panasonic heatpump: removed buttons, updated numbers, selects and switches

This commit is contained in:
ElVit 2025-02-03 13:05:59 +01:00
parent 9597c1c48b
commit bcfcfd26f5
11 changed files with 529 additions and 482 deletions

View File

@ -1,37 +0,0 @@
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import button
from esphome.const import (
ENTITY_CATEGORY_CONFIG,
)
from .. import CONF_PANASONIC_HEATPUMP_ID, PanasonicHeatpumpComponent, panasonic_heatpump_ns
CONF_RESET = "reset"
TYPES = [
CONF_RESET,
]
PanasonicHeatpumpButton = panasonic_heatpump_ns.class_("PanasonicHeatpumpButton", button.Button)
CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_PANASONIC_HEATPUMP_ID): cv.use_id(PanasonicHeatpumpComponent),
cv.Optional(CONF_RESET): button.button_schema(
PanasonicHeatpumpButton,
),
}
)
async def to_code(config):
hub = await cg.get_variable(config[CONF_PANASONIC_HEATPUMP_ID])
for key in TYPES:
await setup_conf(config, key, hub)
async def setup_conf(parent_config, key, hub):
if child_config := parent_config.get(key):
var = await button.new_button(child_config)
await cg.register_parented(var, parent_config[CONF_PANASONIC_HEATPUMP_ID])
cg.add(getattr(hub, f"set_{key}_button")(var))

View File

@ -1,13 +0,0 @@
#include "panasonic_heatpump_button.h"
namespace esphome
{
namespace panasonic_heatpump
{
void PanasonicHeatpumpButton::press_action()
{
this->parent_->button_press_action(this);
}
} // namespace panasonic_heatpump
} // namespace esphome

View File

@ -1,19 +0,0 @@
#pragma once
#include "esphome/components/button/button.h"
#include "../panasonic_heatpump.h"
namespace esphome
{
namespace panasonic_heatpump
{
class PanasonicHeatpumpButton : public button::Button, public Parented<PanasonicHeatpumpComponent>
{
public:
PanasonicHeatpumpButton() = default;
protected:
void press_action() override;
};
} // namespace panasonic_heatpump
} // namespace esphome

View File

@ -5,6 +5,30 @@ namespace esphome
{
namespace panasonic_heatpump
{
const uint8_t PanasonicCommand::InitialMessage[REQUEST_INITIAL_SIZE] = {
0x31, 0x05, 0x10, 0x01, 0x00, 0x00, 0x00, 0xB9
};
const uint8_t PanasonicCommand::PeriodicalMessage[REQUEST_DATA_SIZE] = {
0x71, 0x6C, 0x01, 0x10, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x12
};
const uint8_t PanasonicCommand::CommandMessage[REQUEST_DATA_SIZE] = {
0xF1, 0x6C, 0x01, 0x10, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x92
};
uint8_t PanasonicCommand::calcChecksum(std::vector<uint8_t>& data, int length)
{
uint8_t checksum = 0;
@ -16,52 +40,52 @@ namespace esphome
return checksum;
}
uint8_t PanasonicCommand::setMultiply2(unsigned int input)
uint8_t PanasonicCommand::setMultiply2(size_t input)
{
return input * 2;
}
uint8_t PanasonicCommand::setMultiply4(unsigned int input)
uint8_t PanasonicCommand::setMultiply4(size_t input)
{
return input * 4;
}
uint8_t PanasonicCommand::setPlus1Multiply4(unsigned int input)
uint8_t PanasonicCommand::setPlus1Multiply4(size_t input)
{
return (input + 1) * 4;
}
uint8_t PanasonicCommand::setPlus1Multiply8(unsigned int input)
uint8_t PanasonicCommand::setPlus1Multiply8(size_t input)
{
return (input + 1) * 8;
}
uint8_t PanasonicCommand::setPlus1Multiply16(unsigned int input)
uint8_t PanasonicCommand::setPlus1Multiply16(size_t input)
{
return (input + 1) * 16;
}
uint8_t PanasonicCommand::setPlus1Multiply64(unsigned int input)
uint8_t PanasonicCommand::setPlus1Multiply64(size_t input)
{
return (input + 1) * 64;
}
uint8_t PanasonicCommand::setPlus1(unsigned int input)
uint8_t PanasonicCommand::setPlus1(size_t input)
{
return input + 1;
}
uint8_t PanasonicCommand::setPlus73(unsigned int input)
uint8_t PanasonicCommand::setPlus73(size_t input)
{
return input + 73;
}
uint8_t PanasonicCommand::setPlus128(unsigned int input)
uint8_t PanasonicCommand::setPlus128(size_t input)
{
return input + 128;
}
uint8_t PanasonicCommand::setOperationMode(unsigned int input)
uint8_t PanasonicCommand::setOperationMode(size_t input)
{
switch (input)
{
@ -76,20 +100,6 @@ namespace esphome
return 0;
}
uint8_t PanasonicCommand::setBivalentMode(unsigned int input)
{
switch (input)
{
case 0: return 101;
case 1: return 102;
case 2: return 104;
case 3: return 105;
case 4: return 108;
case 5: return 109;
}
return 0;
}
//start of optional pcb commands
uint8_t PanasonicCommand::temp2hex(float temp)
@ -123,7 +133,7 @@ namespace esphome
return (byte6 & ~(base << bit)) | (val << bit);
}
uint8_t PanasonicCommand::setDemandControl(unsigned int input)
uint8_t PanasonicCommand::setDemandControl(size_t input)
{
switch (input)
{

