mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-10-05 05:31:31 +02:00
a1e5afbd2df1f5faea0101a6fa2b5beddba73f3f
2001
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
a1e5afbd2d |
Keep a dispatch's retries out of the FTPS cool-off (issue #2898)
A failed TLS handshake arms a 300s per-IP cool-off, and connect()
consulted it for every caller. A print dispatch retries after 2s, so
once the cool-off was armed all four attempts were answered from the
gate rather than the network, and every further job queued for that
printer failed the same way for the rest of the window. The reporter's
farm lost three jobs to one handshake error, with the retry budget
contributing nothing to any of them.
The gate was serving two callers that want opposite things from it. The
background sweeps -- the post-print 3MF, cover and timelapse fetches --
walk ~110 candidate paths against one wedged printer with nobody
waiting, and backing off for minutes is right for them. A dispatch is
one delete plus at most four upload attempts with someone watching a
progress bar. So the split is by caller: a client built with
respect_handshake_cooloff=False goes to the printer regardless, and the
dispatch's delete and upload -- and a firmware upload, same shape --
opt out. Everything else keeps #2780's behaviour untouched.
In the reported trace it is the pre-upload delete that takes the SSL
error and arms the cool-off, 8ms before the upload's first attempt, so
exempting the upload alone would have left one dispatch's worth of the
problem in place.
Callers that do respect the cool-off no longer sleep out a retry loop
against it: with_ftp_retry takes the printer's IP and stops at the
attempt that armed the gate, instead of spending three more attempts
and six seconds on connections that cannot happen. It also reports the
attempts it really made -- "failed after 4 attempts" for one attempt is
part of how this read as a network problem.
Two diagnosis fixes go with it. The cool-off skip was the one connect()
failure path that reported without naming its cause, and at DEBUG, so
four identical reason-free warnings were all the operator saw. It now
says at WARNING that nothing was sent and how long the printer has
left, once per cool-off rather than once per attempt -- not every
caller is gated, and a download-zip of 200 files would otherwise repeat
the sentence 200 times, which is the flood #2780 set out to stop.
And a dispatch that fails this way no longer tells anyone to check
whether the SD card is inserted and formatted -- nothing reached the
printer's filesystem, so the card is the one part of the machine that
was working. The message names the file service and rules the card out.
It is used only when a handshake failed during the dispatch itself,
read from the cool-off deadline MOVING rather than merely being armed:
the dispatch ignores the gate, so it can be running underneath one an
unrelated background fetch left behind, and blaming TLS for an upload
that really hit a full disk would repeat the mistake in the other
direction.
Tests count sockets rather than return values, since "returned False"
looks identical whether or not anything was attempted -- which is what
made the original report a log dive. Reverting any one of the five
behaviours above fails a distinct test.
|
||
|
|
38abf57bb7 |
Let a print start on a nozzle the printer can fetch (issue #2885)
The nozzle-diameter guard compared the sliced diameter against the
mounted hotends alone. On an H2C both hotends commonly read the same
size, so a job sliced for anything else was failed before upload with
"install the matching nozzle before printing" -- even with that nozzle
sitting in the tool-changer rack, which the printer fetches by itself
as part of starting a print. The reporter saw it as an asymmetry:
going to 0.4mm always worked, going to 0.2mm never did, and only
fetching the nozzle by hand on the printer's own screen let the print
run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm
hotends, a 0.6mm slice was refused identically.
Placement is what made it fatal rather than merely wrong. The guard
runs near the top of _start_print and the rack picker near the bottom,
so the item was failed before the code that would have chosen the dock
ever ran.
Bambuddy had the rack contents the whole time. nozzle_info carries an
entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks --
each with its diameter, so the guard now tests the slice against both
sets. It keys off the ids rather than the printer model: only a rack
machine reports 16-21, which leaves no registry to keep in sync. An
empty dock is absent from the payload entirely, so an id appearing
there already means a nozzle is in it. stat is left uninterpreted; it
read 0 on every entry, occupied and empty alike.
A diameter in neither a hotend nor a dock still stops the print before
it uploads, and the message now names both sets so the machine's real
stock is visible.
The same telemetry showed a second fault, pointing the other way. A
hotend with nothing mounted is still reported, keeping the diameter of
the nozzle it last held -- measured at idle, where the rack-side hotend
read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle
back in the dock. That stale value counted as installed. Presence now
comes from the serial and the temperature rating, and emptiness has to
be stated rather than merely unstated: the serial must be the
firmware's explicit "N/A" and the rating absent. A firmware that
reports neither field normalises to exactly that, and reading it as
empty would switch the guard off on that machine.
Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job
dispatches with nozzle_mapping [21], chosen by Bambuddy rather than
left to the firmware.
|
||
|
|
7c8f1f9435 |
Keep a dispatch's retries out of the FTPS cool-off (issue #2898)
A failed TLS handshake arms a 300s per-IP cool-off, and connect() consulted it for every caller. A print dispatch retries after 2s, so once the cool-off was armed all four attempts were answered from the gate rather than the network, and every further job queued for that printer failed the same way for the rest of the window. The reporter's farm lost three jobs to one handshake error, with the retry budget contributing nothing to any of them. The gate was serving two callers that want opposite things from it. The background sweeps -- the post-print 3MF, cover and timelapse fetches -- walk ~110 candidate paths against one wedged printer with nobody waiting, and backing off for minutes is right for them. A dispatch is one delete plus at most four upload attempts with someone watching a progress bar. So the split is by caller: a client built with respect_handshake_cooloff=False goes to the printer regardless, and the dispatch's delete and upload -- and a firmware upload, same shape -- opt out. Everything else keeps #2780's behaviour untouched. In the reported trace it is the pre-upload delete that takes the SSL error and arms the cool-off, 8ms before the upload's first attempt, so exempting the upload alone would have left one dispatch's worth of the problem in place. Callers that do respect the cool-off no longer sleep out a retry loop against it: with_ftp_retry takes the printer's IP and stops at the attempt that armed the gate, instead of spending three more attempts and six seconds on connections that cannot happen. It also reports the attempts it really made -- "failed after 4 attempts" for one attempt is part of how this read as a network problem. Two diagnosis fixes go with it. The cool-off skip was the one connect() failure path that reported without naming its cause, and at DEBUG, so four identical reason-free warnings were all the operator saw. It now says at WARNING that nothing was sent and how long the printer has left, once per cool-off rather than once per attempt -- not every caller is gated, and a download-zip of 200 files would otherwise repeat the sentence 200 times, which is the flood #2780 set out to stop. And a dispatch that fails this way no longer tells anyone to check whether the SD card is inserted and formatted -- nothing reached the printer's filesystem, so the card is the one part of the machine that was working. The message names the file service and rules the card out. It is used only when a handshake failed during the dispatch itself, read from the cool-off deadline MOVING rather than merely being armed: the dispatch ignores the gate, so it can be running underneath one an unrelated background fetch left behind, and blaming TLS for an upload that really hit a full disk would repeat the mistake in the other direction. Tests count sockets rather than return values, since "returned False" looks identical whether or not anything was attempted -- which is what made the original report a log dive. Reverting any one of the five behaviours above fails a distinct test. |
||
|
|
4961990a7a |
Let a print start on a nozzle the printer can fetch (issue #2885)
The nozzle-diameter guard compared the sliced diameter against the mounted hotends alone. On an H2C both hotends commonly read the same size, so a job sliced for anything else was failed before upload with "install the matching nozzle before printing" -- even with that nozzle sitting in the tool-changer rack, which the printer fetches by itself as part of starting a print. The reporter saw it as an asymmetry: going to 0.4mm always worked, going to 0.2mm never did, and only fetching the nozzle by hand on the printer's own screen let the print run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm hotends, a 0.6mm slice was refused identically. Placement is what made it fatal rather than merely wrong. The guard runs near the top of _start_print and the rack picker near the bottom, so the item was failed before the code that would have chosen the dock ever ran. Bambuddy had the rack contents the whole time. nozzle_info carries an entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks -- each with its diameter, so the guard now tests the slice against both sets. It keys off the ids rather than the printer model: only a rack machine reports 16-21, which leaves no registry to keep in sync. An empty dock is absent from the payload entirely, so an id appearing there already means a nozzle is in it. stat is left uninterpreted; it read 0 on every entry, occupied and empty alike. A diameter in neither a hotend nor a dock still stops the print before it uploads, and the message now names both sets so the machine's real stock is visible. The same telemetry showed a second fault, pointing the other way. A hotend with nothing mounted is still reported, keeping the diameter of the nozzle it last held -- measured at idle, where the rack-side hotend read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle back in the dock. That stale value counted as installed. Presence now comes from the serial and the temperature rating, and emptiness has to be stated rather than merely unstated: the serial must be the firmware's explicit "N/A" and the rating absent. A firmware that reports neither field normalises to exactly that, and reading it as empty would switch the guard off on that machine. Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job dispatches with nozzle_mapping [21], chosen by Bambuddy rather than left to the firmware. |
||
|
|
5925e387f0 |
Name an AMS slot's colour by its material, not its hex alone (issue #2875)
A hex is not one colour in Bambu's range. #FFFFFF is Jade White in PLA
Basic, Ivory White in PLA Matte and plain White in six other materials;
popover resolved its title from the hex alone, against a map that keeps
one name per hex, so an ivory Matte spool read "Jade White" while the
profile line beside it correctly read Matte Ivory.
/inventory/colors/map now carries the names collapsing loses, keyed
"<material>|<hex>". An entry is emitted only when it recovers a name the
same manufacturer's own range lost -- 11 of them against the 608 colours
in the shipped catalog. Both halves matter: a name equal to the flat
answer is weight, and a name from another brand is not a recovery, it
would put Prusament's "Pristine White" on every generic white PLA slot.
A slot with a spool assigned from Inventory is titled with that spool's
own colour name: it is the roll the user said is in there. Bambu
internal codes are still rejected as non-names (#857).
|
||
|
|
a13e9f0d8e |
Stop waking printers that cannot print the queued job (issue #2876)
The queue's smart-plug step chose a printer to switch on by model alone.
With a class-targeted job and every matching printer off, it walked the
farm in printer-ID order, woke the first machine with an Auto On plug,
and only then read the loaded filament -- so a job for a colour loaded at
the far end of the farm woke every earlier printer in turn and left each
one running until its own auto-power-off timer expired.
The colours were known the whole time. A printer keeps its last reported
AMS and external-spool trays after the power goes; mark_power_off blanks
connected and state and leaves raw_data alone. The wake step now asks the
same three questions the matcher asks a live printer -- required types,
forced colours, preferred colours -- of that reading, and passes over a
printer it rules out. A printer with no reading at all is still woken:
never having heard is not the same as nothing being loaded.
The matcher reports such a printer as needing filament rather than as
offline, so the waiting reason explains why nothing was switched on.
The manager now keeps a printer's last tray reading when it drops the
client, and the queue falls back to that. _power_on_and_wait calls
connect_printer in a retry loop, so an attempt that timed out used to
erase the reading the next one depends on. The record is kept beside the
clients, not inside one: the AMS merge is additive, so feeding it back
into live status would merge an unplugged AMS unit back in for good.
|
||
|
|
aa6723c608 |
Take the layer height from the plate that actually printed
The archive card, the library file details and the slice dialog all read
the layer height from a 3MF's project_settings.config. That records the
project's settings and can still describe an earlier process or another
plate; the plate's own G-code - what the printer executes - was never
consulted for it, because the parser read the first 4KB, enough for the
layer count in the header block but not for the config block that carries
layer_height 14-25KB in. A print running at 0.08 on the H2C archived as
0.2 with the layer count from the same file correct beside it.
