The follow-up to the same report: a second AMS 2 Pro, no aux power,
loaded entirely with PLA and drying at the 45C the reporter picked,
showed 45C and then switched to 55C.
Bambu never echoes back a cycle's filament or temperature, so both come
from the target cached when the command went out, and the fallback for
a missing cache reads the loaded trays. The first pass narrowed that
fallback to units whose spools agree on a filament, which fixed the
mixed-unit case in the original report but left the uniform case
answering with the spools' RFID-recommended drying_temp -- 55C here.
Agreement across slots is evidence of what is being dried, because the
dryer heats all of them. It is no evidence of the temperature, which is
picked freely in the popover, so the recommendation was never more than
a guess wearing the same confident "PLA @ 55C" as a known target.
uniform_tray_drying_hint therefore becomes uniform_tray_filament_hint
and returns the filament alone. The badge names a temperature only when
we sent it, and otherwise shows the filament and the countdown.
Both status builders also stopped filling the two fields independently.
Entering the fallback when either was missing let a cached filament pair
with a guessed temperature and render as though both were known; the
temperature now simply has no fallback to reach.
The badge required both fields before rendering anything, so dropping
the temperature would have blanked it rather than shortening it -- the
frontend now renders each on its own terms. No new translation key: the
filament type is a passthrough.
This changes what is shown when the cached target is missing, not why
it goes missing. If the reporter was on the fixed build, the falling-
edge gate is still letting a zero through on an unpowered unit, which
needs a log covering the start of the cycle.