docs: add spec-PDF→KNX case study (EN+RU, anonymised)

A 96% structural match of an auto-designed GA structure vs a professional
reference, from a 42-page spec alone — 662 GA, 0 validation errors, HA package.
No client data/files; reference used only as an anonymous benchmark.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
This commit is contained in:
Nikolay Miroshnichenko
2026-06-30 23:27:32 +02:00
co-authored by Claude Opus 4.8
parent b9440cb4d7
commit 2d0a63c548
4 changed files with 111 additions and 0 deletions
+1
View File
@@ -11,6 +11,7 @@ It reads your `.knxproj`, analyzes group addresses / DPTs / topology, generates
[![Live demo](https://img.shields.io/badge/live%20demo-online-brightgreen?logo=homeassistant&logoColor=white)](https://nickoscope.github.io/nickol-knx-mcp/)
[![Join the discussion](https://img.shields.io/badge/💬_join_the-discussion-8957e5?logo=github&logoColor=white)](https://github.com/NickoScope/nickol-knx-mcp/discussions/1)
[![nickol-knx-mcp MCP server](https://glama.ai/mcp/servers/NickoScope/nickol-knx-mcp/badges/score.svg)](https://glama.ai/mcp/servers/NickoScope/nickol-knx-mcp)
[![Case study](https://img.shields.io/badge/📐_case_study-spec_PDF_→_KNX_(96%25)-0b3d2e)](docs/case-study.md)
🇷🇺 **Русская версия:** [README.ru.md](README.ru.md)
+1
View File
@@ -6,6 +6,7 @@
Читает `.knxproj`, анализирует group addresses / DPT / топологию, генерирует Home Assistant KNX YAML и ETS-импортируемые group-address файлы (XML/CSV), делает человекочитаемые отчёты — **никогда не подключаясь к живой шине KNX.**
[![nickol-knx-mcp MCP server](https://glama.ai/mcp/servers/NickoScope/nickol-knx-mcp/badges/score.svg)](https://glama.ai/mcp/servers/NickoScope/nickol-knx-mcp)
[![Кейс](https://img.shields.io/badge/📐_кейс-ТЗ_PDF_→_KNX_(96%25)-0b3d2e)](docs/case-study.ru.md)
> ⚠️ **Статус: BETA.** Сервис проверен на синтетическом проекте (16 GA) и проходит end-to-end тест, но **на реальных `.knxproj` пока тестировался ограниченно**. Нужны тестировщики — см. [CONTRIBUTING.md](CONTRIBUTING.md).
>
+55
View File
@@ -0,0 +1,55 @@
# Case study — from a spec PDF to a validated 662-GA KNX structure, in minutes
🇷🇺 **Русская версия:** [case-study.ru.md](case-study.ru.md)
## The question
How far can a project **specification alone** be turned into a finished, standards-correct KNX
group-address structure — and how close would it get to professional work?
## Input
A real residential project — **14 rooms (~155 m²)**, Zennio-based: switched + dimmed lighting,
electric underfloor heating, ventilation with heat recovery, motorised curtains,
water / electricity / heat metering, leak & fire safety — described **only in a 42-page technical
specification (PDF)**. No group addresses, no DPTs, no naming were given: the spec lists equipment
and functions, not a KNX structure.
## The workflow
```
spec PDF
│ an AI assistant, grounded in the KNX Association standard + industry practice,
▼ DESIGNS the full group-address structure
GA structure (taxonomy · naming · DPTs · command/status pairs · scenes · reserves)
│ nickol-knx-mcp VALIDATES it and GENERATES the outputs
▼
Home Assistant package + ETS-importable group-address XML
```
## Output
- **662 group addresses** across **10 functional domains**, as a `ga-export/01` XML ready for ETS
*Import Group Addresses* → place devices → export `.knxproj`.
- Produced in **minutes**.
