maziggy 32c945db39 Let one checkbox say where a slice's settings come from (issue #2942)
Two features in the slice dialog read as one. "Use the file's built-in
    settings" slices a 3MF the way its designer set it up, ignoring the picked
    profiles. The per-option "from file" ticks beside each setting carry the
    designer's individual deviations onto the profile you picked, and those
    arrived pre-ticked whatever the checkbox said. So a slice run deliberately
    without the file's settings still took sixteen values out of it -- the
    reporter's log names them, enable_support and support_type among them,
    landing on a process preset they had chosen on purpose.

    The ticks now follow the checkbox. Off, nothing comes out of the file until
    it is asked for by name; on, every setting the file changed shows ticked,
    because on that path the file really does drive the whole slice. Taking the
    designer's work in bulk is still one click, from a line at the top of the
    panel that says how many settings the file changed -- it is the only way
    left to reach them without hunting for chips across six pages of 348
    options -- and it still leaves the machine-tuned keys and the two that are
    the picked preset for a per-key decision.

    The panel greys out options the slicer's own rules switch off, and it was
    evaluating those rules against what the user had typed alone, falling back
    to the compiled-in schema defaults for the rest. A preset with supports on
    therefore read as enable_support: false and greyed out the whole Support
    page while the slice ran supports. A greyed row greyed its tick too, which
    is how the reporter's screenshot shows a support type marked "from file",
    applied to the slice, and impossible to clear. The rules now see what the
    slice will actually run with: the preset's values, the file's values for
    the keys that are on, and anything typed on top. The tick is no longer
    gated on those rules at all -- it answers a different question, not whether
    an option is in play but where its value comes from.

    Underneath both, the support carry-over ran outside the ticks entirely,
    lifting four keys out of any 3MF that had supports on with nothing on
    screen able to decline. It now stands down for the keys that were offered
    and turned down, which the request can say for the first time: an empty
    design_overrides list means the caller was shown the file's settings and
    took none, where no list at all is a caller that predates the choice. That
    distinction is what keeps the carry whole for sources with no deviations to
    tick, an OrcaSlicer export among them, rather than trading one silent
    default for another.

    Worth knowing: a Bambu Studio file with supports enabled no longer switches
    supports on for you. Tick Enable support, or the checkbox above the panel.
    Measured against the reporter's own sixteen keys, and covered by backend
    and frontend tests -- reverting any one of the three changes fails tests.
2026-08-26 10:15:48 +02:00
maziggy 818543c4f6 Say which blue a colour mismatch is about (issue #2941)
A print was refused a colour match between two filaments the dialog itself
    labelled "Blue". The comparison was right: the slicer profile asked for a
    near-pure #0028FF and the slot held Bambu's navy #0A2989, 118 apart in the
    blue channel alone and a CIEDE2000 distance of 15, where 1 is a
    just-noticeable difference. Nothing on screen said so. A hex that misses the
    colour catalogue is named by a coarse family bucket, so both sides resolved
    to the same word, and the warning sat between two identical labels with
    nothing to reconcile it against. Read as a broken matcher, which is what the
    report said, and a fair reading of what was shown.

    Where both sides of a mismatch carry the same name they are now qualified by
    their hex, and the tooltip names them together: "Same type, different color:
    needs Blue (#0028FF), slot has Blue (#0A2989)". Names that already differ are
    left alone -- the hex is noise once the words separate them -- and a side with
    no name falls back to its hex rather than growing an empty bracket.

    The comparison is untouched. It was correct, and its tolerance is not
    something to widen on one report: a difference that size would start matching
    navy to cyan, and eligibility is the same rule the queue scheduler dispatches
    on, so loosening it would change which spool gets printed rather than only
    which warning gets shown. This issue was about being able to see why the
    warning fired, and a test pins that it still fires.

    The strings around it were hardcoded English: the panel's status line, the
    required-filament tooltip, the auto-matched marker, the slot placeholder, the
    mismatch detail and the type-not-found message. All nine now go through
    translation, in all thirteen locales. Two of them -- "Same type, different
    color" and "Filament type not loaded" -- turned out to have had translations
    sitting in every locale file the whole time, unused, while the component
    rendered the English literal beside them. The parity gate could not have
    caught any of this: keys that were never added have nothing to compare
    against.
2026-08-26 10:15:30 +02:00
maziggy b212ba984a Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status
    response never carried it, so every consumer that wanted to tell a user
    why a print halted resolved the same 853 codes from its own duplicate of
    the same sentences -- this repo's Python table, the frontend modal's, and
    at least one third-party client whose catalogue exists purely because the
    server would not say. Each ages separately, and a relay watching a
    printer could only manage "your printer needs attention" while the server
    already knew it was "Filament ran out. Please load new filament."

    hms_errors[] entries now carry a description, defaulting to null so a
    client that has never seen the field is unaffected.

    It is resolved where the fault is parsed rather than at the boundary that
    prompted the request, because there are three serializers of a fault, not
    one: the status response, the WebSocket broadcast, and the completion
    payload the queue's failure reason is built from. Adding it to only the
    first would have handed half the feature to a relay watching the stream,
    which is the likelier consumer of the three. The queue's failure reason
    now quotes the resolved sentence instead of looking the code up a fourth
    time, and the notification path reads it rather than re-deriving. That
    they cannot report different text for one fault is the point, and a test
    asserts they agree.

    describe_fault is the single mapping from either code shape onto the
    table. An 8-char print_error is the catalogue's MMMM_EEEE key with the
    separator removed -- the parser derives full_code and that key from the
    same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier
    is tried whole and then collapsed to its first and last groups.

    That collapse is lossy, and keeping it was the decision worth making
    carefully. #2728 counts 65 documented faults falling onto 0300_0001
    alone, so a hit can attribute a neighbour's sentence to this fault, and
    refusing it looks like the stricter reading. It is not: the notification
    path, the queue's failure-reason helper and the frontend modal have all
    resolved hms[] faults this way for as long as they have existed, and it
    resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape.
    Declining to collapse would have stopped describing faults that are
    described today, silently suppressed the notifications they raise, and
    left this field null while the UI showed text for the same fault.
    Narrowing it belongs with #2728, where both key spaces can move together.

    So the lookup is exactly what it was, verified rather than asserted:
    a test walks every catalogue code in both fault shapes across all three
    alert levels and checks the result against the derivation this replaces.
    A future change to the lookup cannot quietly stop notifications firing.

    The catalogue ships one language, so the field is English and
    unlocalized, which the schema and the API reference both say next to it.
    The camwall feed is deliberately left alone -- it is code-only because
    its token travels in a URL on a screen, and a readable sentence discloses
    more than the camera picture already does. The frontend keeps resolving
    its own text: switching it would change what filterKnownHMSErrors counts
    across eight call sites, which is #1840 and #2728's argument to have.

    HMSError.message goes with this -- a text field that was never set or
    read anywhere, and an invitation to populate the wrong one now that a
    live description sits beside it.

    -----

    Record a failure code the user can actually look up

    The queue's failure reason formats a fault's module and error into
    MMMM_EEEE, and that one derivation never masked the error to 16 bits. A
    fault arriving from the printer's hms[] array carries its alert level in
    the code's high half, so the label came out as 0500_24038 -- five digits
    in a group that has four. It is not a code anyone can find on Bambu's HMS
    index, and because it matches no catalogue key the sentence explaining
    the failure was dropped along with it, leaving the bare number alone.

    The nozzle-size mismatch behind #1111 is exactly such a fault. Reported
    one way it read "[0500_4038] The nozzle diameter in sliced file is not
    consistent with the current nozzle setting"; reported the other, the same
    physical fault read "[0500_24038]" and nothing else.

    There is already a helper that gets this right, used by the archive's own
    failure-reason lookup, so this calls it instead of keeping a fourth copy
    of the derivation. It also takes the raw integer code the MQTT payload
    carries, which the local version only handled as a string.
2026-08-26 10:14:55 +02:00
maziggy 3da0c18c4d Let a virtual printer be told which address to advertise
BambuStudio reads its FTP upload destination out of net.info[].ip in the
    MQTT status, and the bridge fills that field from the VP's bind address.
    On Docker bridge networking the two are different machines' worth of
    address: slicers reach Bambuddy on the host's LAN IP, the container binds
    something like 172.24.0.2, and that private address is what the slicer was
    handed -- so it opened an FTP connection to an address that does not exist
    on its network and the send stalled around 10%.

    VIRTUAL_PRINTER_ADVERTISE_ADDRESS supplies the address slicers actually
    use, taking precedence over the bind address and over the same-subnet host
    interface the bridge falls back to. The armed log line names its source, so
    (VIRTUAL_PRINTER_ADVERTISE_ADDRESS) against (bind_address) tells an
    operator whether the variable reached the container at all, and the
    not-armed diagnostic now names it as the remedy -- a bridge-network install
    that has not set it is exactly the one that cannot auto-resolve either, and
    until now saw only that nothing worked.

    An environment variable rather than a change to how the advertised address
    is resolved, which is the decision worth recording. The VP already has a
    "Network Interface Override" field, and reading it here is the smaller
    patch, but it feeds SSDP and the certificate SANs only: honouring it would
    silently move the upload destination on every install that has one set --
    the multi-NIC, VLAN and Tailscale setups, which are the ones most likely to
    have been arrived at by hand and least likely to survive being
    second-guessed. Unset, this changes nothing, and a test pins that.

    A value that is not a dotted-quad IPv4 is refused with one warning naming
    it and the previous address is used instead. That direction is deliberate:
    declining to rewrite would put the real printer's IP back in front of the
    slicer, which is the leak the rewrite exists to close, so a typo must not
    be able to reopen it. 0.0.0.0 counts as unset and whitespace is stripped,
    for values pasted into a compose file.

    Host and macvlan networking need none of this and stay what Virtual Printer
    is developed against. The variable removes one blocker; it does not make
    bridge mode equivalent. The wiki said in three places that the host address
    could not be discovered at all, which is no longer true, so those now
    describe the variable and keep the recommendation.
2026-08-26 10:14:27 +02:00
maziggy 5de06cca0f Stop offering AMS slots as places to store a spool
The Storage Location dropdown listed entries like "H2D-1 - AMS A1" next to
        real locations, and they could not be got rid of.

        They were never locations. Bambuddy used to record which slot a spool was
        loaded into by writing that string into Spoolman's location field, and the
        writer went away when Storage Location became something the user picks --
        but the strings stayed on people's Spoolman spools, and the location sync
        imports every distinct one it finds, so they have been coming back in
        through the front door ever since. A printer slot is where a spool is
        loaded, not where it is put away, and slot assignments already track the
        first.

        Deleting one by hand did not work either, which is what made this a dead
        end rather than an annoyance: the delete route refuses a location that has
        spools, and in Spoolman mode it counts them by matching that same string,
        so every marker still sitting on a loaded spool answered 409 -- and the two
        that were empty were back on the next sync a minute later.