The plate G-code now wins wherever the two disagree, and the plate that
was printed is the one read - the header parse used to take the first
gcode entry in the zip regardless of which plate the archive was for.
Source 3MFs, which carry no G-code, keep the project value as before.
---
Stop carrying a file's layer height over the preset you picked
Bambuddy carries a designer's process deviations across a re-slice
(#2622) and pre-ticked every one that was not machine-coupled.
layer_height is one MakerWorld projects routinely carry, so picking
"0.08mm High Quality" for a file whose designer had moved layer height to
0.2 sliced at 0.2 while the dropdown still read 0.08 - the same 0.2 the
settings panel showed, tagged "from file".
Layer height and first layer height are now classified preset_defining
and treated like the machine-coupled keys: offered, never pre-selected.
The flag travels on DesignOverride so the modal and the backend agree,
and the panel's badge names the conflict and shows the preset's own value
next to the file's, so ticking one is a deliberate choice.
|
||
|
|
dbbcf12619 |
Keep the printer's name on statistics after it is deleted (issue #2873)
Every per-printer breakdown resolved the name against the printers that
exist now, so deleting a printer and choosing to keep its prints turned
"Ultron" into "Printer 1" in Prints by Printer, the success-rate and
time-accuracy lists, and Failures by Printer. Archives lose their printer
on that delete as well, so nothing was left to read a name from.
The runs themselves recorded the name they printed on. /archives/stats now
reports the last name each id was known by - taken from the newest run that
has one, so a later name-less row cannot blank it - and failure analysis
falls back to the same thing for ids with no printer left. The client keeps
preferring a live printer's own record, so a rename still shows up straight
away rather than after the next print.
|
||
|
|
c8e794440f |
Restore the skip-objects list after a restart mid-print
The object list lives in PrinterState and is filled by the print-start path,
which bambu_mqtt suppresses on the first RUNNING push after startup so a
running print is not archived twice (#1304). Everything else that moment
restores came back - the archive into _active_prints, the filament
attribution session, the timelapse baseline - and the object list did not.
So the card saw zero objects and greyed out its Skip button for the rest of
the print. Measured on the maintainer's H2C: 8 objects loaded at 09:02, a
restart at 09:17, Skip dead for the remaining hour.
Nothing could bring it back either. GET /print/objects rebuilds the list
whenever it is empty, but its only caller is the modal that the greyed-out
button opens.
on_print_running_observed now reloads the objects from the archive of the
print that is still running, anchored on subtask_id - the firmware mints one
per print, so a leftover status="printing" row from a completion that was
never seen cannot lend its objects to another job. Without an id nothing is
loaded rather than guessed; the endpoint's own reload covers that on demand.
That endpoint now reads the archived 3MF from disk before it asks the
printer. The archive of a running print normally holds the very file the
printer is executing, so the fan-out was fetching back 15 MB Bambuddy
already had, over the printer's single FTP socket, while it was printing -
and on a printer that kept the file on internal storage it cannot succeed at
all. FTP stays as the fallback. skipped_objects is left alone: a reload is
not a new print, and what the user has already skipped only lives there.
The plate image had the same fault one layer down. Opening the modal asks
for the cover, the top view and the object-ID mask, and the in-memory 3MF
cache those share dies with the process - so after a restart all three went
back to the printer at once: three fan-outs, thirteen seconds, and a 0-byte
read from socket contention, which is the storm #972 was about. The cover
flow takes the running print's archived file too, resolved in the caller's
short-lived session and passed in so _produce_cover_image still does no DB
work, and marked as a shared file so the cleanup cannot delete the archive.
Finally the card: a running print always has at least one object, so a count
of zero means "not loaded", not "nothing to skip". Exactly one object is the
real nothing-to-skip case and still disables the button.
---
Stop a test's printer client leaking into the next test
POST /api/v1/printers really connects, so a test that creates a printer
through the API leaves a live client in the printer_manager singleton. The
singleton outlives the per-test in-memory database, so the next test on that
xdist worker - whose own first printer is handed the same primary key - reads
that leftover client as its own live status.
test_scheduled_drying_routes was the visible victim: an "online" printer with
no firmware version fails the drying preflight, so scheduling came back 400
instead of 200. It only bites when --dist load happens to put victim and
leaker on one worker, which is why it passes on its own and flakes under -n.
Registrations made during a test are now undone after it, ids the test did not
add are left alone, and disconnect_printer is what also drops the model and
printer-info caches and stops the paho thread the leaked client was keeping
alive against an unreachable address for the rest of the run.
|
||
|
|
7fa27f83e1 |
Let a print with no 3MF be given its filament weight (issue #1820)
When the sliced file stays somewhere Bambuddy cannot read, the archive is
built from the printer's report alone and carries no weight. Nothing could
supply one afterwards: rescan reads the figure out of the 3MF, and that
archive has no file to read. The reporter's H2S print left 46.16 g on the
spool with nothing recording it, and he corrected Spoolman by hand.
Edit Archive now has a Filament used (g) field. It is written to the
archive's most recent run as well, because the Projects roll-up and the
Prometheus counter sum PrintLogEntry rather than the cards - correcting
only the archive would fix the display and leave every aggregate reading
the old figure, or none at all.
But not over a figure the run measured for itself. A run's grams come from
the tracked spool delta when there is one and only fall back to copying
the archive's estimate when there is not, so mirroring unconditionally
would overwrite a measurement with a typed estimate. The mirror now takes
a run that has no figure, or one holding exactly what this archive held -
which also makes the undo complete, since clearing the archive clears the
copy it made and leaves a measured run alone.
The field is text rather than a number input. A number input reports an
empty string for anything the browser judges malformed, a decimal comma in
a locale that does not expect one included, and that reads here as "the
user cleared it" - it would have wiped a good figure while the field still
showed what was typed. Filtering on the way in keeps what is displayed and
what would be sent the same string, and clamps it to the range the API
accepts: this modal has no error surface, so a refused save looks like
nothing happened at all.
Saving also invalidates the archive's runs query. The Print Log this modal
renders at its top reads them separately and kept serving the pre-edit row,
so a correction looked like it had not taken - true for the status and
failure-reason mirrors since #1444 as well.
Second half of the same report: the internal-storage probe (#2856) logged
which file it found but not where. On a printer that keeps uploads for
weeks - the reporter has months of them in /cache - a reprint of a name
that was re-sliced but never re-sent can match an older copy, and without
the directory that mismatch is invisible rather than merely rare. The
download helper returns the path that served the file instead of a bare
flag; every caller only ever tested it for truth.
|
||
|
|
f3c6e8ff26 |
Release the plate-clear gate on a powered-down printer (issue #2864)
POST /printers/{id}/clear-plate answered 400 "Printer not connected" for
anything without a live MQTT client, and the printer card hid the button
under the same condition. With Auto Power Off that is the ordinary end of
every print: the reporter's log has printer 1 marked offline at 12:00:55
by the plug and the clear-plate POST rejected at 12:03:12, with the plate
already cleared by hand. Nothing could release the gate short of powering
each printer back on, clearing, and switching it off again.
Nothing in the clear path talks to the printer. set_awaiting_plate_clear
writes an in-memory set and the printers.awaiting_plate_clear column, and
that column exists precisely so the gate survives an Auto Off cycle
(#961). The guard came in with the endpoint in
|
||
|
|
3901043238 |
Name an AMS slot's colour by its material, not its hex alone (issue #2875)
A hex is not one colour in Bambu's range. #FFFFFF is Jade White in PLA Basic, Ivory White in PLA Matte and plain White in six other materials; popover resolved its title from the hex alone, against a map that keeps one name per hex, so an ivory Matte spool read "Jade White" while the profile line beside it correctly read Matte Ivory. /inventory/colors/map now carries the names collapsing loses, keyed "<material>|<hex>". An entry is emitted only when it recovers a name the same manufacturer's own range lost -- 11 of them against the 608 colours in the shipped catalog. Both halves matter: a name equal to the flat answer is weight, and a name from another brand is not a recovery, it would put Prusament's "Pristine White" on every generic white PLA slot. A slot with a spool assigned from Inventory is titled with that spool's own colour name: it is the roll the user said is in there. Bambu internal codes are still rejected as non-names (#857). |
||
|
|
dd50c51c1b |
Stop waking printers that cannot print the queued job (issue #2876)
The queue's smart-plug step chose a printer to switch on by model alone. With a class-targeted job and every matching printer off, it walked the farm in printer-ID order, woke the first machine with an Auto On plug, and only then read the loaded filament -- so a job for a colour loaded at the far end of the farm woke every earlier printer in turn and left each one running until its own auto-power-off timer expired. The colours were known the whole time. A printer keeps its last reported AMS and external-spool trays after the power goes; mark_power_off blanks connected and state and leaves raw_data alone. The wake step now asks the same three questions the matcher asks a live printer -- required types, forced colours, preferred colours -- of that reading, and passes over a printer it rules out. A printer with no reading at all is still woken: never having heard is not the same as nothing being loaded. The matcher reports such a printer as needing filament rather than as offline, so the waiting reason explains why nothing was switched on. The manager now keeps a printer's last tray reading when it drops the client, and the queue falls back to that. _power_on_and_wait calls connect_printer in a retry loop, so an attempt that timed out used to erase the reading the next one depends on. The record is kept beside the clients, not inside one: the AMS merge is additive, so feeding it back into live status would merge an unplugged AMS unit back in for good. |
||
|
|
7e77bf5833 |
Take the layer height from the plate that actually printed
The archive card, the library file details and the slice dialog all read the layer height from a 3MF's project_settings.config. That records the project's settings and can still describe an earlier process or another plate; the plate's own G-code - what the printer executes - was never consulted for it, because the parser read the first 4KB, enough for the layer count in the header block but not for the config block that carries layer_height 14-25KB in. A print running at 0.08 on the H2C archived as 0.2 with the layer count from the same file correct beside it. The plate G-code now wins wherever the two disagree, and the plate that was printed is the one read - the header parse used to take the first gcode entry in the zip regardless of which plate the archive was for. Source 3MFs, which carry no G-code, keep the project value as before. --- Stop carrying a file's layer height over the preset you picked Bambuddy carries a designer's process deviations across a re-slice (#2622) and pre-ticked every one that was not machine-coupled. layer_height is one MakerWorld projects routinely carry, so picking "0.08mm High Quality" for a file whose designer had moved layer height to 0.2 sliced at 0.2 while the dropdown still read 0.08 - the same 0.2 the settings panel showed, tagged "from file". Layer height and first layer height are now classified preset_defining and treated like the machine-coupled keys: offered, never pre-selected. The flag travels on DesignOverride so the modal and the backend agree, and the panel's badge names the conflict and shows the preset's own value next to the file's, so ticking one is a deliberate choice. |
||
|
|
28781ea558 |
Keep the printer's name on statistics after it is deleted (issue #2873)
Every per-printer breakdown resolved the name against the printers that exist now, so deleting a printer and choosing to keep its prints turned "Ultron" into "Printer 1" in Prints by Printer, the success-rate and time-accuracy lists, and Failures by Printer. Archives lose their printer on that delete as well, so nothing was left to read a name from. The runs themselves recorded the name they printed on. /archives/stats now reports the last name each id was known by - taken from the newest run that has one, so a later name-less row cannot blank it - and failure analysis falls back to the same thing for ids with no printer left. The client keeps preferring a live printer's own record, so a rename still shows up straight away rather than after the next print. |
||
|
|
cfecfa360e |
Restore the skip-objects list after a restart mid-print
