mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-09-30 03:01:21 +02:00
1a84dfea5b480595cc8d75a730153a00a784404b
4271
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
1a84dfea5b |
feat(print-modal): show each printer slot's colour in the filament mapping (issue #3159)
The Print / Schedule dialog's filament mapping is where the colour a slice asked for is compared against the colour actually loaded, and only the left-hand side of that comparison had a swatch. The slot, and every slot in its dropdown, was text -- and the text cannot be trusted: a slot's colour name is resolved from the Color Catalog or, failing that, from hue, so a third-party beige is announced as "Orange". A "Color mismatch" warning then gives no way to tell a real mismatch from two names for the same hex without opening the printer card in another tab, which on a farm swapping twenty or thirty non-Bambu colours between machines is a check made many times a day. Each slot now carries its colour and its hex, and the slot whose colour is exactly the one the slice asked for is ticked. This works for a slot bound to an inventory spool and for one configured through Configure Slot or on the printer itself: the second kind has no inventory row behind it, and the printer's own tray colour is then what draws. A bound spool contributes what a tray record cannot -- SlotSpoolIdentity gains extra_colors and effect_type, so a two-tone or glittery spool draws as itself rather than as its base colour. The same treatment goes to the filament-override picker used for model-based assignment. It is the same choice on the other dispatch path, and leaving it text-only would have made one decision read two ways. Both controls stop being <select>s to do it, because an <option> renders text and nothing else. SlotPicker keeps what the select gave for free -- arrow, Home/End, Enter and Escape keys, listbox semantics, and the border colouring that encodes match, same-type-different-colour and not-loaded -- and is portaled with position:fixed so it is not clipped by the dialog's own scroll container, flipping above the row when there is no room below. |
||
|
|
64817ecc18 | Post work PR #3062 | ||
|
|
6c1006ca54 | Feat: add Swedish language (#3062) | ||
|
|
6e8d543d2a |
fix(ams): stop showing the humidity drop index as a percentage (issue #3140)
Bambu sends two humidity fields that are not the same quantity. humidity_raw is relative humidity in percent; humidity is a 1-5 drop index, and it runs the other way -- OpenBambuAPI's push_info sample pairs "humidity:30%" with "humidity_idx:4", so a high index means dry where a high percentage means wet. Four call sites used the index whenever no percentage arrived. A unit sending only the index therefore rendered as "2%" in the green band while being the second-wettest of the five steps, charted an average of index values as a percentage, and sat under every humidity threshold forever, since no index can reach one -- the alarm and auto-drying could not fire for such a unit at all. - utils/ams_humidity: one leaf helper, a percentage or None. The index is never converted; None is what every caller already handles. - routes/printers, printer_manager, print_scheduler, main, bambu_mqtt: all five readings go through it, so the card, the websocket, the chart, the alarm and auto-drying cannot answer differently. - main: a unit that reports the index and no usable percentage says so once per unit in the log, with its firmware versions requested. No supported printer is known to do this, and "known" is doing work there -- the alternative is a card that goes blank with no trace. Three faults found while checking what else those paths touched: - main: humidity_raw=float(x) if x else None stored NULL for a numeric 0% while writing 0.0 to humidity on the same row. - main: that same expression was unguarded, unlike the parse above it, so a non-numeric humidity_raw raised inside record_ams_history and aborted the pass for every printer, not just the one that sent it. - routes/ams_history: the averages were tested for truthiness, so a window averaging exactly 0 reported no average while the min and max beside it reported 0.0. An affected unit now reports no humidity rather than a number that means the opposite: the indicator is hidden, the chart leaves a gap, the alarm and auto-drying skip the unit. Temperature is untouched. Auto-drying's outcome is unchanged either way -- an index could never cross the threshold -- so only the intent moves. No supported printer is known to be affected; the report came from an install running X1Plus, which Bambuddy does not support. Verified against 7927 recorded samples from seven AMS units including an AMS-HT: not one used the fallback. Two percentages that did fall through to the index no longer do -- a reading with a decimal point, and "38.0", which int() rejected. |
||
|
|
08b4ae992f | Updated BACKERS | ||
|
|
fc6b953816 |
fix(virtual-printer): give each install's CA a name of its own (issue #3014)
A slicer holding the CA of two Bambuddy installs could only connect to one of them. Each CA worked on its own; together, one stopped, with the generic "Connect ... failed! [SN:..., code=-1]" that an install whose CA was never imported gives. Every install signed as exactly CN=Virtual Printer CA. A slicer's trust store is a flat list of certificates and OpenSSL resolves an issuer by Subject DN: it takes the first authority whose name matches and fails the chain when that one turns out not to have signed the certificate, rather than trying the next match. Whichever CA landed second in the file lost -- decided by nothing but the order they were appended in. Reproduced with openssl verify against a bundle holding two CAs: the first leaf verifies, the second fails with "certificate signature failure". - certificate.py: a newly generated CA takes a suffix from its own key identifier (CN=Virtual Printer CA D55808BE) and publishes that identifier, which the printer certificate points back at. - Existing CAs are untouched, so nothing has to be re-imported. A printer certificate signed by one keeps exactly the shape it has today: the authority key identifier is added only when the CA has an identifier to name. - tests: unique names per install, the identifier reaching the leaf, an existing CA being reused unchanged, and both chains verifying through openssl from a single trust store. The collision goes away as soon as one of the two CAs is newer than this change. Two installs that both predate it still collide until one has its bbl_ca.crt/.key deleted and regenerated, which is a re-import for that one -- documented in the wiki. Reported by @Steven-Pierce. |
||
|
|
1b20d1a968 |
fix(notifications): send the ntfy priority the dialog was collecting (issue #3139)
The per-event Priority header from #990 never reached ntfy. The dialog builds its rows from the provider's event toggles and stores the map under those names -- on_print_complete, on_print_failed -- while every sender is called with the bare event name, print_complete. The lookup missed for all 18 events the dialog offers, so every notification went out at the ntfy server's default with the configured priority sitting untouched in the database. Both ends looked healthy, which is why it shipped. The stored config held exactly what was set, and the tests were green because they called _send_ntfy directly with the prefixed name -- the one spelling the running system never produces. - notification_service.py: accept either spelling, bare first, so existing configs keep working and nothing needs migrating. - schemas/notification.py: document both key forms, and which one the UI writes. - tests: use the bare names, and add one that runs from a finished print through to the outgoing request. Without the fix it fails on a header dict holding only Title, which is the assertion that was missing. The daily digest is unchanged: send_digest sends with no event_type at all, and the dialog offers no priority for it -- it is one message for several events. |
||
|
|
58ea7a360d |
refactor(models): break the schema cycle that backup and restore sort through
