Let one checkbox say where a slice's settings come from (issue #2942)
Two features in the slice dialog read as one. "Use the file's built-in
settings" slices a 3MF the way its designer set it up, ignoring the picked
profiles. The per-option "from file" ticks beside each setting carry the
designer's individual deviations onto the profile you picked, and those
arrived pre-ticked whatever the checkbox said. So a slice run deliberately
without the file's settings still took sixteen values out of it -- the
reporter's log names them, enable_support and support_type among them,
landing on a process preset they had chosen on purpose.
The ticks now follow the checkbox. Off, nothing comes out of the file until
it is asked for by name; on, every setting the file changed shows ticked,
because on that path the file really does drive the whole slice. Taking the
designer's work in bulk is still one click, from a line at the top of the
panel that says how many settings the file changed -- it is the only way
left to reach them without hunting for chips across six pages of 348
options -- and it still leaves the machine-tuned keys and the two that are
the picked preset for a per-key decision.
The panel greys out options the slicer's own rules switch off, and it was
evaluating those rules against what the user had typed alone, falling back
to the compiled-in schema defaults for the rest. A preset with supports on
therefore read as enable_support: false and greyed out the whole Support
page while the slice ran supports. A greyed row greyed its tick too, which
is how the reporter's screenshot shows a support type marked "from file",
applied to the slice, and impossible to clear. The rules now see what the
slice will actually run with: the preset's values, the file's values for
the keys that are on, and anything typed on top. The tick is no longer
gated on those rules at all -- it answers a different question, not whether
an option is in play but where its value comes from.
Underneath both, the support carry-over ran outside the ticks entirely,
lifting four keys out of any 3MF that had supports on with nothing on
screen able to decline. It now stands down for the keys that were offered
and turned down, which the request can say for the first time: an empty
design_overrides list means the caller was shown the file's settings and
took none, where no list at all is a caller that predates the choice. That
distinction is what keeps the carry whole for sources with no deviations to
tick, an OrcaSlicer export among them, rather than trading one silent
default for another.
Worth knowing: a Bambu Studio file with supports enabled no longer switches
supports on for you. Tick Enable support, or the checkbox above the panel.
Measured against the reporter's own sixteen keys, and covered by backend
and frontend tests -- reverting any one of the three changes fails tests.
|
||
|
|
818543c4f6 |
Say which blue a colour mismatch is about (issue #2941)
A print was refused a colour match between two filaments the dialog itself
labelled "Blue". The comparison was right: the slicer profile asked for a
near-pure #0028FF and the slot held Bambu's navy #0A2989, 118 apart in the
blue channel alone and a CIEDE2000 distance of 15, where 1 is a
just-noticeable difference. Nothing on screen said so. A hex that misses the
colour catalogue is named by a coarse family bucket, so both sides resolved
to the same word, and the warning sat between two identical labels with
nothing to reconcile it against. Read as a broken matcher, which is what the
report said, and a fair reading of what was shown.
Where both sides of a mismatch carry the same name they are now qualified by
their hex, and the tooltip names them together: "Same type, different color:
needs Blue (#0028FF), slot has Blue (#0A2989)". Names that already differ are
left alone -- the hex is noise once the words separate them -- and a side with
no name falls back to its hex rather than growing an empty bracket.
The comparison is untouched. It was correct, and its tolerance is not
something to widen on one report: a difference that size would start matching
navy to cyan, and eligibility is the same rule the queue scheduler dispatches
on, so loosening it would change which spool gets printed rather than only
which warning gets shown. This issue was about being able to see why the
warning fired, and a test pins that it still fires.
The strings around it were hardcoded English: the panel's status line, the
required-filament tooltip, the auto-matched marker, the slot placeholder, the
mismatch detail and the type-not-found message. All nine now go through
translation, in all thirteen locales. Two of them -- "Same type, different
color" and "Filament type not loaded" -- turned out to have had translations
sitting in every locale file the whole time, unused, while the component
rendered the English literal beside them. The parity gate could not have
caught any of this: keys that were never added have nothing to compare
against.
|
||
|
|
b212ba984a |
Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status
response never carried it, so every consumer that wanted to tell a user
why a print halted resolved the same 853 codes from its own duplicate of
the same sentences -- this repo's Python table, the frontend modal's, and
at least one third-party client whose catalogue exists purely because the
server would not say. Each ages separately, and a relay watching a
printer could only manage "your printer needs attention" while the server
already knew it was "Filament ran out. Please load new filament."
hms_errors[] entries now carry a description, defaulting to null so a
client that has never seen the field is unaffected.
It is resolved where the fault is parsed rather than at the boundary that
prompted the request, because there are three serializers of a fault, not
one: the status response, the WebSocket broadcast, and the completion
payload the queue's failure reason is built from. Adding it to only the
first would have handed half the feature to a relay watching the stream,
which is the likelier consumer of the three. The queue's failure reason
now quotes the resolved sentence instead of looking the code up a fourth
time, and the notification path reads it rather than re-deriving. That
they cannot report different text for one fault is the point, and a test
asserts they agree.
describe_fault is the single mapping from either code shape onto the
table. An 8-char print_error is the catalogue's MMMM_EEEE key with the
separator removed -- the parser derives full_code and that key from the
same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier
is tried whole and then collapsed to its first and last groups.
That collapse is lossy, and keeping it was the decision worth making
carefully. #2728 counts 65 documented faults falling onto 0300_0001
alone, so a hit can attribute a neighbour's sentence to this fault, and
refusing it looks like the stricter reading. It is not: the notification
path, the queue's failure-reason helper and the frontend modal have all
resolved hms[] faults this way for as long as they have existed, and it
resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape.
Declining to collapse would have stopped describing faults that are
described today, silently suppressed the notifications they raise, and
left this field null while the UI showed text for the same fault.
Narrowing it belongs with #2728, where both key spaces can move together.
So the lookup is exactly what it was, verified rather than asserted:
a test walks every catalogue code in both fault shapes across all three
alert levels and checks the result against the derivation this replaces.
A future change to the lookup cannot quietly stop notifications firing.
The catalogue ships one language, so the field is English and
unlocalized, which the schema and the API reference both say next to it.
The camwall feed is deliberately left alone -- it is code-only because
its token travels in a URL on a screen, and a readable sentence discloses
more than the camera picture already does. The frontend keeps resolving
its own text: switching it would change what filterKnownHMSErrors counts
across eight call sites, which is #1840 and #2728's argument to have.
HMSError.message goes with this -- a text field that was never set or
read anywhere, and an invitation to populate the wrong one now that a
live description sits beside it.
-----
Record a failure code the user can actually look up
The queue's failure reason formats a fault's module and error into
MMMM_EEEE, and that one derivation never masked the error to 16 bits. A
fault arriving from the printer's hms[] array carries its alert level in
the code's high half, so the label came out as 0500_24038 -- five digits
in a group that has four. It is not a code anyone can find on Bambu's HMS
index, and because it matches no catalogue key the sentence explaining
the failure was dropped along with it, leaving the bare number alone.
The nozzle-size mismatch behind #1111 is exactly such a fault. Reported
one way it read "[0500_4038] The nozzle diameter in sliced file is not
consistent with the current nozzle setting"; reported the other, the same
physical fault read "[0500_24038]" and nothing else.
There is already a helper that gets this right, used by the archive's own
failure-reason lookup, so this calls it instead of keeping a fourth copy
of the derivation. It also takes the raw integer code the MQTT payload
carries, which the local version only handled as a string.
|
||
|
|
3da0c18c4d |
Let a virtual printer be told which address to advertise
BambuStudio reads its FTP upload destination out of net.info[].ip in the
MQTT status, and the bridge fills that field from the VP's bind address.
On Docker bridge networking the two are different machines' worth of
address: slicers reach Bambuddy on the host's LAN IP, the container binds
something like 172.24.0.2, and that private address is what the slicer was
handed -- so it opened an FTP connection to an address that does not exist
on its network and the send stalled around 10%.
VIRTUAL_PRINTER_ADVERTISE_ADDRESS supplies the address slicers actually
use, taking precedence over the bind address and over the same-subnet host
interface the bridge falls back to. The armed log line names its source, so
(VIRTUAL_PRINTER_ADVERTISE_ADDRESS) against (bind_address) tells an
operator whether the variable reached the container at all, and the
not-armed diagnostic now names it as the remedy -- a bridge-network install
that has not set it is exactly the one that cannot auto-resolve either, and
until now saw only that nothing worked.
An environment variable rather than a change to how the advertised address
is resolved, which is the decision worth recording. The VP already has a
"Network Interface Override" field, and reading it here is the smaller
patch, but it feeds SSDP and the certificate SANs only: honouring it would
silently move the upload destination on every install that has one set --
the multi-NIC, VLAN and Tailscale setups, which are the ones most likely to
have been arrived at by hand and least likely to survive being
second-guessed. Unset, this changes nothing, and a test pins that.
A value that is not a dotted-quad IPv4 is refused with one warning naming
it and the previous address is used instead. That direction is deliberate:
declining to rewrite would put the real printer's IP back in front of the
slicer, which is the leak the rewrite exists to close, so a typo must not
be able to reopen it. 0.0.0.0 counts as unset and whitespace is stripped,
for values pasted into a compose file.
Host and macvlan networking need none of this and stay what Virtual Printer
is developed against. The variable removes one blocker; it does not make
bridge mode equivalent. The wiki said in three places that the host address
could not be discovered at all, which is no longer true, so those now
describe the variable and keep the recommendation.
|
||
|
|
5de06cca0f |
Stop offering AMS slots as places to store a spool
The Storage Location dropdown listed entries like "H2D-1 - AMS A1" next to
real locations, and they could not be got rid of.
They were never locations. Bambuddy used to record which slot a spool was
loaded into by writing that string into Spoolman's location field, and the
writer went away when Storage Location became something the user picks --
but the strings stayed on people's Spoolman spools, and the location sync
imports every distinct one it finds, so they have been coming back in
through the front door ever since. A printer slot is where a spool is
loaded, not where it is put away, and slot assignments already track the
first.