The object list lives in PrinterState and is filled by the print-start path, which bambu_mqtt suppresses on the first RUNNING push after startup so a running print is not archived twice (#1304). Everything else that moment restores came back - the archive into _active_prints, the filament attribution session, the timelapse baseline - and the object list did not. So the card saw zero objects and greyed out its Skip button for the rest of the print. Measured on the maintainer's H2C: 8 objects loaded at 09:02, a restart at 09:17, Skip dead for the remaining hour. Nothing could bring it back either. GET /print/objects rebuilds the list whenever it is empty, but its only caller is the modal that the greyed-out button opens. on_print_running_observed now reloads the objects from the archive of the print that is still running, anchored on subtask_id - the firmware mints one per print, so a leftover status="printing" row from a completion that was never seen cannot lend its objects to another job. Without an id nothing is loaded rather than guessed; the endpoint's own reload covers that on demand. That endpoint now reads the archived 3MF from disk before it asks the printer. The archive of a running print normally holds the very file the printer is executing, so the fan-out was fetching back 15 MB Bambuddy already had, over the printer's single FTP socket, while it was printing - and on a printer that kept the file on internal storage it cannot succeed at all. FTP stays as the fallback. skipped_objects is left alone: a reload is not a new print, and what the user has already skipped only lives there. The plate image had the same fault one layer down. Opening the modal asks for the cover, the top view and the object-ID mask, and the in-memory 3MF cache those share dies with the process - so after a restart all three went back to the printer at once: three fan-outs, thirteen seconds, and a 0-byte read from socket contention, which is the storm #972 was about. The cover flow takes the running print's archived file too, resolved in the caller's short-lived session and passed in so _produce_cover_image still does no DB work, and marked as a shared file so the cleanup cannot delete the archive. Finally the card: a running print always has at least one object, so a count of zero means "not loaded", not "nothing to skip". Exactly one object is the real nothing-to-skip case and still disables the button. --- Stop a test's printer client leaking into the next test POST /api/v1/printers really connects, so a test that creates a printer through the API leaves a live client in the printer_manager singleton. The singleton outlives the per-test in-memory database, so the next test on that xdist worker - whose own first printer is handed the same primary key - reads that leftover client as its own live status. test_scheduled_drying_routes was the visible victim: an "online" printer with no firmware version fails the drying preflight, so scheduling came back 400 instead of 200. It only bites when --dist load happens to put victim and leaker on one worker, which is why it passes on its own and flakes under -n. Registrations made during a test are now undone after it, ids the test did not add are left alone, and disconnect_printer is what also drops the model and printer-info caches and stops the paho thread the leaked client was keeping alive against an unreachable address for the rest of the run. |
||
|
|
d227d42272 |
Let a print with no 3MF be given its filament weight (issue #1820)
When the sliced file stays somewhere Bambuddy cannot read, the archive is built from the printer's report alone and carries no weight. Nothing could supply one afterwards: rescan reads the figure out of the 3MF, and that archive has no file to read. The reporter's H2S print left 46.16 g on the spool with nothing recording it, and he corrected Spoolman by hand. Edit Archive now has a Filament used (g) field. It is written to the archive's most recent run as well, because the Projects roll-up and the Prometheus counter sum PrintLogEntry rather than the cards - correcting only the archive would fix the display and leave every aggregate reading the old figure, or none at all. But not over a figure the run measured for itself. A run's grams come from the tracked spool delta when there is one and only fall back to copying the archive's estimate when there is not, so mirroring unconditionally would overwrite a measurement with a typed estimate. The mirror now takes a run that has no figure, or one holding exactly what this archive held - which also makes the undo complete, since clearing the archive clears the copy it made and leaves a measured run alone. The field is text rather than a number input. A number input reports an empty string for anything the browser judges malformed, a decimal comma in a locale that does not expect one included, and that reads here as "the user cleared it" - it would have wiped a good figure while the field still showed what was typed. Filtering on the way in keeps what is displayed and what would be sent the same string, and clamps it to the range the API accepts: this modal has no error surface, so a refused save looks like nothing happened at all. Saving also invalidates the archive's runs query. The Print Log this modal renders at its top reads them separately and kept serving the pre-edit row, so a correction looked like it had not taken - true for the status and failure-reason mirrors since #1444 as well. Second half of the same report: the internal-storage probe (#2856) logged which file it found but not where. On a printer that keeps uploads for weeks - the reporter has months of them in /cache - a reprint of a name that was re-sliced but never re-sent can match an older copy, and without the directory that mismatch is invisible rather than merely rare. The download helper returns the path that served the file instead of a bare flag; every caller only ever tested it for truth. |
||
|
|
05d87a9740 |
Release the plate-clear gate on a powered-down printer (issue #2864)
POST /printers/{id}/clear-plate answered 400 "Printer not connected" for
anything without a live MQTT client, and the printer card hid the button
under the same condition. With Auto Power Off that is the ordinary end of
every print: the reporter's log has printer 1 marked offline at 12:00:55
by the plug and the clear-plate POST rejected at 12:03:12, with the plate
already cleared by hand. Nothing could release the gate short of powering
each printer back on, clearing, and switching it off again.
Nothing in the clear path talks to the printer. set_awaiting_plate_clear
writes an in-memory set and the printers.awaiting_plate_clear column, and
that column exists precisely so the gate survives an Auto Off cycle
(#961). The guard came in with the endpoint in
|
||
|
|
600bf8e24e | Bumped version && updated CHANGELOG | ||
|
|
2d24ef4bd8 |
Check the card before writing a print off as internal-storage-only (issue #2856)
A print's dispatch says where the printer put the sliced file:
ftp://<name> for external storage, brtc://emmc/<name> for internal. Since
that there is then no file to find at any path.
That is where the printer chose to put it, which is not the same as where
port 990 can read it. The reporter's H2D - firmware 01.03.00.00, card in
the slot - reports brtc://emmc and keeps the same file under /cache: his
log has every print from 08-12 downloading from there, 19 MB included,
until the skip landed and two days of archives came out as a name and
nothing else. #2780's P2S and H2C really did 550 on every path, so both
are true and the URL alone cannot tell them apart.
So ask the printer rather than the model. The dispatch names the exact
file, which turns the question into one connection walking five
directories - against the sweep's ~110, which is the cost that made
skipping worth doing. A hit archives normally and is shared with the
cover endpoint; a miss keeps #2780's fallback archive and its reason, so
the archives banner still explains itself. Not probed when the printer
reports an empty slot, or while its file service is in TLS cool-off:
both have already answered the question.
The connection diagnostic asked the same question off the URL and warned
that the last print was out of reach. On this reporter's printer that
warning would have sent him to a setting that was already right, so it
now probes too - by directory listing, since the file it is asking about
can be tens of megabytes and the answer is a yes or a no. Capped at 6s to
stay inside the support bundle's per-printer budget, and "could not
check" leaves the warning standing.
The probe filename arrives over MQTT and becomes both a remote path and a
local temp filename, so names carrying separators, traversal or control
characters are declined rather than cleaned.
|
||
|
|
5665babab4 |
Use the printer's own plug for energy when several are linked (issue #2859)
Per-print energy is one plug's meter read at the start of a print and
again at the end. Both readings asked for "the plug on this printer"
with scalar_one_or_none(), which raises on two rows. Linking a second
plug to a printer - a dry box, a filter fan, a lights script - therefore
stopped energy tracking on that printer outright, and did it silently:
the print-start handler logged the exception as an ordinary failure and
the print-end handler then reported "no start kWh recorded", which is
also what it says for a printer with nothing linked to it.
The assumption was never enforced anywhere else. The plug API rejects a
second Tasmota plug and deliberately allows any number of Home Assistant
entities, the UNIQUE constraint on smart_plugs.printer_id was dropped on
purpose, and every other consumer reads a list. These two call sites were
the last ones left from before that.
Energy now ranks a printer's plugs - the one that powers it first, then
by id so the start and end readings agree - and takes the first that
actually reports a counter, so accessories drop out with nothing
configured. Ranking rather than filtering: a printer whose only linked
row is disabled, or a script, used it before and still does. When none
of them measures anything the log names the ones it tried, so that stops
reading like "no plug configured".
Also: the plug page counted an online plug as offline unless it reported
energy, so a switch with no power sensor showed as offline for as long
as it stayed linked.
Existing archives cannot be backfilled - the starting reading was never
taken, so there is nothing to compute a delta from.
|
||
|
|
ad644bca48 |
Look for a print's file when the printer says it is on the card
(#2780 regression) A print of a file already on the printer -- a reprint from the touchscreen, from Handy, or a slicer send-to-storage followed by a print -- reports its location as a path rather than as a fresh upload: file:///media/usb0/<name>. Since #2780 landed on 2026-08-14 Bambuddy read anything that was not ftp:// as "the printer kept this internally", skipped the FTPS sweep, and archived the print with a name and timing only. Measured on an H2D: the file was listable and downloadable over FTPS at the moment Bambuddy declared it unreachable. Before that change those prints archived normally, so this is a regression, and it is not confined to the H2 series the change was about -- an X1C reprint from its own screen loses its thumbnail exactly the same way. That module's own rule is to skip only on positive evidence, and a file:// path is not evidence of internal storage. It now reads the path: the printer's model cache under /userdata is a genuine skip, anything else is unknown and sweeps, which is what it did before. Unknown rather than external on purpose -- the empty-slot check still runs ahead of it, so a file:// print on a printer with nothing in the slot reports the missing card instead of sweeping for something that cannot be there. The user-facing copy shipped this morning is corrected in the same change, because it was written before we understood how Bambu Studio actually chooses. Its Print button always uses internal memory; only Send offers Cache or External, and that defaults to Cache too. So the advice now leads with the two routes that take one step -- start the print from Bambuddy, or slice in OrcaSlicer -- and offers Send-with-External and a separate print start as the way to stay in Bambu Studio. The earlier wording named no remedy at all and blamed the printer's firmware for a choice the slicer makes. Banner and diagnostic, thirteen locales, README, bundle rebuilt. |
||
|
|
e5b8e76ea1 |
Recognise our own print dispatch instead of guessing at a magic number
(#2843 follow-up) Bambuddy records the project_file behind every print, because that command names where the sliced file was put and so decides whether the archive can have a thumbnail and slicer metadata at all. Its own dispatches were told apart from a slicer's by testing sequence_id against "20000", on the belief that 20000 was Bambuddy's alone. It never was. 20000 is the slicer convention Bambuddy copied -- virtual_printer/bind_server documents the slicer sending exactly that during detect -- and both slicers count up from it. Measured on the wire: OrcaSlicer dispatched 20000 and then 20001, BambuStudio 20009 and 20010. So whichever dispatch happened to land on the shared value was filed as ours and never recorded, and after a slicer restart that is the first print you send. The test was wrong in the other direction too: it called every value above 20000 external, including ones we had sent ourselves, which only stayed invisible because we always send exactly 20000. Ownership is now established by remembering the job actually dispatched -- sequence id, file, url and subtask name -- and consuming that marker on the echo. One-shot deliberately: a slicer reprint of the same file a moment later is somebody else's print and must not hide behind our last one. Nothing about printing or archiving changes. current_project_url and ams_mapping are both captured before this branch and always were, so the storage verdict that gates the FTPS sweep is untouched; two tests pin that, because it is the part that would actually cost archives if it drifted. What changes is that the diagnostic entry stops lying, and it is the entry that tells an operator whether their printer stores files somewhere Bambuddy can read -- which is the whole subject of #2780 and would have to count, and an undercount there would have been silent. |
||
|
|
2b38cff16d |
Stop a print with no 3MF borrowing another model's data (#2843)
H2-series and P2S firmware keeps a slicer-sent file on internal eMMC.