print_archives.library_file_id -> library_files.folder_id -> library_folders.archive_id -> print_archives. Three nullable SET NULL links, each reasonable alone, that together made a loop metadata.sorted_tables could not sort: it dropped those edges, warned on every backup and every restore, and could return an order placing a child before its parent -- which once imported library_files ahead of library_folders and killed a restore on a ForeignKeyViolation. The restore no longer depends on that order (it strips every foreign key before importing and adds them back after), but the backup export sorts the same way, and the warning ends with "may raise an error in a future release" -- which would break backup and restore on one upgrade. Marking one edge use_alter removes it from the sort graph, not from the database: PostgreSQL emits it as ALTER TABLE ADD CONSTRAINT, as it already did for every constraint on these three tables, and SQLite inlines it into CREATE TABLE, so ON DELETE SET NULL holds on both. Verified against PostgreSQL 16 and SQLite. |
||
|
|
0eb083b32e |
fix(slicer): read the plate model once per part for the post-slice thumbnail (issue #3135)
The post-slice thumbnail loaded the sliced 3MF with trimesh, whose reader mishandles the Bambu Studio / OrcaSlicer layout: for every component that references a file in 3D/Objects/ it re-parses that file and appends all of its meshes again. N copies of a part came back as N^2 copies of its triangles, and each component carried every other part of the same file. 25 bins of 10k faces loaded as 6.4M faces; the render took 54 s and 8.4 GB on the event loop, and the server was OOM-killed. Parse the 3MF directly (lxml, entities/DTD/network off, streamed and freed element by element), walk objects, components and build items (p:path on either) with their transforms, and keep each mesh once. Decimate per unique mesh to its share of a face budget before placing instances, flip winding on mirrored placements, and skip the thumbnail above a face ceiling checked both on what decimation can reach and on what it delivered. Both slice routes run the render in a thread. The renderer uses matplotlib's Figure/Agg API instead of pyplot, whose process-global figure state let a threaded plate render and stl_thumbnail's event-loop render lay out and close each other's figures. |
||
|
|
89d94796ee |
fix(queue): keep the filament override when a model job moves to one printer (issue #3133)
Switching an "Any P2S" job to a specific P2S cleared its filament override: "Specific Printer" empties the target model and the reset effect counted that as a model change. Printer mode also matched trays against the 3MF's colours, never sent the override, and left the old one on the row. The reset now compares against the last model actually targeted, so the switch keeps the override while a real model or plate change still clears it. Printer-mode tray matching (single, per-plate, multi-printer and the selector's per-printer editor) runs against the requirements with the overrides applied, mirroring the scheduler's _apply_filament_overrides; an entry naming the slot's own filament is not a swap and keeps its tray_info_idx. Printer-mode submits carry the user's overrides, and the create endpoint stores them for a printer-targeted job, so a dispatch-time recompute of an unresolved mapping looks for the same filament. Saving re-attaches the tray_info_idx an unchanged entry already had, so a virtual printer's force-colour PLA-variant pin (#2650) survives an edit in either assignment mode. The printer card's compatibility filter skips printer-targeted jobs: it mirrors the model scheduler, and hiding a job on filament would hide it from the printer it is going to run on. |
||
|
|
f98381f3d1 |
fix(queue): send the copy count for a cross-model print (issue #3101)
Selecting sliced files for two printer models and asking for 25 copies queued one item. The queue emptied as soon as it dispatched and the Batches tab stayed empty, because no batch is created at quantity 1. A multi-plate file moves the run count off the modal's Quantity field onto a stepper beside each plate (#342), hiding the field. The cross-model submit (#671) posts that field, which in this combination nothing can set, so it stayed at its initial 1. The modal read "19 runs in total" above a button that queued one. Per-plate steppers do not fit a cross-model job: its plate is chosen per candidate, in the alternatives list, so there is one number to give. Exclude cross-model from the per-plate mode and the global field comes back. Drop the plate selector in that mode too. Its choice never reached the request; it only keyed the filament-requirements query, so picking plate 3 for a candidate while plate 1 stayed ticked above produced overrides computed from a plate the job would not print. That query now follows the primary file's own dropdown. Dispatch needed nothing -- it already gives each copy its own candidate rows -- but naming did. A cross-model job carries neither archive_id nor library_file_id, because the candidates are the files, so both branches that name a batch missed and every such order would have read "Batch" in the tab the reporter went looking in. Name it after the first candidate. The existing cross-model tests all mock a single-plate file, which is why the pair was never covered; the multi-plate case is added. |
||
|
|
ebc72e1d41 |
fix(archives): keep the project name when the wrong-plate guard rejects a 3MF (issue #3126)
Bambu Studio files a sliced print on the X2D's internal eMMC, which FTPS does not serve. The bounded probe found a same-named file on the card -- an earlier slice of the same project, plate 4, against a running plate 1 -- and #1204's guard correctly refused it rather than archive another plate's thumbnail, filament and cost. It then blanked subtask_name because swap_plate_suffix returned None. But None also means "this name carries no plate suffix", and such a name holds no stale plate number to be wrong about. The project name was dropped, the row fell through to the gcode_file path, and the archive was titled plate_1. Keep the name for the title only. subtask_name itself stays disowned, because it is what every lookup here is built from and it keys _active_prints, where the cover endpoint's own download of that same name would find this archive and hand the contradicted file to _recover_fallback_archive -- which checks a candidate is a readable 3MF and never which plate it holds. A corrected name is still registered: that one points at the plate actually running. Also name the X2D alongside H2-series and P2S in the Archives banner, the connection diagnostic and the storage-verdict docs -- it stores slicer sends the same way, and an X2D owner was told the explanation did not apply. |
||
|
|
8f9d79ccf0 | Post work PR #? | ||
|
|
036f0a688f |
Merge pull request #2845 from pascalheidmann/refactor/modular-import
(Refactor): modularize import ("Makerworld tab")
|
||
|
|
0db028f9e6 |
fix(inventory): one structured 409 for a tag another spool holds (issue #3110)
The two tag-link routes answered the same conflict differently. The
built-in one said "Tag UID already linked to another active spool" and
named nobody -- while holding the conflicting spool row it had just
loaded -- and Spoolman mode named the spool inside a different English
sentence. Neither was machine-readable, so a client had to parse prose
to learn which spool to look at, and could only do it in one mode.
Both now raise one shared constructor: code tag_already_linked, the
holder's id, and which identifier collided. That is the detail shape
insufficient_filament and printer_connection_failed already use, so
ApiError parses it with no frontend change.
Two active spools can carry one tag -- no unique index on either
column, no conflict check on PATCH /spools/{id}, and /spools/bulk
copies one payload including the tag into every row it creates -- and
the lookup read that with scalar_one_or_none(), which raises on two
rows. The exception escaped into the auth middleware's fail-closed
handler, so the caller was told the authentication service was
unavailable. Both lookups are now ordered and take the first row, as
get_spool_by_tag earlier in the same file always has.
Naming the lowest id means the Spoolman scan reads every row where it
used to stop at its first match, so it now reads extra.tag defensively:
that field is edited outside Bambuddy, and a single null further down
the list would otherwise take the request down in place of the 409.
