer's own enable_if
expressions via a recursive-descent interpreter (no eval, CSP), with
enum comparisons validated against each option's declared values.
Anything undecidable leaves the field editable rather than greyed.
Overrides apply after the source's support config (#1881) and the
designer's carried tweaks (#2622), so an explicit choice always wins;
an untouched panel sends the same request as before.
Adds slice_engine as a separate setting from preferred_slicer -- where
slicing runs is a different axis from which binary the sidecar drives.
Only the sidecar engine is registered, so no picker renders yet.
|
||
|
|
124627d0e5 | Removed unused test backend/tests/unit/test_finance_table_migration.py | ||
|
|
7d137e312b |
Stop auto-drying re-arming into a threshold it can never reach (#2770)
An H2D armed five 12-hour drying cycles inside four hours, one of them six
seconds after the previous one ended, and none ran more than a couple of
hours.
Two things combine. The firmware ends a cycle when it decides the filament
is dry rather than when the clock runs out, and reports no fault doing it --
across this printer's history the run length tracks how wet the spools were,
from nearly the full 12 hours starting at 32% down to minutes once the unit
sat at 10-13%. That part is the AMS doing its job.
The loop is ours. An AMS reports higher relative humidity while it is warm
than once it has cooled: the same unit read 10-13% cold and 15-20% through
every cycle. With the threshold at 14% the reading at the moment a cycle
ended was always still above it, so the next 30-second pass armed another
12-hour cycle. Nothing counted, nothing waited, and it only stopped when the
box finally cooled enough to read 13%.
Auto-drying now waits 30 minutes after a cycle ends before arming another on
the same unit, and gives up on a unit after two consecutive cycles that
bring the reading no lower -- logging why and sending a new notification,
on by default because it reports that Bambuddy has stopped acting. Progress
is judged against the lowest reading any cycle on that unit has ended at,
not against the threshold, so a genuinely wet spool in a humid room coming
down 40-37-35 keeps drying however far it still is from the target;
comparing against the best so far rather than the previous end stops a
sensor wobbling by one point reading as progress every other cycle. The
suspension lifts by itself once the reading falls below the threshold.
Neither guard can stop a running cycle, and a cycle Bambuddy cut short for a
print, or that the user stopped by hand, is not counted against the unit --
so a farm that dries between queue jobs is unaffected. The threshold field
now warns below 20%, and every cycle end logs the unit's temperature and
humidity, which is what made this diagnosable.
The same bundle showed unrelated tasks failing with "database is locked",
each inside a 30.000-second Discord connect timeout. Alarms are raised from
inside the loop that records sensor history, at a point where the new rows
are added but not committed; the first read in the notification path flushed
them to satisfy itself, opening a write transaction, and the provider was
then contacted over the network with that transaction still open. SQLite
allows one writer and 30 seconds outlives the 15-second busy timeout, so
every other write in that window failed. The two reads that run before a
provider is contacted no longer flush the caller's pending work, and the
connect timeout is 5 seconds rather than 30 -- the body keeps the full 30,
so image uploads on a slow uplink are unaffected. SQLite only; Postgres has
no single-writer limit.
|
||
|
|
5c1c0914f4 |
Explain Bambu Cloud's CAPTCHA challenge instead of repeating it (#2790)
A reporter tried to connect to Bambu Cloud and got "We need you to confirm you
are not a robot" as an error toast, with no CAPTCHA anywhere to answer and
nothing to click. That sentence is Bambu's, not ours. Their anti-abuse layer had
flagged the network and was answering the sign-in with HTTP 418 and a challenge
body: {"captchaId": "...", "error": "We need you to confirm you are not a
robot"}.
Bambuddy had no idea what that was. The reply is well-formed JSON, so
_detect_cloudflare_challenge -- which triggers on an unparseable body, CF
markers, 403+cf-mitigated or 503+cf-ray -- never fired on it, and login_request
fell through to its generic error path, which lifts data["message"] or
data["error"] out and hands it to the UI verbatim. The user was left to conclude
their password was wrong or that Bambuddy was broken. Four sign-in attempts
inside eighteen seconds appear in their log, each one more evidence for the
thing that had flagged them.
is_captcha_challenge matches on the 418 status plus a challenge marker in the
body -- captchaId is the reliable one, the wording is matched too because Bambu
has shipped it under more than one phrasing. A bare 418 with no marker is
has shipped it under more than one phrasing. A bare 418 with no marker is
deliberately NOT reported as a CAPTCHA: telling someone to solve a challenge
that was never offered is the exact confusion this issue is about.
login_request, verify_code and verify_totp now return reason="captcha" with an
explanation covering the three things the reporter had no way to find out: the
credentials are not the problem, the block is keyed to the public IP address
rather than the account, and it clears by itself within a few hours.
Sign-in requests are then held back for 300s so Bambuddy stops deepening the
block. Keyed per origin, not per service: TOTP verification posts to
bambulab.com while everything else posts to api.bambulab.com, and a challenge
seen on one must not strand somebody halfway through a two-factor sign-in on the
other. Entries expire on read, so the map cannot grow past one per region. The
token endpoint is deliberately left ungated -- it is the way out.
The UI shows a persistent panel rather than a toast. A toast names a problem the
user cannot act on and then vanishes; this one stays put and carries a one-click
route to "Use access token instead", which is the only thing that works while
the challenge lasts, since that path does not touch the challenged endpoint.
MakerWorld meets the same challenge from the same edge and now shares the
detection. It used to require the literal word "robot" in the error text and
reported any other wording as an unexplained block.
The System Health scanner gets a bambu-cloud-captcha signature. The reporter's
bundle came back with zero findings while their log was full of the failure.
Its advice for a failed FTPS handshake was corrected at the same time: it still
blamed firewalls and outdated firmware, which the #2780 investigation ruled out
last release -- it is the printer's own file service wedging, and the fix is to
restart the printer. The wiki said so already; the health panel did not.
|
||
|
|
430c45666a |
Power on a printer for jobs queued to a printer class (#2786)
Queue a print against a printer class -- "Any X1C", or a Slicer Pipeline whose
target type is Printer class -- with every printer of that class switched off,
and nothing happened. The job sat pending and no smart plug was touched, while
the same file pinned to a specific printer powered that printer on within one
queue check. The reporter's log holds both halves: thirteen minutes of the item
being polled as (133, None, ...) and passed over, then a PATCH onto printer 2,
then "Printer 2 offline, attempting to power on via smart plug(s)" on the very
next tick. Same item, same plug, same Auto On setting.
