Files
bambuddy/spoolbuddy/scripts
maziggy 2b1fe03159 Fix SpoolBuddy scale first reading and extract hardware drivers
The NAU7802 ADC returns a stale max-scale value (0x7FFFFF) on its
  first conversion after power-up, polluting the moving average and
  making the initial weight report wildly inaccurate. Flush the first
  reading during init().

  Also extract both hardware drivers out of diagnostic scripts into
  proper daemon modules:
  - NAU7802 scale driver: scripts/scale_diag.py -> daemon/nau7802.py
  - PN5180 NFC driver: scripts/read_tag.py -> daemon/pn5180.py

  The production daemon was importing driver classes from test scripts
  since the original SpoolBuddy commit. Diagnostic scripts now import
  from the driver modules. Removed the sys.path hack from main.py.
2026-03-25 11:57:28 +01:00
..