The kiosk reads the new code: a refused link showed a flat "Failed to
assign spool" and now names the spool holding the tag, reusing the
inventory.tagAlreadyLinked key that no code referenced.
|
||
|
|
885c4156ae |
fix(inventory): enable Clear RFID Tag for a tray-UUID-only spool (issue #3109)
The button gated on tag_uid alone. A spool linked by its 32-character Bambu tray UUID carries none -- Bambuddy splits a stored tag by length, so a 32-char value becomes tray_uuid and tag_uid stays empty. In Spoolman mode that is every Bambu Lab spool synced from the AMS; on the reporter's instance, 35 of 39 tagged spools, none of which could have its tag cleared from the dialog. The documented workaround was to edit extra.tag in Spoolman's own interface. Everything around the button already treated those spools as tagged. The Tag ID column renders whichever identifier is present, and the payload the button sends nulls both fields -- which both inventory modes honour: the built-in PATCH applies them through exclude_unset, and the Spoolman route keys its tag-removal branch off either field being explicitly null. Either identifier now enables it, and clearing still removes both. |
||
|
|
905bda4f3f |
fix(ams): read the firmware presence bit, not the tray state (issue #3084)
Swapping a Bambu spool for one the AMS cannot read left Assign Spool publishing no ams_filament_setting at all. The printer kept showing "?" on its screen and in the slicer, and only Configure, which publishes unconditionally, put anything there. Four places asked the tray's `state` field whether a spool was in the slot. It cannot answer that. An AMS-HT reports its LOADED tray as 9 rather than 11, because it does not feed into a shared buffer the way a 4-slot AMS does -- the merge has skipped its own state heuristic for HT units since #2594 for exactly this reason. And the field is partly our own writing: apply_tray_exist_bits stamps state=9 on every slot whose tray_exist_bits bit is 0, and when the bit comes back it refreshes only the `exists` annotation beside it. Either way the slot sits at exists=True, state=9 until something configures it. That 9 also kept the deferred-configuration replay from firing -- its own "has a spool appeared" test was the same heuristic -- which is the deadlock #1322 removed from the assign path, still in place one step further along. And it is what deleted the assignments in #3100: with the replay never firing, the row kept the empty fingerprint it was stored with, and the first tray report naming a filament was read as a swap. All four now read tray_exist_bits first, which is the mask firmware answers this question with and the one the printer card has drawn its "?" from since #2527. The bit is allowed to overrule an "empty" state and nothing else: a bit reading empty deliberately does not start suppressing pushes that go out today, because the cost of computing a bit position wrong is a slot that silently stops configuring, against a saving of one message firmware would have dropped. A blank tray report from a slot the bit calls occupied no longer unlinks anything, off a print as well as during one, in both inventory modes -- Spoolman's parse_ams_tray calls a tray with no type empty, so a tag-less spool assigned through the UI had its row deleted by the first idle push after it went in. A filament the AMS cannot identify is not a filament that was removed. |
||
|
|
4a85e033c0 |
fix(finance): show the currency the install is configured for (issue #3123)
The Finance page was the only surface in Bambuddy that read its currency from a data row rather than the `currency` setting, and it fell back to EUR where every other page falls back to USD. One variable drives every amount on that page, so the personal balance, the cost-center budgets and the whole transaction list were wrong together on any install not set to euros. It now takes the configured currency from /settings/ui-flags, which is readable by anyone who can see Finance -- /settings needs SETTINGS_READ, which a cost_centers:read_own user does not have. The backend was the other half. Of the four places that settle on a currency, three wrote a hardcoded "EUR": the wallet the API mints on demand, the wallet a print charge mints when none exists, and the balance returned for a user with no wallet row at all. All four now go through one resolver, which lives beside the rest of the balance logic. The wallet's currency column is removed outright rather than merely ignored. An install has one currency and nothing here converts between them, so a per-wallet copy could only ever drift from the setting -- and a column nothing reads is a trap for whoever finds it next. A startup migration drops it on both SQLite and PostgreSQL, after the raw CREATE TABLE that would otherwise re-add it on an install whose finance tables predate the ORM. SQLite builds older than 3.35 have no DROP COLUMN and keep it, harmlessly, since it has a default and no reader. Saving settings now invalidates the ui-flags query too. Nothing did, so a changed currency sat behind that query's staleTime before showing up. The sponsor prompt's own EUR fallback is now USD, matching AppSettings. |
||
|
|
74173eab8d |
fix(vp): offer every host IP as a bind target, not one per adapter (issue #3121)
Each enabled virtual printer needs its own IP address, and the documented way to get several is to add secondary addresses to the adapter already in use. Linux reads those back through `ip -j addr show`, which reports every address. Windows and macOS have no `ip` command and fell through to a psutil enumeration that stopped at the first IPv4 of each adapter, so a host with three addresses on one NIC offered exactly one bind target and the second virtual printer could only fail with "Bind IP ... is already in use". The psutil path now collects every address, marking the ones after an adapter's first as aliases the way the iproute2 path does. Callers that want interfaces rather than addresses -- the discovery scan and the support bundle -- project the primaries back out, so their view is unchanged. The ioctl fallback that a Linux host without iproute2 used to get is now reached only when psutil itself is missing, which gains that host aliases too. The interface-name exclusions stay Linux-only: they are Linux device names, and a Windows adapter called "Local Area Connection" matches the "lo" prefix. |
||
|
|
1ccaf74dd5 |
fix(install): sign the Python that macOS grants local network access to (issue #3114)
macOS attributes Local Network permission to a code signature and judges a launchd-spawned process on its own, rather than letting it inherit the grant of the Terminal that started it. Homebrew ships Python unsigned on Intel, so there is no identity for the grant to attach to: every connection to a LAN address is dropped with no error the application can log and no permission prompt. The printer reads as unreachable and nothing says why, and the entry in Privacy & Security cannot be made to work because it refers to an identity that no longer resolves. install.sh signs during a macOS install; update_macos.sh re-checks on every update, because `brew upgrade python` installs a fresh unsigned binary under a new versioned path. Both sign only what is currently unsigned. That gate is load-bearing: on arm64 the linker ad-hoc signs every binary and the identity is a hash of the file, so re-signing would rotate it and revoke a working grant on each update. A python.org build carries a real Developer ID and must not be downgraded for the same reason. The interpreter and the framework's Python.app are both signed. The first is what sys._base_executable resolves to and what the reporter's TCC log names; the second is what his fix actually targeted. Which one macOS attributes could not be established from either, and signing both costs nothing. ----- fix(diagnostics): name the macOS permission that silently blocks the printer (issue #3114) The port checks reported all three ports unreachable while the subnet check passed, and port_mqtt's fix text sent the reporter after firewalls and IP addresses. On a macOS native install that pattern has a cause neither of those covers: no Local Network grant, denied with no error and no prompt. A new macos_local_network check, appended on macOS only so no permanently dimmed row appears for anyone else. It passes when the control port answered, which is proof the permission is in place and means the signature probe never runs on a healthy diagnostic. Otherwise it probes the interpreter: an unsigned one gets the repair that fixes it, a signed one gets System Settings — the arm64 case, where the identity is a hash of the binary, so a Python upgrade presents macOS with a new application and strands the old grant. Always warn, never fail, and only once port_mqtt has already failed, so this can never be why a green diagnostic turns red. A printer that is simply switched off produces the same all-ports-dead pattern, which is why the signature, not the pattern, is what earns the specific advice. An undeterminable signature is reported as the generic case rather than as unsigned: that advice rewrites a file in the user's Python installation and must not be offered on a guess. |
||
|
|
70b42d1c8d |
fix(library): stop reporting success for a bulk add that queued nothing (issue #3112)
