ElVit
cc606ed195
Added TOP143, SET43, SET44, SET45, SET46
2026-04-13 09:03:42 +02:00
ElVit
7cddcaeda0
Set Panasonic Heatpump version to 0.0.8
2026-03-26 22:06:07 +01:00
ElVit
154d3477e4
Merge branch 'main' into heatpump/feature/uart-task-handling
2026-03-24 16:54:56 +01:00
ElVit
100b13f2eb
Set heatpump version to0.0.8-beta.3
2026-03-23 22:51:14 +01:00
ElVit
ab56a76673
Merge branch 'main' into heatpump/feature/uart-task-handling
2026-03-22 13:56:10 +01:00
ElVit
3904459871
Set heatpump version to 0.0.8-beta.2
2026-03-22 10:27:10 +01:00
ElVit
0898e4eb6d
Add switch "error_reset"
2026-03-22 10:25:45 +01:00
ElVit
6ef7dd8410
Bump Panasonic Heatpump version to 0.0.8
2026-03-21 22:14:49 +01:00
ElVit
1568471077
Fix clang-format findings
2026-03-21 17:29:09 +01:00
ElVit
a3123071d0
Fixed error in read_response
2026-03-21 14:36:07 +01:00
ElVit
e587424f1b
Set version to 0.0.7-beta.2 and enhance logging in dump_config
2026-03-20 17:17:08 +01:00
ElVit
e242962c05
Avoid too many warnings if checksum of response message is invalid
2026-03-19 10:22:42 +01:00
ElVit
702550cae0
Set panasonic_heatpump version to 0.0.7
2026-03-02 10:42:30 +01:00
ElVit
4badb5b485
Refactor Panasonic Heatpump component: unify response byte retrieval method names and improve UART handling comments
2026-02-24 20:05:07 +01:00
ElVit
8224dd24b8
Used code from oxyde42-patch-1
2026-02-18 10:26:00 +01:00
ElVit
3376fdfced
Add water heater component for Panasonic heat pump integration
2026-02-06 13:46:12 +01:00
ElVit
292d098df2
Update panasonic_heatpump.h
2025-12-08 10:14:49 +01:00
ElVit
f03d7f5bf8
Update Panasonic Heatpump version to 0.0.5-beta.1
2025-12-07 23:00:59 +01:00
ElVit
98836df74f
Added uart client timeout fix
2025-12-01 19:34:59 +01:00
ElVit
9bde8737f9
updated version constant
2025-11-27 23:10:34 +01:00
ElVit
edb14478f7
minor changes
2025-11-27 22:31:29 +01:00
ElVit
5b93726000
Update panasonic_heatpump.h
2025-11-25 12:08:40 +01:00
ElVit
36658ea460
Update panasonic_heatpump.h
2025-11-25 09:21:40 +01:00
ElVit
fbe604523a
Added support for extra query ( fixes #11 )
2025-07-17 20:23:33 +02:00
ElVit
3753b3d475
Added support for extra query ( fixes #11 )
2025-07-16 16:08:09 +02:00
ElVit
18b8ed0f4a
Added options "min_temperature", "max_temperature" and "temperature_step" to the climate component.
...
Added option "min_value", "max_value" and "step" to the number component.
Added option "cool_mode" to select and climate component and removed it from panasonic_heatpump component.
Removed function "set_traits", because the user can now set its own limits in yaml.
2025-06-24 14:10:53 +02:00
ElVit
472d36bf72
Added climate entities.
...
Renamed 'raw_topics' into 'traits_settings'.
2025-06-20 13:11:50 +02:00
ElVit
f1c31b651e
Added datatype uint8_t to all enums
2025-06-20 08:51:37 +02:00
ElVit
423ca2dbc8
Added "has_state()" check in "publish_new_state()" functions.
...
Save raw_topics in a map for setting traits.
2025-06-12 20:43:42 +02:00
ElVit
641df6b42a
Added empty check in function "publish_new_state()".
...
Moved code from functions "publish_...()" to function "loop()".
2025-06-11 09:52:04 +02:00
ElVit
f9f29a635d
Refactored Code: Moved most code from main component class to entity component classes. Set traits for select entities.
2025-06-10 20:08:35 +02:00
ElVit
7ac5119fbd
Check bytes before publish state.
...
Renamed set16_1 to set16_9.
Renamed some states e. g. OperationMode (top4/set9).
Added functions to set only high or low nibble of a byte in a command message.
2025-06-06 13:05:02 +02:00
ElVit
bf59e203d2
Changed setup_priority to DATA. Replaced trigger_request_ with RequestType::NONE. Updated number min/max value change mechanism.
2025-06-02 20:29:43 +02:00
ElVit
7df705290e
Implementing set_number_min_max_value
2025-06-02 10:04:02 +02:00
ElVit
a09038bc8d
Fixed issue with min/max values of number entities
2025-05-30 19:59:33 +02:00
ElVit
40930dbf06
Use switch-case in loop function. Added function to change min/max values of some number entities.
2025-05-30 00:05:33 +02:00
ElVit
e9d1180cc8
Move log_uart_hex() to helper class.
...
Use state machine to lower loop time.
2025-05-22 22:34:21 +02:00
ElVit
0fa40dab47
Added function getResponseByte for lambda use
2025-02-21 20:45:37 +01:00
ElVit
190374dde7
Made member 'response_message_' public for use in lambda. Converted variable 'chunkSize' to #define.
2025-02-20 10:43:10 +01:00
ElVit
4d8a51c12e
Used constexpr for KnownModels. All numbers for temperature curve zone 1 or 2 are set at once.
2025-02-19 17:21:13 +01:00
ElVit
2194f3edf7
Added initial response
2025-02-17 20:20:17 +01:00
ElVit
a869f41672
improved log_uart_hex
2025-02-16 11:38:15 +01:00
ElVit
b148b465f4
Added 10ms delay after log msg. Accept also init message in read_response and read_request.
2025-02-15 22:13:18 +01:00
ElVit
c3e9f30b1f
renamed some functions, splitted decode_response in multiple functions
2025-02-13 19:27:40 +01:00
ElVit
c25b2a4281
Added PollingComponent
2025-02-07 21:19:22 +01:00
ElVit
9e8ae57d33
Added UARTDevice, removed entity_category=ENTITY_CATEGORY_CONFIG, fixed some controls
2025-02-04 15:17:37 +01:00
ElVit
772860d353
fixed comile error caused by switch::Switch. Renamed getBoolState to getBinaryState
2025-02-03 14:09:36 +01:00
ElVit
bcfcfd26f5
panasonic heatpump: removed buttons, updated numbers, selects and switches
2025-02-03 13:05:59 +01:00
ElVit
9597c1c48b
panasonic_heatpump: added missing sensor, added options log_uart_msg and polling_time
2025-02-02 15:40:10 +01:00
ElVit
1e604ec119
Added button, updated commands
2025-01-31 23:24:50 +01:00