View File

@ -17,44 +17,23 @@ namespace esphome
PanasonicCommand() = delete;
static uint8_t calcChecksum(std::vector<uint8_t>& data, int length);
static uint8_t setMultiply2(unsigned int input);
static uint8_t setMultiply4(unsigned int input);
static uint8_t setPlus1Multiply4(unsigned int input);
static uint8_t setPlus1Multiply8(unsigned int input);
static uint8_t setPlus1Multiply16(unsigned int input);
static uint8_t setPlus1Multiply64(unsigned int input);
static uint8_t setPlus1(unsigned int input);
static uint8_t setPlus73(unsigned int input);
static uint8_t setPlus128(unsigned int input);
static uint8_t setOperationMode(unsigned int input);
static uint8_t setBivalentMode(unsigned int input);
static uint8_t setMultiply2(size_t input);
static uint8_t setMultiply4(size_t input);
static uint8_t setPlus1Multiply4(size_t input);
static uint8_t setPlus1Multiply8(size_t input);
static uint8_t setPlus1Multiply16(size_t input);
static uint8_t setPlus1Multiply64(size_t input);
static uint8_t setPlus1(size_t input);
static uint8_t setPlus73(size_t input);
static uint8_t setPlus128(size_t input);
static uint8_t setOperationMode(size_t input);
static uint8_t temp2hex(float temp);
static uint8_t setByte6(uint8_t byte6, int val, int base, int bit);
static uint8_t setDemandControl(unsigned int input);
static uint8_t setDemandControl(size_t input);
static constexpr uint8_t InitialMessage[REQUEST_INITIAL_SIZE] = {
0x31, 0x05, 0x10, 0x01, 0x00, 0x00, 0x00, 0xB9
};
static constexpr uint8_t PeriodicalMessage[REQUEST_DATA_SIZE] = {
0x71, 0x6C, 0x01, 0x10, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x12
};
static constexpr uint8_t CommandMessage[REQUEST_DATA_SIZE] = {
0xF1, 0x6C, 0x01, 0x10, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00,
0x00, 0x00, 0x00, 0x00, 0x00, 0x92
};
static const uint8_t InitialMessage[REQUEST_INITIAL_SIZE];
static const uint8_t PeriodicalMessage[REQUEST_DATA_SIZE];
static const uint8_t CommandMessage[REQUEST_DATA_SIZE];
};
} // namespace panasonic_heatpump
} // namespace esphome