POST /library/files/add-to-queue reported every per-file rejection in an errors array and returned 200 regardless. A caller that checks the status code saw a successful request, no visible failure, and no queue item. That is a 400 now when nothing at all was added, with the same reasons in the body. A call that created some items still succeeds, because it did. The items it created were aimed at nothing. The route always wrote printer_id=None with no target_model, and the scheduler dispatches on one or the other -- so those rows matched neither branch and could never be picked up by anything. They sat in Unassigned until someone opened each one by hand. The request takes an optional printer_id or target_model for the batch, and with neither it aims each file at the model its own G-code declares. Only when a printer of that model is active: owning no H2D is the user's situation rather than their mistake, so the file still queues as the unassigned row it has always been, rather than gaining a target nothing can answer. Three gates POST /queue/ has applied for a while now apply here too, because an item reaching the scheduler through this route has to be as printable as one reaching it through that one: the cross-model check that stops a file sliced for one printer being dispatched to another (#2578), the filename check that would otherwise surface as a failed upload hours later (#1540), and the filament requirements the scheduler matches before handing a model-based item to hardware. Nothing inside Bambuddy calls this endpoint -- the Library's own Print action goes through the queue API with a printer already chosen -- which is how it came to drift this far from it. ----- fix(library): scope add-to-queue file reads to the caller The bulk add resolved its files by raw id. Every other read in this module goes through the ownership gate, and so does the single-item queue path; this one did not. Invisible rows are dropped before the loop, so they report as the plain "File not found" an unknown id already gets. |
||
|
|
3a5f802cdc |
fix(diagnostics): read the subnet the host is actually on (issue #3092)
The Network subnet check told the reporter that 192.168.98.170 and 192.168.96.9 were on different networks and to go configure routing between them. They are four hundred addresses apart inside one 192.168.96.0/22 LAN. An IPv4 address does not carry its prefix, and the check supplied /24 for both sides. That is the most common LAN and not the only one, and the guess is wrong in both directions: it splits a /22 and it merges a /25. Read the prefix off the interface that owns the address instead. find_local_ipv4_network() enumerates every interface, including the ones EXCLUDED_INTERFACE_PREFIXES hides. That list keeps docker0 and friends out of the Virtual Printer's bind dropdown; here the caller is asking about an address the kernel has already picked as a route source, and answering "unknown" because it sits on a bridge would be a worse answer than the truth. When nothing claims the address the check skips, which is what it always did with no host IP at all -- it must not assert a split it cannot see. The same check chose which of Bambuddy's own addresses to compare by probing a route toward 10.255.255.255, which on a multi-homed host is not the interface the printer is on. It asks for the route toward the printer now. On a two-NIC dev box that alone was warning about a printer sitting on the second card's own subnet. The probe takes IPv4 literals only. connect() on a name would resolve it on the event loop, and _same_subnet rejects names anyway, so nothing is lost. Resolving the prefix shells out to `ip -j addr show`, so it moves off the loop too. ----- fix(diagnostics): name the container engine instead of asking about Docker (issue #3092) "Not running in Docker - not applicable", said to a Bambuddy inside a Podman container. It reads as "you are on bare metal", and it sent the reporter looking for his problem somewhere else. Podman runs Bambuddy in exactly the two shapes Docker does, and the shape is the thing that breaks printer discovery and the Virtual Printer. detect_container_runtime() names the engine -- Docker, Podman, Kubernetes, containerd, LXC, or a container it cannot place -- and the check became Container network mode. is_running_in_docker() is deliberately left alone rather than rewritten on top of it. Three callers key real behaviour off that flag, and one of them switches the Add Printer flow from SSDP to subnet scanning. SSDP works for a host-networked Podman container, so answering True there would take a working feature away to fix a sentence. Widening it is a separate decision from naming the engine, so it is made separately. Mode detection keeps the original signal first, which also makes the Docker path incapable of regressing: a Docker host always has a docker0, so a container that sees one shares its namespace, and the new rules can only turn a warning into a pass. That signal says nothing about Podman, which creates no such interface on a host running no bridge containers -- which is how host networking came to be reported as bridge. The general form of the same idea answers for Podman: an interface whose iflink equals its ifindex was created in this namespace, and a NAT-networked container only ever receives one end of a veth pair. tun/tap is skipped, because a container may run its own WireGuard and that tun is native to a namespace it is not evidence of. The interface also has to be the one the kernel just named -- sysfs is namespace-tagged but a bind-mounted host /sys is not, and reading a colliding name's numbers would be reading another namespace's answer. What is still unreadable now says so and suggests host networking if discovery is failing, rather than guessing bridge and telling a healthy install to recreate itself. An LXC or LXD system container is named and told the question does not apply: it is on the LAN like a small virtual machine, so there is no network mode to recommend -- and its subnet check still runs. An engine we cannot name is a sentinel the frontend localizes, not a word interpolated into thirteen other languages. The support bundle carries the engine name beside the Docker flag, so the next report of this shape is answerable from the bundle. |
||
|
|
e4a9ef4550 |
fix(spoolbuddy): show the colour name the rest of Bambuddy shows (issue #3090)
SpoolBuddy said "Unknown color" under a correctly-coloured swatch for spools the inventory page names without trouble. The name was never in the spool record. Bambu's RFID tags frequently carry no readable colour name -- some carry an internal code instead -- so Bambuddy has always resolved the swatch's own hex against the colour catalog, and the kiosk was rendering the empty column. Exactly one SpoolBuddy file already did it right, which is what marks this as an inconsistency rather than a kiosk simplification. Route every SpoolBuddy colour-name display through resolveSpoolColorName, which also stops the spools that do carry a code from showing "A06-D0" at the user. The write-tag edit form keeps the raw stored value on purpose: offering a derived name for editing invites the user to save it as though they had typed it. Spoolman has no colour-name field at all, so _map_spoolman_spool puts the spool's subtype there and sets color_name_is_synthesized. That flag now travels on the tag-matched broadcast, and resolveSpoolColorName takes a third argument to honour it -- a synthesised name loses to the catalog and survives only as a last resort. Spoolman installs were reading "Silk+" as a colour on the Inventory page and the AMS hover card too, so those call sites pass the flag as well. Searching by a colour you can read on screen now finds it, in the kiosk and in Bambuddy: the shared inventory filter matches the resolved name as well as the stored one. That makes the filter depend on the catalog, which loads asynchronously, so the three memoised call sites take its version as a dependency -- without that, a query typed before the catalog arrives keeps its empty result and reproduces the very symptom being fixed. The fallback label was hardcoded English in components that already import useTranslation; it is now spoolbuddy.spool.unknownColor in all 14 |
||
|
|
9fc2c6df2d |
fix(camera): stream an external RTSP camera that describes itself late (issue #3082)
An external camera could pass the connection test, play in VLC, and show a black live view that gave up after a few seconds. The two RTSP paths were not asking ffmpeg for the same thing. The one-shot _capture_rtsp_frame passed no probe settings and got ffmpeg's defaults; _stream_rtsp hard-coded -probesize 32 -analyzeduration 0. Thirty-two bytes is enough for a camera that puts its H.264 parameters in the SDP, and not enough for one that sends them in-band a moment later -- a WebRTC source republished through go2rtc, in the reporter's case. ffmpeg then starts no decoder and yields nothing at all, which is why the test button kept passing while the live view stayed black. Those settings were never chosen for external cameras: they arrived with the P2S TLS proxy (#661) as fast-start tuning for the printer camera path, where the source is a known Bambu model, and were copied here in the same commit. This path has no model to tune against and belongs on the defaults, which are a ceiling rather than a wait -- a camera that announces itself in the first packet still starts as fast as it did. Drop the probe cap from _stream_rtsp. Keep -fflags nobuffer and -flags low_delay, which bear on how long ffmpeg sits on frames it already has rather than how long it may look before it has any. Leave _capture_rtsp_frame and the per-model printer profiles alone. Tests pin the absence of both flags, the presence of the low-latency ones, and the property underneath: both RTSP paths must probe alike, or passing the test button again means nothing about the live view. The ffmpeg subprocess fakes move to backend/tests/_fixtures/external_camera.py so the SSRF suite and this one share one definition. |
||
|
|
2c7c97c130 |
fix(jog): send the nozzle-bed gap the API promises on every model (issue #1334)
POST /printers/{id}/bed-jog takes a signed nozzle-bed gap, documented since it
was written: positive asks for more room between the nozzle and the plate. On
an A1 it did the opposite. The reporter sent distance=5 for clearance and
watched the toolhead come down.