        The import now skips them and a one-shot migration clears the ones already
        in the catalogue. The shape is defined once and used by both: an optional
        printer-name prefix followed by AMS A1, AMS-HT A1 or External Spool, which
        is exactly what convert_ams_slot_to_location produced. It stays narrow on
        purpose -- "AMS Drybox" and "Spare AMS trays" are somebody's shelf, and
        anything the filter swallowed would be a place they could no longer file a
        spool under -- so both directions are pinned by tests.

        A row is only removed when no spool in this database points at it, by id or
        by legacy free-text name, so an internal-mode user who has deliberately
        filed spools under such a name keeps it. Spools in Spoolman are neither
        consulted nor touched: their location strings are the user's data on the
        user's server, and one that still reads "H2D-1 - AMS A1" in the inventory
        list is telling the truth about what Spoolman holds. It simply stops being
        offered as a destination.

        Verified on a live Postgres instance carrying the reported symptom: 13
        locations down to 3, all ten markers removed, the two real shelves and one
        hand-typed Spoolman name left alone.
2026-08-26 10:14:09 +02:00
maziggy 8c01e0f8ea Draw a spool the way the AMS described it, and correct the tare it was added with
Two faults in the same auto-add path, both found while tracing why an H2C
        slot named a wood roll as plain PLA.

        A spool's swatch is composed from effect_type and extra_colors, and the
        RFID auto-add set neither. It reads the colour catalogue to name the
        colour and took the name alone, even though the row it had in hand also
        carries those two columns -- the spool form's own colour picker hands both
        to a spool a user adds by hand, so the same roll rendered one way when you
        typed it in and another when the printer identified it for you.

        Both columns now travel with the name. That alone changes nothing on a
        stock install, because the shipped catalogue carries an effect on none of
        its 600-odd rows, so the subtype is read where the catalogue has none: it
        is already derived from what the printer reports, and the two vocabularies
        line up -- Wood, Silk, Sparkle, Marble, Glow, Galaxy, Metal, Rainbow,
        Translucent, Matte, and the Gradient, Dual Color and Tri Color that the
        M*/T* colour codes upgrade a subtype to. "Silk+" reads as Silk, since the
        plus is on the product name rather than the finish. A subtype that names
        no effect -- Basic, Tough, CF -- leaves the column empty rather than
        inventing an overlay, and a value already set is never overwritten, so the
        column stays what it is documented to be: a rendering hint the user can
        override without touching Bambu's categorical label.

        ------

        Correct the spool tare an RFID roll was added with (#2909)

        The lookup that gave an auto-added spool its core_weight asked for the
        first catalogue row whose name starts "Bambu Lab" and took whatever came
        back. There are three, and which is first is the database's business:
        SQLite returns insertion order in practice, Postgres promises nothing once
        a table has seen an update. The same roll was therefore recorded with the
        216 g High Temp tare on one install and correctly with the 250 g Low Temp
        one on another. @ojimpo's forward fix picks the row by name; this repairs
        the rows already written, which the forward fix cannot reach -- 22 of 26
        RFID-added spools on the instance this was traced on.

        The tare is not cosmetic. A spool weighed on SpoolBuddy has its remaining
        filament worked out as the scale reading minus the tare, so a 34 g low
        tare credits the roll with 34 g that is not there and writes a used weight
        34 g short. That error is a constant -- every later print adds to the used
        weight on top of it -- so adding the difference back is exact however much
        has been printed since. It is applied only to spools that have been on the
        scale; one that never was has a used weight derived from the AMS remaining
        percentage, which the tare never entered into.

        Rows are identified by the signature of the broken lookup: added by RFID,
        carrying the weight of one of the other Bambu catalogue rows, with the
        weights read out of the catalogue rather than hardcoded so an install
        whose rows have been re-measured is repaired to its own numbers. Keying on
        whether a catalogue row had been recorded would not have worked -- the
        weight picker auto-selects the only row matching the weight and writes its
        id on the next save, so that column says only whether the form was ever
        opened. The one case that cannot be told apart is stated rather than
        hidden: someone who moved an RFID roll onto a genuine High Temp spool and
        set 216 g by hand is normalised with the rest. Runs exactly once, so a
        tare set afterwards is kept.
2026-08-26 10:13:42 +02:00
maziggy 09d8ca351d Name a spool by its subtype on the slot it is assigned to
A spool's subtype is half of what it is called: "PLA" and "PLA Wood" are
        different filaments. The AMS slot's hover card built the assigned-spool
        line out of brand, material and colour name and left the subtype out, so
        a roll of Bambu PLA Wood Classic Birch in an H2C's A4 was announced as
        "Bambu Lab PLA - Classic Birch".

        Everything else named it correctly at the same moment -- the RFID read,
        the inventory row, the slot's own profile line, which is built from the
        spool's slicer preset rather than reassembled, and Bambu Studio -- so the
        one wrong line read like a bad tag read rather than a display fault.

        It was not only the render. The card's assignedSpool prop had no subtype
        field at all, and the six places the printer card fills it in -- regular
        AMS, AMS-HT and external spool, each in both Spoolman and internal-
        inventory mode -- never passed one, so the value could not reach the
        component. The field is required rather than optional, which is what
        stops the next call site from quietly omitting it; that omission is the
        whole of this bug.

        Three more surfaces rebuilt the name the same way and are fixed with it:
        the SpoolBuddy AMS slot panel in both inventory modes, and the write-tag
        confirmation. Every other place a spool is named -- the assign dialogs,
        the inventory cards, the forecast rows, the label picker -- already
        included the subtype, so these four were the outliers.

        This is the display-side half of #2902, which stopped the backend
        reducing a filled or foamed filament onto its base material. The card was
        doing the same thing to the same spools, one layer further out.
2026-08-26 10:13:19 +02:00
maziggy b1f5ec9642 Let one checkbox say where a slice's settings come from (issue #2942)
Two features in the slice dialog read as one. "Use the file's built-in
settings" slices a 3MF the way its designer set it up, ignoring the picked
profiles. The per-option "from file" ticks beside each setting carry the
designer's individual deviations onto the profile you picked, and those
arrived pre-ticked whatever the checkbox said. So a slice run deliberately
without the file's settings still took sixteen values out of it -- the
reporter's log names them, enable_support and support_type among them,
landing on a process preset they had chosen on purpose.

The ticks now follow the checkbox. Off, nothing comes out of the file until
it is asked for by name; on, every setting the file changed shows ticked,
because on that path the file really does drive the whole slice. Taking the
designer's work in bulk is still one click, from a line at the top of the
panel that says how many settings the file changed -- it is the only way
left to reach them without hunting for chips across six pages of 348
options -- and it still leaves the machine-tuned keys and the two that are
the picked preset for a per-key decision.

The panel greys out options the slicer's own rules switch off, and it was
evaluating those rules against what the user had typed alone, falling back
to the compiled-in schema defaults for the rest. A preset with supports on
therefore read as enable_support: false and greyed out the whole Support
page while the slice ran supports. A greyed row greyed its tick too, which
is how the reporter's screenshot shows a support type marked "from file",
applied to the slice, and impossible to clear. The rules now see what the
slice will actually run with: the preset's values, the file's values for
the keys that are on, and anything typed on top. The tick is no longer
gated on those rules at all -- it answers a different question, not whether
an option is in play but where its value comes from.

Underneath both, the support carry-over ran outside the ticks entirely,
lifting four keys out of any 3MF that had supports on with nothing on
screen able to decline. It now stands down for the keys that were offered
and turned down, which the request can say for the first time: an empty
design_overrides list means the caller was shown the file's settings and
took none, where no list at all is a caller that predates the choice. That
distinction is what keeps the carry whole for sources with no deviations to
tick, an OrcaSlicer export among them, rather than trading one silent
default for another.

Worth knowing: a Bambu Studio file with supports enabled no longer switches
supports on for you. Tick Enable support, or the checkbox above the panel.
Measured against the reporter's own sixteen keys, and covered by backend
and frontend tests -- reverting any one of the three changes fails tests.
2026-08-24 11:04:33 +02:00
maziggy cbbdab86f9 Say which blue a colour mismatch is about (issue #2941)
A print was refused a colour match between two filaments the dialog itself
labelled "Blue". The comparison was right: the slicer profile asked for a
near-pure #0028FF and the slot held Bambu's navy #0A2989, 118 apart in the
blue channel alone and a CIEDE2000 distance of 15, where 1 is a
just-noticeable difference. Nothing on screen said so. A hex that misses the
colour catalogue is named by a coarse family bucket, so both sides resolved
to the same word, and the warning sat between two identical labels with
nothing to reconcile it against. Read as a broken matcher, which is what the
report said, and a fair reading of what was shown.

Where both sides of a mismatch carry the same name they are now qualified by
their hex, and the tooltip names them together: "Same type, different color:
needs Blue (#0028FF), slot has Blue (#0A2989)". Names that already differ are
left alone -- the hex is noise once the words separate them -- and a side with
no name falls back to its hex rather than growing an empty bracket.

The comparison is untouched. It was correct, and its tolerance is not
something to widen on one report: a difference that size would start matching
navy to cyan, and eligibility is the same rule the queue scheduler dispatches
on, so loosening it would change which spool gets printed rather than only
which warning gets shown. This issue was about being able to see why the
warning fired, and a test pins that it still fires.

The strings around it were hardcoded English: the panel's status line, the
required-filament tooltip, the auto-matched marker, the slot placeholder, the
mismatch detail and the type-not-found message. All nine now go through
translation, in all thirteen locales. Two of them -- "Same type, different
color" and "Filament type not loaded" -- turned out to have had translations
sitting in every locale file the whole time, unused, while the component
rendered the English literal beside them. The parity gate could not have
caught any of this: keys that were never added have nothing to compare
against.
2026-08-24 10:14:31 +02:00
maziggy 6988a30eae Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status
response never carried it, so every consumer that wanted to tell a user
why a print halted resolved the same 853 codes from its own duplicate of
the same sentences -- this repo's Python table, the frontend modal's, and
at least one third-party client whose catalogue exists purely because the
server would not say. Each ages separately, and a relay watching a
printer could only manage "your printer needs attention" while the server
already knew it was "Filament ran out. Please load new filament."

hms_errors[] entries now carry a description, defaulting to null so a
client that has never seen the field is unaffected.

It is resolved where the fault is parsed rather than at the boundary that
prompted the request, because there are three serializers of a fault, not
one: the status response, the WebSocket broadcast, and the completion
payload the queue's failure reason is built from. Adding it to only the
first would have handed half the feature to a relay watching the stream,
which is the likelier consumer of the three. The queue's failure reason
now quotes the resolved sentence instead of looking the code up a fourth
time, and the notification path reads it rather than re-deriving. That
they cannot report different text for one fault is the point, and a test
asserts they agree.

describe_fault is the single mapping from either code shape onto the
table. An 8-char print_error is the catalogue's MMMM_EEEE key with the
separator removed -- the parser derives full_code and that key from the
same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier
is tried whole and then collapsed to its first and last groups.