Powering a printer on had only ever been written inside `if item.printer_id:`.
The model-based branch below it walks the same queue but its matcher classes an
offline printer as a reason to keep waiting -- printers_offline collects the
*name*, for the waiting reason -- and nothing on that path ever looks at plugs.
_wake_printer_for_model adds it. The model query moves into _printers_for_model
so the matcher and the wake step answer "which printers can this job run on"
from one place: a job can only be woken onto a printer the matcher would also
have considered. Candidates that failed the cross-model gate are excluded --
switching a printer on for a file that can never legally run on it leaves the
job just as stuck, with the printer now drawing power.
Two things it does that the fixed-printer branch does not:
A printer awaiting plate-clear acknowledgment is skipped. Waking it buys
nothing; it boots into IDLE and is held by the gate. That is what the reporter's
log shows for the eighty minutes after their manual edit -- "printer 2 not
available -- connected=True, state=IDLE, awaiting_plate_clear=True" every thirty
seconds to the end of the capture. The flag is Bambuddy-side and persisted, so
it is readable while the printer is still off.
At most one printer per pass, because each wake blocks the queue loop for the
boot wait. Several queued jobs bring several printers up over the following
minutes rather than a whole shelf at once.
A failed power-on opens a 600s per-printer cool-off. Without it the walk is by
id, the pass spends its single attempt on the same broken printer every time,
and a healthy sibling two slots down is never reached -- one unreachable plug
starves its whole model, and costs a 180s boot timeout out of every 30s pass.
Entries expire on read: a printer inside its cool-off is skipped before the
power-on is reached, so a live entry can never be overwritten by a success.
The failed printer is deliberately NOT added to busy_printers. It is off, not
busy; labelling it busy would misdescribe it in every later item's waiting
reason and, because an all-busy reason is treated as needing no user action,
suppress the notification too.
Assignment is left to the next pass. AMS trays arrive with the first status push
after connect, so matching filament against a printer that booted five seconds
ago can reject the printer we just woke.
Finally, the waiting reason separates "Offline: X1C-1" from "Offline, no Auto On
smart plug: X1C-2". Those are different problems and only the second is one the
user has to go and fix -- it was also the first question the reporter had to be
asked, and the queue could not answer it.
Tests cover the wake, the plate-clear skip in both gate states, all-candidates-
awaiting-plate-clear waking nothing, one wake per pass, the starvation case over
two passes, cool-off expiry, no-Auto-On-plug being left alone and named, an
incompatible sliced model waking nothing, connected printers being left alone,
scheduled-for-later and manual-start jobs switching nothing on, and a regression
pin on the fixed-printer branch.
|
||
|
|
a9b15e727f |
Stop retrying a printer whose FTPS handshake fails, and name the cause (#2780)
Two printers went on printing while every archive they produced held nothing
but a filename. Bambuddy opened port 990, the printer accepted the connection
and answered with something that was not TLS, and connect() logged a warning
and returned False -- indistinguishable, to every caller, from "the file is
not at this path". So the 3MF lookup walked all six filename variants across
five directories with four retries each, the cover endpoint ran its own
sixteen-path sweep, and the timelapse scan added four more, all against a
sixteen-path sweep, and the timelapse scan added four more, all against a
printer that could not have answered any of them. One reporter's log carried
1813 identical handshake failures, another's 3511.
The evidence says this is the printer's own file service getting stuck, not a
model, firmware or TLS-configuration problem. In #2780's bundle the same two
printers ran clean from 22 July to 4 August and failed again from the 5th; a
second bundle shows an X2D serving files for five days, flipping on 19 July,
then failing every connection for eight days with zero successes. The same
models and firmware appear in roughly twenty other bundles with no occurrences
at all. Both bundles show it happening with cap_tls_v1_2 in effect -- the X2D
and H2C entries in ftp_profiles were added on analogy with P2S to fix exactly
this symptom, and the reporter's own debug line proves they do not.
An ssl.SSLError from connect() now opens a five-minute cool-off for that
printer. Subsequent connects return False without touching the network, so a
wedged printer is contacted twice an hour instead of hundreds of times a
minute, and the single warning that is logged names the remedy. The cool-off
is dropped on expiry rather than kept, so the map holds one key per currently
wedged printer. ftps_handshake_blocked() lets the sweeps stop: the 3MF lookup
abandons the remaining paths and skips the directory-walk fallback, the cover
endpoint returns 503 naming the file service instead of a 404 that reads as
"this print has no thumbnail", and the timelapse scan separates 503 (cannot
reach the printer) from 404 (no timelapse directory) -- one 500 used to cover
both, which is what the reporter hit when reproducing.
The Connection Diagnostic completed a bare TCP connect to 990, which is why it
reported the port green throughout: the port is open, it is what is behind it
that is broken. It now completes a real implicit-TLS handshake using the
model's own ftp_profiles cap, so a pass means the FTP client would also get
through. An open port that cannot negotiate reports warn with reason no_tls,
selecting a new message in all 13 locales that points at a printer restart
rather than at the firewall. No login is attempted, so this stays valid in the
pre-save Add Printer flow.
The cool-off tests run against a real socket that accepts on 990 and replies
with a plaintext FTP banner, reproducing WRONG_VERSION_NUMBER rather than
mocking ssl. The autouse fixture clearing _mode_cache now clears the cool-off
map too -- every test here talks to 127.0.0.1, so one left behind would make
the next test's connect() a no-op.
|
||
|
|
b0927b426c | implemented pr (minor) feedback | ||
|
|
40ba1f4b0e |
implemented pr (worth fixing) feedback
update commit |
||
|
|
7dcfd0921d |
Check filament deficit for Library-backed queue items (#2779)
A job needing 20.5 g was dispatched onto a spool holding 9 g and the printer
started. _resolve_source_3mf returned LibraryFile.file_path verbatim, but that
column stores a path relative to base_dir -- so it resolved against the process
working directory, found nothing, and compute_deficit_for_queue_item treated a
missing source as "nothing to verify" and returned no deficit.
Every library-backed queue item was affected: Slicer Pipeline jobs, which are
always library-backed, and everything added through the Library's bulk Add to
queue. Both callers share the resolver, so the Play button on the queue was as
blind as the auto-dispatcher. Archive-backed items (print history, VP intake)
resolved correctly and were never affected, and neither was PrintModal, which
resolves the file on its own path.