Port 990 serves external storage only, so there is no file to fetch, and
the print becomes an archive with no 3MF -- the ordinary outcome for
anyone who sends from Bambu Studio rather than through Bambuddy.
Confirmed on the maintainer's own machines: an H2C and an H2D both
dispatched brtc://emmc for the same model one minute apart, while an X1C
sent ftp:// for it. Three separate defects live in what happens next.
The first is the serious one. An archive with no 3MF keeps the path the
printer is executing as its filename, and on a sliced job that is always
Metadata/plate_1.gcode. The fallback that looks for the same model in the
Library or among earlier prints took its search term from there, so it
searched for `plate_1` -- a name every Bambu print in existence has --
and matched on a substring, so it also matched any name merely ending
that way. On the H2D a 1.6 g Cube resolved to lid_plate_1.gcode.3mf and
was costed at 207 g across three real spools. It was not confined to
plate names either: in the same database `Bank.3mf` matched "Piggo the
piggy bank", and `x1c.gcode.3mf` matched "slice-test-x1c". The matcher
now takes the model name the printer reports when the filename is only a
plate path, refuses a bare plate stem rather than searching for it, and
anchors to a whole filename with LIKE metacharacters escaped, because `_`
is a wildcard and model names are full of them. A print that cannot be
identified is now left untracked, which is the honest answer -- the
previous behaviour was to charge the operator's spools for a model they
had not printed.
Checked against every row rather than argued from the code. Across 273
library stems the result sets are identical. Across 241 archive stems 14
differ, all of them strictly narrower, and every dropped match is one of
the false positives above; all 233 archives still match their own
filename, so no legitimate donor was lost. Of the eight no-3MF archives
on that install the old matcher picked a wrong donor for two -- one of
them a calibration run that would have been charged the 207 g -- and the
new one picks none.
The second defect is that those archives could not receive a timelapse at
all. attach_timelapse derived its destination from the missing file's
path, and (base_dir / "").parent is the parent of base_dir, one level
outside the data directory. In Docker that is /app, so every attempt
failed EACCES and the scan retried and discarded the video 25 times over
twelve minutes, roughly a hundred FTPS connections for bytes that had
already downloaded successfully. Where that location happened to be
writable it was worse: the file landed beside the installation and the
attach then failed anyway, because the path could not be made relative to
base_dir. #1820 introduced a shared helper precisely so these derivations
could not drift apart, and this was the one site still doing it by hand.
The directory is created only after the filename has passed the traversal
check, so a rejected name still leaves nothing behind.
The third is silence. When a print's filament cannot be read from a 3MF,
the remaining-percentage delta is the fallback, and that needs a reading
at print start -- which a spool without RFID does not have until someone
sets a remaining amount by hand. Those slots were skipped with a bare
continue. Every other reason for skipping a slot in that loop is logged,
and the comment a few lines below argues the case explicitly: charging
nothing silently is indistinguishable from having nothing to charge. It
now says so, for slots the print actually used.
Four existing tests needed updating rather than the production path.
They patch backend.app.services.archive.settings by name, and the shared
helper reads its own module-level binding, so they kept the real data
directory and wrote outside tmp_path -- which is how the first draft of
this change littered a working tree. They now patch both bindings.
|
||
|
|
f855d8dcca |
Pin the PostgreSQL session to UTC so defaulted timestamps are UTC (#2855)
On a UTC+3 install every AMS humidity reading and every archive was
stamped three hours ahead of when it happened. Bambuddy stores naive
timestamps that hold UTC and the frontend's parseUTCDate reads an
offsetless timestamp as UTC, so the display added the offset to a value
that was already local.
The Python side has honoured that contract since #504. The reporter's
timestamps were not written by Python. Around ninety-six columns take
their value from server_default=func.now() and the migration DDL carries
another forty-nine on DEFAULT CURRENT_TIMESTAMP -- the database fills
those, and on PostgreSQL now() is a timestamptz, so storing it into a
timestamp without time zone casts it through the session TimeZone. A
Postgres container started with TZ=Europe/Istanbul bakes that zone into
postgresql.conf at initdb, and every defaulted column then receives local
wall-clock. recorded_at is the clearest case: nothing in the codebase
ever assigns it, so its value is entirely whatever the database decided.
Connections now carry timezone=UTC, which makes the cast a no-op whatever
the server is set to. Measured through the real engine factory against a
live PostgreSQL, a session on the reporter's configuration stored +10800s
and the fixed one +0s. Pinning the session was preferred over a hundred
and forty-five individual edits partly for its size but mostly because
half of those sites are raw DDL that no model-level change can reach.
SQLite needed nothing and gets nothing: its CURRENT_TIMESTAMP is UTC by
definition and it has no session timezone to get wrong, which is why this
survived two years of timezone fixes without showing itself. That also
makes it the reference -- the change moves Postgres onto SQLite's
behaviour rather than introducing a third convention -- so the SQLite
behaviour is now pinned by a test instead of being assumed. asyncpg is
the documented driver and takes the setting in its startup packet; any
other Postgres driver gets the same setting the libpq way, so a psycopg
URL does not fail at connect on a keyword asyncpg alone accepts.
Rows already written are deliberately left alone. The inverse cast is
computable and DST-correct, but it cannot be applied safely: created_at
is assigned explicitly on some paths and defaulted on others, an install
that began on SQLite holds correct and shifted rows side by side, and
nothing distinguishes them after the fact. Timestamps are right from the
upgrade forward and history keeps the times it was given.
One related mismatch goes with it, because fixing the database side alone
would have made it start lying on exactly the installs this repairs. The
support package's oldest_pending_age_seconds subtracted a naive local
clock from a naive UTC column, with a comment claiming it was UTC; on the
reporter's install the two errors cancelled. It reported a job queued
five minutes ago as three hours old east of Greenwich and a negative age
west of it. The two AMS and printer-sensor retention cutoffs move to the
same utcnow_naive helper -- correct in value already, but deprecated in
3.12 and emitting warnings on every sweep.
|
||
|
|
019fb1c8af |
Track which nozzle each AMS feeds through the Filament Track Switch
With a switch fitted, an AMS is not wired to a nozzle any more. It is
plumbed into one of the switch's two inlets and reaches both nozzles
through it, so every unit reports its extruder as "not fixed" (0xE) and
ams_extruder_map comes back empty. Bambuddy had nothing to fall back on
but the AMS unit number, so AMS-A was badged R and AMS-B was badged L
purely because their unit ids are 0 and 1, a third unit got no badge at
all, and every one of those labels was wrong.
The binding needed no new telemetry. BambuStudio reads it out of bits
24-27 of the same AMS info string we already parse for the type and the
extruder id -- 0 is In-B, 1 is In-A -- and it only means anything when a
switch is installed, because without one 0xE really does mean an
uninitialised unit. That gates the read, which forced the switch block to
be parsed before the AMS block: _handle_ams_data runs early in
_process_message and _update_state only much later, so the binding was
lost on every frame that carried both.
The badge letters stay L and R, In-A reading as L, with the inlet named
in full in the tooltip -- the letter is the inlet's position and not a
claim about which nozzle that AMS feeds, since the switch can route
either inlet to either outlet. Both views update live now. The switch
fields were missing from the WebSocket payload, and the frontend
shallow-merges each push over its cached status, so an absent field kept
whatever the last full fetch left behind. The broadcast dedup key had no
term for them either, so "Join IN-B" on the printer screen moved nothing:
the binding is not in the tray component of that key, and not in the AMS
change-hash, which covers tray fields only and must stay that way because
it drives Spoolman sync.
The rest of this is the calibration half, which is where it actually
bites. K-profiles are calibrated per nozzle and the printer numbers its
calibration table per nozzle too, so entry 16 exists on both hotends and
means a different profile on each. A tray holds exactly one index. Move
an AMS to the other inlet and every configured slot in it silently keeps
pointing at the old hotend's table -- measured on the maintainer's H2C, a
black PLA calibrated 0.018 left and 0.020 right stayed on the left
profile after the move, and a manual RFID re-read only re-asserted the
same wrong one. Bambu has not solved this either; their AMS dialog
carries "TODO: fila_switcher broken the connection of ams->extruder"
above the line that decides which nozzle's profiles to offer.
Three copies of "which extruder is this slot on" each ended in else 0,
which on a switch machine filed every profile under the right-hand
nozzle. They now share one resolver that returns None for "unknown",
because unknown and extruder 0 are very different answers on a
dual-nozzle machine and conflating them is what bound a left-nozzle
profile to a slot sitting on the right. The per-slot K value on the
printer card had the same confusion from the other direction: its lookup
was keyed on cali_idx alone, so one nozzle's K silently overwrote the
other's.
Moving an AMS now re-selects each configured slot's counterpart profile
for the nozzle it has arrived on. Only the calibration binding moves, and
only for slots whose spool already has a profile for that nozzle:
configuring a slot is a deliberate preparation step, so a slot we know
nothing about, or a spool calibrated on one hotend only, is left exactly
as the operator set it. Nothing fires on the first sighting of a binding
either, since every reconnect learns them afresh and re-applying there
would overwrite a choice made by hand.
Configure Slot resolves against the slot's own nozzle throughout. Option
identity carries the extruder, so a filament calibrated on both hotends
gives two distinguishable entries instead of two that collapse into
whichever the printer listed first; options name the hotend; matches are
scoped to the nozzle the slot feeds, with the other hotend's profiles
still reachable under Other K profiles; and the slot's active index is
resolved as a pair rather than followed into the wrong table.
Inlet to nozzle is one table, In-A to the left hotend and In-B to the
right, measured rather than assumed -- fila_switch.out cannot be used for
it, reporting [1, 1] unchanged across a 90-second capture, both outlets
claiming the same extruder. The print dialog picks up the same inlet
labelling in its slot dropdown, replacing a left/right hint that never
rendered because it matched snow-encoded values against global tray ids;
decoding it correctly would not have saved it, since the firmware never
reports which inlet is currently paired with which outlet. The dialog
also notes when every filament a print needs sits behind one inlet, which
is legal but slow -- a change between two filaments on the same inlet
retracts the outgoing spool all the way back to its AMS, where a change
across the two only retracts as far as the switch.
Assigning an AMS to an inlet remains printer-side. BambuStudio can read
that binding and has no command to write it, so there is no wire format
to copy.
|
||
|
|
a0778f931b |
Show which Filament Track Switch inlet each AMS feeds
With a switch fitted, an AMS is not wired to a nozzle any more. It is
plumbed into one of the switch's two inlets and reaches both nozzles
through it, so every unit reports its extruder as "not fixed" (0xE) and
ams_extruder_map comes back empty on these machines.
The printer card had nothing to fall back on but the AMS unit number, so
AMS-A was badged R and AMS-B was badged L purely because their unit ids
are 0 and 1, a third unit got no badge at all, and every one of those
labels was wrong. The SpoolBuddy assign modal had the same fallback in a
worse form, mapping anything that was not extruder 1 to R.