That collapse is lossy, and keeping it was the decision worth making
carefully. #2728 counts 65 documented faults falling onto 0300_0001
alone, so a hit can attribute a neighbour's sentence to this fault, and
refusing it looks like the stricter reading. It is not: the notification
path, the queue's failure-reason helper and the frontend modal have all
resolved hms[] faults this way for as long as they have existed, and it
resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape.
Declining to collapse would have stopped describing faults that are
described today, silently suppressed the notifications they raise, and
left this field null while the UI showed text for the same fault.
Narrowing it belongs with #2728, where both key spaces can move together.

So the lookup is exactly what it was, verified rather than asserted:
a test walks every catalogue code in both fault shapes across all three
alert levels and checks the result against the derivation this replaces.
A future change to the lookup cannot quietly stop notifications firing.

The catalogue ships one language, so the field is English and
unlocalized, which the schema and the API reference both say next to it.
The camwall feed is deliberately left alone -- it is code-only because
its token travels in a URL on a screen, and a readable sentence discloses
more than the camera picture already does. The frontend keeps resolving
its own text: switching it would change what filterKnownHMSErrors counts
across eight call sites, which is #1840 and #2728's argument to have.

HMSError.message goes with this -- a text field that was never set or
read anywhere, and an invitation to populate the wrong one now that a
live description sits beside it.

-----

Record a failure code the user can actually look up

The queue's failure reason formats a fault's module and error into
MMMM_EEEE, and that one derivation never masked the error to 16 bits. A
fault arriving from the printer's hms[] array carries its alert level in
the code's high half, so the label came out as 0500_24038 -- five digits
in a group that has four. It is not a code anyone can find on Bambu's HMS
index, and because it matches no catalogue key the sentence explaining
the failure was dropped along with it, leaving the bare number alone.

The nozzle-size mismatch behind #1111 is exactly such a fault. Reported
one way it read "[0500_4038] The nozzle diameter in sliced file is not
consistent with the current nozzle setting"; reported the other, the same
physical fault read "[0500_24038]" and nothing else.

There is already a helper that gets this right, used by the archive's own
failure-reason lookup, so this calls it instead of keeping a fourth copy
of the derivation. It also takes the raw integer code the MQTT payload
carries, which the local version only handled as a string.
2026-08-24 09:47:39 +02:00
maziggy c094102614 Let a virtual printer be told which address to advertise
BambuStudio reads its FTP upload destination out of net.info[].ip in the
MQTT status, and the bridge fills that field from the VP's bind address.
On Docker bridge networking the two are different machines' worth of
address: slicers reach Bambuddy on the host's LAN IP, the container binds
something like 172.24.0.2, and that private address is what the slicer was
handed -- so it opened an FTP connection to an address that does not exist
on its network and the send stalled around 10%.

VIRTUAL_PRINTER_ADVERTISE_ADDRESS supplies the address slicers actually
use, taking precedence over the bind address and over the same-subnet host
interface the bridge falls back to. The armed log line names its source, so
(VIRTUAL_PRINTER_ADVERTISE_ADDRESS) against (bind_address) tells an
operator whether the variable reached the container at all, and the
not-armed diagnostic now names it as the remedy -- a bridge-network install
that has not set it is exactly the one that cannot auto-resolve either, and
until now saw only that nothing worked.

An environment variable rather than a change to how the advertised address
is resolved, which is the decision worth recording. The VP already has a
"Network Interface Override" field, and reading it here is the smaller
patch, but it feeds SSDP and the certificate SANs only: honouring it would
silently move the upload destination on every install that has one set --
the multi-NIC, VLAN and Tailscale setups, which are the ones most likely to
have been arrived at by hand and least likely to survive being
second-guessed. Unset, this changes nothing, and a test pins that.

A value that is not a dotted-quad IPv4 is refused with one warning naming
it and the previous address is used instead. That direction is deliberate:
declining to rewrite would put the real printer's IP back in front of the
slicer, which is the leak the rewrite exists to close, so a typo must not
be able to reopen it. 0.0.0.0 counts as unset and whitespace is stripped,
for values pasted into a compose file.

Host and macvlan networking need none of this and stay what Virtual Printer
is developed against. The variable removes one blocker; it does not make
bridge mode equivalent. The wiki said in three places that the host address
could not be discovered at all, which is no longer true, so those now
describe the variable and keep the recommendation.
2026-08-24 08:58:41 +02:00
maziggy 537b4d2509 Stop offering AMS slots as places to store a spool
The Storage Location dropdown listed entries like "H2D-1 - AMS A1" next to
    real locations, and they could not be got rid of.

    They were never locations. Bambuddy used to record which slot a spool was
    loaded into by writing that string into Spoolman's location field, and the
    writer went away when Storage Location became something the user picks --
    but the strings stayed on people's Spoolman spools, and the location sync
    imports every distinct one it finds, so they have been coming back in
    through the front door ever since. A printer slot is where a spool is
    loaded, not where it is put away, and slot assignments already track the
    first.

    Deleting one by hand did not work either, which is what made this a dead
    end rather than an annoyance: the delete route refuses a location that has
    spools, and in Spoolman mode it counts them by matching that same string,
    so every marker still sitting on a loaded spool answered 409 -- and the two
    that were empty were back on the next sync a minute later.

    The import now skips them and a one-shot migration clears the ones already
    in the catalogue. The shape is defined once and used by both: an optional
    printer-name prefix followed by AMS A1, AMS-HT A1 or External Spool, which
    is exactly what convert_ams_slot_to_location produced. It stays narrow on
    purpose -- "AMS Drybox" and "Spare AMS trays" are somebody's shelf, and
    anything the filter swallowed would be a place they could no longer file a
    spool under -- so both directions are pinned by tests.

    A row is only removed when no spool in this database points at it, by id or
    by legacy free-text name, so an internal-mode user who has deliberately
    filed spools under such a name keeps it. Spools in Spoolman are neither
    consulted nor touched: their location strings are the user's data on the
    user's server, and one that still reads "H2D-1 - AMS A1" in the inventory
    list is telling the truth about what Spoolman holds. It simply stops being
    offered as a destination.

    Verified on a live Postgres instance carrying the reported symptom: 13
    locations down to 3, all ten markers removed, the two real shelves and one
    hand-typed Spoolman name left alone.
2026-08-23 15:17:09 +02:00
maziggy b38022ec5c Draw a spool the way the AMS described it, and correct the tare it was added with
Two faults in the same auto-add path, both found while tracing why an H2C
    slot named a wood roll as plain PLA.

    A spool's swatch is composed from effect_type and extra_colors, and the
    RFID auto-add set neither. It reads the colour catalogue to name the
    colour and took the name alone, even though the row it had in hand also
    carries those two columns -- the spool form's own colour picker hands both
    to a spool a user adds by hand, so the same roll rendered one way when you
    typed it in and another when the printer identified it for you.

    Both columns now travel with the name. That alone changes nothing on a
    stock install, because the shipped catalogue carries an effect on none of
    its 600-odd rows, so the subtype is read where the catalogue has none: it
    is already derived from what the printer reports, and the two vocabularies
    line up -- Wood, Silk, Sparkle, Marble, Glow, Galaxy, Metal, Rainbow,
    Translucent, Matte, and the Gradient, Dual Color and Tri Color that the
    M*/T* colour codes upgrade a subtype to. "Silk+" reads as Silk, since the
    plus is on the product name rather than the finish. A subtype that names
    no effect -- Basic, Tough, CF -- leaves the column empty rather than
    inventing an overlay, and a value already set is never overwritten, so the
    column stays what it is documented to be: a rendering hint the user can
    override without touching Bambu's categorical label.

    ------

    Correct the spool tare an RFID roll was added with (#2909)

    The lookup that gave an auto-added spool its core_weight asked for the
    first catalogue row whose name starts "Bambu Lab" and took whatever came
    back. There are three, and which is first is the database's business:
    SQLite returns insertion order in practice, Postgres promises nothing once
    a table has seen an update. The same roll was therefore recorded with the
    216 g High Temp tare on one install and correctly with the 250 g Low Temp
    one on another. @ojimpo's forward fix picks the row by name; this repairs
    the rows already written, which the forward fix cannot reach -- 22 of 26
    RFID-added spools on the instance this was traced on.

    The tare is not cosmetic. A spool weighed on SpoolBuddy has its remaining
    filament worked out as the scale reading minus the tare, so a 34 g low
    tare credits the roll with 34 g that is not there and writes a used weight
    34 g short. That error is a constant -- every later print adds to the used
    weight on top of it -- so adding the difference back is exact however much
    has been printed since. It is applied only to spools that have been on the
    scale; one that never was has a used weight derived from the AMS remaining
    percentage, which the tare never entered into.

    Rows are identified by the signature of the broken lookup: added by RFID,
    carrying the weight of one of the other Bambu catalogue rows, with the
    weights read out of the catalogue rather than hardcoded so an install
    whose rows have been re-measured is repaired to its own numbers. Keying on
    whether a catalogue row had been recorded would not have worked -- the
    weight picker auto-selects the only row matching the weight and writes its
    id on the next save, so that column says only whether the form was ever
    opened. The one case that cannot be told apart is stated rather than
    hidden: someone who moved an RFID roll onto a genuine High Temp spool and
    set 216 g by hand is normalised with the rest. Runs exactly once, so a
    tare set afterwards is kept.
2026-08-23 14:25:45 +02:00
maziggy 87e0a4c3b6 Name a spool by its subtype on the slot it is assigned to
A spool's subtype is half of what it is called: "PLA" and "PLA Wood" are
    different filaments. The AMS slot's hover card built the assigned-spool
    line out of brand, material and colour name and left the subtype out, so
    a roll of Bambu PLA Wood Classic Birch in an H2C's A4 was announced as
    "Bambu Lab PLA - Classic Birch".

    Everything else named it correctly at the same moment -- the RFID read,
    the inventory row, the slot's own profile line, which is built from the
    spool's slicer preset rather than reassembled, and Bambu Studio -- so the
    one wrong line read like a bad tag read rather than a display fault.

    It was not only the render. The card's assignedSpool prop had no subtype
    field at all, and the six places the printer card fills it in -- regular
    AMS, AMS-HT and external spool, each in both Spoolman and internal-
    inventory mode -- never passed one, so the value could not reach the
    component. The field is required rather than optional, which is what
    stops the next call site from quietly omitting it; that omission is the
    whole of this bug.

    Three more surfaces rebuilt the name the same way and are fixed with it:
    the SpoolBuddy AMS slot panel in both inventory modes, and the write-tag
    confirmation. Every other place a spool is named -- the assign dialogs,
    the inventory cards, the forecast rows, the label picker -- already
    included the subtype, so these four were the outliers.