The library branch now uses the same idiom as the eleven other readers of
file_path -- absolute stays, relative joins base_dir. The join carries a
SEC-PATH-OK marker: the value is DB-stored and generated by the Library ingest,
and it is already what resolves the file for upload, so the check has to
resolve it identically or it is not checking what gets printed.
A source that is configured but absent now logs a warning naming the item and
the resolved path. It still dispatches, because the upload needs the same file
seconds later and fails there, where blocking would strand a queue on a moved
file -- but a safety check that skips itself must not do so in silence, which
is what hid this for every library-backed item.
Tests cover the relative path (the reporter's 20.5 g against 9 g), the absolute
path against a base_dir the file is not under, and the missing-source warning.
The existing cases all used archives with absolute paths, which is the gap the
bug lived in.
|
||
|
|
34243ce7e4 |
Accept Forgejo tokens scoped to a single repository (#2775)
ForgejoBackend.test_connection asked GET /user who the token belonged to
before asking whether the token could reach the repository, and treated a 403
there as fatal. A Forgejo v15 repository-scoped token may only carry
read/write on issues and repositories, so it 403s on /user -- and was rejected
despite reaching its own repository fine, which is all a backup needs: the push
path uses the Contents API and restore reads commits, trees and blobs, all
under /repos/{owner}/{repo}. That /user call was the only one in the whole
provider layer.
The probe stays, because a 401 from it is genuinely conclusive and names a bad
token before the repo call has to guess -- Forgejo v15+ hides a private repo
behind 404 rather than 403, so the repo call cannot always tell those apart.
Every other status now falls through to the repo check.
Two additions keep the messages as sharp as before: the repo call's own 401 is
mapped to "Invalid access token" instead of a generic API error, and the 404
names write:repository and the scoped-to-another-repository case, mentioning a
possibly-invalid token only when /user did not confirm the identity.
The token hint under the field was one shared string reading "fine-grained
token with Contents read/write" -- GitHub's advice, shown to Gitea, Forgejo and
GitLab users too. It is now per provider via PROVIDER_TOKEN_HINT_I18N_KEY,
following the existing repo-URL placeholder map, translated in all 13 locales.
Tests pin the repository-scoped token connecting, a transient /user status not
blocking the repo call, both 404 wordings, and the repo-call 401; a frontend
test switches providers and asserts the hint follows.
|
||
|
|
ffcfa70e5b |
Record who queued a file from the Library and the webhook API
PrintQueueItem.created_by_id is what the queue:read_own / queue:update_own /
queue:delete_own permissions filter on, but only three of the paths that create
queue items were setting it.
The Library's bulk "Add to queue" required Permission.QUEUE_CREATE and then
bound the dependency to `_`, discarding the user, so every item it created was
ownerless -- and invisible to the person who added it if their permissions are
scoped to their own work. That is the one path built for adding many files at
once, which is where it was hardest to notice.
The webhook queue endpoint has no request user, but APIKey.user_id records the
key's owner, which is the acting identity everywhere else the key is used, so
its items are credited to that owner. Keys minted before per-user ownership
have no user_id and their items stay ownerless.
The virtual-printer path is left as-is on purpose. VirtualPrinter carries no
owner, and the obvious substitute is wrong rather than incomplete: one admin
typically configures the VP while everyone sends prints through it, so
crediting those to the admin would make the "added by" column lie and put other
people's jobs in the admin's own queue. Existing NULL rows are not backfilled
-- there is no record of who created them, and the ownerless case is already
handled throughout.
Tests pin both fixed paths and the two cases that must stay ownerless (auth
disabled, legacy key).
|
||
|
|
c38e6566f3 |
fix(backup): report the categories a failed restore already committed (#2656)
The service reports what landed on a part-way failure -- categories commit as
they finish, so results names the ones on disk -- and the modal gated the
whole result panel on success, so it showed the failure message and dropped
them.
The cache invalidation was inside that same branch, which is the half that
mattered: a run that committed the settings category and then failed left the
app rendering pre-restore settings, with no reload and no re-read, which is
the failure the modal's own reload-on-close exists to prevent.
Gate on what was written instead. A refusal that never reached a category
still carries an empty results and still keeps the form, so the mutex and
backup-in-flight cases are unchanged. A partial does not read as a success:
the tick becomes a warning and a line says the listed categories are the ones
on disk.
---
fix(backup): keep the local owner when the backup names one we cannot resolve (#2656)
An owner the backup names but this instance has no user for was written as
NULL, and overwrite is a blanket setattr -- so restoring over a local archive
that had a perfectly good owner took it away, which is the 404-for-its-own-
owner failure this column is carried across to fix. Resolving by username
widened the trigger from a stale id to any user renamed since the backup.
It is the same state as an absent key: the backup has not told us who owns
this. So it takes the same action -- the column is not written at all.
Overwrite keeps the local owner, insert lands ownerless with the note, and an
explicit null still writes, so overwrite still means "match the backup".
The notes move to the insert path with it. On overwrite nothing was taken
away, so there is nothing to warn about, which is the rule the absent-key
case already follows.
|
||
|
|
cde7bc9e12 | . | ||
|
|
0dfb53c5c5 |
Resolve a spool's material to a known drying preset before starting a cycle (#2774)
The drying popover prefilled its material from the loaded spool without
checking the preset table had that material. An AMS-HT holding Support for
PLA/PETG (tray_type PLA-S) fell back to PLA's temperature but kept PLA-S as
the material, and the dropdown displays its first option when handed a value
outside its list -- so it read PLA while PLA-S was sent. Same gap for every
composite: PETG-CF prefilled at PLA's 45C.
Resolve the tray_type to a key the table has before setting either value.
Support materials and composites resolve to their base, nylon is aliased
under its several spellings, and anything unrecognised falls back to PLA --
the coolest row, so an unknown material under-dries rather than deforming a
PLA spool.
Also record request-topic messages in the MQTT debug log. That topic carries
every command a printer is given, including Bambu Studio's, and returned
before the logging block -- so a capture could show only what the printer
said, never what it was told.
|
||
|
|
a12a4a8707 |
fix(backup): refuse the whole LDAP family on restore, not just its password (#2656)
A settings restore could substitute the instance'"'"'s authentication source.
auth.py reads the LDAP config live from the settings table on every
login, and none of ldap_server_url, ldap_user_filter, ldap_auto_provision
or ldap_default_group is credential-shaped, so the secret-key hints never
saw them and only the four auth-policy keys were protected.
ldap_enabled was covered by the companion-credential rule instead, and
that rule asks the wrong question. It judges availability - "will the
integration still work?" - and an anonymous bind works, so a payload that
simply OMITS ldap_bind_password skips the refusal and has its toggle
written. Omitting the credential is exactly what an attacker authoring
the file would do: they own the directory being pointed at, so they need
no bind credential from us.