View File

@ -2,78 +2,119 @@ import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import number
from esphome.const import (
UNIT_CENTIMETER,
UNIT_PERCENT,
UNIT_CELSIUS,
UNIT_KELVIN,
UNIT_MINUTE,
ENTITY_CATEGORY_CONFIG,
)
from .. import CONF_PANASONIC_HEATPUMP_ID, PanasonicHeatpumpComponent, panasonic_heatpump_ns
CONF_SET_Z1_HEAT_REQUEST_TEMPERATURE = "z1_heat_request_temperature"
CONF_SET_Z1_COOL_REQUEST_TEMPERATURE = "z1_cool_request_temperature"
CONF_SET_Z2_HEAT_REQUEST_TEMPERATURE = "z2_heat_request_temperature"
CONF_SET_Z2_COOL_REQUEST_TEMPERATURE = "z2_cool_request_temperature"
CONF_SET_DHW_TEMP = "dhw_temp"
CONF_SET_MAX_PUMP_DUTY = "max_pump_duty"
CONF_SET_ZONE1_HEAT_TARGET_HIGH = "zone1_heat_target_high"
CONF_SET_ZONE1_HEAT_TARGET_LOW = "zone1_heat_target_low"
CONF_SET_ZONE1_HEAT_OUTSIDE_LOW = "zone1_heat_outside_low"
CONF_SET_ZONE1_HEAT_OUTSIDE_HIGH = "zone1_heat_outside_high"
CONF_SET_ZONE2_HEAT_TARGET_HIGH = "zone2_heat_target_high"
CONF_SET_ZONE2_HEAT_TARGET_LOW = "zone2_heat_target_low"
CONF_SET_ZONE2_HEAT_OUTSIDE_LOW = "zone2_heat_outside_low"
CONF_SET_ZONE2_HEAT_OUTSIDE_HIGH = "zone2_heat_outside_high"
CONF_SET_ZONE1_COOL_TARGET_HIGH = "zone1_cool_target_high"
CONF_SET_ZONE1_COOL_TARGET_LOW = "zone1_cool_target_low"
CONF_SET_ZONE1_COOL_OUTSIDE_LOW = "zone1_cool_outside_low"
CONF_SET_ZONE1_COOL_OUTSIDE_HIGH = "zone1_cool_outside_high"
CONF_SET_ZONE2_COOL_TARGET_HIGH = "zone2_cool_target_high"
CONF_SET_ZONE2_COOL_TARGET_LOW = "zone2_cool_target_low"
CONF_SET_ZONE2_COOL_OUTSIDE_LOW = "zone2_cool_outside_low"
CONF_SET_ZONE2_COOL_OUTSIDE_HIGH = "zone2_cool_outside_high"
CONF_SET_FLOOR_HEAT_DELTA = "floor_heat_delta"
CONF_SET_FLOOR_COOL_DELTA = "floor_cool_delta"
CONF_SET_DHW_HEAT_DELTA = "dhw_heat_delta"
CONF_SET_HEATER_DELAY_TIME = "heater_delay_time"
CONF_SET_HEATER_START_DELTA = "heater_start_delta"
CONF_SET_HEATER_STOP_DELTA = "heater_stop_delta"
CONF_SET_BUFFER_DELTA = "buffer_delta"
CONF_SET_HEATINGOFFOUTDOORTEMP = "heatingoffoutdoortemp"
CONF_SET_BIVALENT_START_TEMPERATURE = "bivalent_start_temperature"
CONF_SET_BIVALENT_STOP_TEMPERATURE = "bivalent_stop_temperature"
CONF_SET5 = "set5"
CONF_SET6 = "set6"
CONF_SET7 = "set7"
CONF_SET8 = "set8"
CONF_SET11 = "set11"
CONF_SET15 = "set15"
CONF_SET16_1 = "set16_1"
CONF_SET16_2 = "set16_2"
CONF_SET16_3 = "set16_3"
CONF_SET16_4 = "set16_4"
CONF_SET16_5 = "set16_5"
CONF_SET16_6 = "set16_6"
CONF_SET16_7 = "set16_7"
CONF_SET16_8 = "set16_8"
CONF_SET16_9 = "set16_9"
CONF_SET16_10 = "set16_10"
CONF_SET16_11 = "set16_11"
CONF_SET16_12 = "set16_12"
CONF_SET16_13 = "set16_13"
CONF_SET16_14 = "set16_14"
CONF_SET16_15 = "set16_15"
CONF_SET16_16 = "set16_16"
CONF_SET18 = "set18"
CONF_SET19 = "set19"
CONF_SET20 = "set20"
CONF_SET21 = "set21"
CONF_SET22 = "set22"
CONF_SET23 = "set23"
CONF_SET27 = "set27"
CONF_SET29 = "set29"
CONF_SET36 = "set36"
CONF_SET37 = "set37"
CONF_SET38 = "set38"
TYPES = [
CONF_SET_Z1_HEAT_REQUEST_TEMPERATURE,
CONF_SET_Z1_COOL_REQUEST_TEMPERATURE,
CONF_SET_Z2_HEAT_REQUEST_TEMPERATURE,
CONF_SET_Z2_COOL_REQUEST_TEMPERATURE,
CONF_SET_DHW_TEMP,
CONF_SET_MAX_PUMP_DUTY,
CONF_SET_ZONE1_HEAT_TARGET_HIGH,
CONF_SET_ZONE1_HEAT_TARGET_LOW,
CONF_SET_ZONE1_HEAT_OUTSIDE_LOW,
CONF_SET_ZONE1_HEAT_OUTSIDE_HIGH,
CONF_SET_ZONE2_HEAT_TARGET_HIGH,
CONF_SET_ZONE2_HEAT_TARGET_LOW,
CONF_SET_ZONE2_HEAT_OUTSIDE_LOW,
CONF_SET_ZONE2_HEAT_OUTSIDE_HIGH,
CONF_SET_ZONE1_COOL_TARGET_HIGH,
CONF_SET_ZONE1_COOL_TARGET_LOW,
CONF_SET_ZONE1_COOL_OUTSIDE_LOW,
CONF_SET_ZONE1_COOL_OUTSIDE_HIGH,
CONF_SET_ZONE2_COOL_TARGET_HIGH,
CONF_SET_ZONE2_COOL_TARGET_LOW,
CONF_SET_ZONE2_COOL_OUTSIDE_LOW,
CONF_SET_ZONE2_COOL_OUTSIDE_HIGH,
CONF_SET_FLOOR_HEAT_DELTA,
CONF_SET_FLOOR_COOL_DELTA,
CONF_SET_DHW_HEAT_DELTA,
CONF_SET_HEATER_DELAY_TIME,
CONF_SET_HEATER_START_DELTA,
CONF_SET_HEATER_STOP_DELTA,
CONF_SET_BUFFER_DELTA,
CONF_SET_HEATINGOFFOUTDOORTEMP,
CONF_SET_BIVALENT_START_TEMPERATURE,
CONF_SET_BIVALENT_STOP_TEMPERATURE,
CONF_SET5,
CONF_SET6,
CONF_SET7,
CONF_SET8,
CONF_SET11,
CONF_SET15,
CONF_SET16_1,
CONF_SET16_2,
CONF_SET16_3,
CONF_SET16_4,
CONF_SET16_5,
CONF_SET16_6,
CONF_SET16_7,
CONF_SET16_8,
CONF_SET16_9,
CONF_SET16_10,
CONF_SET16_11,
CONF_SET16_12,
CONF_SET16_13,
CONF_SET16_14,
CONF_SET16_15,
CONF_SET16_16,
CONF_SET18,
CONF_SET19,
CONF_SET20,
CONF_SET21,
CONF_SET22,
CONF_SET23,
CONF_SET27,
CONF_SET29,
CONF_SET36,
CONF_SET37,
CONF_SET38,
]
# min_value, max_value, step
CONF_NUMBERS = [
[ -5, 5, 1, ],
[ -5, 5, 1, ],
[ -5, 5, 1, ],
[ -5, 5, 1, ],
[ 40, 75, 1, ],
[ 64, 254, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ 1, 15, 1, ],
[ 1, 15, 1, ],
[ -12, -2, 1, ],
[ 0, 1000, 1, ],
[ 1, 15, 1, ],
[ 1, 15, 1, ],
[ 0, 10, 1, ],
[ 5, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
[ -15, 35, 1, ],
]
PanasonicHeatpumpNumber = panasonic_heatpump_ns.class_("PanasonicHeatpumpNumber", number.Number)
@ -82,133 +123,169 @@ CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_PANASONIC_HEATPUMP_ID): cv.use_id(PanasonicHeatpumpComponent),
cv.Optional(CONF_SET_Z1_HEAT_REQUEST_TEMPERATURE): number.number_schema(