Deleting one by hand did not work either, which is what made this a dead
end rather than an annoyance: the delete route refuses a location that has
spools, and in Spoolman mode it counts them by matching that same string,
so every marker still sitting on a loaded spool answered 409 -- and the two
that were empty were back on the next sync a minute later.
The import now skips them and a one-shot migration clears the ones already
in the catalogue. The shape is defined once and used by both: an optional
printer-name prefix followed by AMS A1, AMS-HT A1 or External Spool, which
is exactly what convert_ams_slot_to_location produced. It stays narrow on
purpose -- "AMS Drybox" and "Spare AMS trays" are somebody's shelf, and
anything the filter swallowed would be a place they could no longer file a
spool under -- so both directions are pinned by tests.
A row is only removed when no spool in this database points at it, by id or
by legacy free-text name, so an internal-mode user who has deliberately
filed spools under such a name keeps it. Spools in Spoolman are neither
consulted nor touched: their location strings are the user's data on the
user's server, and one that still reads "H2D-1 - AMS A1" in the inventory
list is telling the truth about what Spoolman holds. It simply stops being
offered as a destination.
Verified on a live Postgres instance carrying the reported symptom: 13
locations down to 3, all ten markers removed, the two real shelves and one
hand-typed Spoolman name left alone.
|
||
|
|
8c01e0f8ea |
Draw a spool the way the AMS described it, and correct the tare it was added with
Two faults in the same auto-add path, both found while tracing why an H2C
slot named a wood roll as plain PLA.
A spool's swatch is composed from effect_type and extra_colors, and the
RFID auto-add set neither. It reads the colour catalogue to name the
colour and took the name alone, even though the row it had in hand also
carries those two columns -- the spool form's own colour picker hands both
to a spool a user adds by hand, so the same roll rendered one way when you
typed it in and another when the printer identified it for you.
Both columns now travel with the name. That alone changes nothing on a
stock install, because the shipped catalogue carries an effect on none of
its 600-odd rows, so the subtype is read where the catalogue has none: it
is already derived from what the printer reports, and the two vocabularies
line up -- Wood, Silk, Sparkle, Marble, Glow, Galaxy, Metal, Rainbow,
Translucent, Matte, and the Gradient, Dual Color and Tri Color that the
M*/T* colour codes upgrade a subtype to. "Silk+" reads as Silk, since the
plus is on the product name rather than the finish. A subtype that names
no effect -- Basic, Tough, CF -- leaves the column empty rather than
inventing an overlay, and a value already set is never overwritten, so the
column stays what it is documented to be: a rendering hint the user can
override without touching Bambu's categorical label.
------
Correct the spool tare an RFID roll was added with (#2909)
The lookup that gave an auto-added spool its core_weight asked for the
first catalogue row whose name starts "Bambu Lab" and took whatever came
back. There are three, and which is first is the database's business:
SQLite returns insertion order in practice, Postgres promises nothing once
a table has seen an update. The same roll was therefore recorded with the
216 g High Temp tare on one install and correctly with the 250 g Low Temp
one on another. @ojimpo's forward fix picks the row by name; this repairs
the rows already written, which the forward fix cannot reach -- 22 of 26
RFID-added spools on the instance this was traced on.
The tare is not cosmetic. A spool weighed on SpoolBuddy has its remaining
filament worked out as the scale reading minus the tare, so a 34 g low
tare credits the roll with 34 g that is not there and writes a used weight
34 g short. That error is a constant -- every later print adds to the used
weight on top of it -- so adding the difference back is exact however much
has been printed since. It is applied only to spools that have been on the
scale; one that never was has a used weight derived from the AMS remaining
percentage, which the tare never entered into.
Rows are identified by the signature of the broken lookup: added by RFID,
carrying the weight of one of the other Bambu catalogue rows, with the
weights read out of the catalogue rather than hardcoded so an install
whose rows have been re-measured is repaired to its own numbers. Keying on
whether a catalogue row had been recorded would not have worked -- the
weight picker auto-selects the only row matching the weight and writes its
id on the next save, so that column says only whether the form was ever
opened. The one case that cannot be told apart is stated rather than
hidden: someone who moved an RFID roll onto a genuine High Temp spool and
set 216 g by hand is normalised with the rest. Runs exactly once, so a
tare set afterwards is kept.
|
||
|
|
09d8ca351d |
Name a spool by its subtype on the slot it is assigned to
A spool's subtype is half of what it is called: "PLA" and "PLA Wood" are
different filaments. The AMS slot's hover card built the assigned-spool
line out of brand, material and colour name and left the subtype out, so
a roll of Bambu PLA Wood Classic Birch in an H2C's A4 was announced as
"Bambu Lab PLA - Classic Birch".
Everything else named it correctly at the same moment -- the RFID read,
the inventory row, the slot's own profile line, which is built from the
spool's slicer preset rather than reassembled, and Bambu Studio -- so the
one wrong line read like a bad tag read rather than a display fault.
It was not only the render. The card's assignedSpool prop had no subtype
field at all, and the six places the printer card fills it in -- regular
AMS, AMS-HT and external spool, each in both Spoolman and internal-
inventory mode -- never passed one, so the value could not reach the
component. The field is required rather than optional, which is what
stops the next call site from quietly omitting it; that omission is the
whole of this bug.
Three more surfaces rebuilt the name the same way and are fixed with it:
the SpoolBuddy AMS slot panel in both inventory modes, and the write-tag
confirmation. Every other place a spool is named -- the assign dialogs,
the inventory cards, the forecast rows, the label picker -- already
included the subtype, so these four were the outliers.
This is the display-side half of #2902, which stopped the backend
reducing a filled or foamed filament onto its base material. The card was
doing the same thing to the same spools, one layer further out.
|
||
|
|
b1f5ec9642 |
Let one checkbox say where a slice's settings come from (issue #2942)
Two features in the slice dialog read as one. "Use the file's built-in settings" slices a 3MF the way its designer set it up, ignoring the picked profiles. The per-option "from file" ticks beside each setting carry the designer's individual deviations onto the profile you picked, and those arrived pre-ticked whatever the checkbox said. So a slice run deliberately without the file's settings still took sixteen values out of it -- the reporter's log names them, enable_support and support_type among them, landing on a process preset they had chosen on purpose. The ticks now follow the checkbox. Off, nothing comes out of the file until it is asked for by name; on, every setting the file changed shows ticked, because on that path the file really does drive the whole slice. Taking the designer's work in bulk is still one click, from a line at the top of the panel that says how many settings the file changed -- it is the only way left to reach them without hunting for chips across six pages of 348 options -- and it still leaves the machine-tuned keys and the two that are the picked preset for a per-key decision. The panel greys out options the slicer's own rules switch off, and it was evaluating those rules against what the user had typed alone, falling back to the compiled-in schema defaults for the rest. A preset with supports on therefore read as enable_support: false and greyed out the whole Support page while the slice ran supports. A greyed row greyed its tick too, which is how the reporter's screenshot shows a support type marked "from file", applied to the slice, and impossible to clear. The rules now see what the slice will actually run with: the preset's values, the file's values for the keys that are on, and anything typed on top. The tick is no longer gated on those rules at all -- it answers a different question, not whether an option is in play but where its value comes from. Underneath both, the support carry-over ran outside the ticks entirely, lifting four keys out of any 3MF that had supports on with nothing on screen able to decline. It now stands down for the keys that were offered and turned down, which the request can say for the first time: an empty design_overrides list means the caller was shown the file's settings and took none, where no list at all is a caller that predates the choice. That distinction is what keeps the carry whole for sources with no deviations to tick, an OrcaSlicer export among them, rather than trading one silent default for another. Worth knowing: a Bambu Studio file with supports enabled no longer switches supports on for you. Tick Enable support, or the checkbox above the panel. Measured against the reporter's own sixteen keys, and covered by backend and frontend tests -- reverting any one of the three changes fails tests. |
||
|
|
cbbdab86f9 |
Say which blue a colour mismatch is about (issue #2941)
A print was refused a colour match between two filaments the dialog itself labelled "Blue". The comparison was right: the slicer profile asked for a near-pure #0028FF and the slot held Bambu's navy #0A2989, 118 apart in the blue channel alone and a CIEDE2000 distance of 15, where 1 is a just-noticeable difference. Nothing on screen said so. A hex that misses the colour catalogue is named by a coarse family bucket, so both sides resolved to the same word, and the warning sat between two identical labels with nothing to reconcile it against. Read as a broken matcher, which is what the report said, and a fair reading of what was shown. Where both sides of a mismatch carry the same name they are now qualified by their hex, and the tooltip names them together: "Same type, different color: needs Blue (#0028FF), slot has Blue (#0A2989)". Names that already differ are left alone -- the hex is noise once the words separate them -- and a side with no name falls back to its hex rather than growing an empty bracket. The comparison is untouched. It was correct, and its tolerance is not something to widen on one report: a difference that size would start matching navy to cyan, and eligibility is the same rule the queue scheduler dispatches on, so loosening it would change which spool gets printed rather than only which warning gets shown. This issue was about being able to see why the warning fired, and a test pins that it still fires. The strings around it were hardcoded English: the panel's status line, the required-filament tooltip, the auto-matched marker, the slot placeholder, the mismatch detail and the type-not-found message. All nine now go through translation, in all thirteen locales. Two of them -- "Same type, different color" and "Filament type not loaded" -- turned out to have had translations sitting in every locale file the whole time, unused, while the component rendered the English literal beside them. The parity gate could not have caught any of this: keys that were never added have nothing to compare against. |
||
|
|
6988a30eae |
Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status response never carried it, so every consumer that wanted to tell a user why a print halted resolved the same 853 codes from its own duplicate of the same sentences -- this repo's Python table, the frontend modal's, and at least one third-party client whose catalogue exists purely because the server would not say. Each ages separately, and a relay watching a printer could only manage "your printer needs attention" while the server already knew it was "Filament ran out. Please load new filament." hms_errors[] entries now carry a description, defaulting to null so a client that has never seen the field is unaffected. It is resolved where the fault is parsed rather than at the boundary that prompted the request, because there are three serializers of a fault, not one: the status response, the WebSocket broadcast, and the completion payload the queue's failure reason is built from. Adding it to only the first would have handed half the feature to a relay watching the stream, which is the likelier consumer of the three. The queue's failure reason now quotes the resolved sentence instead of looking the code up a fourth time, and the notification path reads it rather than re-deriving. That they cannot report different text for one fault is the point, and a test asserts they agree. describe_fault is the single mapping from either code shape onto the table. An 8-char print_error is the catalogue's MMMM_EEEE key with the separator removed -- the parser derives full_code and that key from the same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier is tried whole and then collapsed to its first and last groups. That collapse is lossy, and keeping it was the decision worth making carefully. #2728 counts 65 documented faults falling onto 0300_0001 alone, so a hit can attribute a neighbour's sentence to this fault, and refusing it looks like the stricter reading. It is not: the notification path, the queue's failure-reason helper and the frontend modal have all resolved hms[] faults this way for as long as they have existed, and it resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape. Declining to collapse would have stopped describing faults that are described today, silently suppressed the notifications they raise, and left this field null while the UI showed text for the same fault. Narrowing it belongs with #2728, where both key spaces can move together. So the lookup is exactly what it was, verified rather than asserted: a test walks every catalogue code in both fault shapes across all three alert levels and checks the result against the derivation this replaces. A future change to the lookup cannot quietly stop notifications firing. The catalogue ships one language, so the field is English and unlocalized, which the schema and the API reference both say next to it. The camwall feed is deliberately left alone -- it is code-only because its token travels in a URL on a screen, and a readable sentence discloses more than the camera picture already does. The frontend keeps resolving its own text: switching it would change what filterKnownHMSErrors counts across eight call sites, which is #1840 and #2728's argument to have. HMSError.message goes with this -- a text field that was never set or read anywhere, and an invitation to populate the wrong one now that a live description sits beside it. ----- Record a failure code the user can actually look up The queue's failure reason formats a fault's module and error into MMMM_EEEE, and that one derivation never masked the error to 16 bits. A fault arriving from the printer's hms[] array carries its alert level in the code's high half, so the label came out as 0500_24038 -- five digits in a group that has four. It is not a code anyone can find on Bambu's HMS index, and because it matches no catalogue key the sentence explaining the failure was dropped along with it, leaving the bare number alone. The nozzle-size mismatch behind #1111 is exactly such a fault. Reported one way it read "[0500_4038] The nozzle diameter in sliced file is not consistent with the current nozzle setting"; reported the other, the same physical fault read "[0500_24038]" and nothing else. There is already a helper that gets this right, used by the archive's own failure-reason lookup, so this calls it instead of keeping a fourth copy of the derivation. It also takes the raw integer code the MQTT payload carries, which the local version only handled as a string. |
||
|
|
c094102614 |
Let a virtual printer be told which address to advertise
BambuStudio reads its FTP upload destination out of net.info[].ip in the MQTT status, and the bridge fills that field from the VP's bind address. On Docker bridge networking the two are different machines' worth of address: slicers reach Bambuddy on the host's LAN IP, the container binds something like 172.24.0.2, and that private address is what the slicer was handed -- so it opened an FTP connection to an address that does not exist on its network and the send stalled around 10%. VIRTUAL_PRINTER_ADVERTISE_ADDRESS supplies the address slicers actually use, taking precedence over the bind address and over the same-subnet host interface the bridge falls back to. The armed log line names its source, so (VIRTUAL_PRINTER_ADVERTISE_ADDRESS) against (bind_address) tells an operator whether the variable reached the container at all, and the not-armed diagnostic now names it as the remedy -- a bridge-network install that has not set it is exactly the one that cannot auto-resolve either, and until now saw only that nothing worked. An environment variable rather than a change to how the advertised address is resolved, which is the decision worth recording. The VP already has a "Network Interface Override" field, and reading it here is the smaller patch, but it feeds SSDP and the certificate SANs only: honouring it would silently move the upload destination on every install that has one set -- the multi-NIC, VLAN and Tailscale setups, which are the ones most likely to have been arrived at by hand and least likely to survive being second-guessed. Unset, this changes nothing, and a test pins that. A value that is not a dotted-quad IPv4 is refused with one warning naming it and the previous address is used instead. That direction is deliberate: declining to rewrite would put the real printer's IP back in front of the slicer, which is the leak the rewrite exists to close, so a typo must not be able to reopen it. 0.0.0.0 counts as unset and whitespace is stripped, for values pasted into a compose file. Host and macvlan networking need none of this and stay what Virtual Printer is developed against. The variable removes one blocker; it does not make bridge mode equivalent. The wiki said in three places that the host address could not be discovered at all, which is no longer true, so those now describe the variable and keep the recommendation. |
||
|
|
537b4d2509 |
Stop offering AMS slots as places to store a spool
The Storage Location dropdown listed entries like "H2D-1 - AMS A1" next to
real locations, and they could not be got rid of.
They were never locations. Bambuddy used to record which slot a spool was
loaded into by writing that string into Spoolman's location field, and the
writer went away when Storage Location became something the user picks --
but the strings stayed on people's Spoolman spools, and the location sync
imports every distinct one it finds, so they have been coming back in
through the front door ever since. A printer slot is where a spool is
loaded, not where it is put away, and slot assignments already track the
first.
Deleting one by hand did not work either, which is what made this a dead
end rather than an annoyance: the delete route refuses a location that has
spools, and in Spoolman mode it counts them by matching that same string,
so every marker still sitting on a loaded spool answered 409 -- and the two
that were empty were back on the next sync a minute later.
The import now skips them and a one-shot migration clears the ones already
in the catalogue. The shape is defined once and used by both: an optional
printer-name prefix followed by AMS A1, AMS-HT A1 or External Spool, which
is exactly what convert_ams_slot_to_location produced. It stays narrow on
purpose -- "AMS Drybox" and "Spare AMS trays" are somebody's shelf, and
anything the filter swallowed would be a place they could no longer file a
spool under -- so both directions are pinned by tests.
A row is only removed when no spool in this database points at it, by id or
by legacy free-text name, so an internal-mode user who has deliberately
filed spools under such a name keeps it. Spools in Spoolman are neither
consulted nor touched: their location strings are the user's data on the
user's server, and one that still reads "H2D-1 - AMS A1" in the inventory
list is telling the truth about what Spoolman holds. It simply stops being
offered as a destination.
Verified on a live Postgres instance carrying the reported symptom: 13
locations down to 3, all ten markers removed, the two real shelves and one
hand-typed Spoolman name left alone.
|
||
|
|
b38022ec5c |
Draw a spool the way the AMS described it, and correct the tare it was added with
Two faults in the same auto-add path, both found while tracing why an H2C
slot named a wood roll as plain PLA.
A spool's swatch is composed from effect_type and extra_colors, and the
RFID auto-add set neither. It reads the colour catalogue to name the
colour and took the name alone, even though the row it had in hand also
carries those two columns -- the spool form's own colour picker hands both
to a spool a user adds by hand, so the same roll rendered one way when you
typed it in and another when the printer identified it for you.
Both columns now travel with the name. That alone changes nothing on a
stock install, because the shipped catalogue carries an effect on none of
its 600-odd rows, so the subtype is read where the catalogue has none: it
is already derived from what the printer reports, and the two vocabularies
line up -- Wood, Silk, Sparkle, Marble, Glow, Galaxy, Metal, Rainbow,
Translucent, Matte, and the Gradient, Dual Color and Tri Color that the
M*/T* colour codes upgrade a subtype to. "Silk+" reads as Silk, since the
plus is on the product name rather than the finish. A subtype that names
no effect -- Basic, Tough, CF -- leaves the column empty rather than
inventing an overlay, and a value already set is never overwritten, so the
column stays what it is documented to be: a rendering hint the user can
override without touching Bambu's categorical label.
------
Correct the spool tare an RFID roll was added with (#2909)
The lookup that gave an auto-added spool its core_weight asked for the
first catalogue row whose name starts "Bambu Lab" and took whatever came
back. There are three, and which is first is the database's business:
SQLite returns insertion order in practice, Postgres promises nothing once
a table has seen an update. The same roll was therefore recorded with the
216 g High Temp tare on one install and correctly with the 250 g Low Temp
one on another. @ojimpo's forward fix picks the row by name; this repairs
the rows already written, which the forward fix cannot reach -- 22 of 26
RFID-added spools on the instance this was traced on.
The tare is not cosmetic. A spool weighed on SpoolBuddy has its remaining
filament worked out as the scale reading minus the tare, so a 34 g low
tare credits the roll with 34 g that is not there and writes a used weight
34 g short. That error is a constant -- every later print adds to the used
weight on top of it -- so adding the difference back is exact however much
has been printed since. It is applied only to spools that have been on the
scale; one that never was has a used weight derived from the AMS remaining
percentage, which the tare never entered into.
Rows are identified by the signature of the broken lookup: added by RFID,
carrying the weight of one of the other Bambu catalogue rows, with the
weights read out of the catalogue rather than hardcoded so an install
whose rows have been re-measured is repaired to its own numbers. Keying on
whether a catalogue row had been recorded would not have worked -- the
weight picker auto-selects the only row matching the weight and writes its
id on the next save, so that column says only whether the form was ever
opened. The one case that cannot be told apart is stated rather than
hidden: someone who moved an RFID roll onto a genuine High Temp spool and
set 216 g by hand is normalised with the rest. Runs exactly once, so a
tare set afterwards is kept.
|
||
|
|
87e0a4c3b6 |
Name a spool by its subtype on the slot it is assigned to
A spool's subtype is half of what it is called: "PLA" and "PLA Wood" are
different filaments. The AMS slot's hover card built the assigned-spool
line out of brand, material and colour name and left the subtype out, so
a roll of Bambu PLA Wood Classic Birch in an H2C's A4 was announced as
"Bambu Lab PLA - Classic Birch".
Everything else named it correctly at the same moment -- the RFID read,
the inventory row, the slot's own profile line, which is built from the
spool's slicer preset rather than reassembled, and Bambu Studio -- so the
one wrong line read like a bad tag read rather than a display fault.
It was not only the render. The card's assignedSpool prop had no subtype
field at all, and the six places the printer card fills it in -- regular
AMS, AMS-HT and external spool, each in both Spoolman and internal-
inventory mode -- never passed one, so the value could not reach the
component. The field is required rather than optional, which is what
stops the next call site from quietly omitting it; that omission is the
whole of this bug.
