bambuddy/backend/app/models/smart_plug_energy_snapshot.py
maziggy 8266d225d2 fix(energy): date-range energy in total mode + restart-resilient per-print tracking (#941)
The Statistics page reported "Gesamt" (All Time) kWh correctly but showed
  zero for Today/Week/Month in total-consumption mode. Two bugs drove it:

  1. The starting plug counter was kept in an in-memory dict
     `_print_energy_start` that was lost on any backend restart mid-print, so
     the per-print `energy_kwh` delta silently never got computed. The stats
     endpoint's fallback path `SUM(PrintArchive.energy_kwh)` therefore summed
     to zero for users running in total mode.
  2. Total-consumption mode has no per-print delta by design — it includes
     idle/preheat/standby — so the fallback to archive rows was the wrong
     strategy even when the data existed.

  Fix, in two parts:

  - Persist `energy_start_kwh` on the archive row and read it back from a
    fresh session at print end. Deletes `_print_energy_start` and its 5
    call sites, replacing them with a single `_record_energy_start()` helper.
    Per-print tracking is now restart-resilient regardless of tracking mode.
  - Add hourly `smart_plug_energy_snapshots` table + `_snapshot_loop()` in
    SmartPlugManager. Rewrote the `/archives/stats` energy branch as
    `_sum_snapshot_deltas()` which computes per-plug
    `max(0, last-in-range - baseline)` where baseline is the latest snapshot
    at or before the range start, falling back to the earliest-ever snapshot
    and signalling `energy_data_warming_up` when no pre-range baseline
    exists (fresh upgrade). MQTT plugs are skipped from snapshots since they
    only report "today" and have no lifetime counter.

  Frontend: QuickStatsWidget renders an AlertTriangle next to Energy Used /
  Energy Cost with a tooltip when `energy_data_warming_up` is true, so the
  "low values right after upgrading" situation is explained in-product.
  Fully localised across 7 UI languages.

  Tests: new backend unit tests cover the snapshot delta arithmetic
  (baseline/endpoint, counter reset clamp, multi-plug, warming-up fallback,
  endpoint windowing), per-print restart resilience via expunge_all, and the
  snapshot task lifecycle (start idempotent, stop cancels). Frontend tests
  assert the warning icon appears only when the flag is set and only on the
  energy tiles.

  Docs: updated `CHANGELOG.md`, `README.md`, wiki `features/energy.md`,
  wiki `features/statistics.md`, and website `features.html` with the new
  behaviour and warming-up explanation.
2026-04-11 11:14:54 +02:00

23 lines
929 B
Python

from datetime import datetime
from sqlalchemy import DateTime, Float, ForeignKey, Index, Integer
from sqlalchemy.orm import Mapped, mapped_column
from backend.app.core.database import Base
class SmartPlugEnergySnapshot(Base):
"""Hourly snapshot of a smart plug's lifetime energy counter.
Powers date-range queries in "total consumption" energy mode. For a given
range we sum `(last_snapshot_in_range - last_snapshot_before_range)` per plug.
"""
__tablename__ = "smart_plug_energy_snapshots"
__table_args__ = (Index("ix_plug_energy_snapshots_plug_time", "plug_id", "recorded_at"),)
id: Mapped[int] = mapped_column(Integer, primary_key=True)
plug_id: Mapped[int] = mapped_column(ForeignKey("smart_plugs.id", ondelete="CASCADE"), nullable=False)
recorded_at: Mapped[datetime] = mapped_column(DateTime, nullable=False)
lifetime_kwh: Mapped[float] = mapped_column(Float, nullable=False)