cv.Optional(CONF_SET5): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_Z1_COOL_REQUEST_TEMPERATURE): number.number_schema(
cv.Optional(CONF_SET6): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_Z2_HEAT_REQUEST_TEMPERATURE): number.number_schema(
cv.Optional(CONF_SET7): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_Z2_COOL_REQUEST_TEMPERATURE): number.number_schema(
cv.Optional(CONF_SET8): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_DHW_TEMP): number.number_schema(
cv.Optional(CONF_SET11): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_MAX_PUMP_DUTY): number.number_schema(
cv.Optional(CONF_SET15): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_HEAT_TARGET_HIGH): number.number_schema(
cv.Optional(CONF_SET16_1): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_HEAT_TARGET_LOW): number.number_schema(
cv.Optional(CONF_SET16_2): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_HEAT_OUTSIDE_LOW): number.number_schema(
cv.Optional(CONF_SET16_3): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_HEAT_OUTSIDE_HIGH): number.number_schema(
cv.Optional(CONF_SET16_4): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_HEAT_TARGET_HIGH): number.number_schema(
cv.Optional(CONF_SET16_5): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_HEAT_TARGET_LOW): number.number_schema(
cv.Optional(CONF_SET16_6): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_HEAT_OUTSIDE_LOW): number.number_schema(
cv.Optional(CONF_SET16_7): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_HEAT_OUTSIDE_HIGH): number.number_schema(
cv.Optional(CONF_SET16_8): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_COOL_TARGET_HIGH): number.number_schema(
cv.Optional(CONF_SET16_9): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_COOL_TARGET_LOW): number.number_schema(
cv.Optional(CONF_SET16_10): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_COOL_OUTSIDE_LOW): number.number_schema(
cv.Optional(CONF_SET16_11): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE1_COOL_OUTSIDE_HIGH): number.number_schema(
cv.Optional(CONF_SET16_12): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_COOL_TARGET_HIGH): number.number_schema(
cv.Optional(CONF_SET16_13): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_COOL_TARGET_LOW): number.number_schema(
cv.Optional(CONF_SET16_14): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_COOL_OUTSIDE_LOW): number.number_schema(
cv.Optional(CONF_SET16_15): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONE2_COOL_OUTSIDE_HIGH): number.number_schema(
cv.Optional(CONF_SET16_16): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_FLOOR_HEAT_DELTA): number.number_schema(
cv.Optional(CONF_SET18): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_KELVIN,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_FLOOR_COOL_DELTA): number.number_schema(
cv.Optional(CONF_SET19): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_KELVIN,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_DHW_HEAT_DELTA): number.number_schema(
cv.Optional(CONF_SET20): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_KELVIN,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_HEATER_DELAY_TIME): number.number_schema(
cv.Optional(CONF_SET21): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_MINUTE,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_HEATER_START_DELTA): number.number_schema(
cv.Optional(CONF_SET22): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_KELVIN,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_HEATER_STOP_DELTA): number.number_schema(
cv.Optional(CONF_SET23): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_KELVIN,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_BUFFER_DELTA): number.number_schema(
cv.Optional(CONF_SET27): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_KELVIN,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_HEATINGOFFOUTDOORTEMP): number.number_schema(
cv.Optional(CONF_SET29): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_BIVALENT_START_TEMPERATURE): number.number_schema(
cv.Optional(CONF_SET36): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_BIVALENT_STOP_TEMPERATURE): number.number_schema(
cv.Optional(CONF_SET37): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CENTIMETER,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET38): number.number_schema(
PanasonicHeatpumpNumber,
unit_of_measurement=UNIT_CELSIUS,
entity_category=ENTITY_CATEGORY_CONFIG,
),
}
)
@ -220,6 +297,7 @@ async def to_code(config):
async def setup_conf(parent_config, key, hub):
if child_config := parent_config.get(key):
var = await number.new_number(child_config, min_value=0, max_value=100, step=.1)
index = TYPES.index(key)
var = await number.new_number(child_config, min_value=CONF_NUMBERS[index][0], max_value=CONF_NUMBERS[index][1], step=CONF_NUMBERS[index][2])
await cg.register_parented(var, parent_config[CONF_PANASONIC_HEATPUMP_ID])
cg.add(getattr(hub, f"set_{key}_number")(var))