Left unrefused, a backup repository anyone can write to yields admin:
point ldap_server_url at your own directory, set ldap_auto_provision and
ldap_default_group=Administrators, and the next login on a fresh username
is provisioned into the admin group. Overwrite-off is enough on an
instance that never configured LDAP - there are no rows to skip.
Refused by prefix so a key added to the LDAP schema later is refused by
default, and matched case-insensitively because the key comes from the
backup JSON rather than from our own writer. ldap_enabled leaves
_COMPANION_CREDENTIALS rather than sitting there as dead code, since
_is_protected_setting_key runs first.
The two tests asserting an anonymous bind was a false positive are
inverted - they encoded the hole - and the refusal reuses the existing
settingsAuthSkipped note, which already points at Settings >
Authentication.
|
||
|
|
a0d1c3674b |
fix(backup): keep both restore tallies equal to the number the preview showed (#2656)
Two ways the K-profile and spool categories broke the
restored + skipped + failed == item_count invariant the settings count
holds:
* The spools preview counted only the spools and put the usage records
in the detail, but _restore_spool_usage increments the same tally, so
any backup with usage history reported a total larger than the number
the user was shown. The preview now counts both and the detail breaks
the total down instead of adding to it.
* A K-profile entry that is not a dict was dropped silently on the
connected path. _kprofile_profile_count includes it, so the offline,
printer-missing and step-failed paths all account for it; only the one
path that talks to a printer let it leave the tally. It now counts
failed.
|
||
|
|
43d268655f |
fix(backup): commit each database category so SQLite's writer is not held (#2656)
The database phase had the same shape the K-profile phase did: _find_
archive, _find_spool, the usage dedupe and _restore_settings are all one
SELECT per row or per key, interleaved with autoflushed INSERTs, inside a
single open write transaction. A few thousand archives plus a full usage
history plausibly passes the 15 s busy_timeout, and every concurrent
writer in the app fails with "database is locked" until it finishes.
Each category now commits before the next starts. The id maps are plain
dicts in memory and the session is expire_on_commit=False, so the
ordering tolerates it.
The cost is that a later failure no longer rolls back an earlier
category, so a tally is recorded only after its category commits and
run_restore reports the categories already on disk instead of an empty
result - the same correction the K-profile split needed.
|
||
|
|
732b1d7034 |
fix(backup): gate every restore category on the permission owning its rows (#2656)
settings was gated on settings:update because a restore rewrites rows
PUT /api/v1/settings/ owns. The same argument applies to the other three
categories, and gating one but not the rest is the only state that is
not defensible: a role holding Backup alone could still write spools,
archives and K-profiles through a restore that it cannot write through
the endpoints that own them.
Each category now also requires that endpoint's write permission -
inventory:update, archives:update_all and kprofiles:update. archives
takes update_all rather than create because a restore writes rows owned
by other users, which is exactly what update_all means.
All missing permissions are reported in one refusal: a restore is a
multi-select, so naming them one at a time turns picking four categories
into four round trips.
|
||
|
|
2ef43943d3 |
docs(backup): say what the secret-key hints actually refuse (#2656)
The comment called the hint list belt-and-braces over keys the collector
already refuses to write. It is not: _collect_settings filters exactly
bambu_cloud_token and auth_secret_key, so a current backup really does
carry mqtt_password, ldap_bind_password, ha_token and prometheus_token,
and the hints are the only thing that refuses them. The companion-
credential rule sits downstream of that, so reading the list as redundant
and shortening it would write a stale credential and make that rule inert
at the same time.
Comment and test docstring only - no behaviour change.
|
||
|
|
ca6b9f8fe0 |
fix(backup): resolve a restored archive's owner by username, not by id (#2656)
created_by_id is only meaningful on the instance that wrote it. Restoring
onto a rebuilt instance - this feature's main use case - renumbers the
users table, so a live id can land on a different person and hand one
user's print history to another under archives:read_own. The id path
cannot even detect that: archivesOwnerCleared fires only for an id that
is absent, so a valid-but-wrong id produced no note at all.
The collector now records created_by_username alongside the id, and the
restore prefers it. username is unique on users, so a match is the same
person; the one case it cannot resolve - a user renamed since the backup
- falls through to ownerless with a note rather than guessing from the
id. The id stays as the fallback for backups taken before this change.
|
||
|
|
09a7413efc | implemented pr feedback #2 | ||
|
|
12c6749abe | Merge remote-tracking branch 'upstream/dev' into feature/billing | ||
|
|
b1610f70ae | Security hardening (maziggy/bambuddy-security #9) | ||
|
|
5bee8df5cd |
Broadcast AMS slot changes that keep the same material
Configuring a slot from the printer card left the card showing the old
filament until a reload or the 30s fallback poll. The command reached the
printer and the printer applied it; the update just never got broadcast.
on_printer_status_change deduplicates WebSocket pushes against a status_key
whose AMS part carried id, tray_type and state. Configure Slot writes none of
those -- it writes tray_info_idx, tray_color, tray_sub_brands and cali_idx. So
PLA to another brand or colour of PLA produced an identical key and was
dropped, while PLA to PETG came through. Reset always worked because it clears
tray_type.
Those four fields only move when someone configures a slot or swaps a spool,
so this costs no broadcasts mid-print. remain stays out of the key for the
opposite reason.
|
||
|
|
f35c184b52 |
Show Home Assistant sensors on the printer card (#1148, #448)
Binds binary_sensor and reading-carrying sensor entities to a printer and
renders their state on its card, worded by Home Assistant's device_class.
Optional per-sensor alert condition drives a notification on the transition
into the alert state and an opt-in interlock that holds queued prints while
alerting -- a hold with a readable waiting_reason, never a failure, and only
ever on a sensor that was read successfully.
Sensors get their own table rather than a wider entity pattern on SmartPlug:
get_smart_plug_by_printer would otherwise hand the card's power button a door
contact to switch.
The hold is passed to the model matcher directly rather than merged into
busy_printers: _check_auto_drying reads that set as "is currently printing"
and would put an idle-but-held printer down the mid-print drying path.