Three more surfaces rebuilt the name the same way and are fixed with it:
the SpoolBuddy AMS slot panel in both inventory modes, and the write-tag
confirmation. Every other place a spool is named -- the assign dialogs,
the inventory cards, the forecast rows, the label picker -- already
included the subtype, so these four were the outliers.
This is the display-side half of #2902, which stopped the backend
reducing a filled or foamed filament onto its base material. The card was
doing the same thing to the same spools, one layer further out.
|
||
|
|
490f72fe21 | Updated CHANGELOG | ||
|
|
22ede4a128 |
Split the Windows installer build so signing can wait for approval
The SignPath Foundation production certificate does not sign on demand
the way the self-signed test certificate does. Every request has to be
approved by hand in the SignPath UI, because the Foundation verifies
what is being signed and which build produced it. The submitting action
waits for that approval with a default timeout of 600 seconds, which is
ample while the test policy approves in seconds and far too short once
the wait is a person noticing a tag went out. A tag pushed at night
would have failed the run ten minutes later with the installer already
compiled and thrown away.
The compile now ends in its own job, which uploads the unsigned artifact
and exposes its id. A second job downloads it, signs it, and does the
release-facing work, with the wait raised to an hour and the job timeout
sized to sit outside it. Separating them is what buys the recovery: the
artifact is uploaded before the wait begins and is addressed by id, so a
missed approval window costs a re-run of the second job alone rather
than a rebuild. Raising the timeout in place would not have given that.
The second job runs for unsigned builds too. Daily prereleases are
deliberately left unsigned to preserve the signing quota, and gating the
whole job on the signing decision would have meant a second copy of the
alias, artifact and release steps for them to run through.
The decision itself moves into a named step that echoes it, so a tag
that came out unsigned can be explained from the run log rather than by
re-reading the expression. It is one source of truth feeding both jobs,
which a job-level env could not be.
Every step body is otherwise unchanged. The property worth keeping is
that none of the alias, upload and release-attach steps carry always(),
so GitHub skips all three when signing fails or times out and an
unsigned .exe cannot reach a release; that is now written next to them,
because it is easy to break by adding a condition without noticing.
The policy slug stays at test-signing and the signature check stays
lenient -- the test certificate is self-signed and reports UnknownError,
so requiring Valid would fail every run until the production certificate
is imported. Both are the cutover. The restructure behaves identically
under the test policy, the request simply completing at once instead of
waiting, so it can be proven green beforehand.
|
||
|
|
f27b82355a | Updated BACKERS | ||
|
|
7f74f831c4 |
Let a filled or foamed filament keep its own name (issue #2902)
The reduction that gave an AMS slot a material type read PLA-AERO,
PLA-GF, ASA-GF and PPS-GF as their base material, so a slot loaded with
foaming or glass-filled filament went out saying plain PLA or ASA. That
is worse than the bug it replaced. "PLA-AERO" matched nothing before,
which was useless but honest; "PLA" matches every PLA plate in the
queue, so the dispatcher would have sent one to filament that will not
print it -- and the contract the first fix claimed, that it could only
ever repair a slot, no longer held. @doncaruana caught PLA Aero on the
issue.
All four are values Bambuddy itself offers: filament_fields.json is the
material list the Profiles editor puts in a dropdown, and the reduction
table was assembled from the cloud filament names and the frontend
preset parser without ever being checked against it. It is checked now,
so the next type added to one and not the other fails a test rather than
a print. ASA-AERO joins them from the cloud catalogue (GFB02).
The table hyphenates because the slicers do, while a spool says "PLA
Aero" and every Bambu preset name says "Bambu PLA Aero". Adjacent words
are joined and taken when the join is a type exactly -- exactly, because
letting the prefix and suffix rules reach across a space would make
"Support for PLA" a type by its tail.
Also from @doncaruana, and the better half of his point: a preset is
chosen from a list the slicer defines, so it already knows its own type
and nothing has to be read out of a product name. The resolver now hands
that answer back and both assign routes prefer it. It cannot be the only
source -- material is required on a spool and slicer_filament is not, and
the spool this issue was reported for had no preset at all -- so the
reduction stays as the fallback for spools without one.
Two things had to move with it. The auto-unlink guard compared the
slot's reported type against the reduced material, so a spool whose
preset outranked its material column would have been unlinked from the
slot it had just been assigned to; it now accepts any type the assign
path could have written. And two lookups keyed by material took the
catch-all for a type they had no row for, which sent an ASA-GF spool out
at 200/240 -- too cold to extrude -- and preheated its chamber to
nothing. Both fall back to the base material last, so PLA-CF, PETG-CF
and PA-CF keep the rows they are listed with, and ASA-CF and ABS-GF pick
up ranges they had been missing all along.
What counts as a material name is decided by the base for the same
reason: saying yes throws the value away and rescues the slot from the
generic-material fallback, so the answer has to be no when that fallback
has nothing to offer. ABS-GF reduces to a generic ABS the printer can
resolve; PPS-CF reduces to nothing and is left as it stands. Adding a
type to the table therefore cannot quietly change that answer, which is
how these five slipped through in the first place.
------
Hand the bundled chamber-preheat table back the way it is read
Every lookup of the per-filament chamber map happens after the keys are
upper-cased, and the parser documents exactly that: keys uppercased,
DEFAULT always present so the resolution loop can index it
unconditionally. The three fallback paths returned the bundled constant
as declared, with the lowercase "default" row the Settings editor writes
and displays, so an install that had never opened the setting got a dict
the loop could not read its fallback out of and used a hardcoded 0 for
any filament without a row of its own.
It reported the right number only because that bundled default is 0.
Raising it would have changed nothing for everyone who had not
customised the map, with the map in Settings still showing the value
that was not being used.
The test that should have caught this asserted the fallback under either
spelling, and its docstring contradicted itself between title and
comment. It pins the contract now, over all four ways the parser can
fall back.
|
||
|
|
7fa9967db3 | Point the Watchtower recommendation at the maintained fork (issue #2917) | ||
|
|
147042cc64 | Updated BACKERS | ||
|
|
6672062859 | Light the generated thumbnails so one model differs from another (#2816) (#2861) | ||
|
|
3f78ce8119 | Post work PR #2853 | ||
|
|
89f3b1cc58 | Add printer video downloads and range selection (#2853) | ||
|
|
a004581a88 | Report the selected plate on the archives API (#2796) (#2871) | ||
|
|
73db4f174e |
Register a Spoolman extra field with its own write (issue #2903)
Spoolman rejects a spool whose extra dict carries a key it has not been
told about, answering 400 "Unknown extra field tag.". Bambuddy keeps the
tray UUID in extra.tag, so that key has to exist before the first spool
is created. Registration ran from three hand-maintained lists that fire
when the integration is set up -- the connect route, startup, and two
inline blocks in the inventory routes. Enabling Spoolman from the
Settings page reaches none of them, so the first AMS sync on a fresh
Spoolman failed on every slot while vendor and filament creation
succeeded.
Neither fix suggested on the issue is quite the right shape. Adding the
block to PUT /settings/spoolman fixes this path and makes a third copy
of a list that has already drifted -- it would still omit
bambu_color_name. Ensuring at the sync entry point leaves the other four
tag writers alone: linking and unlinking a tag, and both inventory edit
paths.
So the registration moved to the write. create_spool, update_spool and
update_spool_full each register the keys of the extra dict they are
about to send, once per client, before sending. Every tag writer funnels
through one of the three, merge_spool_extra included. This closes the
class rather than the instance: a write that carries a key is a write
that registers it, and bambu_color_name shows why that matters -- it
never made it into the connect or startup lists at all, and works today
only because two call sites remembered it by hand.
Best-effort, deliberately. ensure_extra_field already logs and returns
False rather than raising, so a registration that fails leaves the write
to be attempted and to report exactly what it reported before. Failures
are not memoised either, so a Spoolman that was merely restarting gets
another try on the next write.
The older blocks stay. They are redundant now, but the inventory routes'
inline calls are pinned by tests that assert them against a mocked
client, where the funnel cannot run.
The status endpoint is the other half. The Connect button would have
registered the fields, and the reason nobody reaches it is that
GET /spoolman/status reported "connected" whenever an earlier request
had left a client object behind. Roughly twenty call sites build one
lazily, and saving the Settings page builds one as a side effect of
syncing locations, so the flag turned on which page had been opened
rather than on anything about Spoolman. The UI reads it twice -- Connect
only while disconnected, the sync section only while connected -- so
those two controls landed in states the user cannot explain. It now asks
the Spoolman that is configured, including the stale-URL check every
other route already does, and does not probe at all when the integration
is switched off, which used to let a leftover client report a disabled
Spoolman as connected.
That leaves nothing for Disconnect to do, so it is gone. Spoolman is a
stateless HTTP API with no session to close; the button dropped the
client object, the next request rebuilt it lazily, and the status
flipped back on its own within the 30s poll -- an action that looked
like it worked and then quietly undid itself. The enable toggle owns
turning the integration off. Connect stays as what it always was in
practice, a way to re-check a Spoolman that is not answering, and is
shown only then. Its translation keys are left in place; only the
control is removed.
Resolving the client there means the status poll can now fail in ways a
read-only check could not, so it no longer reports failure by failing.
Replacing a client closes the previous one and httpx's aclose() is not
guaranteed not to raise; a poll that runs every 30 seconds answering 500
is worse than one answering what is true either way, which is that
Spoolman could not be reached. The SSRF rejection keeps its own message
rather than folding into the general one -- a URL the guard refuses is
the admin's to correct, and that is only actionable if the log says so.
Tests drive the real client against a fake Spoolman that enforces the
unknown-extra-field rule rather than mocking it away, so each one fails
against the old code for the reason the reporter's install did. The
concurrency test needed the fake to be async: MockTransport answers
without suspending, so the first version ran each request to completion
in turn and passed just as happily with the lock removed.
|
||
|
|
f4166bf652 |
Give an AMS slot a material type, not a product name (issue #2902)
Assigning a spool wrote its material straight into the slot's tray_type.