    This is the display-side half of #2902, which stopped the backend
    reducing a filled or foamed filament onto its base material. The card was
    doing the same thing to the same spools, one layer further out.
2026-08-23 13:52:32 +02:00
maziggy 490f72fe21 Updated CHANGELOG 2026-08-23 13:07:17 +02:00
maziggy 22ede4a128 Split the Windows installer build so signing can wait for approval
The SignPath Foundation production certificate does not sign on demand
    the way the self-signed test certificate does. Every request has to be
    approved by hand in the SignPath UI, because the Foundation verifies
    what is being signed and which build produced it. The submitting action
    waits for that approval with a default timeout of 600 seconds, which is
    ample while the test policy approves in seconds and far too short once
    the wait is a person noticing a tag went out. A tag pushed at night
    would have failed the run ten minutes later with the installer already
    compiled and thrown away.

    The compile now ends in its own job, which uploads the unsigned artifact
    and exposes its id. A second job downloads it, signs it, and does the
    release-facing work, with the wait raised to an hour and the job timeout
    sized to sit outside it. Separating them is what buys the recovery: the
    artifact is uploaded before the wait begins and is addressed by id, so a
    missed approval window costs a re-run of the second job alone rather
    than a rebuild. Raising the timeout in place would not have given that.

    The second job runs for unsigned builds too. Daily prereleases are
    deliberately left unsigned to preserve the signing quota, and gating the
    whole job on the signing decision would have meant a second copy of the
    alias, artifact and release steps for them to run through.

    The decision itself moves into a named step that echoes it, so a tag
    that came out unsigned can be explained from the run log rather than by
    re-reading the expression. It is one source of truth feeding both jobs,
    which a job-level env could not be.

    Every step body is otherwise unchanged. The property worth keeping is
    that none of the alias, upload and release-attach steps carry always(),
    so GitHub skips all three when signing fails or times out and an
    unsigned .exe cannot reach a release; that is now written next to them,
    because it is easy to break by adding a condition without noticing.

    The policy slug stays at test-signing and the signature check stays
    lenient -- the test certificate is self-signed and reports UnknownError,
    so requiring Valid would fail every run until the production certificate
    is imported. Both are the cutover. The restructure behaves identically
    under the test policy, the request simply completing at once instead of
    waiting, so it can be proven green beforehand.
2026-08-23 12:47:25 +02:00
maziggy f27b82355a Updated BACKERS 2026-08-23 12:47:11 +02:00
maziggy 7f74f831c4 Let a filled or foamed filament keep its own name (issue #2902)
The reduction that gave an AMS slot a material type read PLA-AERO,
    PLA-GF, ASA-GF and PPS-GF as their base material, so a slot loaded with
    foaming or glass-filled filament went out saying plain PLA or ASA. That
    is worse than the bug it replaced. "PLA-AERO" matched nothing before,
    which was useless but honest; "PLA" matches every PLA plate in the
    queue, so the dispatcher would have sent one to filament that will not
    print it -- and the contract the first fix claimed, that it could only
    ever repair a slot, no longer held. @doncaruana caught PLA Aero on the
    issue.

    All four are values Bambuddy itself offers: filament_fields.json is the
    material list the Profiles editor puts in a dropdown, and the reduction
    table was assembled from the cloud filament names and the frontend
    preset parser without ever being checked against it. It is checked now,
    so the next type added to one and not the other fails a test rather than
    a print. ASA-AERO joins them from the cloud catalogue (GFB02).

    The table hyphenates because the slicers do, while a spool says "PLA
    Aero" and every Bambu preset name says "Bambu PLA Aero". Adjacent words
    are joined and taken when the join is a type exactly -- exactly, because
    letting the prefix and suffix rules reach across a space would make
    "Support for PLA" a type by its tail.

    Also from @doncaruana, and the better half of his point: a preset is
    chosen from a list the slicer defines, so it already knows its own type
    and nothing has to be read out of a product name. The resolver now hands
    that answer back and both assign routes prefer it. It cannot be the only
    source -- material is required on a spool and slicer_filament is not, and
    the spool this issue was reported for had no preset at all -- so the
    reduction stays as the fallback for spools without one.

    Two things had to move with it. The auto-unlink guard compared the
    slot's reported type against the reduced material, so a spool whose
    preset outranked its material column would have been unlinked from the
    slot it had just been assigned to; it now accepts any type the assign
    path could have written. And two lookups keyed by material took the
    catch-all for a type they had no row for, which sent an ASA-GF spool out
    at 200/240 -- too cold to extrude -- and preheated its chamber to
    nothing. Both fall back to the base material last, so PLA-CF, PETG-CF
    and PA-CF keep the rows they are listed with, and ASA-CF and ABS-GF pick
    up ranges they had been missing all along.

    What counts as a material name is decided by the base for the same
    reason: saying yes throws the value away and rescues the slot from the
    generic-material fallback, so the answer has to be no when that fallback
    has nothing to offer. ABS-GF reduces to a generic ABS the printer can
    resolve; PPS-CF reduces to nothing and is left as it stands. Adding a
    type to the table therefore cannot quietly change that answer, which is
    how these five slipped through in the first place.

    ------

    Hand the bundled chamber-preheat table back the way it is read

    Every lookup of the per-filament chamber map happens after the keys are
    upper-cased, and the parser documents exactly that: keys uppercased,
    DEFAULT always present so the resolution loop can index it
    unconditionally. The three fallback paths returned the bundled constant
    as declared, with the lowercase "default" row the Settings editor writes
    and displays, so an install that had never opened the setting got a dict
    the loop could not read its fallback out of and used a hardcoded 0 for
    any filament without a row of its own.

    It reported the right number only because that bundled default is 0.
    Raising it would have changed nothing for everyone who had not
    customised the map, with the map in Settings still showing the value
    that was not being used.

    The test that should have caught this asserted the fallback under either
    spelling, and its docstring contradicted itself between title and
    comment. It pins the contract now, over all four ways the parser can
    fall back.
2026-08-23 12:46:48 +02:00
maziggy 7fa9967db3 Point the Watchtower recommendation at the maintained fork (issue #2917) 2026-08-23 12:46:29 +02:00
maziggy 147042cc64 Updated BACKERS 2026-08-23 12:46:19 +02:00
maziggy 6672062859 Light the generated thumbnails so one model differs from another (#2816) (#2861) 2026-08-23 12:46:04 +02:00
maziggy 3f78ce8119 Post work PR #2853 2026-08-23 12:45:52 +02:00
maziggy 89f3b1cc58 Add printer video downloads and range selection (#2853) 2026-08-23 12:45:39 +02:00
maziggy a004581a88 Report the selected plate on the archives API (#2796) (#2871) 2026-08-23 12:45:25 +02:00
maziggy 73db4f174e Register a Spoolman extra field with its own write (issue #2903)
Spoolman rejects a spool whose extra dict carries a key it has not been
    told about, answering 400 "Unknown extra field tag.". Bambuddy keeps the
    tray UUID in extra.tag, so that key has to exist before the first spool
    is created. Registration ran from three hand-maintained lists that fire
    when the integration is set up -- the connect route, startup, and two
    inline blocks in the inventory routes. Enabling Spoolman from the
    Settings page reaches none of them, so the first AMS sync on a fresh
    Spoolman failed on every slot while vendor and filament creation
    succeeded.

    Neither fix suggested on the issue is quite the right shape. Adding the
    block to PUT /settings/spoolman fixes this path and makes a third copy
    of a list that has already drifted -- it would still omit
    bambu_color_name. Ensuring at the sync entry point leaves the other four
    tag writers alone: linking and unlinking a tag, and both inventory edit
    paths.

    So the registration moved to the write. create_spool, update_spool and
    update_spool_full each register the keys of the extra dict they are
    about to send, once per client, before sending. Every tag writer funnels
    through one of the three, merge_spool_extra included. This closes the
    class rather than the instance: a write that carries a key is a write
    that registers it, and bambu_color_name shows why that matters -- it
    never made it into the connect or startup lists at all, and works today
    only because two call sites remembered it by hand.

    Best-effort, deliberately. ensure_extra_field already logs and returns
    False rather than raising, so a registration that fails leaves the write
    to be attempted and to report exactly what it reported before. Failures
    are not memoised either, so a Spoolman that was merely restarting gets
    another try on the next write.

    The older blocks stay. They are redundant now, but the inventory routes'
    inline calls are pinned by tests that assert them against a mocked
    client, where the funnel cannot run.

    The status endpoint is the other half. The Connect button would have
    registered the fields, and the reason nobody reaches it is that
    GET /spoolman/status reported "connected" whenever an earlier request
    had left a client object behind. Roughly twenty call sites build one
    lazily, and saving the Settings page builds one as a side effect of
    syncing locations, so the flag turned on which page had been opened
    rather than on anything about Spoolman. The UI reads it twice -- Connect
    only while disconnected, the sync section only while connected -- so
    those two controls landed in states the user cannot explain. It now asks
    the Spoolman that is configured, including the stale-URL check every
    other route already does, and does not probe at all when the integration
    is switched off, which used to let a leftover client report a disabled
    Spoolman as connected.

    That leaves nothing for Disconnect to do, so it is gone. Spoolman is a
    stateless HTTP API with no session to close; the button dropped the
    client object, the next request rebuilt it lazily, and the status
    flipped back on its own within the 30s poll -- an action that looked
    like it worked and then quietly undid itself. The enable toggle owns
    turning the integration off. Connect stays as what it always was in
    practice, a way to re-check a Spoolman that is not answering, and is
    shown only then. Its translation keys are left in place; only the
    control is removed.

    Resolving the client there means the status poll can now fail in ways a
    read-only check could not, so it no longer reports failure by failing.
    Replacing a client closes the previous one and httpx's aclose() is not
    guaranteed not to raise; a poll that runs every 30 seconds answering 500
    is worse than one answering what is true either way, which is that
    Spoolman could not be reached. The SSRF rejection keeps its own message
    rather than folding into the general one -- a URL the guard refuses is
    the admin's to correct, and that is only actionable if the log says so.

    Tests drive the real client against a fake Spoolman that enforces the
    unknown-extra-field rule rather than mocking it away, so each one fails
    against the old code for the reason the reporter's install did. The
    concurrency test needed the fake to be async: MockTransport answers
    without suspending, so the first version ran each request to completion
    in turn and passed just as happily with the lock removed.
2026-08-23 12:44:45 +02:00
maziggy f4166bf652 Give an AMS slot a material type, not a product name (issue #2902)
Assigning a spool wrote its material straight into the slot's tray_type.
    A slot that says "PLA+" satisfies nothing that asks for PLA: not
    OrcaSlicer, not Bambu Studio, and not Bambuddy's own dispatch matcher,
    which compares the type the printer reports to the one the 3MF declares
    as plain equality. The reporter's slot was unusable for every PLA plate
    he had.

