maziggy 724ce6f6ef fix(ams): stop showing the humidity drop index as a percentage (issue #3140)
Bambu sends two humidity fields that are not the same quantity.
    humidity_raw is relative humidity in percent; humidity is a 1-5 drop
    index, and it runs the other way -- OpenBambuAPI's push_info sample
    pairs "humidity:30%" with "humidity_idx:4", so a high index means dry
    where a high percentage means wet.

    Four call sites used the index whenever no percentage arrived. A unit
    sending only the index therefore rendered as "2%" in the green band
    while being the second-wettest of the five steps, charted an average of
    index values as a percentage, and sat under every humidity threshold
    forever, since no index can reach one -- the alarm and auto-drying could
    not fire for such a unit at all.

    - utils/ams_humidity: one leaf helper, a percentage or None. The index
      is never converted; None is what every caller already handles.
    - routes/printers, printer_manager, print_scheduler, main, bambu_mqtt:
      all five readings go through it, so the card, the websocket, the
      chart, the alarm and auto-drying cannot answer differently.
    - main: a unit that reports the index and no usable percentage says so
      once per unit in the log, with its firmware versions requested. No
      supported printer is known to do this, and "known" is doing work
      there -- the alternative is a card that goes blank with no trace.

    Three faults found while checking what else those paths touched:

    - main: humidity_raw=float(x) if x else None stored NULL for a numeric
      0% while writing 0.0 to humidity on the same row.
    - main: that same expression was unguarded, unlike the parse above it,
      so a non-numeric humidity_raw raised inside record_ams_history and
      aborted the pass for every printer, not just the one that sent it.
    - routes/ams_history: the averages were tested for truthiness, so a
      window averaging exactly 0 reported no average while the min and max
      beside it reported 0.0.

    An affected unit now reports no humidity rather than a number that means
    the opposite: the indicator is hidden, the chart leaves a gap, the alarm
    and auto-drying skip the unit. Temperature is untouched. Auto-drying's
    outcome is unchanged either way -- an index could never cross the
    threshold -- so only the intent moves.

    No supported printer is known to be affected; the report came from an
    install running X1Plus, which Bambuddy does not support. Verified
    against 7927 recorded samples from seven AMS units including an AMS-HT:
    not one used the fallback. Two percentages that did fall through to the
    index no longer do -- a reading with a decimal point, and "38.0", which
    int() rejected.