A slot that says "PLA+" satisfies nothing that asks for PLA: not
OrcaSlicer, not Bambu Studio, and not Bambuddy's own dispatch matcher,
which compares the type the printer reports to the one the 3MF declares
as plain equality. The reporter's slot was unusable for every PLA plate
he had.
Not only a label, either. The same string went into the generic-filament
lookup, which missed, so the slot went out with no tray_info_idx at all
-- the half-configured state #2604 documents the printer as reverting
from -- and took the 200/240 catch-all nozzle range instead of PLA's
190/230.
PLA+ is not a special case. Bambuddy's own colour catalogue supplies the
material dropdown, and around forty of its values are vendor product
lines rather than filament types: HTPLA, PolyTerra PLA, PLA Matte, ASA
Extrafill, Flexfill TPU 98A.
So the four routes that configure a slot reduce the material to a name
the printer knows before sending it, and the product name moves to
tray_sub_brands -- which is where Bambu Lab puts it too: their catalogue
carries a preset named "eSUN PLA+" whose type is PLA. A name the
reduction cannot place is sent exactly as before rather than guessed at,
so this can only repair a slot, never break a working one. The spool's
own wording still leads the id and temperature lookups with the reduced
type appended behind it, so "PETG HF" keeps its own generic preset
(GFG96) rather than being traded down to plain PETG's.
Two guards decide whether a candidate filament id is really a material
name -- the resolver's, which discards one, and slot reuse, which will
not carry one forward. Both saw only bare types, so "PLA+" passed as a
filament id. They share one answer now, which also refuses to read an
id-shaped value: "GFPLA" ends in a material name, and reducing it would
throw away the calibrated preset in the slot.
One thing had to move with it. on_ams_change auto-unlinks an assignment
whose slot stopped looking the way it did when the spool was assigned,
and the check that spares a slot Bambuddy itself reconfigured compared
the printer's reported type against the spool's raw material. With the
slot now carrying the reduced type, every spool this issue is about
would have been unlinked from the slot it had just been assigned to.
Both sides are reduced there -- the printer's too, so slots configured
by an older version, still reporting "PLA+", keep matching.
Something starts working as a result: a slot holding a calibrated preset
is reused when a same-material spool is assigned to it, which could not
happen for these spools while "PLA" and "PLA+" compared unequal.
Reverting any one of the behaviours above fails a distinct test -- the
reduction's four matching rules and its pass-through contract included,
since that contract is what makes the rest of it safe.
|
||
|
|
dd7ffe10a5 |
Ask a printer that refuses FTPS what it actually said (issue #2780)
@grolmus measured a 9-printer farm and the numbers settle what this
failure is not. Reproduced here, three results:
cleartext "421" banner on the TLS port
-> [SSL: WRONG_VERSION_NUMBER] wrong version number (_ssl.c:1032)
1.2-only server, client forced to 1.3
-> [SSL: TLSV1_ALERT_PROTOCOL_VERSION]
1.2-only server, an uncapped client
-> negotiates 1.2 and connects
The first is byte-for-byte what the farm logs. So WRONG_VERSION_NUMBER
means the printer's first bytes were not a TLS record, a version
mismatch cannot produce it, and reaching a 1.2-only peer needs no cap.
What it still does not say is WHICH cleartext message, and that is the
part that would name the fault. OpenSSL has eaten those bytes by the
time the exception surfaces, so on this error the client now opens one
plain connection and reads them. The log then carries the printer's own
words -- an FTP refusal such as "421 Too many connections" would settle
it outright -- marked as the line to quote in a report. This gets the
answer from every affected install rather than from the one farm able
to take a packet capture.
Three things keep it from making the suspected fault worse:
- The failed socket is closed BEFORE the probe opens its connection.
Holding a dead handshake open across a second connect to a printer
that may be out of connection slots is the leak #2780's own cleanup
was added to stop.
- It asks once per cool-off window, not once per attempt. Checked
before the new deadline is written, so a live entry means an earlier
failure already asked -- which matters because a dispatch ignores the
cool-off (#2898) and reaches this branch four times.
- Connect and read share one timeout budget rather than getting one
each.
Only WRONG_VERSION_NUMBER is probed. A protocol-version alert means the
peer did speak TLS, so there is nothing in the clear to read and the
probe would only sit out its timeout. A vsFTPd answering its connection
limit by accepting and staying silent -- the other half of the standing
theory -- arrives as a handshake timeout and lands on that branch
instead; there is a test saying so, because widening the trigger later
would look like an improvement.
The profile registry is corrected to what was measured. Its docstring
claimed "the P2S evidently does offer 1.3"; six P2S units refuse it.
Worse, the X2D (#1638) and H2C (#2582) entries were capped on the
reading that WRONG_VERSION_NUMBER came from a TLS-1.3 ClientHello,
which cannot happen -- so the cap is not what changed those outcomes
and both are now marked RE-TEST WANTED. They are kept rather than
removed: their reporters saw the symptom clear, nobody here has that
hardware, and the entry costs nothing on a printer that does not offer
1.3 anyway. The P2S entry (#1401) is a different symptom -- a 426
truncation mid-transfer -- and is the only one a session-ticket problem
could explain, though grolmus's firmware refuses 1.3 there too.
Both measurements are pinned by tests, so the explanation stays
falsifiable instead of becoming the next set of confident wrong
comments. Two existing cool-off tests now count two connections where
they counted one; the promise they exist for -- contacted twice, not
~110 -- is unchanged, and they say why rather than carrying a new
number.
|
||
|
|
6b23666723 |
Say why an upload failed instead of blaming the SD card (issue #2899)
Every dispatch upload that failed carried one sentence: "Failed to
upload file to printer. Check if SD card is inserted and properly
formatted (FAT32/exFAT)." The reporter got it after a TLS handshake
failure and restarted the printer on the strength of it. That could not
have helped. The handshake never reached the printer's filesystem, and
the cool-off that made the next dispatch fail the same way lives in
Bambuddy's own memory, where power-cycling a printer does not reach.
because the advice was known not to work. It survived in the string
people actually read, so the failure mode that fix closed was still
reachable through the UI.
reachable through the UI.
The information was never missing. connect() separates five failure
classes and upload_file() separates 553/552/550, each with its own log
line -- 553 even logs a spelled-out list of storage causes -- and then
both returned a bare False. The dispatch had nothing left to work with
and guessed storage for all of them.
So the reason now travels with the result. The client records an
FtpFailure (kind, detail, and the reply code where the server gave one)
on every failure branch, and upload_file_async fills in a report object
the CALLER owns. Not a per-IP dict beside _mode_cache: those describe a
printer and are right to share, while this describes one operation, and
a background timelapse fetch running beside a dispatch would overwrite
the dispatch's reason with its own -- reporting the wrong cause with
total confidence, which is this bug again rather than a fix for it.
describe_upload_failure() picks the wording, and lives next to the kinds
so the two cannot drift. A 553 or 552 keeps the card advice, which is
the case it was written for, and quotes the reply code so a queue entry
and a support bundle line up. A handshake failure says the file service
answered without TLS and that the card is not involved. A refusal points
at the access code, a timeout at the network, and anything unclassified
says so and points at the log rather than picking a plausible cause. A
wrong instruction costs more than a vague one: it sends someone to work
on hardware that is fine. Nothing prescribes a power cycle.
The failure notification now carries the same sentence the queue shows,
instead of its own fixed "Failed to upload file to printer", so a push
and the screen cannot disagree about what happened.
Tests cover the classification, the report reaching the caller through
the retry loop, two callers not crossing, the queue entry itself, and
one line per message branch -- without that last one, deleting the
access-code or timeout branch left every other assertion passing, since
they only check that the card is not named and the generic message
satisfies that too. The card-advice test keys on the instruction rather
than the words "SD card", because the handshake message names the card
in order to rule it out.
|
||
|
|
a1e5afbd2d |
Keep a dispatch's retries out of the FTPS cool-off (issue #2898)
A failed TLS handshake arms a 300s per-IP cool-off, and connect()
consulted it for every caller. A print dispatch retries after 2s, so
once the cool-off was armed all four attempts were answered from the
gate rather than the network, and every further job queued for that
printer failed the same way for the rest of the window. The reporter's
farm lost three jobs to one handshake error, with the retry budget
contributing nothing to any of them.
The gate was serving two callers that want opposite things from it. The
background sweeps -- the post-print 3MF, cover and timelapse fetches --
walk ~110 candidate paths against one wedged printer with nobody
waiting, and backing off for minutes is right for them. A dispatch is
one delete plus at most four upload attempts with someone watching a
progress bar. So the split is by caller: a client built with
respect_handshake_cooloff=False goes to the printer regardless, and the
dispatch's delete and upload -- and a firmware upload, same shape --
opt out. Everything else keeps #2780's behaviour untouched.
In the reported trace it is the pre-upload delete that takes the SSL
error and arms the cool-off, 8ms before the upload's first attempt, so
exempting the upload alone would have left one dispatch's worth of the
problem in place.
Callers that do respect the cool-off no longer sleep out a retry loop
against it: with_ftp_retry takes the printer's IP and stops at the
attempt that armed the gate, instead of spending three more attempts
and six seconds on connections that cannot happen. It also reports the
attempts it really made -- "failed after 4 attempts" for one attempt is
part of how this read as a network problem.
Two diagnosis fixes go with it. The cool-off skip was the one connect()
failure path that reported without naming its cause, and at DEBUG, so
four identical reason-free warnings were all the operator saw. It now
says at WARNING that nothing was sent and how long the printer has
left, once per cool-off rather than once per attempt -- not every
caller is gated, and a download-zip of 200 files would otherwise repeat
the sentence 200 times, which is the flood #2780 set out to stop.
And a dispatch that fails this way no longer tells anyone to check
whether the SD card is inserted and formatted -- nothing reached the
printer's filesystem, so the card is the one part of the machine that
was working. The message names the file service and rules the card out.
It is used only when a handshake failed during the dispatch itself,
read from the cool-off deadline MOVING rather than merely being armed:
the dispatch ignores the gate, so it can be running underneath one an
unrelated background fetch left behind, and blaming TLS for an upload
that really hit a full disk would repeat the mistake in the other
direction.