    Not only a label, either. The same string went into the generic-filament
    lookup, which missed, so the slot went out with no tray_info_idx at all
    -- the half-configured state #2604 documents the printer as reverting
    from -- and took the 200/240 catch-all nozzle range instead of PLA's
    190/230.

    PLA+ is not a special case. Bambuddy's own colour catalogue supplies the
    material dropdown, and around forty of its values are vendor product
    lines rather than filament types: HTPLA, PolyTerra PLA, PLA Matte, ASA
    Extrafill, Flexfill TPU 98A.

    So the four routes that configure a slot reduce the material to a name
    the printer knows before sending it, and the product name moves to
    tray_sub_brands -- which is where Bambu Lab puts it too: their catalogue
    carries a preset named "eSUN PLA+" whose type is PLA. A name the
    reduction cannot place is sent exactly as before rather than guessed at,
    so this can only repair a slot, never break a working one. The spool's
    own wording still leads the id and temperature lookups with the reduced
    type appended behind it, so "PETG HF" keeps its own generic preset
    (GFG96) rather than being traded down to plain PETG's.

    Two guards decide whether a candidate filament id is really a material
    name -- the resolver's, which discards one, and slot reuse, which will
    not carry one forward. Both saw only bare types, so "PLA+" passed as a
    filament id. They share one answer now, which also refuses to read an
    id-shaped value: "GFPLA" ends in a material name, and reducing it would
    throw away the calibrated preset in the slot.

    One thing had to move with it. on_ams_change auto-unlinks an assignment
    whose slot stopped looking the way it did when the spool was assigned,
    and the check that spares a slot Bambuddy itself reconfigured compared
    the printer's reported type against the spool's raw material. With the
    slot now carrying the reduced type, every spool this issue is about
    would have been unlinked from the slot it had just been assigned to.
    Both sides are reduced there -- the printer's too, so slots configured
    by an older version, still reporting "PLA+", keep matching.

    Something starts working as a result: a slot holding a calibrated preset
    is reused when a same-material spool is assigned to it, which could not
    happen for these spools while "PLA" and "PLA+" compared unequal.

    Reverting any one of the behaviours above fails a distinct test -- the
    reduction's four matching rules and its pass-through contract included,
    since that contract is what makes the rest of it safe.
2026-08-23 12:44:18 +02:00
maziggy dd7ffe10a5 Ask a printer that refuses FTPS what it actually said (issue #2780)
@grolmus measured a 9-printer farm and the numbers settle what this
    failure is not. Reproduced here, three results:

      cleartext "421" banner on the TLS port
        -> [SSL: WRONG_VERSION_NUMBER] wrong version number (_ssl.c:1032)
      1.2-only server, client forced to 1.3
        -> [SSL: TLSV1_ALERT_PROTOCOL_VERSION]
      1.2-only server, an uncapped client
        -> negotiates 1.2 and connects

    The first is byte-for-byte what the farm logs. So WRONG_VERSION_NUMBER
    means the printer's first bytes were not a TLS record, a version
    mismatch cannot produce it, and reaching a 1.2-only peer needs no cap.

    What it still does not say is WHICH cleartext message, and that is the
    part that would name the fault. OpenSSL has eaten those bytes by the
    time the exception surfaces, so on this error the client now opens one
    plain connection and reads them. The log then carries the printer's own
    words -- an FTP refusal such as "421 Too many connections" would settle
    it outright -- marked as the line to quote in a report. This gets the
    answer from every affected install rather than from the one farm able
    to take a packet capture.

    Three things keep it from making the suspected fault worse:

    - The failed socket is closed BEFORE the probe opens its connection.
      Holding a dead handshake open across a second connect to a printer
      that may be out of connection slots is the leak #2780's own cleanup
      was added to stop.
    - It asks once per cool-off window, not once per attempt. Checked
      before the new deadline is written, so a live entry means an earlier
      failure already asked -- which matters because a dispatch ignores the
      cool-off (#2898) and reaches this branch four times.
    - Connect and read share one timeout budget rather than getting one
      each.

    Only WRONG_VERSION_NUMBER is probed. A protocol-version alert means the
    peer did speak TLS, so there is nothing in the clear to read and the
    probe would only sit out its timeout. A vsFTPd answering its connection
    limit by accepting and staying silent -- the other half of the standing
    theory -- arrives as a handshake timeout and lands on that branch
    instead; there is a test saying so, because widening the trigger later
    would look like an improvement.

    The profile registry is corrected to what was measured. Its docstring
    claimed "the P2S evidently does offer 1.3"; six P2S units refuse it.
    Worse, the X2D (#1638) and H2C (#2582) entries were capped on the
    reading that WRONG_VERSION_NUMBER came from a TLS-1.3 ClientHello,
    which cannot happen -- so the cap is not what changed those outcomes
    and both are now marked RE-TEST WANTED. They are kept rather than
    removed: their reporters saw the symptom clear, nobody here has that
    hardware, and the entry costs nothing on a printer that does not offer
    1.3 anyway. The P2S entry (#1401) is a different symptom -- a 426
    truncation mid-transfer -- and is the only one a session-ticket problem
    could explain, though grolmus's firmware refuses 1.3 there too.

    Both measurements are pinned by tests, so the explanation stays
    falsifiable instead of becoming the next set of confident wrong
    comments. Two existing cool-off tests now count two connections where
    they counted one; the promise they exist for -- contacted twice, not
    ~110 -- is unchanged, and they say why rather than carrying a new
    number.
2026-08-23 12:43:52 +02:00
maziggy 6b23666723 Say why an upload failed instead of blaming the SD card (issue #2899)
Every dispatch upload that failed carried one sentence: "Failed to
    upload file to printer. Check if SD card is inserted and properly
    formatted (FAT32/exFAT)." The reporter got it after a TLS handshake
    failure and restarted the printer on the strength of it. That could not
    have helped. The handshake never reached the printer's filesystem, and
    the cool-off that made the next dispatch fail the same way lives in
    Bambuddy's own memory, where power-cycling a printer does not reach.

    because the advice was known not to work. It survived in the string
    people actually read, so the failure mode that fix closed was still
    reachable through the UI.
    reachable through the UI.

    The information was never missing. connect() separates five failure
    classes and upload_file() separates 553/552/550, each with its own log
    line -- 553 even logs a spelled-out list of storage causes -- and then
    both returned a bare False. The dispatch had nothing left to work with
    and guessed storage for all of them.

    So the reason now travels with the result. The client records an
    FtpFailure (kind, detail, and the reply code where the server gave one)
    on every failure branch, and upload_file_async fills in a report object
    the CALLER owns. Not a per-IP dict beside _mode_cache: those describe a
    printer and are right to share, while this describes one operation, and
    a background timelapse fetch running beside a dispatch would overwrite
    the dispatch's reason with its own -- reporting the wrong cause with
    total confidence, which is this bug again rather than a fix for it.

    describe_upload_failure() picks the wording, and lives next to the kinds
    so the two cannot drift. A 553 or 552 keeps the card advice, which is
    the case it was written for, and quotes the reply code so a queue entry
    and a support bundle line up. A handshake failure says the file service
    answered without TLS and that the card is not involved. A refusal points
    at the access code, a timeout at the network, and anything unclassified
    says so and points at the log rather than picking a plausible cause. A
    wrong instruction costs more than a vague one: it sends someone to work
    on hardware that is fine. Nothing prescribes a power cycle.

    The failure notification now carries the same sentence the queue shows,
    instead of its own fixed "Failed to upload file to printer", so a push
    and the screen cannot disagree about what happened.

    Tests cover the classification, the report reaching the caller through
    the retry loop, two callers not crossing, the queue entry itself, and
    one line per message branch -- without that last one, deleting the
    access-code or timeout branch left every other assertion passing, since
    they only check that the card is not named and the generic message
    satisfies that too. The card-advice test keys on the instruction rather
    than the words "SD card", because the handshake message names the card
    in order to rule it out.
2026-08-23 12:43:25 +02:00
maziggy a1e5afbd2d Keep a dispatch's retries out of the FTPS cool-off (issue #2898)
A failed TLS handshake arms a 300s per-IP cool-off, and connect()
    consulted it for every caller. A print dispatch retries after 2s, so
    once the cool-off was armed all four attempts were answered from the
    gate rather than the network, and every further job queued for that
    printer failed the same way for the rest of the window. The reporter's
    farm lost three jobs to one handshake error, with the retry budget
    contributing nothing to any of them.

    The gate was serving two callers that want opposite things from it. The
    background sweeps -- the post-print 3MF, cover and timelapse fetches --
    walk ~110 candidate paths against one wedged printer with nobody
    waiting, and backing off for minutes is right for them. A dispatch is
    one delete plus at most four upload attempts with someone watching a
    progress bar. So the split is by caller: a client built with
    respect_handshake_cooloff=False goes to the printer regardless, and the
    dispatch's delete and upload -- and a firmware upload, same shape --
    opt out. Everything else keeps #2780's behaviour untouched.

    In the reported trace it is the pre-upload delete that takes the SSL
    error and arms the cool-off, 8ms before the upload's first attempt, so
    exempting the upload alone would have left one dispatch's worth of the
    problem in place.

    Callers that do respect the cool-off no longer sleep out a retry loop
    against it: with_ftp_retry takes the printer's IP and stops at the
    attempt that armed the gate, instead of spending three more attempts
    and six seconds on connections that cannot happen. It also reports the
    attempts it really made -- "failed after 4 attempts" for one attempt is
    part of how this read as a network problem.

    Two diagnosis fixes go with it. The cool-off skip was the one connect()
    failure path that reported without naming its cause, and at DEBUG, so
    four identical reason-free warnings were all the operator saw. It now
    says at WARNING that nothing was sent and how long the printer has
    left, once per cool-off rather than once per attempt -- not every
    caller is gated, and a download-zip of 200 files would otherwise repeat
    the sentence 200 times, which is the flood #2780 set out to stop.

    And a dispatch that fails this way no longer tells anyone to check
    whether the SD card is inserted and formatted -- nothing reached the
    printer's filesystem, so the card is the one part of the machine that
    was working. The message names the file service and rules the card out.
    It is used only when a handshake failed during the dispatch itself,
    read from the cool-off deadline MOVING rather than merely being armed:
    the dispatch ignores the gate, so it can be running underneath one an
    unrelated background fetch left behind, and blaming TLS for an upload
    that really hit a full disk would repeat the mistake in the other
    direction.

    Tests count sockets rather than return values, since "returned False"
    looks identical whether or not anything was attempted -- which is what
    made the original report a log dive. Reverting any one of the five
    behaviours above fails a distinct test.
2026-08-23 12:43:00 +02:00
maziggy fa10414d0b Leave archived projects out of the pickers that file work (issue #2888)
The reporter opens a project per job and archives it when the job is
    done, so the Project dropdown in Edit Archive listed five live projects
    behind thirty-odd finished ones, in one unscrolled run with nothing to
    tell them apart.