View File

@ -158,62 +158,64 @@ namespace esphome
LOG_TEXT_SENSOR("", "Panasonic Heatpump TextSensor", this->top126_text_sensor_);
LOG_TEXT_SENSOR("", "Panasonic Heatpump TextSensor", this->top130_text_sensor_);
#endif
#ifdef USE_BUTTON
LOG_BUTTON("", "Panasonic Heatpump Button", this->reset_button_);
#endif
#ifdef USE_NUMBER
LOG_NUMBER("", "Panasonic Heatpump Number", this->z1_heat_request_temperature_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->z1_cool_request_temperature_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->z2_heat_request_temperature_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->z2_cool_request_temperature_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->dhw_temp_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->max_pump_duty_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_heat_target_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_heat_target_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_heat_outside_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_heat_outside_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_heat_target_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_heat_target_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_heat_outside_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_heat_outside_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_cool_target_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_cool_target_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_cool_outside_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone1_cool_outside_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_cool_target_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_cool_target_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_cool_outside_low_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->zone2_cool_outside_high_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->floor_heat_delta_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->floor_cool_delta_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->dhw_heat_delta_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->heater_delay_time_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->heater_start_delta_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->heater_stop_delta_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->buffer_delta_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->heatingoffoutdoortemp_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->bivalent_start_temperature_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->bivalent_stop_temperature_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set5_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set6_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set7_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set8_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set11_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set15_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_1_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_2_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_3_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_4_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_5_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_6_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_7_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_8_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_9_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_10_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_11_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_12_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_13_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_14_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_15_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set16_16_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set18_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set19_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set20_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set21_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set22_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set23_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set27_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set29_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set36_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set37_number_);
LOG_NUMBER("", "Panasonic Heatpump Number", this->set38_number_);
#endif
#ifdef USE_SELECT
LOG_SELECT("", "Panasonic Heatpump Select", this->quiet_mode_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->powerful_mode_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->operation_mode_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->zones_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->external_pad_heater_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->powerful_mode2_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->bivalent_mode_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->set3_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->set4_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->set9_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->set17_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->set26_select_);
LOG_SELECT("", "Panasonic Heatpump Select", this->set35_select_);
#endif
#ifdef USE_SWITCH
LOG_SWITCH("", "Panasonic Heatpump Switch", this->heatpump_state_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->holiday_mode_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->force_dhw_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->force_defrost_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->force_sterilization_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->pump_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->main_schedule_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->alt_external_sensor_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->buffer_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set1_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set2_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set10_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set12_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set13_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set14_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set24_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set25_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set28_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set30_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set31_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set32_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set33_switch_);
LOG_SWITCH("", "Panasonic Heatpump Switch", this->set34_switch_);
#endif
}
@ -309,7 +311,7 @@ namespace esphome
void PanasonicHeatpumpComponent::log_uart_hex(std::string prefix, std::vector<uint8_t> bytes, uint8_t separator)
{
if (this->log_uart_msg_ == false) return;
std::string logStr;
logStr = "[" + std::to_string(bytes.size()) + "]";
ESP_LOGI(TAG, "%s %s", prefix.c_str(), logStr.c_str());
@ -538,77 +540,73 @@ namespace esphome
delay(100); // NOLINT
}
#ifdef USE_BUTTON
void PanasonicHeatpumpComponent::button_press_action(button::Button* object)
{
// if (object == this->reset_button_)
// this->send_request(value, index);
}
#endif
#ifdef USE_NUMBER
void PanasonicHeatpumpComponent::number_control(number::Number* object, float value)
{
// if (object == this->z1_heat_request_temperature_number_)
// this->send_request(value, index);
// else if (object == this->z1_cool_request_temperature_number_)
// else if (object == this->z2_heat_request_temperature_number_)
// else if (object == this->z2_cool_request_temperature_number_)
// else if (object == this->dhw_temp_number_)
// else if (object == this->max_pump_duty_number_)