Tests count sockets rather than return values, since "returned False"
looks identical whether or not anything was attempted -- which is what
made the original report a log dive. Reverting any one of the five
behaviours above fails a distinct test.
|
||
|
|
fa10414d0b |
Leave archived projects out of the pickers that file work (issue #2888)
The reporter opens a project per job and archives it when the job is
done, so the Project dropdown in Edit Archive listed five live projects
behind thirty-odd finished ones, in one unscrolled run with nothing to
tell them apart.
Archived is the state that means "put this away", so that is what the
pickers now drop: the Edit Archive dropdown, the pending-uploads panel,
the bulk Add to Project dialog and the File Manager's folder link.
Completed stays. It says the work is finished, not that it should be
hidden, and filing a reprint under a finished project is ordinary.
The Archives right-click submenu had the opposite bug and offered
active projects only, so a completed project was reachable from the
edit dialog and not from the menu next to it. All five surfaces share
one rule now.
Whatever a thing is already filed under survives the filter whatever
its status. A select holding a value that matches none of its options
is reset by the browser to the first one, and here that reads "No
project" -- an archive sitting in an archived project would have said
in as many words that it was filed nowhere. The stored id does survive
an untouched save; it is the field that lies.
The parent-project picker is deliberately untouched. A finished or
archived project is still a legal parent, and its own comment says so.
Fixed alongside it, and reported separately: the status tabs counted
only the projects the selected filter had already let through, so every
tab but the current one counted zero and dropped its badge. Switching
tabs moved the number rather than showing four of them. They are
counted from the unfiltered list the page already fetches for the
sub-project captions -- same query key, no extra request.
The new rule is one function with its own unit tests, since five
callers now depend on it reading the same way. Each half is pinned
separately: dropping the filter, dropping the kept id, restoring
active-only, and counting from the filtered list each fail their own
tests and nothing else.
|
||
|
|
b3638e7fb2 |
Stop the G-code preview from sizing the box that sizes it (issue #2887)
Opening a 3D Preview from Archives left an empty white pane with the
legend and the layer slider drawn over it, and the page's scrollbar
shrank for as long as it stayed open -- about 190px of page height a
second, with no limit.
The viewer appends its canvas into the very element it measures with
clientWidth/clientHeight and watches with a ResizeObserver. setSize
writes each new size onto the canvas as inline style, and three.js
leaves the canvas display:inline, so the line box adds descender space
on top of the height just set. Where that element takes its height from
its contents, the canvas sizes the box that sizes the canvas and gains a
fixed 33px every round -- the reporter measured container = canvas + 33
on every sample.
The page gave it no height to take instead. The viewer pane is flex-1
min-h-0, which divides nothing unless the column above it is a definite
height, and h-full is a percentage resolved against a main area whose
own height comes from a min-height -- a floor, not a size. So it fell
through to the content, and the content was the canvas.
Nothing was ever drawn because of the same loop, not a second fault:
every observer callback reallocated and cleared the frame buffer, and an
antialiased render of what had grown to roughly 18 megapixels never
finished before the next one arrived. The data path was fine throughout,
which the legend and the 1..57 layer slider both prove -- they are built
from the parsed toolpath.
The canvas is now positioned out of flow, so it cannot contribute to the
height of the element that measures it on any page, and that element
takes a definite height from the pane around it rather than a
percentage. display:block goes on too, for the case where something
overrides the positioning. The page is sized from the viewport the way
the File Manager page already was.
Either change alone stops the growth, but the structural one alone would
trade it for a collapsed pane: an out-of-flow canvas contributes nothing
to content height, so with no definite height above it the pane becomes
clientHeight || 1. They belong together.
The same viewer in the File Manager dialog was never affected -- a
dialog gives it a fixed height, so neither fault could arise there.
jsdom does no layout, so the loop cannot be reproduced in a test. The
structure that forbids it can: the new cases assert the canvas is out of
flow, that the measured element is definite-height rather than h-full,
and that the pane stays positioned so inset-0 resolves against it.
Reverting either change fails exactly those.
|
||
|
|
38abf57bb7 |
Let a print start on a nozzle the printer can fetch (issue #2885)
The nozzle-diameter guard compared the sliced diameter against the
mounted hotends alone. On an H2C both hotends commonly read the same
size, so a job sliced for anything else was failed before upload with
"install the matching nozzle before printing" -- even with that nozzle
sitting in the tool-changer rack, which the printer fetches by itself
as part of starting a print. The reporter saw it as an asymmetry:
going to 0.4mm always worked, going to 0.2mm never did, and only
fetching the nozzle by hand on the printer's own screen let the print
run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm
hotends, a 0.6mm slice was refused identically.
Placement is what made it fatal rather than merely wrong. The guard
runs near the top of _start_print and the rack picker near the bottom,
so the item was failed before the code that would have chosen the dock
ever ran.
Bambuddy had the rack contents the whole time. nozzle_info carries an
entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks --
each with its diameter, so the guard now tests the slice against both
sets. It keys off the ids rather than the printer model: only a rack
machine reports 16-21, which leaves no registry to keep in sync. An
empty dock is absent from the payload entirely, so an id appearing
there already means a nozzle is in it. stat is left uninterpreted; it
read 0 on every entry, occupied and empty alike.
A diameter in neither a hotend nor a dock still stops the print before
it uploads, and the message now names both sets so the machine's real
stock is visible.
The same telemetry showed a second fault, pointing the other way. A
hotend with nothing mounted is still reported, keeping the diameter of
the nozzle it last held -- measured at idle, where the rack-side hotend
read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle
back in the dock. That stale value counted as installed. Presence now
comes from the serial and the temperature rating, and emptiness has to
be stated rather than merely unstated: the serial must be the
firmware's explicit "N/A" and the rating absent. A firmware that
reports neither field normalises to exactly that, and reading it as
empty would switch the guard off on that machine.
Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job
dispatches with nozzle_mapping [21], chosen by Bambuddy rather than
left to the firmware.
|
||
|
|
7f8d79fe50 |
Split the Windows installer build so signing can wait for approval
The SignPath Foundation production certificate does not sign on demand the way the self-signed test certificate does. Every request has to be approved by hand in the SignPath UI, because the Foundation verifies what is being signed and which build produced it. The submitting action waits for that approval with a default timeout of 600 seconds, which is ample while the test policy approves in seconds and far too short once the wait is a person noticing a tag went out. A tag pushed at night would have failed the run ten minutes later with the installer already compiled and thrown away. The compile now ends in its own job, which uploads the unsigned artifact and exposes its id. A second job downloads it, signs it, and does the release-facing work, with the wait raised to an hour and the job timeout sized to sit outside it. Separating them is what buys the recovery: the artifact is uploaded before the wait begins and is addressed by id, so a missed approval window costs a re-run of the second job alone rather than a rebuild. Raising the timeout in place would not have given that. The second job runs for unsigned builds too. Daily prereleases are deliberately left unsigned to preserve the signing quota, and gating the whole job on the signing decision would have meant a second copy of the alias, artifact and release steps for them to run through. The decision itself moves into a named step that echoes it, so a tag that came out unsigned can be explained from the run log rather than by re-reading the expression. It is one source of truth feeding both jobs, which a job-level env could not be. Every step body is otherwise unchanged. The property worth keeping is that none of the alias, upload and release-attach steps carry always(), so GitHub skips all three when signing fails or times out and an unsigned .exe cannot reach a release; that is now written next to them, because it is easy to break by adding a condition without noticing. The policy slug stays at test-signing and the signature check stays lenient -- the test certificate is self-signed and reports UnknownError, so requiring Valid would fail every run until the production certificate is imported. Both are the cutover. The restructure behaves identically under the test policy, the request simply completing at once instead of waiting, so it can be proven green beforehand. |
||
|
|
1d011ecf60 | Updated BACKERS | ||
|
|
7b181b84f0 |
Let a filled or foamed filament keep its own name (issue #2902)
The reduction that gave an AMS slot a material type read PLA-AERO, PLA-GF, ASA-GF and PPS-GF as their base material, so a slot loaded with foaming or glass-filled filament went out saying plain PLA or ASA. That is worse than the bug it replaced. "PLA-AERO" matched nothing before, which was useless but honest; "PLA" matches every PLA plate in the queue, so the dispatcher would have sent one to filament that will not print it -- and the contract the first fix claimed, that it could only ever repair a slot, no longer held. @doncaruana caught PLA Aero on the issue. All four are values Bambuddy itself offers: filament_fields.json is the material list the Profiles editor puts in a dropdown, and the reduction table was assembled from the cloud filament names and the frontend preset parser without ever being checked against it. It is checked now, so the next type added to one and not the other fails a test rather than a print. ASA-AERO joins them from the cloud catalogue (GFB02). The table hyphenates because the slicers do, while a spool says "PLA Aero" and every Bambu preset name says "Bambu PLA Aero". Adjacent words are joined and taken when the join is a type exactly -- exactly, because letting the prefix and suffix rules reach across a space would make "Support for PLA" a type by its tail. Also from @doncaruana, and the better half of his point: a preset is chosen from a list the slicer defines, so it already knows its own type and nothing has to be read out of a product name. The resolver now hands that answer back and both assign routes prefer it. It cannot be the only source -- material is required on a spool and slicer_filament is not, and the spool this issue was reported for had no preset at all -- so the reduction stays as the fallback for spools without one. Two things had to move with it. The auto-unlink guard compared the slot's reported type against the reduced material, so a spool whose preset outranked its material column would have been unlinked from the slot it had just been assigned to; it now accepts any type the assign path could have written. And two lookups keyed by material took the catch-all for a type they had no row for, which sent an ASA-GF spool out at 200/240 -- too cold to extrude -- and preheated its chamber to nothing. Both fall back to the base material last, so PLA-CF, PETG-CF and PA-CF keep the rows they are listed with, and ASA-CF and ABS-GF pick up ranges they had been missing all along. What counts as a material name is decided by the base for the same reason: saying yes throws the value away and rescues the slot from the generic-material fallback, so the answer has to be no when that fallback has nothing to offer. ABS-GF reduces to a generic ABS the printer can resolve; PPS-CF reduces to nothing and is left as it stands. Adding a type to the table therefore cannot quietly change that answer, which is how these five slipped through in the first place. ------ Hand the bundled chamber-preheat table back the way it is read Every lookup of the per-filament chamber map happens after the keys are upper-cased, and the parser documents exactly that: keys uppercased, DEFAULT always present so the resolution loop can index it unconditionally. The three fallback paths returned the bundled constant as declared, with the lowercase "default" row the Settings editor writes and displays, so an install that had never opened the setting got a dict the loop could not read its fallback out of and used a hardcoded 0 for any filament without a row of its own. It reported the right number only because that bundled default is 0. Raising it would have changed nothing for everyone who had not customised the map, with the map in Settings still showing the value that was not being used. The test that should have caught this asserted the fallback under either spelling, and its docstring contradicted itself between title and comment. It pins the contract now, over all four ways the parser can fall back. |