The notification_providers migration spells its default FALSE, not 0 --
Postgres rejects an integer default for a boolean and _safe_execute swallows
the error.
|
||
|
|
372ab3b788 |
Route external spools to a nozzle when the printer has no AMS (#2771)
Five X2Ds with no AMS, each printing from its external spool holder,
took a job sent to a named printer and refused the same job sent to
"Any X2D": the file uploaded, the firmware answered 0700_8012 "Failed
to get AMS mapping table", and the item failed after three attempts.
A named-printer job carries a mapping the frontend resolved at queue
time, so the scheduler's matcher never runs. A model-based job has no
printer until dispatch, so the matcher does run -- and could not see an
external spool on a dual-nozzle printer. _build_loaded_filaments derived
dual-nozzle status from ams_extruder_map, which is built from AMS info
bits, so a printer with zero AMS units reported an empty map; every
external spool got extruder_id=None, and the nozzle-aware hard filter in
_match_filaments_to_slots discarded it because None equals neither 0 nor
1. The mapping came back all -1, was cleared to None, and the print
command went out as use_ams:true with no ams_mapping and no
ams_mapping2 at all.
This is the backend half of #1257, which fixed the same logic in
useFilamentMapping.ts and left this copy behind. Mirror its inference:
a populated nozzles[1].nozzle_diameter, a non-empty ams_extruder_map, or
more than one vt_tray entry. Replaying the reporter's own push-status
now yields extruder 1 for Ext-L and 0 for Ext-R, and a nozzle-1
requirement resolves to [254] -- what their working named-printer
dispatch sent. Single-nozzle printers keep extruder_id=None; nozzles
always has two entries, so its length alone must not be the signal.
Also stop dispatching a job the firmware is certain to reject. When the
matcher ran, matched nothing, and the printer has no AMS, fail the item
with the filament and nozzle it wants instead of spending an upload and
two retries on it -- that path already ended in a failed item, just an
opaque one. With an AMS attached the firmware error still stands, since
there the user can load a spool and press Resume. Fail-safe like the
nozzle-diameter guard (#1899): every branch short of a positive finding
returns None and dispatches as before.
_apply_filament_overrides is extracted from _compute_ams_mapping_for_printer
so the message names the filament the matcher looked for rather than the one
the 3MF was sliced with.
|
||
|
|
ae802e74ca |
Say why a drying cycle ended when the firmware cuts it short (#2770)
An H2D started a twelve-hour PETG dry at 65 degC and the AMS gave up on it
twenty minutes in, with 700 of the 720 minutes still on the clock. It cooled,
humidity climbed back over the threshold, auto-drying started another
twelve-hour cycle, and that one went the same way; the reporter's AMS
temperature history shows the loop running all morning.
The log had one line for it: "AMS 0 drying complete", which is exactly what it
says for a dry that ran its full twelve hours. Nothing in a support bundle told
the two apart, and the one number that does -- the time still remaining -- was
written into that line as the previous value, where it reads like a duration
rather than a shortfall. The reporter took 700 for seconds and concluded the
cycle had lasted twelve minutes.
Bambuddy did not stop that cycle; every stop it sends is logged with the full
outgoing command and there was none. So ending it was the printer's decision,
and the account of why lives in three things already received and parsed and
never written down: the drying phase and sub-phase from the AMS info hex, the
per-unit dry_sf_reason constraint codes, and the live HMS errors.
A cycle that ends with most of its countdown left now logs all three alongside
how much of the requested duration ran. One that reaches its duration keeps the
single line it has always had. A stop Bambuddy sent is named as ours -- it is
short of its duration too, and on the telemetry alone is indistinguishable from
the firmware abandoning the cycle, so without tracking it the print-takes-priority
stop and the Stop button would both have been blamed on the printer.
Diagnostics only. Nothing about when drying starts or stops has changed, and the
restart loop is not addressed: what the firmware objects to has to be established
before Bambuddy can sensibly decide how long to wait before trying again.
|
||
|
|
da1f655c3d |
Cover nested data structures in the HA notify pass-through (#1441)
The three tests around it use flat scalars, which is also all the field's
placeholder and the wiki showed, so nothing recorded that the value is
forwarded verbatim rather than treated as a key/value list. A reporter asked
whether action buttons work; they always have, and now that is pinned.
The changelog entry said "nested options work" and left it there. It now names
actions and the two things that decide whether the buttons do anything - the
mobile_app_notification_action automation, and iOS needing a registered
category - since neither is set from Bambuddy and both are what a reader would
otherwise have to discover the way the reporter did.
|
||
|
|
d8d637cbfe |
Survive a directory that defines no posixGroup class (#2769)
Every LDAP user on an lldap directory was rejected with "Incorrect
username or password", on an install where Test Connection passed and
where the same bind DN, filter and group membership all checked out
under ldapsearch. The directory never saw the request.
_extract_user_info searches for POSIX groups alongside the memberOf
ones, and both of those filters name the posixGroup object class. ldap3
fetches the schema at connect time (get_info=ALL) and validates class
names in a filter against it while building the request, raising
LDAPObjectClassError before anything is sent. lldap marks every account
it creates as posixAccount -- which is what makes us look for POSIX
groups at all -- but defines no group class beyond groupOfNames. The
exception escaped authenticate_ldap_user, and the login route reports
any LDAP failure as bad credentials.
A directory with no posixGroup class has no posixGroup entries, which is
exactly the answer those searches would have returned. Catch it, log it
once, and carry on with the memberOf groups collected above. Both
searches sit inside the one try: they name the same class, so once one
is rejected the other cannot succeed, and attempting it would only
produce a second identical exception to swallow.
Not a regression from
|
||
|
|
868cfa2d1e |
Read the printer's own slot mapping when Spoolman has none (#2768)
A sliced file numbers its filaments 1..4; which AMS tray each came from is
a separate decision made when the job is sent. store_print_data learns it
from one of two sources, both of which require the print command to pass
through us: the mapping Bambuddy chose itself, or the one it intercepted
on the printer's local request topic. A job dispatched from Bambu Studio
while the printer is cloud-bound satisfies neither -- the command travels
through Bambu's broker and never reaches the topic we subscribe to.
slot_to_tray is then NULL and _resolve_global_tray_id guesses by position:
filament 1 from the first loaded tray, filament 2 from the second. The
reporter's X1C was loaded in the order 2, 4, 1, AMS-HT, so all four slots
were charged to the wrong spool. Their log carries the printer's own
answer, mapping=[1, 3, 0, 32768], sitting unread.
usage_tracker has consulted that field since it started resolving mappings
at completion, along with a colour match against the loaded trays for the
models that never publish it (A1, A1 Mini, P1S, P2S). Only the Spoolman
writer, which resolves at print start, never learned to -- and main.py
gates usage_tracker behind Spoolman being off, so enabling Spoolman is
what costs you the better resolver.
