Merge branch 'main' into heatpump/feature/uart-task-handling
This commit is contained in:
commit
ab56a76673
|
|
@ -565,6 +565,8 @@ switch:
|
|||
name: "Set External Heat Cool Control"
|
||||
set34:
|
||||
name: "Set Bivalent Control"
|
||||
error_reset:
|
||||
name: "Error Reset (Restart Heatpump)"
|
||||
```
|
||||
|
||||
### Selects
|
||||
|
|
|
|||
|
|
@ -82,7 +82,7 @@ void PanasonicHeatpumpClimate::control(const climate::ClimateCall& call) {
|
|||
}
|
||||
|
||||
this->publish_state();
|
||||
this->keep_state_ = 2;
|
||||
this->keep_state_ = KEEP_STATE;
|
||||
}
|
||||
|
||||
void PanasonicHeatpumpClimate::publish_new_state(const std::vector<uint8_t>& data) {
|
||||
|
|
|
|||
|
|
@ -35,11 +35,7 @@ void PanasonicHelpers::write_uart_log(UartLogDirection direction, const uint8_t*
|
|||
return;
|
||||
|
||||
logStr += byte_array_to_hex_string(data, length, separator);
|
||||
|
||||
for (size_t i = 0; i < logStr.length(); i += UART_LOG_CHUNK_SIZE) {
|
||||
ESP_LOGI(TAG, "%s %s", msgDir.c_str(), logStr.substr(i, UART_LOG_CHUNK_SIZE).c_str());
|
||||
delay(10);
|
||||
}
|
||||
ESP_LOGI(TAG, "%s %s", msgDir.c_str(), logStr.c_str());
|
||||
}
|
||||
|
||||
std::string PanasonicHelpers::byte_array_to_hex_string(const std::vector<uint8_t>& data, const char separator) {
|
||||
|
|
|
|||
|
|
@ -5,10 +5,6 @@
|
|||
#include <vector>
|
||||
#include <string>
|
||||
|
||||
#ifndef UART_LOG_CHUNK_SIZE
|
||||
#define UART_LOG_CHUNK_SIZE 120
|
||||
#endif
|
||||
|
||||
namespace esphome {
|
||||
namespace panasonic_heatpump {
|
||||
enum UartLogDirection : uint8_t {
|
||||
|
|
|
|||
|
|
@ -116,7 +116,7 @@ void PanasonicHeatpumpNumber::control(float value) {
|
|||
};
|
||||
|
||||
this->publish_state(state);
|
||||
this->keep_state_ = 2;
|
||||
this->keep_state_ = KEEP_STATE;
|
||||
}
|
||||
|
||||
void PanasonicHeatpumpNumber::publish_new_state(const std::vector<uint8_t>& data) {
|
||||
|
|
|
|||
|
|
@ -12,7 +12,11 @@
|
|||
#include "commands.h"
|
||||
|
||||
#ifndef PANASONIC_HEATPUMP_VERSION
|
||||
#define PANASONIC_HEATPUMP_VERSION "0.0.7-beta.3"
|
||||
#define PANASONIC_HEATPUMP_VERSION "0.0.8-beta.2"
|
||||
#endif
|
||||
|
||||
#ifndef KEEP_STATE
|
||||
#define KEEP_STATE 1
|
||||
#endif
|
||||
|
||||
namespace esphome {
|
||||
|
|
|
|||
|
|
@ -42,7 +42,7 @@ void PanasonicHeatpumpSelect::control(const std::string& value) {
|
|||
};
|
||||
|
||||
this->publish_state(value);
|
||||
this->keep_state_ = 2;
|
||||
this->keep_state_ = KEEP_STATE;
|
||||
}
|
||||
|
||||
void PanasonicHeatpumpSelect::publish_new_state(const std::vector<uint8_t>& data) {
|
||||
|
|
|
|||
|
|
@ -20,6 +20,7 @@ CONF_SET31 = "set31" # Set External Error