||
|
|
0f3063aa1a | Point the Watchtower recommendation at the maintained fork (issue #2917) | ||
|
|
20bf108e55 | Updated BACKERS | ||
|
|
ed85677913 | Light the generated thumbnails so one model differs from another (#2816) (#2861) | ||
|
|
68140747f2 | Post work PR #2853 | ||
|
|
55cc64c87d | Add printer video downloads and range selection (#2853) | ||
|
|
937440f956 | Report the selected plate on the archives API (#2796) (#2871) | ||
|
|
4e40a5022c |
Register a Spoolman extra field with its own write (issue #2903)
Spoolman rejects a spool whose extra dict carries a key it has not been told about, answering 400 "Unknown extra field tag.". Bambuddy keeps the tray UUID in extra.tag, so that key has to exist before the first spool is created. Registration ran from three hand-maintained lists that fire when the integration is set up -- the connect route, startup, and two inline blocks in the inventory routes. Enabling Spoolman from the Settings page reaches none of them, so the first AMS sync on a fresh Spoolman failed on every slot while vendor and filament creation succeeded. Neither fix suggested on the issue is quite the right shape. Adding the block to PUT /settings/spoolman fixes this path and makes a third copy of a list that has already drifted -- it would still omit bambu_color_name. Ensuring at the sync entry point leaves the other four tag writers alone: linking and unlinking a tag, and both inventory edit paths. So the registration moved to the write. create_spool, update_spool and update_spool_full each register the keys of the extra dict they are about to send, once per client, before sending. Every tag writer funnels through one of the three, merge_spool_extra included. This closes the class rather than the instance: a write that carries a key is a write that registers it, and bambu_color_name shows why that matters -- it never made it into the connect or startup lists at all, and works today only because two call sites remembered it by hand. Best-effort, deliberately. ensure_extra_field already logs and returns False rather than raising, so a registration that fails leaves the write to be attempted and to report exactly what it reported before. Failures are not memoised either, so a Spoolman that was merely restarting gets another try on the next write. The older blocks stay. They are redundant now, but the inventory routes' inline calls are pinned by tests that assert them against a mocked client, where the funnel cannot run. The status endpoint is the other half. The Connect button would have registered the fields, and the reason nobody reaches it is that GET /spoolman/status reported "connected" whenever an earlier request had left a client object behind. Roughly twenty call sites build one lazily, and saving the Settings page builds one as a side effect of syncing locations, so the flag turned on which page had been opened rather than on anything about Spoolman. The UI reads it twice -- Connect only while disconnected, the sync section only while connected -- so those two controls landed in states the user cannot explain. It now asks the Spoolman that is configured, including the stale-URL check every other route already does, and does not probe at all when the integration is switched off, which used to let a leftover client report a disabled Spoolman as connected. That leaves nothing for Disconnect to do, so it is gone. Spoolman is a stateless HTTP API with no session to close; the button dropped the client object, the next request rebuilt it lazily, and the status flipped back on its own within the 30s poll -- an action that looked like it worked and then quietly undid itself. The enable toggle owns turning the integration off. Connect stays as what it always was in practice, a way to re-check a Spoolman that is not answering, and is shown only then. Its translation keys are left in place; only the control is removed. Resolving the client there means the status poll can now fail in ways a read-only check could not, so it no longer reports failure by failing. Replacing a client closes the previous one and httpx's aclose() is not guaranteed not to raise; a poll that runs every 30 seconds answering 500 is worse than one answering what is true either way, which is that Spoolman could not be reached. The SSRF rejection keeps its own message rather than folding into the general one -- a URL the guard refuses is the admin's to correct, and that is only actionable if the log says so. Tests drive the real client against a fake Spoolman that enforces the unknown-extra-field rule rather than mocking it away, so each one fails against the old code for the reason the reporter's install did. The concurrency test needed the fake to be async: MockTransport answers without suspending, so the first version ran each request to completion in turn and passed just as happily with the lock removed. |
||
|
|
88e8ca81c3 |
Give an AMS slot a material type, not a product name (issue #2902)
Assigning a spool wrote its material straight into the slot's tray_type. A slot that says "PLA+" satisfies nothing that asks for PLA: not OrcaSlicer, not Bambu Studio, and not Bambuddy's own dispatch matcher, which compares the type the printer reports to the one the 3MF declares as plain equality. The reporter's slot was unusable for every PLA plate he had. Not only a label, either. The same string went into the generic-filament lookup, which missed, so the slot went out with no tray_info_idx at all -- the half-configured state #2604 documents the printer as reverting from -- and took the 200/240 catch-all nozzle range instead of PLA's 190/230. PLA+ is not a special case. Bambuddy's own colour catalogue supplies the material dropdown, and around forty of its values are vendor product lines rather than filament types: HTPLA, PolyTerra PLA, PLA Matte, ASA Extrafill, Flexfill TPU 98A. So the four routes that configure a slot reduce the material to a name the printer knows before sending it, and the product name moves to tray_sub_brands -- which is where Bambu Lab puts it too: their catalogue carries a preset named "eSUN PLA+" whose type is PLA. A name the reduction cannot place is sent exactly as before rather than guessed at, so this can only repair a slot, never break a working one. The spool's own wording still leads the id and temperature lookups with the reduced type appended behind it, so "PETG HF" keeps its own generic preset (GFG96) rather than being traded down to plain PETG's. Two guards decide whether a candidate filament id is really a material name -- the resolver's, which discards one, and slot reuse, which will not carry one forward. Both saw only bare types, so "PLA+" passed as a filament id. They share one answer now, which also refuses to read an id-shaped value: "GFPLA" ends in a material name, and reducing it would throw away the calibrated preset in the slot. One thing had to move with it. on_ams_change auto-unlinks an assignment whose slot stopped looking the way it did when the spool was assigned, and the check that spares a slot Bambuddy itself reconfigured compared the printer's reported type against the spool's raw material. With the slot now carrying the reduced type, every spool this issue is about would have been unlinked from the slot it had just been assigned to. Both sides are reduced there -- the printer's too, so slots configured by an older version, still reporting "PLA+", keep matching. Something starts working as a result: a slot holding a calibrated preset is reused when a same-material spool is assigned to it, which could not happen for these spools while "PLA" and "PLA+" compared unequal. Reverting any one of the behaviours above fails a distinct test -- the reduction's four matching rules and its pass-through contract included, since that contract is what makes the rest of it safe. |
||
|
|
cc39acfc74 |
Ask a printer that refuses FTPS what it actually said (issue #2780)
@grolmus measured a 9-printer farm and the numbers settle what this
failure is not. Reproduced here, three results:
cleartext "421" banner on the TLS port
-> [SSL: WRONG_VERSION_NUMBER] wrong version number (_ssl.c:1032)
1.2-only server, client forced to 1.3
-> [SSL: TLSV1_ALERT_PROTOCOL_VERSION]
1.2-only server, an uncapped client
-> negotiates 1.2 and connects
The first is byte-for-byte what the farm logs. So WRONG_VERSION_NUMBER
means the printer's first bytes were not a TLS record, a version
mismatch cannot produce it, and reaching a 1.2-only peer needs no cap.
What it still does not say is WHICH cleartext message, and that is the
part that would name the fault. OpenSSL has eaten those bytes by the
time the exception surfaces, so on this error the client now opens one
plain connection and reads them. The log then carries the printer's own
words -- an FTP refusal such as "421 Too many connections" would settle
it outright -- marked as the line to quote in a report. This gets the
answer from every affected install rather than from the one farm able
to take a packet capture.
Three things keep it from making the suspected fault worse:
- The failed socket is closed BEFORE the probe opens its connection.
Holding a dead handshake open across a second connect to a printer
that may be out of connection slots is the leak #2780's own cleanup
was added to stop.
- It asks once per cool-off window, not once per attempt. Checked
before the new deadline is written, so a live entry means an earlier
failure already asked -- which matters because a dispatch ignores the
cool-off (#2898) and reaches this branch four times.
- Connect and read share one timeout budget rather than getting one
each.
Only WRONG_VERSION_NUMBER is probed. A protocol-version alert means the
peer did speak TLS, so there is nothing in the clear to read and the
probe would only sit out its timeout. A vsFTPd answering its connection
limit by accepting and staying silent -- the other half of the standing
theory -- arrives as a handshake timeout and lands on that branch
instead; there is a test saying so, because widening the trigger later
would look like an improvement.
The profile registry is corrected to what was measured. Its docstring
claimed "the P2S evidently does offer 1.3"; six P2S units refuse it.
Worse, the X2D (#1638) and H2C (#2582) entries were capped on the
reading that WRONG_VERSION_NUMBER came from a TLS-1.3 ClientHello,
which cannot happen -- so the cap is not what changed those outcomes
and both are now marked RE-TEST WANTED. They are kept rather than
removed: their reporters saw the symptom clear, nobody here has that
hardware, and the entry costs nothing on a printer that does not offer
1.3 anyway. The P2S entry (#1401) is a different symptom -- a 426
truncation mid-transfer -- and is the only one a session-ticket problem
could explain, though grolmus's firmware refuses 1.3 there too.