_resolve_slot_to_tray_fallback gives it both, at completion rather than at
print start: a printer keeps publishing the last job's mapping while it
sits idle, so reading it early would risk stamping the previous print's
mapping onto this one. A mapping we or the slicer actually recorded is
never second-guessed.
Applied in _report_partial_usage too. Cancelled and failed prints feed the
same slot_to_tray to the same resolver and mis-charged just as readily.
The resolved mapping and its source are now logged at print start and at
completion. "source: none" at start is the signal that completion will
have to fall back, and it was the one line that would have turned this
report into a five-minute triage.
Not addressed: editing the mapping after the fact, which the reporter also
asked for. ArchiveUpdate exposes neither filament field and there is no way
to re-run an attribution, so that is a feature rather than a fix.
|
||
|
|
4335ee3814 |
Stop the drying badge inventing a temperature on a uniform AMS (#2759)
The follow-up to the same report: a second AMS 2 Pro, no aux power,
loaded entirely with PLA and drying at the 45C the reporter picked,
showed 45C and then switched to 55C.
Bambu never echoes back a cycle's filament or temperature, so both come
from the target cached when the command went out, and the fallback for
a missing cache reads the loaded trays. The first pass narrowed that
fallback to units whose spools agree on a filament, which fixed the
mixed-unit case in the original report but left the uniform case
answering with the spools' RFID-recommended drying_temp -- 55C here.
Agreement across slots is evidence of what is being dried, because the
dryer heats all of them. It is no evidence of the temperature, which is
picked freely in the popover, so the recommendation was never more than
a guess wearing the same confident "PLA @ 55C" as a known target.
uniform_tray_drying_hint therefore becomes uniform_tray_filament_hint
and returns the filament alone. The badge names a temperature only when
we sent it, and otherwise shows the filament and the countdown.
Both status builders also stopped filling the two fields independently.
Entering the fallback when either was missing let a cached filament pair
with a guessed temperature and render as though both were known; the
temperature now simply has no fallback to reach.
The badge required both fields before rendering anything, so dropping
the temperature would have blanked it rather than shortening it -- the
frontend now renders each on its own terms. No new translation key: the
filament type is a passthrough.
This changes what is shown when the cached target is missing, not why
it goes missing. If the reporter was on the fixed build, the falling-
edge gate is still letting a zero through on an unpowered unit, which
needs a log covering the start of the cycle.
|
||
|
|
0827ebc5b7 |
fix(backup): let the nozzle_id default apply, and prefer the live one (#2656)
`set_kprofiles_batch` defaults the field with
`p.get("nozzle_id", f"HS00-{diameter}")`, and a `dict.get` default only
fires when the key is *absent*. The restore always set the key —
`"nozzle_id": p.get("nozzle_id")` — so a backup that carries no nozzle_id
published `nozzle_id: null` to the printer instead. Printers that omit the
field (KProfilesView's own #1748 comments) are exactly why the default is
there, and it was unreachable from this path.
Set only when known, on the same precedence the `setting_id` line beside it
already uses: the live profile first, then the backup, then absent. Live
first is the point rather than a bonus — `nozzle_id` encodes the fitted
nozzle's type as well as its diameter (`HS00-` hardened vs `SS00-`
stainless), so a nozzle swapped since the backup makes the stored value
stale, and the write lands on the nozzle fitted now.
Read with `getattr`, matching the defensive read of `extruder_id` in
`_match_kprofile`: not every live profile carries every field, and
`test_a_live_index_that_reports_no_extruder_still_matches` is the standing
control for that.
Four tests, two of which fail without the fix. The `_live` double also
gained `nozzle_id` — it is a non-default field on the real `KProfile`
dataclass, so omitting it let the double license code the real object
would have accepted.
|
||
|
|
03b2ce5c16 |
fix(backup): say when a restored archive lands without an owner (#2656)
`created_by_id` is not attribution, it is the column the access check runs
on: `_ensure_archive_visible` fails closed on NULL, so an ownerless archive
is a 404 for every caller without `archives:read_all` and never appears in
the ownership-scoped list queries.
On the overwrite path an absent key correctly leaves the local owner alone
— that rule is deliberate and unchanged. On the insert path there is no
local row to fall back on, so the archive lands ownerless, and nothing said
so. The restore reported N archives restored while the user who asked for
them saw none. Two ways in, both silent: a commit taken before the
collector recorded the column (every pre-#2656 backup), and an archive that
genuinely had no owner on the source instance.
Adds `archivesOwnerUnknown`, emitted on insert only, and suppressed when
the stale-id branch has already spoken for that row so one cause does not
produce two notes. Wording mirrors `archivesOwnerCleared` because the
consequence and the remedy are the same; the cause is not, so it is a
separate code rather than a reuse.
Five tests, plus the existing `test_a_backup_without_the_key_still_restores`
renamed and tightened — it asserted the silence this fixes. 13 locales back
in parity at 5772 leaves. No modal change: notes render through
`translateCoded`, which resolves by code.
|
||
|
|
a83645c859 |
fix(backup): dedupe spools and usage history on a comparison that can match (#2656)
Both `created_at` columns the restore dedupes on are
`server_default=func.now()`. SQLite fills those from `CURRENT_TIMESTAMP`,
which has second precision and stores `'2026-08-02 11:28:41'`, while
SQLAlchemy binds a Python datetime as `'2026-08-02 11:28:41.000000'`.
SQLite compares the two as strings, so `Model.created_at == created_at`
never matched a row the application itself created — not even when handed
that row's own value straight back out of the ORM.
Every dedupe keyed on it therefore missed, on the ordinary case rather
than an edge one:
* `_find_spool`'s composite fallback duplicated every tag-less spool on
each restore, and `overwrite_existing=True` never reached the original;
* the usage-history dedupe re-inserted the user's entire consumption
history on each restore.
Rows the restore itself had inserted did match, because those carry an
explicit bind in the same microsecond format — which is why the existing
repeat-restore tests passed throughout.