The sign had been flipped on A1 models since the original report on this issue,
where an A1 Mini owner clicked an arrow labelled "move the plate up" and watched
the nozzle dive. That is a labelling problem -- a bed-slinger's plate does not
move in Z at all, so closing the gap shows up as the toolhead descending -- and
it was solved in the transport layer, which turned a parameter documented as
model-independent into one that meant the opposite thing on part of the fleet.
Z is the nozzle-to-bed distance on every Bambu model, by definition of the
coordinate system rather than by convention: G1 Z+ opens the gap whether the bed
drops away from a fixed nozzle (X1/P1/H2, whose end G-code parks with
G1 Z{max_layer_z + 100}) or the nozzle rises off a fixed bed (A1/A2L). The
finish-photo plate restore already relies on exactly that and carries no model
branch. So distance goes onto the wire unchanged and one call means one physical
outcome everywhere: positive is the safe direction on every printer.
Which way an arrow points is a different question, about the machine in front of
the user rather than about G-code, so the printer card answers it and asks for
the gap it wants. The buttons move what you would expect them to move, exactly
as before; on a bed-slinger they now say toolhead rather than plate.
The A2L never had the old fix. It slings its bed the same way the A1 does, but
the inversion listed the A1 names and the A2L was not among them, so its up
arrow has been sending the toolhead at the plate for as long as the machine has
been supported. The new classifier also covers the alternate internal codes
A04 / A11 / A12, which LINEAR_RAIL_MODELS and SINGLE_NOZZLE_FLOW_MODELS both
carry and the old gate did not.
is_bed_slinger is gone from the backend rather than widened: with the route
model-independent it had no caller, and a kinematics helper sitting unused in
the service layer invites the next person to assume the backend handles
direction. It does not, deliberately.
Separately, the soft-endstop comments on both jog routes claimed the firmware
clamps a bare move at the travel limit. It does not, and #2579 measured that:
an H2D at its Z limit ran straight past a clean G91/G1 Z-1.00/G90, while its own
touchscreen refuses the identical move. What #2579 removed was M211 S0, which
disabled the limits globally and took the touchscreen's protection with them.
The jog popover has warned about this correctly the whole time; only the code
comments disagreed with it.
|
||
|
|
48244bcfcf |
fix(queue): tell a pinned queue item why it is waiting (issue #3074)
A job queued as "Any X1C" explains itself when it cannot start: the model-based branch builds a reason for every candidate printer and puts it on the row, so the queue shows "Busy: X1C-01" or "Waiting for filament: X1C-02 (needs PETG)". The same job pinned to one printer showed nothing. It sat at Pending with waiting_reason NULL for as long as that printer was busy, which from the outside is indistinguishable from a queue that has stopped working -- the reporter watched fourteen minutes of it while his X1C ran a print he had started from its own screen. The fixed-printer branch had six ways out and none of them wrote the field. The sensor interlock (#1148) was its only writer, and it cleared the field up front on every pass where no sensor was holding the printer, so NULL was not an oversight on those paths but a guarantee. Every exit now writes, through one helper. The reasons reuse the model-based branch's vocabulary so _is_busy_only() keeps deciding what is worth a notification: a printer that is printing, drying, or working through the item ahead of this one reads as "Busy: <printer>" and stays silent, because it resolves itself. A printer that is off with no Auto On plug, and one whose plug could not switch it on, are worth saying. A finished plate nobody has acknowledged is split out from plain busy and named as itself. _is_printer_idle() returns the same plain False for that and for a running print, but they are not the same thing to the person looking at the queue: one clears itself and the other needs somebody to walk over to the printer. That notification fires on the transition into asking, where a busy-only reason counts as not asking. Testing whether the item was waiting at all -- which is what the model-based branch does -- would never fire it here: nobody's queue goes straight from idle to an unconfirmed plate, it waits behind the print first. The cost is that a printer dropping offline, returning busy and dropping again asks twice rather than once. The interlock stays silent. It has never sent this notification, and a change about what the queue displays is not the place to start. Clearing the field up front is gone with it. It existed so a shut door could not leave "Waiting on Enclosure Door" standing while the printer stayed busy with something else, and the new rule carries that guarantee instead -- whichever exit runs next overwrites it, and the dispatch path clears it. Two paths clear it that the report did not mention. A staged item and a future-scheduled one skip before this branch and never reach it again, so anything written on an earlier pass would outlive its condition for the life of the row. That includes the filament-deficit check, which stages the item itself. The notification is wrapped: a queue that cannot say why it is waiting is the bug being fixed, and a queue that stops dispatching because a provider timed out would be a worse one. On the frontend, the queue timeline drops any pending item carrying a reason, on the grounds that such an item will not auto-dispatch. That held while only the model-based branch wrote the field; "Busy: <printer>" is now the commonest reason there is, and it describes the very chain the timeline forecasts, so the rule would have emptied the view for anyone whose queue is pinned. It now asks whether the reason needs the user, via a small shared reader of the same shape the scheduler encodes. Which job goes out, and when, is unchanged: running the previous scheduler and this one over the same 768 states dispatches the same items in the same order with the same statuses, across 1452 rows that now carry a reason. |
||
|
|
5be18ff57a |
fix(queue): print a plate whose filaments are all on the external spool (issue #3087)
The reporter's P1S heated up, sat at Heatbed preheating for ten and a half minutes, then paused with 07FF_8012, "Failed to get AMS mapping table". Resuming only reheated it. Prints that fed from the AMS were fine. The plate was one filament of a seven-filament MakerWorld project, mapped by hand to the external spool. slice_info.config numbers filaments across the whole project, so the mapping for that plate is [-1,-1,-1,-1,-1,-1,254]: six placeholders and the spool holder. The command builder decides whether a print needs the AMS by asking whether the mapping is entirely external, and six -1s answer no. So the print went out as use_ams=true carrying a flat mapping of nothing but -1 -- 254 is deliberately never sent raw, the firmware reads it as AMS tray 0 -- which is exactly the mapping table the firmware then could not find. The builder cannot fix this itself. Down there a -1 is either padding for a filament this plate does not print, which is BambuStudio's own convention, or a slot that never resolved to a tray, and sending the second one to the spool holder is what #2589 exists to prevent. They are the same byte. The scheduler knows. extract_filament_requirements drops every filament with used_g <= 0, so it names precisely the slots the plate prints. When all of those are an explicit 254/255, dispatch now sends use_ams=false and the print runs. When one of them resolved to nothing, the flag is left alone and the firmware rejects the print as it does today -- deliberately, because that is the case where guessing would print a filament in the wrong material without saying so. Single-nozzle only, mirroring the reconcile in the command builder: on a two-extruder printer use_ams selects which nozzle to feed rather than whether to use the AMS, so an H2D with a spool on each side must keep the flag it was given. Judged generously from the model name and from live telemetry -- a second nozzle reporting a diameter, an extruder map, or more than one external feed -- because a wrong yes only preserves existing behaviour while a wrong no would reroute the print. H2S stays single-nozzle (#1386). Nothing in the command builder changed. Its own reconcile keeps the exact semantics #2589, #2595 and #797 gave it, and now usually agrees with a decision that was already made one layer up. Where the file has no parseable filament list the mapping is left exactly as before, the same evidence-only convention as #2771, and the parse itself sits behind a check for anything external at all so an AMS-only print never opens the file. Covered end to end at the dispatcher, including the reporter's seven-filament shape, a plate mixing the spool holder with an AMS tray, a consumed slot that never resolved, both external feeds on a dual-nozzle machine, and a 3MF with no filament list at all. |