Both measurements are pinned by tests, so the explanation stays
falsifiable instead of becoming the next set of confident wrong
comments. Two existing cool-off tests now count two connections where
they counted one; the promise they exist for -- contacted twice, not
~110 -- is unchanged, and they say why rather than carrying a new
number.
|
||
|
|
70ee53464d |
Say why an upload failed instead of blaming the SD card (issue #2899)
Every dispatch upload that failed carried one sentence: "Failed to upload file to printer. Check if SD card is inserted and properly formatted (FAT32/exFAT)." The reporter got it after a TLS handshake failure and restarted the printer on the strength of it. That could not have helped. The handshake never reached the printer's filesystem, and the cool-off that made the next dispatch fail the same way lives in Bambuddy's own memory, where power-cycling a printer does not reach. because the advice was known not to work. It survived in the string people actually read, so the failure mode that fix closed was still reachable through the UI. reachable through the UI. The information was never missing. connect() separates five failure classes and upload_file() separates 553/552/550, each with its own log line -- 553 even logs a spelled-out list of storage causes -- and then both returned a bare False. The dispatch had nothing left to work with and guessed storage for all of them. So the reason now travels with the result. The client records an FtpFailure (kind, detail, and the reply code where the server gave one) on every failure branch, and upload_file_async fills in a report object the CALLER owns. Not a per-IP dict beside _mode_cache: those describe a printer and are right to share, while this describes one operation, and a background timelapse fetch running beside a dispatch would overwrite the dispatch's reason with its own -- reporting the wrong cause with total confidence, which is this bug again rather than a fix for it. describe_upload_failure() picks the wording, and lives next to the kinds so the two cannot drift. A 553 or 552 keeps the card advice, which is the case it was written for, and quotes the reply code so a queue entry and a support bundle line up. A handshake failure says the file service answered without TLS and that the card is not involved. A refusal points at the access code, a timeout at the network, and anything unclassified says so and points at the log rather than picking a plausible cause. A wrong instruction costs more than a vague one: it sends someone to work on hardware that is fine. Nothing prescribes a power cycle. The failure notification now carries the same sentence the queue shows, instead of its own fixed "Failed to upload file to printer", so a push and the screen cannot disagree about what happened. Tests cover the classification, the report reaching the caller through the retry loop, two callers not crossing, the queue entry itself, and one line per message branch -- without that last one, deleting the access-code or timeout branch left every other assertion passing, since they only check that the card is not named and the generic message satisfies that too. The card-advice test keys on the instruction rather than the words "SD card", because the handshake message names the card in order to rule it out. |
||
|
|
7c8f1f9435 |
Keep a dispatch's retries out of the FTPS cool-off (issue #2898)
A failed TLS handshake arms a 300s per-IP cool-off, and connect() consulted it for every caller. A print dispatch retries after 2s, so once the cool-off was armed all four attempts were answered from the gate rather than the network, and every further job queued for that printer failed the same way for the rest of the window. The reporter's farm lost three jobs to one handshake error, with the retry budget contributing nothing to any of them. The gate was serving two callers that want opposite things from it. The background sweeps -- the post-print 3MF, cover and timelapse fetches -- walk ~110 candidate paths against one wedged printer with nobody waiting, and backing off for minutes is right for them. A dispatch is one delete plus at most four upload attempts with someone watching a progress bar. So the split is by caller: a client built with respect_handshake_cooloff=False goes to the printer regardless, and the dispatch's delete and upload -- and a firmware upload, same shape -- opt out. Everything else keeps #2780's behaviour untouched. In the reported trace it is the pre-upload delete that takes the SSL error and arms the cool-off, 8ms before the upload's first attempt, so exempting the upload alone would have left one dispatch's worth of the problem in place. Callers that do respect the cool-off no longer sleep out a retry loop against it: with_ftp_retry takes the printer's IP and stops at the attempt that armed the gate, instead of spending three more attempts and six seconds on connections that cannot happen. It also reports the attempts it really made -- "failed after 4 attempts" for one attempt is part of how this read as a network problem. Two diagnosis fixes go with it. The cool-off skip was the one connect() failure path that reported without naming its cause, and at DEBUG, so four identical reason-free warnings were all the operator saw. It now says at WARNING that nothing was sent and how long the printer has left, once per cool-off rather than once per attempt -- not every caller is gated, and a download-zip of 200 files would otherwise repeat the sentence 200 times, which is the flood #2780 set out to stop. And a dispatch that fails this way no longer tells anyone to check whether the SD card is inserted and formatted -- nothing reached the printer's filesystem, so the card is the one part of the machine that was working. The message names the file service and rules the card out. It is used only when a handshake failed during the dispatch itself, read from the cool-off deadline MOVING rather than merely being armed: the dispatch ignores the gate, so it can be running underneath one an unrelated background fetch left behind, and blaming TLS for an upload that really hit a full disk would repeat the mistake in the other direction. Tests count sockets rather than return values, since "returned False" looks identical whether or not anything was attempted -- which is what made the original report a log dive. Reverting any one of the five behaviours above fails a distinct test. |
||
|
|
e4aab7b44b |
Leave archived projects out of the pickers that file work (issue #2888)
The reporter opens a project per job and archives it when the job is done, so the Project dropdown in Edit Archive listed five live projects behind thirty-odd finished ones, in one unscrolled run with nothing to tell them apart. Archived is the state that means "put this away", so that is what the pickers now drop: the Edit Archive dropdown, the pending-uploads panel, the bulk Add to Project dialog and the File Manager's folder link. Completed stays. It says the work is finished, not that it should be hidden, and filing a reprint under a finished project is ordinary. The Archives right-click submenu had the opposite bug and offered active projects only, so a completed project was reachable from the edit dialog and not from the menu next to it. All five surfaces share one rule now. Whatever a thing is already filed under survives the filter whatever its status. A select holding a value that matches none of its options is reset by the browser to the first one, and here that reads "No project" -- an archive sitting in an archived project would have said in as many words that it was filed nowhere. The stored id does survive an untouched save; it is the field that lies. The parent-project picker is deliberately untouched. A finished or archived project is still a legal parent, and its own comment says so. Fixed alongside it, and reported separately: the status tabs counted only the projects the selected filter had already let through, so every tab but the current one counted zero and dropped its badge. Switching tabs moved the number rather than showing four of them. They are counted from the unfiltered list the page already fetches for the sub-project captions -- same query key, no extra request. The new rule is one function with its own unit tests, since five callers now depend on it reading the same way. Each half is pinned separately: dropping the filter, dropping the kept id, restoring active-only, and counting from the filtered list each fail their own tests and nothing else. |
||
|
|
3916db822c |
Stop the G-code preview from sizing the box that sizes it (issue #2887)
Opening a 3D Preview from Archives left an empty white pane with the legend and the layer slider drawn over it, and the page's scrollbar shrank for as long as it stayed open -- about 190px of page height a second, with no limit. The viewer appends its canvas into the very element it measures with clientWidth/clientHeight and watches with a ResizeObserver. setSize writes each new size onto the canvas as inline style, and three.js leaves the canvas display:inline, so the line box adds descender space on top of the height just set. Where that element takes its height from its contents, the canvas sizes the box that sizes the canvas and gains a fixed 33px every round -- the reporter measured container = canvas + 33 on every sample. The page gave it no height to take instead. The viewer pane is flex-1 min-h-0, which divides nothing unless the column above it is a definite height, and h-full is a percentage resolved against a main area whose own height comes from a min-height -- a floor, not a size. So it fell through to the content, and the content was the canvas. Nothing was ever drawn because of the same loop, not a second fault: every observer callback reallocated and cleared the frame buffer, and an antialiased render of what had grown to roughly 18 megapixels never finished before the next one arrived. The data path was fine throughout, which the legend and the 1..57 layer slider both prove -- they are built from the parsed toolpath. The canvas is now positioned out of flow, so it cannot contribute to the height of the element that measures it on any page, and that element takes a definite height from the pane around it rather than a percentage. display:block goes on too, for the case where something overrides the positioning. The page is sized from the viewport the way the File Manager page already was. Either change alone stops the growth, but the structural one alone would trade it for a collapsed pane: an out-of-flow canvas contributes nothing to content height, so with no definite height above it the pane becomes clientHeight || 1. They belong together. The same viewer in the File Manager dialog was never affected -- a dialog gives it a fixed height, so neither fault could arise there. jsdom does no layout, so the loop cannot be reproduced in a test. The structure that forbids it can: the new cases assert the canvas is out of flow, that the measured element is definite-height rather than h-full, and that the pane stays positioned so inset-0 resolves against it. Reverting either change fails exactly those. |
||
|
|
4961990a7a |
Let a print start on a nozzle the printer can fetch (issue #2885)
The nozzle-diameter guard compared the sliced diameter against the mounted hotends alone. On an H2C both hotends commonly read the same size, so a job sliced for anything else was failed before upload with "install the matching nozzle before printing" -- even with that nozzle sitting in the tool-changer rack, which the printer fetches by itself as part of starting a print. The reporter saw it as an asymmetry: going to 0.4mm always worked, going to 0.2mm never did, and only fetching the nozzle by hand on the printer's own screen let the print run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm hotends, a 0.6mm slice was refused identically. Placement is what made it fatal rather than merely wrong. The guard runs near the top of _start_print and the rack picker near the bottom, so the item was failed before the code that would have chosen the dock ever ran. Bambuddy had the rack contents the whole time. nozzle_info carries an entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks -- each with its diameter, so the guard now tests the slice against both sets. It keys off the ids rather than the printer model: only a rack machine reports 16-21, which leaves no registry to keep in sync. An empty dock is absent from the payload entirely, so an id appearing there already means a nozzle is in it. stat is left uninterpreted; it read 0 on every entry, occupied and empty alike. A diameter in neither a hotend nor a dock still stops the print before it uploads, and the message now names both sets so the machine's real stock is visible. The same telemetry showed a second fault, pointing the other way. A hotend with nothing mounted is still reported, keeping the diameter of the nozzle it last held -- measured at idle, where the rack-side hotend read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle back in the dock. That stale value counted as installed. Presence now comes from the serial and the temperature rating, and emptiness has to be stated rather than merely unstated: the serial must be the firmware's explicit "N/A" and the rating absent. A firmware that reports neither field normalises to exactly that, and reading it as empty would switch the guard off on that machine. Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job dispatches with nozzle_mapping [21], chosen by Bambuddy rather than left to the firmware. |
||
|
|
6c76f6a133 | Updated CHANGELOG |