    Archived is the state that means "put this away", so that is what the
    pickers now drop: the Edit Archive dropdown, the pending-uploads panel,
    the bulk Add to Project dialog and the File Manager's folder link.
    Completed stays. It says the work is finished, not that it should be
    hidden, and filing a reprint under a finished project is ordinary.

    The Archives right-click submenu had the opposite bug and offered
    active projects only, so a completed project was reachable from the
    edit dialog and not from the menu next to it. All five surfaces share
    one rule now.

    Whatever a thing is already filed under survives the filter whatever
    its status. A select holding a value that matches none of its options
    is reset by the browser to the first one, and here that reads "No
    project" -- an archive sitting in an archived project would have said
    in as many words that it was filed nowhere. The stored id does survive
    an untouched save; it is the field that lies.

    The parent-project picker is deliberately untouched. A finished or
    archived project is still a legal parent, and its own comment says so.

    Fixed alongside it, and reported separately: the status tabs counted
    only the projects the selected filter had already let through, so every
    tab but the current one counted zero and dropped its badge. Switching
    tabs moved the number rather than showing four of them. They are
    counted from the unfiltered list the page already fetches for the
    sub-project captions -- same query key, no extra request.

    The new rule is one function with its own unit tests, since five
    callers now depend on it reading the same way. Each half is pinned
    separately: dropping the filter, dropping the kept id, restoring
    active-only, and counting from the filtered list each fail their own
    tests and nothing else.
2026-08-23 12:42:41 +02:00
maziggy b3638e7fb2 Stop the G-code preview from sizing the box that sizes it (issue #2887)
Opening a 3D Preview from Archives left an empty white pane with the
    legend and the layer slider drawn over it, and the page's scrollbar
    shrank for as long as it stayed open -- about 190px of page height a
    second, with no limit.

    The viewer appends its canvas into the very element it measures with
    clientWidth/clientHeight and watches with a ResizeObserver. setSize
    writes each new size onto the canvas as inline style, and three.js
    leaves the canvas display:inline, so the line box adds descender space
    on top of the height just set. Where that element takes its height from
    its contents, the canvas sizes the box that sizes the canvas and gains a
    fixed 33px every round -- the reporter measured container = canvas + 33
    on every sample.

    The page gave it no height to take instead. The viewer pane is flex-1
    min-h-0, which divides nothing unless the column above it is a definite
    height, and h-full is a percentage resolved against a main area whose
    own height comes from a min-height -- a floor, not a size. So it fell
    through to the content, and the content was the canvas.

    Nothing was ever drawn because of the same loop, not a second fault:
    every observer callback reallocated and cleared the frame buffer, and an
    antialiased render of what had grown to roughly 18 megapixels never
    finished before the next one arrived. The data path was fine throughout,
    which the legend and the 1..57 layer slider both prove -- they are built
    from the parsed toolpath.

    The canvas is now positioned out of flow, so it cannot contribute to the
    height of the element that measures it on any page, and that element
    takes a definite height from the pane around it rather than a
    percentage. display:block goes on too, for the case where something
    overrides the positioning. The page is sized from the viewport the way
    the File Manager page already was.

    Either change alone stops the growth, but the structural one alone would
    trade it for a collapsed pane: an out-of-flow canvas contributes nothing
    to content height, so with no definite height above it the pane becomes
    clientHeight || 1. They belong together.

    The same viewer in the File Manager dialog was never affected -- a
    dialog gives it a fixed height, so neither fault could arise there.

    jsdom does no layout, so the loop cannot be reproduced in a test. The
    structure that forbids it can: the new cases assert the canvas is out of
    flow, that the measured element is definite-height rather than h-full,
    and that the pane stays positioned so inset-0 resolves against it.
    Reverting either change fails exactly those.
2026-08-23 12:42:16 +02:00
maziggy 38abf57bb7 Let a print start on a nozzle the printer can fetch (issue #2885)
The nozzle-diameter guard compared the sliced diameter against the
    mounted hotends alone. On an H2C both hotends commonly read the same
    size, so a job sliced for anything else was failed before upload with
    "install the matching nozzle before printing" -- even with that nozzle
    sitting in the tool-changer rack, which the printer fetches by itself
    as part of starting a print. The reporter saw it as an asymmetry:
    going to 0.4mm always worked, going to 0.2mm never did, and only
    fetching the nozzle by hand on the printer's own screen let the print
    run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm
    hotends, a 0.6mm slice was refused identically.

    Placement is what made it fatal rather than merely wrong. The guard
    runs near the top of _start_print and the rack picker near the bottom,
    so the item was failed before the code that would have chosen the dock
    ever ran.

    Bambuddy had the rack contents the whole time. nozzle_info carries an
    entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks --
    each with its diameter, so the guard now tests the slice against both
    sets. It keys off the ids rather than the printer model: only a rack
    machine reports 16-21, which leaves no registry to keep in sync. An
    empty dock is absent from the payload entirely, so an id appearing
    there already means a nozzle is in it. stat is left uninterpreted; it
    read 0 on every entry, occupied and empty alike.

    A diameter in neither a hotend nor a dock still stops the print before
    it uploads, and the message now names both sets so the machine's real
    stock is visible.

    The same telemetry showed a second fault, pointing the other way. A
    hotend with nothing mounted is still reported, keeping the diameter of
    the nozzle it last held -- measured at idle, where the rack-side hotend
    read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle
    back in the dock. That stale value counted as installed. Presence now
    comes from the serial and the temperature rating, and emptiness has to
    be stated rather than merely unstated: the serial must be the
    firmware's explicit "N/A" and the rating absent. A firmware that
    reports neither field normalises to exactly that, and reading it as
    empty would switch the guard off on that machine.

    Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job
    dispatches with nozzle_mapping [21], chosen by Bambuddy rather than
    left to the firmware.
2026-08-23 12:41:45 +02:00
maziggy 7f8d79fe50 Split the Windows installer build so signing can wait for approval
The SignPath Foundation production certificate does not sign on demand
the way the self-signed test certificate does. Every request has to be
approved by hand in the SignPath UI, because the Foundation verifies
what is being signed and which build produced it. The submitting action
waits for that approval with a default timeout of 600 seconds, which is
ample while the test policy approves in seconds and far too short once
the wait is a person noticing a tag went out. A tag pushed at night
would have failed the run ten minutes later with the installer already
compiled and thrown away.

The compile now ends in its own job, which uploads the unsigned artifact
and exposes its id. A second job downloads it, signs it, and does the
release-facing work, with the wait raised to an hour and the job timeout
sized to sit outside it. Separating them is what buys the recovery: the
artifact is uploaded before the wait begins and is addressed by id, so a
missed approval window costs a re-run of the second job alone rather
than a rebuild. Raising the timeout in place would not have given that.

The second job runs for unsigned builds too. Daily prereleases are
deliberately left unsigned to preserve the signing quota, and gating the
whole job on the signing decision would have meant a second copy of the
alias, artifact and release steps for them to run through.

The decision itself moves into a named step that echoes it, so a tag
that came out unsigned can be explained from the run log rather than by
re-reading the expression. It is one source of truth feeding both jobs,
which a job-level env could not be.

Every step body is otherwise unchanged. The property worth keeping is
that none of the alias, upload and release-attach steps carry always(),
so GitHub skips all three when signing fails or times out and an
unsigned .exe cannot reach a release; that is now written next to them,
because it is easy to break by adding a condition without noticing.

The policy slug stays at test-signing and the signature check stays
lenient -- the test certificate is self-signed and reports UnknownError,
so requiring Valid would fail every run until the production certificate
is imported. Both are the cutover. The restructure behaves identically
under the test policy, the request simply completing at once instead of
waiting, so it can be proven green beforehand.
2026-08-23 11:19:33 +02:00
maziggy 1d011ecf60 Updated BACKERS 2026-08-23 10:59:41 +02:00
maziggy 7b181b84f0 Let a filled or foamed filament keep its own name (issue #2902)
The reduction that gave an AMS slot a material type read PLA-AERO,
PLA-GF, ASA-GF and PPS-GF as their base material, so a slot loaded with
foaming or glass-filled filament went out saying plain PLA or ASA. That
is worse than the bug it replaced. "PLA-AERO" matched nothing before,
which was useless but honest; "PLA" matches every PLA plate in the
queue, so the dispatcher would have sent one to filament that will not
print it -- and the contract the first fix claimed, that it could only
ever repair a slot, no longer held. @doncaruana caught PLA Aero on the
issue.

All four are values Bambuddy itself offers: filament_fields.json is the
material list the Profiles editor puts in a dropdown, and the reduction
table was assembled from the cloud filament names and the frontend
preset parser without ever being checked against it. It is checked now,
so the next type added to one and not the other fails a test rather than
a print. ASA-AERO joins them from the cloud catalogue (GFB02).

The table hyphenates because the slicers do, while a spool says "PLA
Aero" and every Bambu preset name says "Bambu PLA Aero". Adjacent words
are joined and taken when the join is a type exactly -- exactly, because
letting the prefix and suffix rules reach across a space would make
"Support for PLA" a type by its tail.

Also from @doncaruana, and the better half of his point: a preset is
chosen from a list the slicer defines, so it already knows its own type
and nothing has to be read out of a product name. The resolver now hands
that answer back and both assign routes prefer it. It cannot be the only
source -- material is required on a spool and slicer_filament is not, and
the spool this issue was reported for had no preset at all -- so the
reduction stays as the fallback for spools without one.

Two things had to move with it. The auto-unlink guard compared the
slot's reported type against the reduced material, so a spool whose
preset outranked its material column would have been unlinked from the
slot it had just been assigned to; it now accepts any type the assign
path could have written. And two lookups keyed by material took the
catch-all for a type they had no row for, which sent an ASA-GF spool out
at 200/240 -- too cold to extrude -- and preheated its chamber to
nothing. Both fall back to the base material last, so PLA-CF, PETG-CF
and PA-CF keep the rows they are listed with, and ASA-CF and ABS-GF pick
up ranges they had been missing all along.

What counts as a material name is decided by the base for the same
reason: saying yes throws the value away and rescues the slot from the
generic-material fallback, so the answer has to be no when that fallback
has nothing to offer. ABS-GF reduces to a generic ABS the printer can
resolve; PPS-CF reduces to nothing and is left as it stands. Adding a
type to the table therefore cannot quietly change that answer, which is
how these five slipped through in the first place.