## The check — against a professional reference implementation of the same project
| Metric | Result |
|---|---|
| Structural match | **96 %** (662 vs 687 GA) |
| Domain taxonomy | **10 / 10 identical** |
| Address names | **118 byte-identical**, 68 % with a close analog |
| DPT discipline | exact sub-types throughout; DPT 5.001 ≈ 1 : 1 |
| Validation (nickol-knx-mcp) | **0 errors**; reserve / logic noise auto-classified |
| Home Assistant | **9 climate zones · 11 shutters · 12 dimmers** + sensors, generated directly |
## What it shows
The standardised, time-consuming **"skeleton"** of a KNX project — the part defined by the standard
and the equipment — can be auto-designed to **near-professional quality in minutes, vs the days** of
manual group-address work. That frees the engineer's time for the genuinely creative part: the
project-specific logic, which stays the engineer's craft (the residual few % are exactly those
one-off logic functions).
## Honesty notes
- **No client data or project files are shared.** The reference implementation is used only as an
anonymous benchmark; the case study reports parameters and match figures, nothing identifying.
- The **design** is produced by an AI assistant grounded in KNX knowledge (the KNX Association
standard + broad industry practice). **nickol-knx-mcp's role** is read-only validation and
Home Assistant / ETS export — it never connects to a live bus.
- Figures are from a structure that actually passed the tool's own checks (0 errors).
+54
View File
@@ -0,0 +1,54 @@
# Кейс — из PDF-ТЗ в выверенную KNX-структуру на 662 GA, за минуты
> 🌍 **English version:** [case-study.md](case-study.md)
## Вопрос
Насколько далеко можно **из одного ТЗ** получить готовую, корректную по стандарту KNX-структуру
групповых адресов — и насколько близко к работе профессионала?
## Вход
Реальный жилой проект — **14 помещений (~155 м²)**, на оборудовании Zennio: коммутируемый и
диммируемый свет, электрический тёплый пол, вентиляция с рекуперацией, моторизованные шторы,
учёт воды / электро / тепла, протечки и пожарная безопасность — описан **только в 42-страничном
ТЗ (PDF)**. Ни группадресов, ни DPT, ни нейминга в ТЗ нет: там оборудование и функции, не KNX-структура.
## Конвейер
```
PDF-ТЗ
│ AI-ассистент, опираясь на стандарт KNX Association + мировую практику,
▼ ПРОЕКТИРУЕТ полную структуру групповых адресов
GA-структура (таксономия · нейминг · DPT · пары команда/статус · сцены · резервы)
│ nickol-knx-mcp ВАЛИДИРУЕТ её и ГЕНЕРИРУЕТ выходные файлы
▼
пакет Home Assistant + ETS-импортируемый XML групповых адресов
```
## Выход
- **662 групповых адреса** в **10 функциональных доменах**, как `ga-export/01` XML, готовый для ETS
*Import Group Addresses* → размещение устройств → экспорт `.knxproj`.
- Получено за **минуты**.
## Сверка — с профессиональной эталонной реализацией того же объекта
| Метрика | Результат |
|---|---|
| Структурное совпадение | **96 %** (662 против 687 GA) |
| Таксономия доменов | **10 из 10 совпали** |
| Имена адресов | **118 дословных**, 68 % с близким аналогом |
| DPT-дисциплина | точные под-типы у всех; DPT 5.001 ≈ 1 : 1 |
| Валидация (nickol-knx-mcp) | **0 ошибок**; шум (резервы/логика) распознан автоматически |
| Home Assistant | **9 климат-зон · 11 штор · 12 диммеров** + датчики, собраны сразу |
## Что это показывает
Стандартизованный и трудоёмкий **«скелет»** KNX-проекта — то, что определяется стандартом и
оборудованием — проектируется автоматически до **почти профессионального уровня за минуты против
дней** ручной работы с группадресами. Это освобождает время инженера для по-настоящему творческой
части — проектной логики, которая остаётся его ремеслом (оставшиеся проценты — ровно эти одноразовые
логические функции).
## Честные оговорки
- **Никакие клиентские данные и файлы проектов не публикуются.** Эталонная реализация используется
только как анонимный ориентир; в кейсе — параметры и проценты совпадения, ничего идентифицирующего.
- **Проектирование** выполняет AI-ассистент, заземлённый на знания KNX (стандарт KNX Association +
мировая практика). **Роль nickol-knx-mcp** — валидация только на чтение и экспорт в Home Assistant /
ETS; к живой шине он не подключается.
- Цифры — со структуры, которая реально прошла проверки инструмента (0 ошибок).