// else if (object == this->zone1_heat_target_high_number_)
// else if (object == this->zone1_heat_target_low_number_)
// else if (object == this->zone1_heat_outside_low_number_)
// else if (object == this->zone1_heat_outside_high_number_)
// else if (object == this->zone2_heat_target_high_number_)
// else if (object == this->zone2_heat_target_low_number_)
// else if (object == this->zone2_heat_outside_low_number_)
// else if (object == this->zone2_heat_outside_high_number_)
// else if (object == this->zone1_cool_target_high_number_)
// else if (object == this->zone1_cool_target_low_number_)
// else if (object == this->zone1_cool_outside_low_number_)
// else if (object == this->zone1_cool_outside_high_number_)
// else if (object == this->zone2_cool_target_high_number_)
// else if (object == this->zone2_cool_target_low_number_)
// else if (object == this->zone2_cool_outside_low_number_)
// else if (object == this->zone2_cool_outside_high_number_)
// else if (object == this->floor_heat_delta_number_)
// else if (object == this->floor_cool_delta_number_)
// else if (object == this->dhw_heat_delta_number_)
// else if (object == this->heater_delay_time_number_)
// else if (object == this->heater_start_delta_number_)
// else if (object == this->heater_stop_delta_number_)
// else if (object == this->buffer_delta_number_)
// else if (object == this->heatingoffoutdoortemp_number_)
// else if (object == this->bivalent_start_temperature_number_)
// else if (object == this->bivalent_stop_temperature_number_)
if (object == this->set5_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 38);
else if (object == this->set6_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 39);
else if (object == this->set7_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 40);
else if (object == this->set8_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 41);
else if (object == this->set11_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 42);
else if (object == this->set15_number_) this->send_command_message(PanasonicCommand::setPlus1(value), 45);
else if (object == this->set16_1_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 75);
else if (object == this->set16_2_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 76);
else if (object == this->set16_3_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 77);
else if (object == this->set16_4_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 78);
else if (object == this->set16_5_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 79);
else if (object == this->set16_6_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 80);
else if (object == this->set16_7_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 81);
else if (object == this->set16_8_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 82);
else if (object == this->set16_9_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 86);
else if (object == this->set16_10_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 87);
else if (object == this->set16_11_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 88);
else if (object == this->set16_12_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 89);
else if (object == this->set16_13_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 90);
else if (object == this->set16_14_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 91);
else if (object == this->set16_15_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 92);
else if (object == this->set16_16_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 93);
else if (object == this->set18_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 84);
else if (object == this->set19_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 94);
else if (object == this->set20_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 99);
else if (object == this->set21_number_) this->send_command_message(PanasonicCommand::setPlus1(value), 104);
else if (object == this->set22_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 105);
else if (object == this->set23_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 106);
else if (object == this->set27_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 59);
else if (object == this->set29_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 83);
else if (object == this->set36_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 65);
else if (object == this->set37_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 66);
else if (object == this->set38_number_) this->send_command_message(PanasonicCommand::setPlus128(value), 68);
}
#endif
#ifdef USE_SELECT
void PanasonicHeatpumpComponent::select_control(select::Select* object, const std::string &value)
void PanasonicHeatpumpComponent::select_control(select::Select* object, size_t value)
{
// if (object == this->quiet_mode_select_)
// this->send_request(value, index);
// else if (object == this->powerful_mode_select_)
// else if (object == this->operation_mode_select_)
// else if (object == this->zones_select_)
// else if (object == this->external_pad_heater_select_)
// else if (object == this->powerful_mode2_select_)
// else if (object == this->bivalent_mode_select_)
if (object == this->set3_select_) this->send_command_message(PanasonicCommand::setPlus1Multiply8(value), 7);
else if (object == this->set4_select_) this->send_command_message(PanasonicCommand::setPlus73(value), 7);
else if (object == this->set9_select_) this->send_command_message(PanasonicCommand::setOperationMode(value), 6);
else if (object == this->set17_select_) this->send_command_message(PanasonicCommand::setPlus1Multiply64(value), 6);
else if (object == this->set26_select_) this->send_command_message(PanasonicCommand::setPlus1Multiply16(value), 25);
else if (object == this->set35_select_) this->send_command_message(PanasonicCommand::setPlus1Multiply4(value), 26);
}
#endif
#ifdef USE_SWITCH
void PanasonicHeatpumpComponent::switch_control(switch::Switch* object, bool state)
{
// if (object == this->heatpump_state_switch_)
// this->send_request(value, index);
// else if (object == this->holiday_mode_switch_)
// else if (object == this->force_dhw_switch_)
// else if (object == this->force_defrost_switch_)
// else if (object == this->force_sterilization_switch_)
// else if (object == this->pump_switch_)
// else if (object == this->main_schedule_switch_)
// else if (object == this->alt_external_sensor_switch_)
// else if (object == this->buffer_switch_)
if (object == this->set1_switch_) this->send_command_message(PanasonicCommand::setPlus1(value), 4);
else if (object == this->set2_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply16(value), 5);
else if (object == this->set10_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply64(value), 4);
else if (object == this->set12_switch_) this->send_command_message(PanasonicCommand::setMultiply2(value), 8);
else if (object == this->set13_switch_) this->send_command_message(PanasonicCommand::setMultiply4(value), 8);
else if (object == this->set14_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply16(value), 4);
else if (object == this->set24_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply64(value), 5);
else if (object == this->set25_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply16(value), 20);
else if (object == this->set28_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply4(value), 24);
else if (object == this->set30_switch_) this->send_command_message(PanasonicCommand::setPlus1(value), 23);
else if (object == this->set31_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply16(value), 23);
else if (object == this->set32_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply64(value), 23);
else if (object == this->set33_switch_) this->send_command_message(PanasonicCommand::setPlus1Multiply4(value), 23);
else if (object == this->set34_switch_) this->send_command_message(PanasonicCommand::setPlus1(value), 26);
}
#endif
} // namespace panasonic_heatpump