------

Hand the bundled chamber-preheat table back the way it is read

Every lookup of the per-filament chamber map happens after the keys are
upper-cased, and the parser documents exactly that: keys uppercased,
DEFAULT always present so the resolution loop can index it
unconditionally. The three fallback paths returned the bundled constant
as declared, with the lowercase "default" row the Settings editor writes
and displays, so an install that had never opened the setting got a dict
the loop could not read its fallback out of and used a hardcoded 0 for
any filament without a row of its own.

It reported the right number only because that bundled default is 0.
Raising it would have changed nothing for everyone who had not
customised the map, with the map in Settings still showing the value
that was not being used.

The test that should have caught this asserted the fallback under either
spelling, and its docstring contradicted itself between title and
comment. It pins the contract now, over all four ways the parser can
fall back.
2026-08-23 10:36:50 +02:00
maziggy 0f3063aa1a Point the Watchtower recommendation at the maintained fork (issue #2917) 2026-08-23 08:55:07 +02:00
maziggy 20bf108e55 Updated BACKERS 2026-08-22 14:25:53 +02:00
Maksim Sadontsev ed85677913 Light the generated thumbnails so one model differs from another (#2816) (#2861) 2026-08-22 14:16:56 +02:00
maziggy 68140747f2 Post work PR #2853 2026-08-22 13:43:05 +02:00
Sean K 55cc64c87d Add printer video downloads and range selection (#2853) 2026-08-22 13:22:56 +02:00
sgiffhorn 937440f956 Report the selected plate on the archives API (#2796) (#2871) 2026-08-22 12:44:47 +02:00
maziggy 4e40a5022c Register a Spoolman extra field with its own write (issue #2903)
Spoolman rejects a spool whose extra dict carries a key it has not been
told about, answering 400 "Unknown extra field tag.". Bambuddy keeps the
tray UUID in extra.tag, so that key has to exist before the first spool
is created. Registration ran from three hand-maintained lists that fire
when the integration is set up -- the connect route, startup, and two
inline blocks in the inventory routes. Enabling Spoolman from the
Settings page reaches none of them, so the first AMS sync on a fresh
Spoolman failed on every slot while vendor and filament creation
succeeded.

Neither fix suggested on the issue is quite the right shape. Adding the
block to PUT /settings/spoolman fixes this path and makes a third copy
of a list that has already drifted -- it would still omit
bambu_color_name. Ensuring at the sync entry point leaves the other four
tag writers alone: linking and unlinking a tag, and both inventory edit
paths.

So the registration moved to the write. create_spool, update_spool and
update_spool_full each register the keys of the extra dict they are
about to send, once per client, before sending. Every tag writer funnels
through one of the three, merge_spool_extra included. This closes the
class rather than the instance: a write that carries a key is a write
that registers it, and bambu_color_name shows why that matters -- it
never made it into the connect or startup lists at all, and works today
only because two call sites remembered it by hand.

Best-effort, deliberately. ensure_extra_field already logs and returns
False rather than raising, so a registration that fails leaves the write
to be attempted and to report exactly what it reported before. Failures
are not memoised either, so a Spoolman that was merely restarting gets
another try on the next write.

The older blocks stay. They are redundant now, but the inventory routes'
inline calls are pinned by tests that assert them against a mocked
client, where the funnel cannot run.

The status endpoint is the other half. The Connect button would have
registered the fields, and the reason nobody reaches it is that
GET /spoolman/status reported "connected" whenever an earlier request
had left a client object behind. Roughly twenty call sites build one
lazily, and saving the Settings page builds one as a side effect of
syncing locations, so the flag turned on which page had been opened
rather than on anything about Spoolman. The UI reads it twice -- Connect
only while disconnected, the sync section only while connected -- so
those two controls landed in states the user cannot explain. It now asks
the Spoolman that is configured, including the stale-URL check every
other route already does, and does not probe at all when the integration
is switched off, which used to let a leftover client report a disabled
Spoolman as connected.

That leaves nothing for Disconnect to do, so it is gone. Spoolman is a
stateless HTTP API with no session to close; the button dropped the
client object, the next request rebuilt it lazily, and the status
flipped back on its own within the 30s poll -- an action that looked
like it worked and then quietly undid itself. The enable toggle owns
turning the integration off. Connect stays as what it always was in
practice, a way to re-check a Spoolman that is not answering, and is
shown only then. Its translation keys are left in place; only the
control is removed.

Resolving the client there means the status poll can now fail in ways a
read-only check could not, so it no longer reports failure by failing.
Replacing a client closes the previous one and httpx's aclose() is not
guaranteed not to raise; a poll that runs every 30 seconds answering 500
is worse than one answering what is true either way, which is that
Spoolman could not be reached. The SSRF rejection keeps its own message
rather than folding into the general one -- a URL the guard refuses is
the admin's to correct, and that is only actionable if the log says so.

Tests drive the real client against a fake Spoolman that enforces the
unknown-extra-field rule rather than mocking it away, so each one fails
against the old code for the reason the reporter's install did. The
concurrency test needed the fake to be async: MockTransport answers
without suspending, so the first version ran each request to completion
in turn and passed just as happily with the lock removed.
2026-08-22 12:26:18 +02:00
maziggy 88e8ca81c3 Give an AMS slot a material type, not a product name (issue #2902)
Assigning a spool wrote its material straight into the slot's tray_type.
A slot that says "PLA+" satisfies nothing that asks for PLA: not
OrcaSlicer, not Bambu Studio, and not Bambuddy's own dispatch matcher,
which compares the type the printer reports to the one the 3MF declares
as plain equality. The reporter's slot was unusable for every PLA plate
he had.

Not only a label, either. The same string went into the generic-filament
lookup, which missed, so the slot went out with no tray_info_idx at all
-- the half-configured state #2604 documents the printer as reverting
from -- and took the 200/240 catch-all nozzle range instead of PLA's
190/230.

PLA+ is not a special case. Bambuddy's own colour catalogue supplies the
material dropdown, and around forty of its values are vendor product
lines rather than filament types: HTPLA, PolyTerra PLA, PLA Matte, ASA
Extrafill, Flexfill TPU 98A.

So the four routes that configure a slot reduce the material to a name
the printer knows before sending it, and the product name moves to
tray_sub_brands -- which is where Bambu Lab puts it too: their catalogue
carries a preset named "eSUN PLA+" whose type is PLA. A name the
reduction cannot place is sent exactly as before rather than guessed at,
so this can only repair a slot, never break a working one. The spool's
own wording still leads the id and temperature lookups with the reduced
type appended behind it, so "PETG HF" keeps its own generic preset
(GFG96) rather than being traded down to plain PETG's.

Two guards decide whether a candidate filament id is really a material
name -- the resolver's, which discards one, and slot reuse, which will
not carry one forward. Both saw only bare types, so "PLA+" passed as a
filament id. They share one answer now, which also refuses to read an
id-shaped value: "GFPLA" ends in a material name, and reducing it would
throw away the calibrated preset in the slot.

One thing had to move with it. on_ams_change auto-unlinks an assignment
whose slot stopped looking the way it did when the spool was assigned,
and the check that spares a slot Bambuddy itself reconfigured compared
the printer's reported type against the spool's raw material. With the
slot now carrying the reduced type, every spool this issue is about
would have been unlinked from the slot it had just been assigned to.
Both sides are reduced there -- the printer's too, so slots configured
by an older version, still reporting "PLA+", keep matching.

Something starts working as a result: a slot holding a calibrated preset
is reused when a same-material spool is assigned to it, which could not
happen for these spools while "PLA" and "PLA+" compared unequal.

Reverting any one of the behaviours above fails a distinct test -- the
reduction's four matching rules and its pass-through contract included,
since that contract is what makes the rest of it safe.
2026-08-22 11:41:28 +02:00
maziggy cc39acfc74 Ask a printer that refuses FTPS what it actually said (issue #2780)
@grolmus measured a 9-printer farm and the numbers settle what this
failure is not. Reproduced here, three results:

  cleartext "421" banner on the TLS port
    -> [SSL: WRONG_VERSION_NUMBER] wrong version number (_ssl.c:1032)
  1.2-only server, client forced to 1.3
    -> [SSL: TLSV1_ALERT_PROTOCOL_VERSION]
  1.2-only server, an uncapped client
    -> negotiates 1.2 and connects

The first is byte-for-byte what the farm logs. So WRONG_VERSION_NUMBER
means the printer's first bytes were not a TLS record, a version
mismatch cannot produce it, and reaching a 1.2-only peer needs no cap.

What it still does not say is WHICH cleartext message, and that is the
part that would name the fault. OpenSSL has eaten those bytes by the
time the exception surfaces, so on this error the client now opens one
plain connection and reads them. The log then carries the printer's own
words -- an FTP refusal such as "421 Too many connections" would settle
it outright -- marked as the line to quote in a report. This gets the
answer from every affected install rather than from the one farm able
to take a packet capture.

Three things keep it from making the suspected fault worse:

- The failed socket is closed BEFORE the probe opens its connection.
  Holding a dead handshake open across a second connect to a printer
  that may be out of connection slots is the leak #2780's own cleanup
  was added to stop.
- It asks once per cool-off window, not once per attempt. Checked
  before the new deadline is written, so a live entry means an earlier
  failure already asked -- which matters because a dispatch ignores the
  cool-off (#2898) and reaches this branch four times.
- Connect and read share one timeout budget rather than getting one
  each.

Only WRONG_VERSION_NUMBER is probed. A protocol-version alert means the
peer did speak TLS, so there is nothing in the clear to read and the
probe would only sit out its timeout. A vsFTPd answering its connection
limit by accepting and staying silent -- the other half of the standing
theory -- arrives as a handshake timeout and lands on that branch
instead; there is a test saying so, because widening the trigger later
would look like an improvement.

The profile registry is corrected to what was measured. Its docstring
claimed "the P2S evidently does offer 1.3"; six P2S units refuse it.
Worse, the X2D (#1638) and H2C (#2582) entries were capped on the
reading that WRONG_VERSION_NUMBER came from a TLS-1.3 ClientHello,
which cannot happen -- so the cap is not what changed those outcomes
and both are now marked RE-TEST WANTED. They are kept rather than
removed: their reporters saw the symptom clear, nobody here has that
hardware, and the entry costs nothing on a printer that does not offer
1.3 anyway. The P2S entry (#1401) is a different symptom -- a 426
truncation mid-transfer -- and is the only one a session-ticket problem
could explain, though grolmus's firmware refuses 1.3 there too.

Both measurements are pinned by tests, so the explanation stays
falsifiable instead of becoming the next set of confident wrong
comments. Two existing cool-off tests now count two connections where
they counted one; the promise they exist for -- contacted twice, not
~110 -- is unchanged, and they say why rather than carrying a new
number.
2026-08-22 10:50:22 +02:00
maziggy 70ee53464d Say why an upload failed instead of blaming the SD card (issue #2899)
Every dispatch upload that failed carried one sentence: "Failed to
upload file to printer. Check if SD card is inserted and properly
formatted (FAT32/exFAT)." The reporter got it after a TLS handshake
failure and restarted the printer on the strength of it. That could not
have helped. The handshake never reached the printer's filesystem, and
the cool-off that made the next dispatch fail the same way lives in
Bambuddy's own memory, where power-cycling a printer does not reach.

because the advice was known not to work. It survived in the string
people actually read, so the failure mode that fix closed was still
reachable through the UI.
reachable through the UI.