The binding turned out to need no new telemetry. BambuStudio reads it out
of bits 24-27 of the same AMS info string we already parse for the AMS
type and the extruder id -- 0 is In-B, 1 is In-A -- and it is only
meaningful when a switch is installed, because without one 0xE really
does mean an uninitialised unit and those bits carry nothing. That gates
the read, which in turn forced the switch block to be parsed before the
AMS block: _handle_ams_data runs early in _process_message and
_update_state only much later, so the binding was lost on every frame
that carried both. _parse_fila_switch is split out and called first, and
left in _update_state as well so that stays a complete absorb step.
The badge keeps L and R rather than A and B, because the lettering is
familiar and matches the physical layout. It is a different colour from
the plain nozzle badge, and its tooltip names the inlet in full, since
the letter is the inlet's position and not a claim about which nozzle
that AMS feeds -- the switch can route either inlet to either outlet. An
AMS still reporting a real extruder id keeps its ordinary badge, which
BambuStudio also treats as authoritative over any switch binding, and a
switch that has been fitted but not yet set up on the printer shows
nothing rather than a guess.
The print dialog's slot dropdown gets the same label. It replaces a
left/right hint that never once rendered: ftsExtruderForSlot compared
snow-encoded in[] values against global tray ids and could not match.
Decoding it correctly would not have saved it -- the firmware reports
which slot sits in each inlet and which nozzle each outlet feeds, but
never which inlet is currently paired with which outlet, so no per-slot
nozzle can be derived. That function is gone rather than fixed.
The dialog also points out when every filament a print needs sits behind
one inlet. Bambu's own guidance is that this is legal but slow: a change
between two filaments on the same inlet retracts the outgoing spool all
the way back to its AMS before the next can be fed up the shared tube,
where a change across the two inlets only retracts as far as the switch.
All on one inlet means every change in the job takes the slow path, and
moving a single spool fixes it. So it advises, it does not block.
Both views update live. Two things were stopping that. fila_switch and
ams_switch_inlet were absent from printer_state_to_dict, and the frontend
shallow-merges each WebSocket push over its cached status, so a field the
push omits keeps whatever the last full fetch left behind. And the
broadcast dedup key had no term for either, so "Join IN-B" on the printer
screen moved nothing: the binding is not in the tray component of that
key, and it is not in the AMS change-hash either, which covers tray
fields only and must stay that way because it drives Spoolman sync.
Assigning an AMS to an inlet remains printer-side. BambuStudio can read
the binding and has no command to write it -- its switch class is parse
and getters only, and the recommended-arrangement popup draws and
publishes nothing -- so there is no wire format for us to copy.
Adding the two fields to PrinterState broke four test modules whose
SimpleNamespace stubs predate them. The stubs are fixed rather than the
production reads made defensive: the real dataclass always carries both,
and a getattr in the dedup key would silently stop tracking the field if
it were ever renamed.
|
||
|
|
88feb69bc3 |
Stop auto K-profile calibration leaving an archive behind
With flow dynamics calibration on, the printer lays down a
pressure-advance line before the print itself and announces it over MQTT
through the same print-start event a real print uses. Bambuddy archived
it: a row named auto_pa_line_calib_mode marked as having no 3MF, sitting
in among the user's actual prints, with a Print Started and a Print
Completed notification for each one.
The printer's other internal jobs were already skipped, but only by the
/usr/ path they carry -- bed levelling reports as
/usr/etc/print/auto_cali_for_user.gcode. The pressure-advance line
carries no path at all. It arrives as a bare subtask name, so a rule
that only ever looked at the filename could not see it. Falling past the
guard it reached the no-3MF fallback, where print_name is subtask_name
or filename, and named the row after the calibration.
Internal jobs are now recognised by name as well as by path, from either
field, in one place both callbacks share. The match is exact after
normalising away the directory, one print-file suffix and case, rather
than a prefix or substring rule: "auto" and "calib" are ordinary words in
a user's own filenames, and a rule loose enough to catch some unnamed
future calibration would quietly swallow somebody's print.
The completion is suppressed too, and that half matters more than the
noise. With no archive to close, the completion falls into the
no-archive notification path -- which attributes an unmatched completion
to any queue item the printer finished in the last five minutes and
emails its owner. This calibration runs alongside a real print, so
silencing only the start would have told that print's owner their job
was done, early, and again for real later. The guard sits inside the
no-archive branch, so the plate-clear gate, the queue reconciliation and
the SD-card cleanup all still run; only the notification is skipped.
Skipping the run early also drops the FTP sweep that preceded the
fallback -- six candidate names across five directories with retries,
around a hundred connections looking for a file that cannot exist, aimed
at a printer that is in the middle of calibrating.
auto_cali_for_user no longer sends a Print Started notification either.
It is the same event about the same kind of job, and the archive was
never the only thing wrong with treating it as a user's print.
|
||
|
|
64a1defa7a |
Stop the AMS temperature alert firing for heat the user asked for (#1802)
The alert compares against ams_temp_fair, the same threshold that colours
the printer card, which defaults to 35C. Drying deliberately runs at 45C
for PLA, 65C for PETG and up to 85C on an AMS-HT, and the alert repeats
once an hour for as long as the condition holds, so a twelve-hour dry
sent twelve notifications about a temperature the user chose. It then
kept sending them while the unit cooled back down, which is the half the
reporter confirmed on an AMS 2 Pro and an H2C.
Dispatch now consults the drying state the firmware already reports.
dry_time alone is not enough: it reads 0 through the cooling phase that
closes a cycle, so dry_status -- info bits 4-7, already parsed for the
drying-complete edge -- carries the rest. That constant moves out of
bambu_mqtt into a leaf util rather than being duplicated; drying_preflight
would have been the natural home, but it imports printer_manager, which
imports bambu_mqtt, and bambu_mqtt is one of the callers.
The cool-down afterwards is held by a latch released as soon as the unit
reads back at or below the threshold, rather than after a fixed delay, so
a 65C cycle in a cold basement and a 45C one in a warm room each get the
time they actually need. A two-hour cap bounds the one case the latch
cannot resolve on its own -- a unit that never returns below the
threshold -- and since such a unit would have been alarming with no
drying involved, releasing there restores the ordinary behaviour instead
of inventing a new alert.
Two exclusions are deliberate. Humidity is untouched, because during
drying that reading falling is the whole point. And dry_status 6,
HeatOutOfControl, is kept out of the active set: an AMS that has lost
thermal control is exactly when the alert should still arrive, so it must
never read as expected heat.
A cycle plus its cool-down outlasts a restart, so the latch is a settings
row rather than a dict beside _ams_alarm_cooldown -- the internal
timestamp-row pattern support.py already uses. It is read once per pass
and written back only when a unit changed it. Stamps ahead of now are
clamped on read, since a box whose clock jumps backwards writes them and
suppression is measured as now minus the stamp; without the clamp the cap
would measure from a moment that has not happened yet and hold the alert
quiet for the skew on top of it.
No new setting. The reporter was offered the opt-out checkbox they asked
for and said they would not want it if the alert simply never fired
during drying.
|
||
|
|
607b34e94d |
Check the card before writing a print off as internal-storage-only (issue #2856)
A print's dispatch says where the printer put the sliced file: ftp://<name> for external storage, brtc://emmc/<name> for internal. Since that there is then no file to find at any path. That is where the printer chose to put it, which is not the same as where port 990 can read it. The reporter's H2D - firmware 01.03.00.00, card in the slot - reports brtc://emmc and keeps the same file under /cache: his log has every print from 08-12 downloading from there, 19 MB included, until the skip landed and two days of archives came out as a name and nothing else. #2780's P2S and H2C really did 550 on every path, so both are true and the URL alone cannot tell them apart. So ask the printer rather than the model. The dispatch names the exact file, which turns the question into one connection walking five directories - against the sweep's ~110, which is the cost that made skipping worth doing. A hit archives normally and is shared with the cover endpoint; a miss keeps #2780's fallback archive and its reason, so the archives banner still explains itself. Not probed when the printer reports an empty slot, or while its file service is in TLS cool-off: both have already answered the question. The connection diagnostic asked the same question off the URL and warned that the last print was out of reach. On this reporter's printer that warning would have sent him to a setting that was already right, so it now probes too - by directory listing, since the file it is asking about can be tens of megabytes and the answer is a yes or a no. Capped at 6s to stay inside the support bundle's per-printer budget, and "could not check" leaves the warning standing. The probe filename arrives over MQTT and becomes both a remote path and a local temp filename, so names carrying separators, traversal or control characters are declined rather than cleaned. |
||
|
|
5a05e03c8e |
Use the printer's own plug for energy when several are linked (issue #2859)
Per-print energy is one plug's meter read at the start of a print and again at the end. Both readings asked for "the plug on this printer" with scalar_one_or_none(), which raises on two rows. Linking a second plug to a printer - a dry box, a filter fan, a lights script - therefore stopped energy tracking on that printer outright, and did it silently: the print-start handler logged the exception as an ordinary failure and the print-end handler then reported "no start kWh recorded", which is also what it says for a printer with nothing linked to it. The assumption was never enforced anywhere else. The plug API rejects a second Tasmota plug and deliberately allows any number of Home Assistant entities, the UNIQUE constraint on smart_plugs.printer_id was dropped on purpose, and every other consumer reads a list. These two call sites were the last ones left from before that. Energy now ranks a printer's plugs - the one that powers it first, then by id so the start and end readings agree - and takes the first that actually reports a counter, so accessories drop out with nothing configured. Ranking rather than filtering: a printer whose only linked row is disabled, or a script, used it before and still does. When none of them measures anything the log names the ones it tried, so that stops reading like "no plug configured". Also: the plug page counted an online plug as offline unless it reported energy, so a switch with no power sensor showed as offline for as long as it stayed linked. Existing archives cannot be backfilled - the starting reading was never taken, so there is nothing to compute a delta from. |
||
|
|
2c7df27d1a |
Look for a print's file when the printer says it is on the card
(#2780 regression) A print of a file already on the printer -- a reprint from the touchscreen, from Handy, or a slicer send-to-storage followed by a print -- reports its location as a path rather than as a fresh upload: file:///media/usb0/<name>. Since #2780 landed on 2026-08-14 Bambuddy read anything that was not ftp:// as "the printer kept this internally", skipped the FTPS sweep, and archived the print with a name and timing only. Measured on an H2D: the file was listable and downloadable over FTPS at the moment Bambuddy declared it unreachable. Before that change those prints archived normally, so this is a regression, and it is not confined to the H2 series the change was about -- an X1C reprint from its own screen loses its thumbnail exactly the same way. That module's own rule is to skip only on positive evidence, and a file:// path is not evidence of internal storage. It now reads the path: the printer's model cache under /userdata is a genuine skip, anything else is unknown and sweeps, which is what it did before. Unknown rather than external on purpose -- the empty-slot check still runs ahead of it, so a file:// print on a printer with nothing in the slot reports the missing card instead of sweeping for something that cannot be there. The user-facing copy shipped this morning is corrected in the same change, because it was written before we understood how Bambu Studio actually chooses. Its Print button always uses internal memory; only Send offers Cache or External, and that defaults to Cache too. So the advice now leads with the two routes that take one step -- start the print from Bambuddy, or slice in OrcaSlicer -- and offers Send-with-External and a separate print start as the way to stay in Bambu Studio. The earlier wording named no remedy at all and blamed the printer's firmware for a choice the slicer makes. Banner and diagnostic, thirteen locales, README, bundle rebuilt. |
||
|
|
89ea337612 |