|
|||
CONF_SET32 = "set32" # Set External Compressor Control
|
||||
CONF_SET33 = "set33" # Set External Heat Cool Control
|
||||
CONF_SET34 = "set34" # Set Bivalent Control
|
||||
CONF_ERROR = "error_reset" # Error Reset (Restart Heatpump)
|
||||
|
||||
TYPES = [
|
||||
CONF_SET1,
|
||||
|
|
@ -35,6 +36,7 @@ TYPES = [
|
|||
CONF_SET32,
|
||||
CONF_SET33,
|
||||
CONF_SET34,
|
||||
CONF_ERROR,
|
||||
]
|
||||
|
||||
PanasonicHeatpumpSwitch = panasonic_heatpump_ns.class_(
|
||||
|
|
@ -85,6 +87,9 @@ CONFIG_SCHEMA = cv.Schema(
|
|||
cv.Optional(CONF_SET34): switch.switch_schema(
|
||||
PanasonicHeatpumpSwitch,
|
||||
),
|
||||
cv.Optional(CONF_ERROR): switch.switch_schema(
|
||||
PanasonicHeatpumpSwitch,
|
||||
),
|
||||
}
|
||||
).extend(cv.COMPONENT_SCHEMA)
|
||||
|
||||
|
|
|
|||
|
|
@ -52,12 +52,15 @@ void PanasonicHeatpumpSwitch::write_state(bool state) {
|
|||
case SwitchIds::CONF_SET34:
|
||||
this->parent_->set_command_byte(PanasonicCommand::setPlus1(value), 26);
|
||||
break;
|
||||
case SwitchIds::CONF_ERROR:
|
||||
this->parent_->set_command_byte(value, 8);
|
||||
break;
|
||||
default:
|
||||
return;
|
||||
};
|
||||
|
||||
this->publish_state(state);
|
||||
this->keep_state_ = 2;
|
||||
this->keep_state_ = KEEP_STATE;
|
||||
}
|
||||
|
||||
void PanasonicHeatpumpSwitch::publish_new_state(const std::vector<uint8_t>& data) {
|
||||
|
|
@ -130,6 +133,11 @@ void PanasonicHeatpumpSwitch::publish_new_state(const std::vector<uint8_t>& data
|
|||
if (this->state == new_state)
|
||||
return;
|
||||
break;
|
||||
case SwitchIds::CONF_ERROR:
|
||||
new_state = PanasonicDecode::getBinaryState(data[8]);
|
||||
if (this->state == new_state)
|
||||
return;
|
||||
break;
|
||||
default:
|
||||
return;
|
||||
};
|
||||
|
|
|
|||
|
|
@ -21,6 +21,7 @@ enum SwitchIds : uint8_t {
|
|||
CONF_SET32,
|
||||
CONF_SET33,
|
||||
CONF_SET34,
|
||||
CONF_ERROR,
|
||||
};
|
||||
|
||||
class PanasonicHeatpumpSwitch : public switch_::Switch,
|
||||
|
|
|
|||
|
|
@ -40,7 +40,7 @@ void PanasonicHeatpumpWaterHeater::control(const water_heater::WaterHeaterCall&
|
|||
};
|
||||
|
||||
this->publish_state();
|
||||
this->keep_state_ = 2;
|
||||
this->keep_state_ = KEEP_STATE;
|
||||
}
|
||||
|
||||
void PanasonicHeatpumpWaterHeater::publish_new_state(const std::vector<uint8_t>& data) {
|
||||
|
|
|
|||
|
|
@ -469,6 +469,8 @@ switch:
|
|||
name: "Set External Heat Cool Control"
|
||||
set34:
|
||||
name: "Set Bivalent Control"
|
||||
error_reset:
|
||||
name: "Error Reset (Restart Heatpump)"
|
||||
|
||||
# Test climate platform
|
||||
climate:
|
||||
|
|
|
|||
Loading…
Reference in New Issue