View File

@ -13,9 +13,6 @@
#ifdef USE_TEXT_SENSOR
#include "esphome/components/text_sensor/text_sensor.h"
#endif
#ifdef USE_BUTTON
#include "esphome/components/button/button.h"
#endif
#ifdef USE_NUMBER
#include "esphome/components/number/number.h"
#endif
@ -38,6 +35,7 @@ namespace esphome
class PanasonicHeatpumpComponent : public Component
{
public:
// ToDo: Add template for custom sensor classes similar to SUB_SENSOR (see Pipsolar)
#ifdef USE_SENSOR
SUB_SENSOR(top1);
SUB_SENSOR(top5);
@ -183,68 +181,68 @@ namespace esphome
SUB_TEXT_SENSOR(top126);
SUB_TEXT_SENSOR(top130);
#endif
#ifdef USE_BUTTON
SUB_BUTTON(reset);
void button_press_action(button::Button* object);
#endif
#ifdef USE_NUMBER
SUB_NUMBER(z1_heat_request_temperature);
SUB_NUMBER(z1_cool_request_temperature);
SUB_NUMBER(z2_heat_request_temperature);
SUB_NUMBER(z2_cool_request_temperature);
SUB_NUMBER(dhw_temp);
SUB_NUMBER(max_pump_duty);
SUB_NUMBER(zone1_heat_target_high);
SUB_NUMBER(zone1_heat_target_low);
SUB_NUMBER(zone1_heat_outside_low);
SUB_NUMBER(zone1_heat_outside_high);
SUB_NUMBER(zone2_heat_target_high);
SUB_NUMBER(zone2_heat_target_low);
SUB_NUMBER(zone2_heat_outside_low);
SUB_NUMBER(zone2_heat_outside_high);
SUB_NUMBER(zone1_cool_target_high);
SUB_NUMBER(zone1_cool_target_low);
SUB_NUMBER(zone1_cool_outside_low);
SUB_NUMBER(zone1_cool_outside_high);
SUB_NUMBER(zone2_cool_target_high);
SUB_NUMBER(zone2_cool_target_low);
SUB_NUMBER(zone2_cool_outside_low);
SUB_NUMBER(zone2_cool_outside_high);
SUB_NUMBER(floor_heat_delta);
SUB_NUMBER(floor_cool_delta);
SUB_NUMBER(dhw_heat_delta);
SUB_NUMBER(heater_delay_time);
SUB_NUMBER(heater_start_delta);
SUB_NUMBER(heater_stop_delta);
SUB_NUMBER(buffer_delta);
SUB_NUMBER(heatingoffoutdoortemp);
SUB_NUMBER(bivalent_start_temperature);
SUB_NUMBER(bivalent_stop_temperature);
SUB_NUMBER(set5);
SUB_NUMBER(set6);
SUB_NUMBER(set7);
SUB_NUMBER(set8);
SUB_NUMBER(set11);
SUB_NUMBER(set15);
SUB_NUMBER(set16_1);
SUB_NUMBER(set16_2);
SUB_NUMBER(set16_3);
SUB_NUMBER(set16_4);
SUB_NUMBER(set16_5);
SUB_NUMBER(set16_6);
SUB_NUMBER(set16_7);
SUB_NUMBER(set16_8);
SUB_NUMBER(set16_9);
SUB_NUMBER(set16_10);
SUB_NUMBER(set16_11);
SUB_NUMBER(set16_12);
SUB_NUMBER(set16_13);
SUB_NUMBER(set16_14);
SUB_NUMBER(set16_15);
SUB_NUMBER(set16_16);
SUB_NUMBER(set18);
SUB_NUMBER(set19);
SUB_NUMBER(set20);
SUB_NUMBER(set21);
SUB_NUMBER(set22);
SUB_NUMBER(set23);
SUB_NUMBER(set27);
SUB_NUMBER(set29);
SUB_NUMBER(set36);
SUB_NUMBER(set37);
SUB_NUMBER(set38);
void number_control(number::Number* object, float value);
#endif
#ifdef USE_SELECT
SUB_SELECT(quiet_mode);
SUB_SELECT(powerful_mode);
SUB_SELECT(operation_mode);
SUB_SELECT(zones);
SUB_SELECT(external_pad_heater);
SUB_SELECT(powerful_mode2);
SUB_SELECT(bivalent_mode);
SUB_SELECT(set3);
SUB_SELECT(set4);
SUB_SELECT(set9);
SUB_SELECT(set17);
SUB_SELECT(set26);
SUB_SELECT(set35);
void select_control(select::Select* object, const std::string &value);
void select_control(select::Select* object, size_t value);
#endif
#ifdef USE_SWITCH
SUB_SWITCH(heatpump_state);
SUB_SWITCH(holiday_mode);
SUB_SWITCH(force_dhw);
SUB_SWITCH(force_defrost);
SUB_SWITCH(force_sterilization);
SUB_SWITCH(pump);
SUB_SWITCH(main_schedule);
SUB_SWITCH(alt_external_sensor);
SUB_SWITCH(buffer);
SUB_SWITCH(set1);
SUB_SWITCH(set2);
SUB_SWITCH(set10);
SUB_SWITCH(set12);
SUB_SWITCH(set13);
SUB_SWITCH(set14);
SUB_SWITCH(set24);
SUB_SWITCH(set25);
SUB_SWITCH(set28);
SUB_SWITCH(set30);
SUB_SWITCH(set31);
SUB_SWITCH(set32);
SUB_SWITCH(set33);
SUB_SWITCH(set34);
void switch_control(switch::Switch* object, bool state);
#endif

View File

@ -2,27 +2,35 @@ import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import select
from esphome.const import (
UNIT_PERCENT,
ENTITY_CATEGORY_CONFIG,
)
from .. import CONF_PANASONIC_HEATPUMP_ID, PanasonicHeatpumpComponent, panasonic_heatpump_ns
CONF_SET_QUIET_MODE = "quiet_mode"
CONF_SET_POWERFUL_MODE = "powerful_mode"
CONF_SET_OPERATION_MODE = "operation_mode"
CONF_SET_ZONES = "zones"
CONF_SET_EXTERNAL_PAD_HEATER = "external_pad_heater"
CONF_SET_POWERFUL_MODE2 = "powerful_mode2"
CONF_SET_BIVALENT_MODE = "bivalent_mode"
CONF_SET3 = "set3"
CONF_SET4 = "set4"
CONF_SET9 = "set9"
CONF_SET17 = "set17"
CONF_SET26 = "set26"
CONF_SET35 = "set35"
TYPES = [
CONF_SET_QUIET_MODE,
CONF_SET_POWERFUL_MODE,
CONF_SET_OPERATION_MODE,
CONF_SET_ZONES,
CONF_SET_EXTERNAL_PAD_HEATER,
CONF_SET_POWERFUL_MODE2,
CONF_SET_BIVALENT_MODE,
CONF_SET3,
CONF_SET4,
CONF_SET9,
CONF_SET17,
CONF_SET26,
CONF_SET35,
]
CONF_SELECTS = [
[ "Off mode", "Quiet mode 1", "Quiet mode 2", "Quiet mode 3", ],
[ "off", "30min", "60min", "90min", ],
[ "off", "30min", "60min", "90min", ],
[ "Heat only", "Cool only", "Auto", "DHW only", "Heat+DHW", "Cool+DHW", "Auto + DHW", ],
[ "Zone 1", "Zone2", "Zone1 and Zone2", ],
[ "Disabled", "Type-A", "Type-B" ],
[ "Alternativ", "Parallel", "Advanced Parallel" ],
]
PanasonicHeatpumpSelect = panasonic_heatpump_ns.class_("PanasonicHeatpumpSelect", select.Select)
@ -31,26 +39,29 @@ CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_PANASONIC_HEATPUMP_ID): cv.use_id(PanasonicHeatpumpComponent),
cv.Optional(CONF_SET_QUIET_MODE): select.select_schema(
cv.Optional(CONF_SET3): select.select_schema(
PanasonicHeatpumpSelect,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_POWERFUL_MODE): select.select_schema(
cv.Optional(CONF_SET4): select.select_schema(
PanasonicHeatpumpSelect,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_OPERATION_MODE): select.select_schema(
cv.Optional(CONF_SET9): select.select_schema(
PanasonicHeatpumpSelect,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ZONES): select.select_schema(
cv.Optional(CONF_SET17): select.select_schema(
PanasonicHeatpumpSelect,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_EXTERNAL_PAD_HEATER): select.select_schema(
cv.Optional(CONF_SET26): select.select_schema(
PanasonicHeatpumpSelect,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_POWERFUL_MODE2): select.select_schema(
PanasonicHeatpumpSelect,
),
cv.Optional(CONF_SET_BIVALENT_MODE): select.select_schema(
cv.Optional(CONF_SET35): select.select_schema(
PanasonicHeatpumpSelect,
entity_category=ENTITY_CATEGORY_CONFIG,
),
}
)
@ -62,6 +73,7 @@ async def to_code(config):
async def setup_conf(parent_config, key, hub):
if child_config := parent_config.get(key):
var = await select.new_select(child_config, options=["dummy1", "dummy2"])
index = TYPES.index(key)
var = await select.new_select(child_config, options=CONF_SELECTS[index])
await cg.register_parented(var, parent_config[CONF_PANASONIC_HEATPUMP_ID])
cg.add(getattr(hub, f"set_{key}_select")(var))