Recognise our own print dispatch instead of guessing at a magic number
(#2843 follow-up) Bambuddy records the project_file behind every print, because that command names where the sliced file was put and so decides whether the archive can have a thumbnail and slicer metadata at all. Its own dispatches were told apart from a slicer's by testing sequence_id against "20000", on the belief that 20000 was Bambuddy's alone. It never was. 20000 is the slicer convention Bambuddy copied -- virtual_printer/bind_server documents the slicer sending exactly that during detect -- and both slicers count up from it. Measured on the wire: OrcaSlicer dispatched 20000 and then 20001, BambuStudio 20009 and 20010. So whichever dispatch happened to land on the shared value was filed as ours and never recorded, and after a slicer restart that is the first print you send. The test was wrong in the other direction too: it called every value above 20000 external, including ones we had sent ourselves, which only stayed invisible because we always send exactly 20000. Ownership is now established by remembering the job actually dispatched -- sequence id, file, url and subtask name -- and consuming that marker on the echo. One-shot deliberately: a slicer reprint of the same file a moment later is somebody else's print and must not hide behind our last one. Nothing about printing or archiving changes. current_project_url and ams_mapping are both captured before this branch and always were, so the storage verdict that gates the FTPS sweep is untouched; two tests pin that, because it is the part that would actually cost archives if it drifted. What changes is that the diagnostic entry stops lying, and it is the entry that tells an operator whether their printer stores files somewhere Bambuddy can read -- which is the whole subject of #2780 and would have to count, and an undercount there would have been silent. |
||
|
|
6488a33488 |
Stop a print with no 3MF borrowing another model's data (#2843)
H2-series and P2S firmware keeps a slicer-sent file on internal eMMC. Port 990 serves external storage only, so there is no file to fetch, and the print becomes an archive with no 3MF -- the ordinary outcome for anyone who sends from Bambu Studio rather than through Bambuddy. Confirmed on the maintainer's own machines: an H2C and an H2D both dispatched brtc://emmc for the same model one minute apart, while an X1C sent ftp:// for it. Three separate defects live in what happens next. The first is the serious one. An archive with no 3MF keeps the path the printer is executing as its filename, and on a sliced job that is always Metadata/plate_1.gcode. The fallback that looks for the same model in the Library or among earlier prints took its search term from there, so it searched for `plate_1` -- a name every Bambu print in existence has -- and matched on a substring, so it also matched any name merely ending that way. On the H2D a 1.6 g Cube resolved to lid_plate_1.gcode.3mf and was costed at 207 g across three real spools. It was not confined to plate names either: in the same database `Bank.3mf` matched "Piggo the piggy bank", and `x1c.gcode.3mf` matched "slice-test-x1c". The matcher now takes the model name the printer reports when the filename is only a plate path, refuses a bare plate stem rather than searching for it, and anchors to a whole filename with LIKE metacharacters escaped, because `_` is a wildcard and model names are full of them. A print that cannot be identified is now left untracked, which is the honest answer -- the previous behaviour was to charge the operator's spools for a model they had not printed. Checked against every row rather than argued from the code. Across 273 library stems the result sets are identical. Across 241 archive stems 14 differ, all of them strictly narrower, and every dropped match is one of the false positives above; all 233 archives still match their own filename, so no legitimate donor was lost. Of the eight no-3MF archives on that install the old matcher picked a wrong donor for two -- one of them a calibration run that would have been charged the 207 g -- and the new one picks none. The second defect is that those archives could not receive a timelapse at all. attach_timelapse derived its destination from the missing file's path, and (base_dir / "").parent is the parent of base_dir, one level outside the data directory. In Docker that is /app, so every attempt failed EACCES and the scan retried and discarded the video 25 times over twelve minutes, roughly a hundred FTPS connections for bytes that had already downloaded successfully. Where that location happened to be writable it was worse: the file landed beside the installation and the attach then failed anyway, because the path could not be made relative to base_dir. #1820 introduced a shared helper precisely so these derivations could not drift apart, and this was the one site still doing it by hand. The directory is created only after the filename has passed the traversal check, so a rejected name still leaves nothing behind. The third is silence. When a print's filament cannot be read from a 3MF, the remaining-percentage delta is the fallback, and that needs a reading at print start -- which a spool without RFID does not have until someone sets a remaining amount by hand. Those slots were skipped with a bare continue. Every other reason for skipping a slot in that loop is logged, and the comment a few lines below argues the case explicitly: charging nothing silently is indistinguishable from having nothing to charge. It now says so, for slots the print actually used. Four existing tests needed updating rather than the production path. They patch backend.app.services.archive.settings by name, and the shared helper reads its own module-level binding, so they kept the real data directory and wrote outside tmp_path -- which is how the first draft of this change littered a working tree. They now patch both bindings. |
||
|
|
28b2b9f151 |
Pin the PostgreSQL session to UTC so defaulted timestamps are UTC (#2855)
On a UTC+3 install every AMS humidity reading and every archive was stamped three hours ahead of when it happened. Bambuddy stores naive timestamps that hold UTC and the frontend's parseUTCDate reads an offsetless timestamp as UTC, so the display added the offset to a value that was already local. The Python side has honoured that contract since #504. The reporter's timestamps were not written by Python. Around ninety-six columns take their value from server_default=func.now() and the migration DDL carries another forty-nine on DEFAULT CURRENT_TIMESTAMP -- the database fills those, and on PostgreSQL now() is a timestamptz, so storing it into a timestamp without time zone casts it through the session TimeZone. A Postgres container started with TZ=Europe/Istanbul bakes that zone into postgresql.conf at initdb, and every defaulted column then receives local wall-clock. recorded_at is the clearest case: nothing in the codebase ever assigns it, so its value is entirely whatever the database decided. Connections now carry timezone=UTC, which makes the cast a no-op whatever the server is set to. Measured through the real engine factory against a live PostgreSQL, a session on the reporter's configuration stored +10800s and the fixed one +0s. Pinning the session was preferred over a hundred and forty-five individual edits partly for its size but mostly because half of those sites are raw DDL that no model-level change can reach. SQLite needed nothing and gets nothing: its CURRENT_TIMESTAMP is UTC by definition and it has no session timezone to get wrong, which is why this survived two years of timezone fixes without showing itself. That also makes it the reference -- the change moves Postgres onto SQLite's behaviour rather than introducing a third convention -- so the SQLite behaviour is now pinned by a test instead of being assumed. asyncpg is the documented driver and takes the setting in its startup packet; any other Postgres driver gets the same setting the libpq way, so a psycopg URL does not fail at connect on a keyword asyncpg alone accepts. Rows already written are deliberately left alone. The inverse cast is computable and DST-correct, but it cannot be applied safely: created_at is assigned explicitly on some paths and defaulted on others, an install that began on SQLite holds correct and shifted rows side by side, and nothing distinguishes them after the fact. Timestamps are right from the upgrade forward and history keeps the times it was given. One related mismatch goes with it, because fixing the database side alone would have made it start lying on exactly the installs this repairs. The support package's oldest_pending_age_seconds subtracted a naive local clock from a naive UTC column, with a comment claiming it was UTC; on the reporter's install the two errors cancelled. It reported a job queued five minutes ago as three hours old east of Greenwich and a negative age west of it. The two AMS and printer-sensor retention cutoffs move to the same utcnow_naive helper -- correct in value already, but deprecated in 3.12 and emitting warnings on every sweep. |
||
|
|
c5e0055864 |
Track which nozzle each AMS feeds through the Filament Track Switch
With a switch fitted, an AMS is not wired to a nozzle any more. It is plumbed into one of the switch's two inlets and reaches both nozzles through it, so every unit reports its extruder as "not fixed" (0xE) and ams_extruder_map comes back empty. Bambuddy had nothing to fall back on but the AMS unit number, so AMS-A was badged R and AMS-B was badged L purely because their unit ids are 0 and 1, a third unit got no badge at all, and every one of those labels was wrong. The binding needed no new telemetry. BambuStudio reads it out of bits 24-27 of the same AMS info string we already parse for the type and the extruder id -- 0 is In-B, 1 is In-A -- and it only means anything when a switch is installed, because without one 0xE really does mean an uninitialised unit. That gates the read, which forced the switch block to be parsed before the AMS block: _handle_ams_data runs early in _process_message and _update_state only much later, so the binding was lost on every frame that carried both. The badge letters stay L and R, In-A reading as L, with the inlet named in full in the tooltip -- the letter is the inlet's position and not a claim about which nozzle that AMS feeds, since the switch can route either inlet to either outlet. Both views update live now. The switch fields were missing from the WebSocket payload, and the frontend shallow-merges each push over its cached status, so an absent field kept whatever the last full fetch left behind. The broadcast dedup key had no term for them either, so "Join IN-B" on the printer screen moved nothing: the binding is not in the tray component of that key, and not in the AMS change-hash, which covers tray fields only and must stay that way because it drives Spoolman sync. The rest of this is the calibration half, which is where it actually bites. K-profiles are calibrated per nozzle and the printer numbers its calibration table per nozzle too, so entry 16 exists on both hotends and means a different profile on each. A tray holds exactly one index. Move an AMS to the other inlet and every configured slot in it silently keeps pointing at the old hotend's table -- measured on the maintainer's H2C, a black PLA calibrated 0.018 left and 0.020 right stayed on the left profile after the move, and a manual RFID re-read only re-asserted the same wrong one. Bambu has not solved this either; their AMS dialog carries "TODO: fila_switcher broken the connection of ams->extruder" above the line that decides which nozzle's profiles to offer. Three copies of "which extruder is this slot on" each ended in else 0, which on a switch machine filed every profile under the right-hand nozzle. They now share one resolver that returns None for "unknown", because unknown and extruder 0 are very different answers on a dual-nozzle machine and conflating them is what bound a left-nozzle profile to a slot sitting on the right. The per-slot K value on the printer card had the same confusion from the other direction: its lookup was keyed on cali_idx alone, so one nozzle's K silently overwrote the other's. Moving an AMS now re-selects each configured slot's counterpart profile for the nozzle it has arrived on. Only the calibration binding moves, and only for slots whose spool already has a profile for that nozzle: configuring a slot is a deliberate preparation step, so a slot we know nothing about, or a spool calibrated on one hotend only, is left exactly as the operator set it. Nothing fires on the first sighting of a binding either, since every reconnect learns them afresh and re-applying there would overwrite a choice made by hand. Configure Slot resolves against the slot's own nozzle throughout. Option identity carries the extruder, so a filament calibrated on both hotends gives two distinguishable entries instead of two that collapse into whichever the printer listed first; options name the hotend; matches are scoped to the nozzle the slot feeds, with the other hotend's profiles still reachable under Other K profiles; and the slot's active index is resolved as a pair rather than followed into the wrong table. Inlet to nozzle is one table, In-A to the left hotend and In-B to the right, measured rather than assumed -- fila_switch.out cannot be used for it, reporting [1, 1] unchanged across a 90-second capture, both outlets claiming the same extruder. The print dialog picks up the same inlet labelling in its slot dropdown, replacing a left/right hint that never rendered because it matched snow-encoded values against global tray ids; decoding it correctly would not have saved it, since the firmware never reports which inlet is currently paired with which outlet. The dialog also notes when every filament a print needs sits behind one inlet, which is legal but slow -- a change between two filaments on the same inlet retracts the outgoing spool all the way back to its AMS, where a change across the two only retracts as far as the switch. Assigning an AMS to an inlet remains printer-side. BambuStudio can read that binding and has no command to write it, so there is no wire format to copy. |