||
|
|
8e9821dd2a |
fix(mqtt): never wait for a wedged paho network thread (issue #3068)
The reporter's A1 had been offline 38 hours and still answered on 8883, so the connection watchdog did exactly what it exists for: rebuild the session with a fresh client, since anything left in the old one's QoS 1 queue would otherwise replay onto the next print (#1136). The rebuild ended in paho's loop_stop(), which sets a terminate flag and then joins the network thread with no timeout. That thread only reads the flag between iterations of loop_forever, so it cannot read it while parked inside reconnect() -> _ssl_wrap_socket() -> do_handshake(). paho gives that handshake the keepalive as its socket timeout -- 30s here -- and a socket timeout is per operation, renewed by every byte the peer sends. A printer that answers TCP and then trickles holds the join open for as long as it likes. The join ran on the asyncio thread. Bambuddy stopped answering anything -- UI, API, /health -- while the process stayed up, which is why a restart: unless-stopped container never restarted. Retiring a client no longer waits for it. The replacement is built at once and the old one is shut down on a thread of its own that nobody joins. Its callbacks are detached first, inline: blocking until the network thread was gone is what used to guarantee a client we had let go of could no longer touch our state, and with the teardown detached a zombie that finishes its handshake would otherwise auto-reconnect and report itself connected behind its replacement's back. disconnect() still goes out, still promptly, because that is what stops paho's auto-reconnect and the replay with it. The reported watchdog is one of six callers. The queue's dispatch recovery and check_staleness -- reached from an ordinary status poll -- share _hard_reset_client; editing, deleting and hand-disconnecting a printer share disconnect(); the relay and smart-plug services had the same join on their shutdown path, where a wedged broker stopped the process from exiting at all. #1445 was this join too, from the add-printer probe, and its off-loop teardown stays as it is. disconnect() stays quiet on the way out, as it always effectively did. paho's callback used to land during the join, but it suppresses itself for a clean disconnect of a printer that reported in the last ten seconds, so a healthy printer disconnected by hand never announced itself offline. Announcing it now would tell the user their printer had gone offline a minute after they disconnected it on purpose (#1752). A retirement that takes more than five seconds logs which printer it was. The whole point is that the next one of these should not have to be diagnosed from a thread dump. |
||
|
|
4440738904 |
fix(drying): dry a composite spool as its base material (issue #3067)
The reporter's AMS-HT would not auto-dry PA6-CF, and drying the same spool by hand worked. The scheduler reduced a tray to a preset key by splitting on spaces only, so "PA6-CF" stayed "PA6-CF", matched none of the eight rows the preset table has, and the tray was read as holding nothing worth drying. The AMS was then passed over on every scheduler sweep, silently, because every caller reads "no row" as "nothing to do for this tray". It was never only nylon. Of the 41 types a printer can report, 33 had no row under that rule, and 20 of those have a base material sitting right there: every -CF, -GF and -AERO variant of PLA, PETG, ABS, ASA, PC and PA. Doing it by hand worked because the drying popover has resolved composites since exact key first, so a row the user added for the exact type still wins, then the suffix, then an alias map reading PA6, PA11, PA12, PAHT, PPA and Nylon as PA. PPA is the one alias that is a judgement rather than a spelling. Polyphthalamide is a distinct polymer, not a grade of nylon -- but it is an aromatic polyamide, it takes up moisture the same way, and PA's row is the hottest the table has. A material with no row and no alias is still skipped rather than dried at a number nothing here can source. That is where this parts company with the popover, which falls back to PLA because a dropdown has to show something. The table is user-editable JSON, so a preset row can be present and empty. That has always meant "skip this material" and still does: the temp and hours reads fall back per field to 55C/12h, which would dry a PLA spool at 55 degrees. Two more callers had the same line and move with it: per-filament humidity thresholds, where the override set for a material never applied to that material's composites, and the chamber preheat target, which had the suffix half of this from #2902 but not the aliases. The preheat test for that half reimplemented the lookup inline rather than calling it, so it would have passed whatever the function did. It calls it now. |
||
|
|
a4cfbd4212 |
fix(archives): come back for a 3MF whose transfer ran out of time (issue #3063)
The reporter's P1S had the sliced file on its card and was serving it. The 19MB transfer just did not finish inside the budget while the printer was also running its camera, its status messages and the upload of the job itself. Bambuddy wrote an empty fallback archive and never looked again -- then downloaded that same file successfully three times over the next two minutes and discarded every copy, because the only code that would have attached one had already run. The recovery machinery was there. It was armed for exactly one give-up, the FTPS cool-off, on the grounds that the three storage verdicts are settled: a job on internal eMMC never appears at any FTPS path, and sweeping for it again is what where the file is demonstrably still on the card. The sweep already had the signal and never used it. A file that is genuinely not there is answered with 550, which surfaces as FileNotOnPrinterError and is caught by name; a timeout returns falsy instead. So "the printer says no such file" and "we never got a straight answer" are distinguishable without guessing, and only the second schedules anything. Not scheduled either for a 3MF that downloaded fine and turned out to be another plate's. Recovery checks that a candidate is a readable 3MF but not which plate it holds, and the names a retry would use are the same stale ones that fetched the contradicted file -- so it would put back exactly what #2957 discards. The ladder follows the cause: a cool-off has to expire, so its first attempt sits past the 300s; nothing has to expire here, and this reporter's file completed 48 seconds after the budget was spent. The archives banner gets its own wording for this, because the old text sends an owner whose card is working to switch on a setting that is already on. It names the Connection Timeout setting instead. |
||
|
|
30e530a881 |
fix(archives): let Items Printed go to 0 for a ruined plate (issue #3051)