Fixed by filtering the candidates in SQL and comparing `created_at` in
Python, which sidesteps the bind format and behaves identically on
PostgreSQL, where the column keeps microseconds and the SQL comparison
happened to work. `_parse_dt` now also normalises an offset-bearing value
to naive UTC, matching what the naive columns actually hold; the collector
never writes one, so that guards hand-edited and foreign backups.
Seven tests, six of which fail without the fix. They seed the "existing"
row the way the application does — no explicit `created_at` — which is
what the existing coverage was missing.
|
||
|
|
accafafa64 |
fix(backup): report the rows a failed K-profile step already committed (#2656)
`_apply` commits the database categories before the K-profile phase, and the
comment there is right about why: `get_kprofiles` is 3 x 5 s per printer per
nozzle and SQLite's `busy_timeout` is 15 s, so holding the writer across the
MQTT phase would fail every concurrent writer in the app.
But `run_restore`'s handler returns `{"success": False, ..., "results": {}}`
for anything raised after that point, and the per-call guards inside
`_restore_kprofiles` do not cover the whole phase. Two consequences, and the
second is worse:
* The user is told the restore failed and handed an empty `results` while the
archive, spool and settings rows are durable on disk. The honest-reporting
theme this whole feature is built on inverted on exactly the path where it
matters most.
* `_reconfigure_mqtt_relay` sits inside the same `try`, downstream of the
raise. A restore that rewrote the mqtt_* rows left the relay pointed at the
pre-restore broker until something else reconfigured it.
`_apply` now contains the K-profile phase: fold the error into that category's
tally as `failed` plus a `kprofilesStepFailed` note, and let the results it has
already committed be returned and reported. Every profile the payload carried
and the phase did not account for is counted failed — silence would have been
the same lie in a smaller font. `_reconfigure_mqtt_relay` is reached again
because `_apply` returns normally. The rollback in the handler discards only
the phase's own read transaction, so a database error cannot leave the session
in a state that turns the caller's commit into the very report this prevents.
`kprofilesSendFailed` was the obvious note to reuse and is the wrong one: it
names a nozzle, a printer and a serial that a phase-level failure does not
have, and "failed to send" is untrue of a step that never got as far as
sending. One new leaf x 13 locales instead.
Belt-and-braces on the trigger that found this:
`sum(len(c.get("profiles") or []) ...)` raises TypeError on a hand-edited or
truncated backup whose `profiles` is not a list, and it runs before the guards.
Counting defensively makes that a skipped category rather than an exception
thrown over committed rows.
Control kept explicit: a failure *before* the commit still rolls back, still
reports nothing restored, and still does not touch the relay.
Tests: +5 (280 -> 285 across the three restore files, 328 -> 337 across
`-k github`). Fail-pre-fix 4 — 3 for the containment, 1 for the defensive
count, checked separately. i18n parity 13 locales at 5771 leaves.
Bundle rebuilt for the new leaf: index-CHCEEMgx.js -> index-DhOfNgMz.js. CSS
hash unchanged.
|
||
|
|
1f07f39481 |
fix(backup): stop Gitea's tree pager failing open on a missing total_count (#2656)
`if not isinstance(total, int) or seen >= total or not entries: return blobs, ""`
— the first arm short-circuited the page loop into a **success** holding page 1
only. Gitea clamps `per_page` to `MAX_RESPONSE_ITEMS` (default 50), so that is
50 entries of an arbitrarily large tree returned as a complete listing.
The restore then reports genuinely-present categories as "Not present in this
backup commit". That silent skip is the exact failure this override exists to
prevent, and the same class as E7 and G2 — G2 fixed the arithmetic here and
left the shape. GitHub and GitLab both hard-fail in the equivalent spot; only
Gitea guessed, and it guessed in the one direction that loses data quietly.
Whether Gitea always sends `total_count` on this route is beside the point: the
code was defending against a response shape it did not trust, and then trusting
it.
Now a missing or non-int `total_count` means "page until a short or empty
page". A page shorter than the first one is the last one, floored at Gitea's
default clamp so a genuinely small tree still costs exactly one request — the
reason G2 rejected paging-until-short in the `total_count`-present case, which
is unchanged and still stops on the count. The existing `page <= 50` ceiling
gives the correct hard failure for a tree that really is over cap, so this
cannot truncate.
Residual, and deliberately not widened into a `return None` on the first
ambiguous response — that would break single-page trees, the common case: an
instance whose `MAX_RESPONSE_ITEMS` is set *below* 50 *and* which omits
`total_count` would still stop at page 1. Both halves have to be true.
Tests: +6 (paged to the end with no count, on both Gitea and Forgejo; a short
page ends it; a non-int count is treated as no count; the page ceiling still
fails). Fail-pre-fix 5, control that passes either way 1 (a small tree is one
request). These don't match `-k github`, so 274 -> 280 across the three restore
files but `-k github` is unmoved.
|
||
|
|
214df517ac |
fix(backup): match a K-profile on its own extruder, not just its filament (#2656)
`_match_kprofile` scoped candidates by `filament_id` alone, and
`_current_kprofile_index` reads the live index per nozzle *diameter* — so on a
dual-nozzle printer both extruders' profiles come back in one list.
On an H2D with the same filament calibrated on both extruders, the `setting_id`
arm then matched whichever profile the printer happened to list first. A
backed-up extruder-0 entry took extruder 1's slot and went into the batch as
`{extruder_id: 0, cali_idx: <extruder-1 slot>}`, writing one extruder's
calibration over the other's and counting it restored. With an entry per
extruder — the ordinary case, since the same preset on both nozzles is what a
dual-nozzle printer is for — the two swapped slots and clobbered each other.
The `name` arm and the single-candidate fallback were equally unscoped, so this
was never only about the ambiguous case.
The data was already in hand and already being read: the backup entry carries
`extruder_id` (`:1546` copies it straight into the outgoing dict) and
`KProfile` has carried `extruder_id: int` on the live side all along. Scope
`candidates` by it the same way `filament_id` already scopes them, and the
single-candidate fallback narrows with them — ambiguity is judged within one
extruder now.
Conditional on both sides saying which extruder they mean. A pre-#2656 backup
has no `extruder_id`, and a live index that reports none must not turn every
entry into an add — that would be a far worse regression than the bug. Two
controls cover each direction of that.
`claimed` (G3) is untouched: it is per nozzle-loop and this only narrows the
candidate set feeding it.