||
|
|
7a42e0a7e5 |
Show which Filament Track Switch inlet each AMS feeds
With a switch fitted, an AMS is not wired to a nozzle any more. It is plumbed into one of the switch's two inlets and reaches both nozzles through it, so every unit reports its extruder as "not fixed" (0xE) and ams_extruder_map comes back empty on these machines. The printer card had nothing to fall back on but the AMS unit number, so AMS-A was badged R and AMS-B was badged L purely because their unit ids are 0 and 1, a third unit got no badge at all, and every one of those labels was wrong. The SpoolBuddy assign modal had the same fallback in a worse form, mapping anything that was not extruder 1 to R. The binding turned out to need no new telemetry. BambuStudio reads it out of bits 24-27 of the same AMS info string we already parse for the AMS type and the extruder id -- 0 is In-B, 1 is In-A -- and it is only meaningful when a switch is installed, because without one 0xE really does mean an uninitialised unit and those bits carry nothing. That gates the read, which in turn forced the switch block to be parsed before the AMS block: _handle_ams_data runs early in _process_message and _update_state only much later, so the binding was lost on every frame that carried both. _parse_fila_switch is split out and called first, and left in _update_state as well so that stays a complete absorb step. The badge keeps L and R rather than A and B, because the lettering is familiar and matches the physical layout. It is a different colour from the plain nozzle badge, and its tooltip names the inlet in full, since the letter is the inlet's position and not a claim about which nozzle that AMS feeds -- the switch can route either inlet to either outlet. An AMS still reporting a real extruder id keeps its ordinary badge, which BambuStudio also treats as authoritative over any switch binding, and a switch that has been fitted but not yet set up on the printer shows nothing rather than a guess. The print dialog's slot dropdown gets the same label. It replaces a left/right hint that never once rendered: ftsExtruderForSlot compared snow-encoded in[] values against global tray ids and could not match. Decoding it correctly would not have saved it -- the firmware reports which slot sits in each inlet and which nozzle each outlet feeds, but never which inlet is currently paired with which outlet, so no per-slot nozzle can be derived. That function is gone rather than fixed. The dialog also points out when every filament a print needs sits behind one inlet. Bambu's own guidance is that this is legal but slow: a change between two filaments on the same inlet retracts the outgoing spool all the way back to its AMS before the next can be fed up the shared tube, where a change across the two inlets only retracts as far as the switch. All on one inlet means every change in the job takes the slow path, and moving a single spool fixes it. So it advises, it does not block. Both views update live. Two things were stopping that. fila_switch and ams_switch_inlet were absent from printer_state_to_dict, and the frontend shallow-merges each WebSocket push over its cached status, so a field the push omits keeps whatever the last full fetch left behind. And the broadcast dedup key had no term for either, so "Join IN-B" on the printer screen moved nothing: the binding is not in the tray component of that key, and it is not in the AMS change-hash either, which covers tray fields only and must stay that way because it drives Spoolman sync. Assigning an AMS to an inlet remains printer-side. BambuStudio can read the binding and has no command to write it -- its switch class is parse and getters only, and the recommended-arrangement popup draws and publishes nothing -- so there is no wire format for us to copy. Adding the two fields to PrinterState broke four test modules whose SimpleNamespace stubs predate them. The stubs are fixed rather than the production reads made defensive: the real dataclass always carries both, and a getattr in the dedup key would silently stop tracking the field if it were ever renamed. |
||
|
|
9c93884397 |
Stop auto K-profile calibration leaving an archive behind
With flow dynamics calibration on, the printer lays down a pressure-advance line before the print itself and announces it over MQTT through the same print-start event a real print uses. Bambuddy archived it: a row named auto_pa_line_calib_mode marked as having no 3MF, sitting in among the user's actual prints, with a Print Started and a Print Completed notification for each one. The printer's other internal jobs were already skipped, but only by the /usr/ path they carry -- bed levelling reports as /usr/etc/print/auto_cali_for_user.gcode. The pressure-advance line carries no path at all. It arrives as a bare subtask name, so a rule that only ever looked at the filename could not see it. Falling past the guard it reached the no-3MF fallback, where print_name is subtask_name or filename, and named the row after the calibration. Internal jobs are now recognised by name as well as by path, from either field, in one place both callbacks share. The match is exact after normalising away the directory, one print-file suffix and case, rather than a prefix or substring rule: "auto" and "calib" are ordinary words in a user's own filenames, and a rule loose enough to catch some unnamed future calibration would quietly swallow somebody's print. The completion is suppressed too, and that half matters more than the noise. With no archive to close, the completion falls into the no-archive notification path -- which attributes an unmatched completion to any queue item the printer finished in the last five minutes and emails its owner. This calibration runs alongside a real print, so silencing only the start would have told that print's owner their job was done, early, and again for real later. The guard sits inside the no-archive branch, so the plate-clear gate, the queue reconciliation and the SD-card cleanup all still run; only the notification is skipped. Skipping the run early also drops the FTP sweep that preceded the fallback -- six candidate names across five directories with retries, around a hundred connections looking for a file that cannot exist, aimed at a printer that is in the middle of calibrating. auto_cali_for_user no longer sends a Print Started notification either. It is the same event about the same kind of job, and the archive was never the only thing wrong with treating it as a user's print. |
||
|
|
7a9b4921bd |
Stop the AMS temperature alert firing for heat the user asked for (#1802)
The alert compares against ams_temp_fair, the same threshold that colours the printer card, which defaults to 35C. Drying deliberately runs at 45C for PLA, 65C for PETG and up to 85C on an AMS-HT, and the alert repeats once an hour for as long as the condition holds, so a twelve-hour dry sent twelve notifications about a temperature the user chose. It then kept sending them while the unit cooled back down, which is the half the reporter confirmed on an AMS 2 Pro and an H2C. Dispatch now consults the drying state the firmware already reports. dry_time alone is not enough: it reads 0 through the cooling phase that closes a cycle, so dry_status -- info bits 4-7, already parsed for the drying-complete edge -- carries the rest. That constant moves out of bambu_mqtt into a leaf util rather than being duplicated; drying_preflight would have been the natural home, but it imports printer_manager, which imports bambu_mqtt, and bambu_mqtt is one of the callers. The cool-down afterwards is held by a latch released as soon as the unit reads back at or below the threshold, rather than after a fixed delay, so a 65C cycle in a cold basement and a 45C one in a warm room each get the time they actually need. A two-hour cap bounds the one case the latch cannot resolve on its own -- a unit that never returns below the threshold -- and since such a unit would have been alarming with no drying involved, releasing there restores the ordinary behaviour instead of inventing a new alert. Two exclusions are deliberate. Humidity is untouched, because during drying that reading falling is the whole point. And dry_status 6, HeatOutOfControl, is kept out of the active set: an AMS that has lost thermal control is exactly when the alert should still arrive, so it must never read as expected heat. A cycle plus its cool-down outlasts a restart, so the latch is a settings row rather than a dict beside _ams_alarm_cooldown -- the internal timestamp-row pattern support.py already uses. It is read once per pass and written back only when a unit changed it. Stamps ahead of now are clamped on read, since a box whose clock jumps backwards writes them and suppression is measured as now minus the stamp; without the clamp the cap would measure from a moment that has not happened yet and hold the alert quiet for the skew on top of it. No new setting. The reporter was offered the opt-out checkbox they asked for and said they would not want it if the alert simply never fired during drying. |
||
|
|
907de4d64d |
Suppress two Bandit false positives in the new FTP and batch-order tests
The 1.2.5.3 code-scanning run flagged two new alerts, both in test files added this release, and both false positives. B402, the ftplib import in the #2780 connect-cleanup tests, is the HIGH finding that failed the check. The test imports ftplib to construct the exceptions BambuFTPClient.connect has to survive -- error_perm and error_temp, at lines 50, 51 and 75. Nothing in the file opens a connection, and bambu_ftp.py already carries the same marker on its own import. B108, the /tmp path in the batch-order archive fixture, is the MEDIUM one. The value is a string written into PrintArchive.file_path so the row has a path; nothing ever opens it. Every other archive fixture in the suite carries the same marker on the same idiom. Both markers follow the wording already in test_bambu_ftp.py and test_sjf_scheduling.py. Bandit's medium+ count over backend/ drops from 17 to 15, and neither file contributes to what is left. |
||
|
|
0e591b2199 |
Suppress two Bandit false positives in the new FTP and batch-order tests
The 1.2.5.3 code-scanning run flagged two new alerts, both in test files added this release, and both false positives. B402, the ftplib import in the #2780 connect-cleanup tests, is the HIGH finding that failed the check. The test imports ftplib to construct the exceptions BambuFTPClient.connect has to survive -- error_perm and error_temp, at lines 50, 51 and 75. Nothing in the file opens a connection, and bambu_ftp.py already carries the same marker on its own import. B108, the /tmp path in the batch-order archive fixture, is the MEDIUM one. The value is a string written into PrintArchive.file_path so the row has a path; nothing ever opens it. Every other archive fixture in the suite carries the same marker on the same idiom. Both markers follow the wording already in test_bambu_ftp.py and test_sjf_scheduling.py. Bandit's medium+ count over backend/ drops from 17 to 15, and neither file contributes to what is left. |
||
|
|
95e28e39ce | Bumped version | ||
|
|
e899022116 |
fix(profiles): read the companion files that hold a preset's real gcode
A bundled preset can keep a setting in `<preset> template <key>.json`, a
file the preset itself does not reference -- the desktop slicer finds it
by name. Walking only `inherits` never reached it, so every one of the 56
instantiable BBL machine presets resolved `machine_start_gcode` to the
577-character generic block on fdm_machine_common instead of its own
6.5-21 KB one. That block holds the M620 AMS load and the M1002
gcode_claim_action calls, so a print sliced from it heats the bed, moves
the toolhead and extrudes nothing (bambuddy#2838).
Companions are now folded into each ancestor as the chain is walked, at
that ancestor's precedence, so a caller's own value still wins and the
0.2/0.6/0.8 variants reach their 0.4 sibling's companion. They are found
by listing rather than by a fixed set of keys.
Covered against the shipped bundle, not fixtures: a new e2e spec resolves
all 56 presets inside the image and fails on any that still lands on the
generic block.
|
||
|
|
2d324dc7d0 |
Let API keys read and run slicer pipelines (#1425 follow-up)
Every pipeline endpoint answered 403 for API keys whatever scopes the key
carried. PR A parked all three permissions on the admin denylist until the
run dispatch existed to decide about; it landed in PR C and the parking was
never revisited.
PIPELINES_READ now rides can_read_status. PIPELINES_RUN requires
can_queue AND can_manage_library together, so the allowlist gained tuple
values: a run slices into the library and then queues prints, and mapping
it to either flag alone would hand that flag the other one's authority.
The 403 names every flag the key is short of. PIPELINES_WRITE stays
admin-only -- a key can run the recipe, not rewrite it or clear the log.
Opening the run route also needed the cloud-owner fallback the direct
slice route makes: a pipeline can carry Bambu/Orca Cloud presets, and
resolving those reads a token off a user record that an API-keyed request
does not have. retry_failed forwards the new dependency explicitly,
since a direct call receives the Depends marker rather than None.
|
||
|
|
aa4df0c57a |
Build the slice output's path from a name a folder can have (#2832)
A print's display name comes from inside the 3MF, not from the filename,
so a MakerWorld title arrives with its punctuation: "Planter Pot with
Drip Tray, 12 cm / 5 inches". The slice-to-archive sink used it verbatim
for the output folder and the output file, and a slash in a folder name
is not a character -- it is another folder. mkdir(parents=True) created
the level it implied and the file's own join added a third that nobody
had made, so the slice failed with ENOENT on a path that half existed.