A jam can destroy everything on the plate while the printer still reports the job as a success, so the honest count of usable parts is zero. The edit dialog floored the field at one, and a project's completed-items count sums that column, so there was no way to record that a job produced nothing. The floor was in the dialog only; the API stored whatever it was given, which also meant a negative count was accepted and would have subtracted from the project totals. The column is now bounded at zero instead. Filament Trends counted prints as `quantity || 1`, which would have read a deliberate 0 as "unset" and charged the ruined plate as one print while the project page counted none. |
||
|
|
7fb495a102 | Updated BACKERSS | ||
|
|
27f498aa36 | Updated BACKERS | ||
|
|
0b830ac35c |
fix(ams): stop reading the printer's command acks as status (issue #3040)
Every project_file carried "cfg": "0" — the device-config bitmask, which Bambu Studio has never sent and the firmware ignores. The printer echoes a command's fields back in its ack, and the ack was ingested as telemetry, so bit 18 read as "AMS Filament Backup off" 25 ms after every dispatch. Families that repeat cfg in their periodic status (P2S, H2C, X2D) corrected themselves a second later; the P1S, A1, A1 Mini and A2L send it only in a full status dump, so the wrong value stuck and silently disabled the prefer-lowest-remaining gate. The A1 family, which reports no cfg at all and is meant to stay "unknown", was pinned to a definite "off". Acks are no longer read as status, for the backup bit or the per-job timelapse flag they also echo, and cfg is gone from the print command. |
||
|
|
6017981e62 | Updated BACKERS and SPONSORS | ||
|
|
c116bb8d21 |
chore(deps): bump vitest to 4.1.11 for the mocker path-traversal advisory
@vitest/mocker registers a redirect mock's target without checking it against Vite's file-serving allowlist, and the load hook then returns readFile(mock.redirect) as the module source. The target is built as join(root, new URL(redirect).pathname), which confines nothing -- a non-special scheme keeps ".." in pathname, so the join resolves outside the project root. GHSA-82fw-gwwq-j7x9, CVSS 5.9, CWE-22. Not reachable here. The unauthenticated path is the public mockerPlugin and interceptorPlugin exports, which attach to Vite's unauthenticated HMR socket for the benefit of third-party dev servers; nothing under frontend/src imports either. Browser mode, which registers over a token-authenticated RPC, is not installed -- @vitest/browser is an unmet optional peer -- and vitest.config.ts runs plain jsdom, so no dev server listens during a test run. Both packages are devDependencies and reach no shipped artifact. vitest and the eight @vitest/* packages go 4.1.8 -> 4.1.11, carrying es-module-lexer, expect-type, obug, std-env, tinyexec and tinyrainbow. Fifteen lockfile entries, all dev-scoped, none added or removed. The ^4.1.8 range already admitted the fix, but the declared floor is raised so a regenerated lockfile cannot resolve back beneath it. No src change, so the bundle is byte-identical and static/ does not move. |
||
|
|
309e64b8a2 |
fix(ams): resolve a slot's K profile by index when the printer does not file per hotend (issue #3044)
An X2D with two AMS 2 Pro, one per hotend, showed a K value on every slot of the first and nothing on any slot of the second. Configure Slot was worse than blank there: the picker offered no matching profile, the slot read as though nothing were bound, and choosing one changed nothing the user could see. Both symptoms are one rule. A calibration index can mean two different profiles on a dual-nozzle machine -- on the maintainer's H2C, index 16 is the left hotend's black PLA at K=0.018 and 15 is the right's at K=0.020 -- so the index is resolved against the slot's own hotend, and a miss shows nothing rather than the other nozzle's number. That is right whenever the printer files its calibrations per hotend. This one files them per filament: the second AMS's slots point at the same entries as the first, every entry tagged with one extruder, and requiring a match found nothing at all. The hotend now has to appear in the table the printer actually sent before it is used to narrow anything. Where it does not, the index stands on its own, which is what BambuStudio does for this same card -- AMSItem.cpp resolves it through get_pa_k_n_value_by_cali_idx, matching cali_idx and nothing else. Where it does, nothing changes: the H2C case still blanks rather than borrowing, and the other hotend's profiles stay reachable under Other K profiles. The relaxed path still refuses an answer when the candidates disagree on a value. The premise that the table is always numbered per nozzle had been written into three comments and two layers of code; it is corrected where it appears. Alongside it, in the same picker: the K-profile options rendered the hotend suffix twice in the matching group and three times under Other, so every option on a dual-nozzle printer read "... . Left . Left". |
||
|
|
f5cdc86689 |
fix(queue): chain the Timeline in the scheduler's order, not queue position (issue #3043)
Turning Shortest Job First on reordered the pending list and the scheduler, and left the Timeline drawing the pre-SJF queue for good. It chained each swimlane's bars by queue position alone and was never told the setting existed -- so the one view whose whole job is to say when each print will run was the one view answering for an order the scheduler had no intention of using. Bars now chain in the order the scheduler will dispatch: jumped items first, then shortest print time with an unknown duration last, then position. The starvation guard is visible there too, so a long print that has finally come up reads as next rather than staying buried behind every short job on the lane. Three surfaces claim to show queue order -- the pending list, the "if started now" ETA, and the Timeline -- and each had its own copy of the comparator, which is how one of them came to be missing a whole clause. They now share one, written against the scheduler's ORDER BY. Grouping came along with it: the pending list folded a model name down to its first character to build a lane key, so Any X1C and Any X2D both landed on -88 (as did Any P1S and Any P1P) and the two lanes interleaved into a single run of rows. Backend untouched. The scheduler was dispatching correctly the whole time; only the drawing of it was wrong. |
||
|
|
069ee8fc87 |
fix(queue): skip preheat entirely when no loaded filament wants a chamber (issue #3041)
Preheat & Heat Soak delayed every PLA print by five to seven minutes and gave nothing back. The filament map correctly derived a chamber target of 0, and the chamber phase correctly skipped -- but the stage then heated the bed, waited for it, and held the full soak anyway, because the soak had no idea it was holding for a chamber nobody asked for. The print's own G-code sets the bed the moment it starts, so the bed phase only moved the warm-up ahead of the FTP upload instead of overlapping with it. A 0 that comes out of the filament map now skips the stage before any command goes out. The one thing the skip still does is put the airduct flap back to cooling on the models that have one -- an H2D left in heating mode by the ABS job before it would otherwise cook the PLA that follows, and that costs one MQTT command and no waiting. Explicit instructions are untouched. A chamber target of 0 typed into a print's own override still heats the bed and runs the soak, which is what the queue documentation has always promised it does, as does forcing a print's Preheat override to On. Prints that want chamber heat are unaffected, including the P1S/P1P/A1 tier where the bed and the soak timer are the whole mechanism. The existing unit tests all ran with soak_seconds=0, which is why the production default was never exercised; the PLA test now runs at the real default and asserts nothing is dispatched and nothing is slept. Surfaced in the UI on the way through: the Settings hint claimed the derived 0 skipped "the chamber phase", and the per-print chamber override field said nothing about a typed 0 meaning bed-only -- a user reaching for 0 to turn preheat off got the delay instead. |
||
|
|
9a837d19a1 |
fix(slicer): strip zero-valued filament-index sentinels, and sanitise the preview slice too (issue #3030)