Tests: +4 across the three restore files (270 -> 274). Fail-pre-fix 2 (each
extruder keeps its own slot; the other extruder's profile is not a stand-in),
controls that pass either way 2.
|
||
|
|
4599b6f4b4 |
fix(backup): read the printer's verdict before counting a K-profile restored (#2656)
`18938a10` on `dev` changed `set_kprofiles_batch` from returning a `bool` to
returning the sequence_id it published the command under, and moved the
verdict to a separate `await client.await_cali_ack(seq)` returning
`(ok, detail)`. Every caller in `api/routes/kprofiles.py` was updated with it.
`_restore_kprofiles` was not — it still did `sent = client.set_kprofiles_batch(...)`
and branched on `if sent:`.
A sequence_id string is truthy, so that compiled, passed, and silently made
the restore the one path left in the codebase that reports a refused
K-profile write as saved — exactly the defect `18938a10` closed everywhere
else.
Keep the sequence_id, await the ack per batch, and route an explicit refusal
into `tally.failed` with a new `kprofilesRefused` note carrying the printer's
own `reason`. Reusing `kprofilesSendFailed` would have been wrong: the
command was sent, and the printer answered.
Silence still counts restored. That is `await_cali_ack`'s own contract and
the maintainer's rule — no answer is not evidence of refusal, and firmware
predating the ack never answers. An exception reading the ack degrades the
same way rather than inventing a failure out of a write that most likely
landed.
`kprofilesAckUnreliable` is reworded to match: a refusal is now believed, so
the caveat narrows to what is genuinely left uncertain. The ack is only worth
reading at all because `18938a10` also changed the payload's `tray_id` from
`-1` to `0` — single-nozzle firmware answered `result: "fail"` to `-1` on
writes that demonstrably applied. This restore builds no `tray_id` of its
own, so it inherits that fix for free.
Tests: 4 regression (the ack is awaited for the returned sequence_id; a
refused batch counts failed and surfaces the printer's reason; one refused
nozzle does not condemn the other; the reworded caveat) + 3 controls (a
silent printer still counts restored; an unreadable ack does not fail the
batch; `None` keeps the existing send-failed path and awaits nothing). All
four confirmed failing against the pre-fix service.
|
||
|
|
29311cab2b |
fix(backup): refuse prometheus_enabled when the backup has no token either (#2656)
The companion-credential rule has five conditions, and the second one -- "the
backup itself carried a usable credential" -- was applied to all five pairs. It
should not be. It is what stops the rule over-refusing an anonymous MQTT broker
or an anonymous LDAP bind, both of which are working configs: there, an empty
credential in the backup means the restore is not producing anything weaker
than what was backed up.
For prometheus_enabled it does not transfer. An empty prometheus_token removes
/api/v1/metrics' only gate, so the exposure is a property of the toggle, not of
a downgrade relative to the backup -- and prometheus_token is optional, so a
backup taken on an instance that enabled Prometheus without ever setting one
carries the toggle and no usable token. That payload skipped the refusal
entirely: not a candidate, so the local-state pass never ran, and the blocklist
quietly dropped the token key. On a token-less target the result was
prometheus_enabled=true, no token row anywhere, and a full unauthenticated
metrics dump -- the same hole the rule was written to close, reached from the
likelier of the two directions.
So condition 2 is now per-pair: an exposure class (prometheus) that skips it and
is judged on local state alone, and an availability class (mqtt, ldap, ha,
virtual_printer) that keeps it. Nothing else changes -- the local-state pass
already stands down when the instance has its own credential, when HA_TOKEN is
in the environment, and when the toggle is already on locally, so "the exposure
pre-dates this restore" still holds and refusals still get no tally increment.
One wording consequence: an exposure toggle can now be refused on a payload with
no credential-like key in it at all, where the shared caveat would have read "0
credential-like key(s) will be skipped". That case gets its own preview detail
code, settingsCompanionOnlyWillSkip, in all 13 locales.
Tests: 6 that fail pre-fix -- the token key absent and blank at the unit level,
the new preview wording, and the integration test through the real endpoint for
both payloads (200 with a full metrics body before this, 404 after). Plus 3
controls, because over-refusal is still the real risk: the exposure route must
still stand down for a local token and for an already-on toggle, and the
availability class must still let a credential-less mqtt/ldap/virtual_printer
toggle through. The anonymous-broker and anonymous-bind controls are unchanged
and still pass.
|
||
|
|
10c9e53e84 |
docs(backup): give the real reason cloud profiles are not restorable (#2656)
Both docstrings said the collector never writes `cloud_profiles/*.json`. That
was true when they were written and stopped being true at `455a9e4b` (#2717,
"collect cloud profiles from every connected account"), which is this
branch's rebase base — so the PR was shipping a stated reason its own base
had invalidated.
The real reason is the one the PR body now gives: restoring a preset means
writing to a Bambu or Orca Cloud account, which is a different operation from
every other category here. Those land in the local database, or on a printer
the instance already owns.
Checked that nothing in the restore path is confused by the new files — the
category globs don't reach `cloud_profiles/`, and it stays out of
`RestoreCategory`.
|
||
|
|
06038ecb15 |
fix(backup): require settings:update to restore the settings category (#2656)
The restore endpoint was gated on `github:restore` alone, and the settings
category rewrites arbitrary non-auth `Settings` rows. Backup and Settings are
separate permission groups, so a role holding only Backup could change
settings it cannot change through `PUT /api/v1/settings/`, the endpoint that
owns them.
The inconsistency is ours rather than an inference: this module already makes
exactly this argument — it is why the four protected auth keys are refused
outright — and `library.py` sets the precedent of elevating a route to
`settings:update` for the same reason.
Gated per-category rather than by demoting `github:restore` wholesale, so it
stays narrow and doesn't presume the answer for `spools:*`, `archives:*` and
`kprofiles`. That broader permission-model question goes to the maintainer in
the PR reply.
`current_user is None` only means auth is disabled — `github:restore` is in
`_APIKEY_DENIED_PERMISSIONS`, so an API key never reaches the route body.
No frontend change: `request()` puts the 403's `detail` on the Error, and the
modal already renders `restoreMutation.error.message` in its red block, so
the user sees the missing permission named.
Tests: 1 regression (a Backup-only role gets 403 and `run_restore` is never
awaited) + 3 controls (the same role still restores the other three
categories; a role holding both permissions still restores settings; auth
disabled is unaffected). The regression confirmed failing against the pre-fix
route. `_create_config` gained an optional token so it works under auth.
|