Renaming the print first was the only way through.
Reduce a display name to a single path component before it becomes one.
Characters a name cannot hold are replaced rather than dropped, so the
folder still reads like the model's title, and the set is the one the SD
card already rejects -- which covers a Windows install too, where the
colon in "Model: v2" fails the same way. The name shown in Bambuddy is
untouched: a title is allowed its punctuation, and refusing the slash
would reject the name this was reported about.
The joins are asserted to stay under the archive directory. That was
already claimed by a SEC-PATH-OK marker on both lines, citing a
sanitiser that is defined in another module and was never called here;
without the marker the path-join backstop flags them both. The claim is
now true, and a future edit that reaches around the reduction is caught
rather than trusted.
The library sink takes the same embedded name, so it gets the same
reduction: managed storage names the file after a UUID and never saw
this, but an external folder writes the name as given.
Display names are also stripped of control characters on the way into
the database, in the schema and in the archive service. The validator
hands back anything that is not a string rather than iterating it, so
the field still answers a list or a bare int with a 422 instead of
accepting the one and failing on the other.
Display names are also stripped of control characters on the way into
the database, in the schema and in the archive service, cleaned before
the filename fallback rather than after it so a whitespace-only embedded
name still falls through to the filename. The validator hands back
anything that is not a string rather than iterating it, so the field
still answers a list or a bare int with a 422 instead of accepting the
one and failing on the other.
|
||
|
|
dde724f83c |
Repair no-3MF archives' photos and their silent filament writes (#1820)
Two faults behind the same kind of print: one that arrives without a
retrievable 3MF, which on an H2S is any job started from the printer's
own internal library.
Such an archive has no file_path, and Path("").parent is Path("."), so
every site that derived the archive's folder from it landed on the data
directory itself. The finish-photo capture spotted that and wrote to
<archive_dir>/<id>/photos instead. Nothing else did. The photo was
written in one place and looked for in another: reads 404'd, deletes
dropped the name and left the file, and the notification attachment
never found the image. Hand-uploaded photos worked only because upload
and read agreed with each other rather than with the capture. Give the
question one owner in utils/archive_paths and have all four sites ask
it. Lookups check the old shared location too, so photos already
uploaded there stay reachable; uploads now go where captures go.
Separately, the remain%-delta fallback that stands in for a missing 3MF
can charge nothing for several reasons, and did so without a word. The
AMS reading is coarse and, on the reporter's printer, noisy: it rises
mid-print, swings five points over a job, sits at 100% through a
36-minute print on a fresh spool, and goes negative on a nearly empty
one -- which the start-of-print gate rejects, dropping the only slot
that was printing. Two of their prints went uncounted for two different
reasons and both read as "no spools updated", which is also what a print
with nothing to charge prints. Name the slot and the two readings in
each case, on the Spoolman path and on the internal-inventory path,
which has carried the same gates since #1119.
The Spoolman path also had no notion of which slots the print used, so a
spool swapped into an idle slot mid-print reads as consumption and is
billed to whoever that slot is assigned to -- the fault #1269 fixed for
the internal tracker, still open here, and likeliest on exactly the
prints this fallback serves, where nothing else narrows the field. Use
the same three pieces of evidence it does: the print's mapping, its
mid-print tray changes, and the tray it started on. The last needs
storing, because the internal tracker's row is deleted before this runs
and a screen-started print has no mapping to fall back on -- hence a new
nullable column, and no backfill, since a row from before it existed has
nothing to say. Where no evidence exists at all, every slot is still
considered.
Both paths also treated tray_now == 255 as naming a slot. It does not:
it is the field's initial value, the fallback for an unparseable
reading, and what it reports with nothing loaded. Mapped as a tray id it
becomes (255, 1), so as the only evidence it excluded every real slot
and charged nothing at all -- this issue's own bug, arriving by a new
route. On the internal path that is live today; on the Spoolman path it
would have shipped with the guard above. The external holder reports 254
when it is genuinely in use.
The arithmetic is untouched: at one percent per step this cannot resolve
a small print, and pretending otherwise would be worse than saying so.
|
||
|
|
15eace71d6 |
Show the plug that powers the printer in the card's Power row (#2830)
A printer card has one Power row: a plug name, its draw, and the auto-off
and on/off buttons. Which plug filled it was decided by nothing -- the
endpoint returned the first row the database handed back that was not a
Home Assistant script, from a query with no ORDER BY.
For the reporter that was an enclosure exhaust fan, added before the
outlet their X1C is plugged into. The card showed the fan's name with
'--' for watts, offered to switch the printer off by cutting the fan,
and demoted the metered outlet to the small HA button row. The fan was
marked as not powering the printer and hidden from the card; neither
setting was consulted here, though controls_printer_power has decided
the scheduler's power-on pick since #2629.
Rank the candidates instead: switchable at all, controls_printer_power,
enabled, show_on_printer_card, reports power, lowest id. The first rules
out a script, which can only be run, and an MQTT plug, which the control
endpoint rejects as monitor-only -- and an MQTT plug is exactly the kind
that reports watts, so without it ahead of the power tiebreak the row
could land on a plug whose on/off button answers with an error. The last
is not cosmetic: with no ORDER BY, a plain UPDATE on PostgreSQL can move
a row and silently swap which plug the card calls the printer's power.
None of these excludes a plug. A printer whose only plug is hidden,
disabled or monitor-only still needs its Power row, because that row
holds the on/off button and the HA buttons are drawn inside it.
controls_printer_power sits above show_on_printer_card because the two
only disagree when the plug that really feeds the printer is hidden, and
letting a display preference win there points the power buttons at an
accessory -- the fault #2629 fixed. Power capability is read from the
configuration, not measured: this runs on every card render, and it is
approximate both ways, so it only breaks a tie.
The scripts endpoint shares the same pick and excludes it, so a
switchable main plug is not repeated as a button directly below itself.
A script is left in place: a printer whose only entities are scripts
falls back to showing one in the power row, and taking it out of the
button row too would cost it the one-click run it has always had.
|
||
|
|
46aa6affd3 |
Match a print completion to its queue job the way the printer names it (#2829)
Bambuddy has no run identifier to tie a completion to a queue row, so it
finds the row by printer and status='printing' alone.
|
||
|
|
b83eea07cd |
Explain a print that never reached the printer's card, instead of sweeping for it (#2780)
Bambuddy reads a print's 3MF, cover and timelapse over FTPS on port 990,
which on every Bambu model serves external storage only. Under some
configurations H2-series and P2S firmware keeps the sliced file on
internal storage, where Bambu Studio put it over the port-6000 service,
and then no path on 990 can find it.
The print command has always said which of the two it used -- `url` reads
ftp://<name> or brtc://emmc/<name>. We discarded it and swept anyway:
~110 connections per print, all certain to fail, ending in an archive
card with nothing on it and no stated reason. In the reporter's bundle
all 35 dispatches to their H2C and P2S said internal storage, all 25 to
their X1C said external, and all 44 empty cards belonged to the first two.
Read the field, skip the sweep when it cannot succeed, and record which
reason applied. A printer that uses the card is unaffected, and so is one
we have no answer for -- silence is not evidence, and reading it as bad
news would break archives that work today.
The answer is held per print and dropped when that print ends, rather
than kept as a standing fact about the printer. Plenty of prints never
announce themselves: 14 of the 79 print starts in that bundle arrived
with nothing on the request topic, started from the printer's own screen
or picked up after a restart. Left standing, one slicer print to internal
storage would suppress the lookup for every screen-started print after
it, on a printer whose files really are on the card. The sticky reading
is kept for the connection diagnostic alone, which is run after the print
that prompted it and would otherwise have nothing to report.
Two things that pointed the wrong way go with it. The archives banner
told everyone to enable "Store sent files on external storage"; the
reporter had it on for the whole three weeks and it would not have
helped. The diagnostic passed a printer whose slot was empty, because it
read only the toggle -- an empty slot is now a failure naming the slot,
and a printer that has storage and still used its own is a warning. On
P1-series that empty-slot failure yields to the existing unsupported-model
skip: the toggle cannot be switched on there at all, so telling the
operator to insert a card would promise a fix inserting a card does not
deliver (#2524).
Also close FTP sockets on the failure paths, which dropped them for the
garbage collector -- 1813 in a day in that bundle -- and drop the advice
to restart the printer, which the reporter tried twice while a single
manual connection to the same printer handshook cleanly.
This does not make the affected prints archive in full; that needs the
port-6000 protocol tracked in #2762.
|
||
|
|
8e553289db |
Choose which rack nozzle each filament prints from on an H2C (#1784)
The Vortek rack holds six hotends, and a multi-colour plate is sliced to
use a different one per colour so it can skip the purge. Which of the six
each colour takes is not in the 3MF. The same plate, sliced and sent twice
from Bambu Studio with a different choice each time, produces two files
that differ only in rounding in the last digit of a few extrusion figures
-- the filament grouping, the toolchange stream, the 120 nozzle-change
markers and project_settings.config are all identical. The choice travels
only in the dispatched nozzle_mapping.
Bambuddy had no way to state it, so those plates went out with no nozzle
assignment at all and the printer chose for itself. That is what levelled
on one hotend and printed with another, millimetres above the plate.
Every rack-bound filament now carries a position picker beside its AMS
slot dropdown, listing all six with the nozzle each holds. An empty
position, or one holding the wrong diameter or flow type, is shown greyed
out with the reason rather than hidden, so someone looking for position 4
finds it. The choice is per filament *group* rather than per slot, because
a group is one hotend: two filaments the slicer grouped together share it
and cannot point at different positions.
Nothing has to be picked. Positions are assigned automatically, preferring
one already loaded with that colour, which on the plate this was built
against reproduces Bambu Studio's own pick exactly.
A nozzle currently picked up onto the carriage is offered too. The
firmware drops its rack position from the report entirely rather than
sending a placeholder (#943), and refusing it would rule out the position
most likely to be wanted -- the one the last print left mounted. Only
recoverable when exactly one position is missing; two gaps are genuinely
ambiguous and stay unavailable.
Positions are re-checked at dispatch, not just when queued, because the
rack can be re-loaded in between. The two failure modes differ on purpose:
an explicitly chosen position that no longer fits stops the print, names
what the position now holds, and deletes the uploaded file from the SD
card so it cannot be started by hand either -- an operator who named a
hotend must not silently get a different one. An automatic assignment that
cannot be made instead falls back to letting the firmware choose, which is
what happened before any of this existed.
The pick is stored as {group: position} rather than as the expanded
nozzle_mapping, though that is what goes on the wire. That column means
"Bambu Studio decided, forward verbatim", and only the group-and-position
form can be re-checked against what is actually mounted at dispatch.
The existing multi-rack refusal in extract_nozzle_mapping_from_3mf stays.
It still guards the #2800 fallback, which can only ever name one rack id.
Measured on the maintainer's H2C: rack position n is physical nozzle id
15 + n, confirmed by cross-referencing two captured dispatches against
Bambu Studio's own dialog. extruder_max_nozzle_count names which carriage
is the rack straight from the file, and is read rather than assumed -- a
fourth independent confirmation of the carriage indices fixed in
|