View File

@ -8,7 +8,9 @@ namespace esphome
void PanasonicHeatpumpSelect::control(const std::string &value)
{
this->publish_state(value);
this->parent_->select_control(this, value);
auto index = this->active_index();
if (index.has_value())
this->parent_->select_control(this, index.value());
}
} // namespace panasonic_heatpump
} // namespace esphome

View File

@ -2,31 +2,41 @@ import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import switch
from esphome.const import (
UNIT_PERCENT,
ENTITY_CATEGORY_CONFIG,
)
from .. import CONF_PANASONIC_HEATPUMP_ID, PanasonicHeatpumpComponent, panasonic_heatpump_ns
CONF_SET_HEATPUMP_STATE = "heatpump_state"
CONF_SET_HOLIDAY_MODE = "holiday_mode"
CONF_SET_FORCE_DHW = "force_dhw"
CONF_SET_FORCE_DEFROST = "force_defrost"
CONF_SET_FORCE_STERILIZATION = "force_sterilization"
CONF_SET_PUMP = "pump"
CONF_SET_MAIN_SCHEDULE = "main_schedule"
CONF_SET_ALT_EXTERNAL_SENSOR = "alt_external_sensor"
CONF_SET_BUFFER = "buffer"
CONF_SET1 = "set1"
CONF_SET2 = "set2"
CONF_SET10 = "set10"
CONF_SET12 = "set12"
CONF_SET13 = "set13"
CONF_SET14 = "set14"
CONF_SET24 = "set24"
CONF_SET25 = "set25"
CONF_SET28 = "set28"
CONF_SET30 = "set30"
CONF_SET31 = "set31"
CONF_SET32 = "set32"
CONF_SET33 = "set33"
CONF_SET34 = "set34"
TYPES = [
CONF_SET_HEATPUMP_STATE,
CONF_SET_HOLIDAY_MODE,
CONF_SET_FORCE_DHW,
CONF_SET_FORCE_DEFROST,
CONF_SET_FORCE_STERILIZATION,
CONF_SET_PUMP,
CONF_SET_MAIN_SCHEDULE,
CONF_SET_ALT_EXTERNAL_SENSOR,
CONF_SET_BUFFER,
CONF_SET1,
CONF_SET2,
CONF_SET10,
CONF_SET12,
CONF_SET13,
CONF_SET14,
CONF_SET24,
CONF_SET25,
CONF_SET28,
CONF_SET30,
CONF_SET31,
CONF_SET32,
CONF_SET33,
CONF_SET34,
]
PanasonicHeatpumpSwitch = panasonic_heatpump_ns.class_("PanasonicHeatpumpSwitch", switch.Switch)
@ -35,32 +45,61 @@ CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(CONF_PANASONIC_HEATPUMP_ID): cv.use_id(PanasonicHeatpumpComponent),
cv.Optional(CONF_SET_HEATPUMP_STATE): switch.switch_schema(
cv.Optional(CONF_SET1): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_HOLIDAY_MODE): switch.switch_schema(
cv.Optional(CONF_SET2): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_FORCE_DHW): switch.switch_schema(
cv.Optional(CONF_SET10): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_FORCE_DEFROST): switch.switch_schema(
cv.Optional(CONF_SET12): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_FORCE_STERILIZATION): switch.switch_schema(
cv.Optional(CONF_SET13): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_PUMP): switch.switch_schema(
cv.Optional(CONF_SET14): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_MAIN_SCHEDULE): switch.switch_schema(
cv.Optional(CONF_SET24): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_ALT_EXTERNAL_SENSOR): switch.switch_schema(
cv.Optional(CONF_SET25): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET_BUFFER): switch.switch_schema(
cv.Optional(CONF_SET28): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET30): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET31): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET32): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET33): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
cv.Optional(CONF_SET34): switch.switch_schema(
PanasonicHeatpumpSwitch,
entity_category=ENTITY_CATEGORY_CONFIG,
),
}
)