The information was never missing. connect() separates five failure
classes and upload_file() separates 553/552/550, each with its own log
line -- 553 even logs a spelled-out list of storage causes -- and then
both returned a bare False. The dispatch had nothing left to work with
and guessed storage for all of them.

So the reason now travels with the result. The client records an
FtpFailure (kind, detail, and the reply code where the server gave one)
on every failure branch, and upload_file_async fills in a report object
the CALLER owns. Not a per-IP dict beside _mode_cache: those describe a
printer and are right to share, while this describes one operation, and
a background timelapse fetch running beside a dispatch would overwrite
the dispatch's reason with its own -- reporting the wrong cause with
total confidence, which is this bug again rather than a fix for it.

describe_upload_failure() picks the wording, and lives next to the kinds
so the two cannot drift. A 553 or 552 keeps the card advice, which is
the case it was written for, and quotes the reply code so a queue entry
and a support bundle line up. A handshake failure says the file service
answered without TLS and that the card is not involved. A refusal points
at the access code, a timeout at the network, and anything unclassified
says so and points at the log rather than picking a plausible cause. A
wrong instruction costs more than a vague one: it sends someone to work
on hardware that is fine. Nothing prescribes a power cycle.

The failure notification now carries the same sentence the queue shows,
instead of its own fixed "Failed to upload file to printer", so a push
and the screen cannot disagree about what happened.

Tests cover the classification, the report reaching the caller through
the retry loop, two callers not crossing, the queue entry itself, and
one line per message branch -- without that last one, deleting the
access-code or timeout branch left every other assertion passing, since
they only check that the card is not named and the generic message
satisfies that too. The card-advice test keys on the instruction rather
than the words "SD card", because the handshake message names the card
in order to rule it out.
2026-08-22 10:26:12 +02:00
maziggy 7c8f1f9435 Keep a dispatch's retries out of the FTPS cool-off (issue #2898)
A failed TLS handshake arms a 300s per-IP cool-off, and connect()
consulted it for every caller. A print dispatch retries after 2s, so
once the cool-off was armed all four attempts were answered from the
gate rather than the network, and every further job queued for that
printer failed the same way for the rest of the window. The reporter's
farm lost three jobs to one handshake error, with the retry budget
contributing nothing to any of them.

The gate was serving two callers that want opposite things from it. The
background sweeps -- the post-print 3MF, cover and timelapse fetches --
walk ~110 candidate paths against one wedged printer with nobody
waiting, and backing off for minutes is right for them. A dispatch is
one delete plus at most four upload attempts with someone watching a
progress bar. So the split is by caller: a client built with
respect_handshake_cooloff=False goes to the printer regardless, and the
dispatch's delete and upload -- and a firmware upload, same shape --
opt out. Everything else keeps #2780's behaviour untouched.

In the reported trace it is the pre-upload delete that takes the SSL
error and arms the cool-off, 8ms before the upload's first attempt, so
exempting the upload alone would have left one dispatch's worth of the
problem in place.

Callers that do respect the cool-off no longer sleep out a retry loop
against it: with_ftp_retry takes the printer's IP and stops at the
attempt that armed the gate, instead of spending three more attempts
and six seconds on connections that cannot happen. It also reports the
attempts it really made -- "failed after 4 attempts" for one attempt is
part of how this read as a network problem.

Two diagnosis fixes go with it. The cool-off skip was the one connect()
failure path that reported without naming its cause, and at DEBUG, so
four identical reason-free warnings were all the operator saw. It now
says at WARNING that nothing was sent and how long the printer has
left, once per cool-off rather than once per attempt -- not every
caller is gated, and a download-zip of 200 files would otherwise repeat
the sentence 200 times, which is the flood #2780 set out to stop.

And a dispatch that fails this way no longer tells anyone to check
whether the SD card is inserted and formatted -- nothing reached the
printer's filesystem, so the card is the one part of the machine that
was working. The message names the file service and rules the card out.
It is used only when a handshake failed during the dispatch itself,
read from the cool-off deadline MOVING rather than merely being armed:
the dispatch ignores the gate, so it can be running underneath one an
unrelated background fetch left behind, and blaming TLS for an upload
that really hit a full disk would repeat the mistake in the other
direction.

Tests count sockets rather than return values, since "returned False"
looks identical whether or not anything was attempted -- which is what
made the original report a log dive. Reverting any one of the five
behaviours above fails a distinct test.
2026-08-22 10:05:05 +02:00
maziggy e4aab7b44b Leave archived projects out of the pickers that file work (issue #2888)
The reporter opens a project per job and archives it when the job is
done, so the Project dropdown in Edit Archive listed five live projects
behind thirty-odd finished ones, in one unscrolled run with nothing to
tell them apart.

Archived is the state that means "put this away", so that is what the
pickers now drop: the Edit Archive dropdown, the pending-uploads panel,
the bulk Add to Project dialog and the File Manager's folder link.
Completed stays. It says the work is finished, not that it should be
hidden, and filing a reprint under a finished project is ordinary.

The Archives right-click submenu had the opposite bug and offered
active projects only, so a completed project was reachable from the
edit dialog and not from the menu next to it. All five surfaces share
one rule now.

Whatever a thing is already filed under survives the filter whatever
its status. A select holding a value that matches none of its options
is reset by the browser to the first one, and here that reads "No
project" -- an archive sitting in an archived project would have said
in as many words that it was filed nowhere. The stored id does survive
an untouched save; it is the field that lies.

The parent-project picker is deliberately untouched. A finished or
archived project is still a legal parent, and its own comment says so.

Fixed alongside it, and reported separately: the status tabs counted
only the projects the selected filter had already let through, so every
tab but the current one counted zero and dropped its badge. Switching
tabs moved the number rather than showing four of them. They are
counted from the unfiltered list the page already fetches for the
sub-project captions -- same query key, no extra request.

The new rule is one function with its own unit tests, since five
callers now depend on it reading the same way. Each half is pinned
separately: dropping the filter, dropping the kept id, restoring
active-only, and counting from the filtered list each fail their own
tests and nothing else.
2026-08-22 09:27:26 +02:00
maziggy 3916db822c Stop the G-code preview from sizing the box that sizes it (issue #2887)
Opening a 3D Preview from Archives left an empty white pane with the
legend and the layer slider drawn over it, and the page's scrollbar
shrank for as long as it stayed open -- about 190px of page height a
second, with no limit.

The viewer appends its canvas into the very element it measures with
clientWidth/clientHeight and watches with a ResizeObserver. setSize
writes each new size onto the canvas as inline style, and three.js
leaves the canvas display:inline, so the line box adds descender space
on top of the height just set. Where that element takes its height from
its contents, the canvas sizes the box that sizes the canvas and gains a
fixed 33px every round -- the reporter measured container = canvas + 33
on every sample.

The page gave it no height to take instead. The viewer pane is flex-1
min-h-0, which divides nothing unless the column above it is a definite
height, and h-full is a percentage resolved against a main area whose
own height comes from a min-height -- a floor, not a size. So it fell
through to the content, and the content was the canvas.

Nothing was ever drawn because of the same loop, not a second fault:
every observer callback reallocated and cleared the frame buffer, and an
antialiased render of what had grown to roughly 18 megapixels never
finished before the next one arrived. The data path was fine throughout,
which the legend and the 1..57 layer slider both prove -- they are built
from the parsed toolpath.

The canvas is now positioned out of flow, so it cannot contribute to the
height of the element that measures it on any page, and that element
takes a definite height from the pane around it rather than a
percentage. display:block goes on too, for the case where something
overrides the positioning. The page is sized from the viewport the way
the File Manager page already was.

Either change alone stops the growth, but the structural one alone would
trade it for a collapsed pane: an out-of-flow canvas contributes nothing
to content height, so with no definite height above it the pane becomes
clientHeight || 1. They belong together.

The same viewer in the File Manager dialog was never affected -- a
dialog gives it a fixed height, so neither fault could arise there.

jsdom does no layout, so the loop cannot be reproduced in a test. The
structure that forbids it can: the new cases assert the canvas is out of
flow, that the measured element is definite-height rather than h-full,
and that the pane stays positioned so inset-0 resolves against it.
Reverting either change fails exactly those.
2026-08-22 09:05:12 +02:00
maziggy 4961990a7a Let a print start on a nozzle the printer can fetch (issue #2885)
The nozzle-diameter guard compared the sliced diameter against the
mounted hotends alone. On an H2C both hotends commonly read the same
size, so a job sliced for anything else was failed before upload with
"install the matching nozzle before printing" -- even with that nozzle
sitting in the tool-changer rack, which the printer fetches by itself
as part of starting a print. The reporter saw it as an asymmetry:
going to 0.4mm always worked, going to 0.2mm never did, and only
fetching the nozzle by hand on the printer's own screen let the print
run. It was never only about 0.2mm -- with a 0.6mm docked and 0.4mm
hotends, a 0.6mm slice was refused identically.

Placement is what made it fatal rather than merely wrong. The guard
runs near the top of _start_print and the rack picker near the bottom,
so the item was failed before the code that would have chosen the dock
ever ran.

Bambuddy had the rack contents the whole time. nozzle_info carries an
entry per nozzle -- ids 0/1 for the hotends, 16-21 for the docks --
each with its diameter, so the guard now tests the slice against both
sets. It keys off the ids rather than the printer model: only a rack
machine reports 16-21, which leaves no registry to keep in sync. An
empty dock is absent from the payload entirely, so an id appearing
there already means a nozzle is in it. stat is left uninterpreted; it
read 0 on every entry, occupied and empty alike.

A diameter in neither a hotend nor a dock still stops the print before
it uploads, and the message now names both sets so the machine's real
stock is visible.

The same telemetry showed a second fault, pointing the other way. A
hotend with nothing mounted is still reported, keeping the diameter of
the nozzle it last held -- measured at idle, where the rack-side hotend
read 0.4mm with max_temp 0 and serial "N/A" after parking its nozzle
back in the dock. That stale value counted as installed. Presence now
comes from the serial and the temperature rating, and emptiness has to
be stated rather than merely unstated: the serial must be the
firmware's explicit "N/A" and the rating absent. A firmware that
reports neither field normalises to exactly that, and reading it as
empty would switch the guard off on that machine.

Confirmed on an H2C with 0.4mm hotends and a 0.2mm in R6: the job
dispatches with nozzle_mapping [21], chosen by Bambuddy rather than
left to the firmware.
2026-08-22 08:46:07 +02:00