Bambu Studio writes 0 into wall_filament, sparse_infill_filament and solid_infill_filament to mean "use whichever filament the object is set to". Bambu Studio and OrcaSlicer 2.4 define these min 0 and accept it; OrcaSlicer 2.3 and earlier used the 1-based scheme (min 1, default 1) and reject it with "0 not in range [1.000000,...]". Sidecar images are version-tagged, so an install can be pinned to one of those builds. Same shape as the -1 inherit markers from #1201 with a different marker, so the allowlist becomes a key-to-marker map rather than one global constant. The buckets must not bleed: a -1 on a filament index is a real value, and a 0 on a raft field is a setting the user chose. The key is removed rather than rewritten, which is what makes it safe on every build. The CLI then uses its own default: 0 where 0 was legal (unchanged), 1 on the older builds, which is what "the active filament" means under that scheme. The preview slice never ran the sanitiser at all, so a file that sliced fine could still fail its automatic plate preview and fall back to the painted-face heuristic. It matters more there than in a real slice: the preview runs on the file's own embedded settings, so there is no --load-settings pass that could supply a replacement for a field the range validator has already rejected. That also explains the reported "same error on a later attempt of an unchanged file" without any second copy of the keys -- the validator that emits it reads the merged global config, which per-object model_settings.config overrides never reach. The sanitiser moves to utils/threemf_tools so the service can use it without importing a route module, and both preview callers pick it up from one place. Drops _strip_3mf_embedded_settings and its constant, which have had no callers since the strip-everything experiment was reverted. |
||
|
|
e2493132bf |
fix(slicer): offer the desktop handoff only for formats the target slicer accepts (issue #3029)
The Slice action and Open in Slicer offered .stl, .step and .stp alongside .3mf, on the assumption that a slicer which opens an STL from its own File menu will open one from a link. Bambu Studio does not. Every bambustudio:// and bambustudioopen:// URL reaches one import path that refuses any filename which is not .3mf, and refuses it before fetching anything: "Download failed, unknown file format." The message names the format, so the failure reads as a broken model rather than an unsupported handoff. OrcaSlicer has no such limit. Only MakerWorld links take its equivalent path; a link to the user's own Bambuddy goes to its general downloader, which does not inspect the extension. So the format list becomes per slicer. isSliceableFilename and isSliceableFileType take the target as a required argument -- a default would quietly reintroduce the handoff that cannot work -- and an unrecognised value falls back to the Bambu Studio list, which is where openInSlicer sends anything that is not exactly 'orcaslicer'. The File Manager offers Slice only when the configured desktop slicer will take the file. The 3D preview reaches both slicers from one split button, so instead of hiding it promotes whichever can take the file to the primary action, naming that slicer when it is not the configured one; the split collapses to a plain button when no alternative is left. The sidecar path is untouched: with Use Slicer API on, Slice still takes STL and 3MF whatever the desktop target is. |
||
|
|
b9bd312826 |
fix(slicer): keep protocol-handler download tokens valid for their whole TTL (issue #3029)
The Slice and Open in Slicer actions mint a short-lived token and put it in the URL, because a protocol handler cannot carry an Authorization header. That token was spent by the first request to reach the endpoint, which made the handoff depend on the slicer fetching the URL exactly once. Nothing guarantees that: Bambu Studio's downloader retries three times after a failed attempt, transfers get resumed, on-access scanners fetch. The first request won and the slicer was handed a 403. verify_slicer_download_token takes a keyword-only single_use flag. The default still consumes via DELETE...RETURNING; single_use=False verifies with a SELECT and leaves the row for the rest of its five-minute TTL. The stored row is the same either way, so the endpoint decides, not the mint. The three protocol-handler downloads pass single_use=False: a library file, an archive's sliced 3MF, an archive's source 3MF. Resource binding and expiry are untouched. The two browser downloads keep consuming, because what they hand over is itself consumed -- the prepared printer bundle is deleted the moment it has been streamed. Also: add "/source-dl/" to PUBLIC_API_PATTERNS. Those patterns match by substring and the source 3MF route's segment is source-dl, which does not contain "/dl/", so with auth enabled the middleware rejected the slicer's header-less request before the route's token check ran. Open source 3MF in slicer could never work on an install with authentication on. |
||
|
|
816f073a9e |
fix(auth): decouple media routes from the camera stream token (issue #3025)
Thirteen routes with nothing to do with a camera took the camera stream
token as their credential -- library and archive thumbnails, plate
previews and plate thumbnails, timelapses, print photos, archive QR
codes, project covers, print-log thumbnails, printer covers and
external-link icons. A browser cannot put an Authorization header on an
<img src>, so these need a credential that fits in the URL, and the
camera token was the only one that existed. Minting one costs
camera:view, so a user granted library access to their own files got a
grid of broken images until they were also handed the live camera.
Adds a media token: minted by POST /auth/media-token behind plain
authentication, and identified -- it records the principal the way the
websocket token does rather than being anonymous the way the camera
token is. Each route now gates on the permission and ownership rules of
the resource it serves, through the same _ensure_*_visible helpers its
header-authenticated siblings already use. The three camera routes keep
the camera token, and require_camera_stream_token_if_auth_enabled now
documents that it is for those only.
The media dependencies accept ordinary Authorization / X-API-Key headers
as well as ?token=, delegating that path to the existing checkers, so
API-key scope rules and the per-printer allowlist are unchanged.
Long-lived camera_stream, camwall and overlay tokens are deliberately
not accepted on the media routes -- those are handed to kiosks, walls
and Home Assistant to display video. The cam wall, streaming overlay and
kiosk views use only the three camera routes and are unaffected.
Frontend: withMediaToken alongside withStreamToken, and
useStreamTokenSync fetches a media token for every signed-in user while
asking for a camera token only when the user can mint one, which also
stops the 403 that fired on every page load for everyone else.
Also fixed, same class:
- /printers/{id}/files/plate-thumbnail/{i} is rendered in an <img> but
had a header-only guard, so the file manager's plate thumbnails 401'd
whenever auth was enabled. It now takes a media token too.
- getProjectCoverImageUrl returned a URL ending in ?token=, and the
project edit dialog appended its own ?v= cache-buster after it, so the
second ? landed inside the token value. The version is now a parameter
applied before the token.
Tests: 15 integration tests for the token boundary, permission
enforcement and per-row scoping; 10 frontend tests for the URL split and
the two-query hook. test_cover_image_get_uses_stream_token_gate is
renamed and repointed at the media gate -- what it pins, that the
credential has to fit in a URL, is unchanged.
|
||
|
|
93eeb05264 |
fix(auth): let the sidebar read install flags without settings:read (issue #3023)
cost_centers:read_own exists so a non-admin can see their own wallet, balance and cost-centre spend, and the Finance page honoured it -- typing the URL worked and rendered their balance. The sidebar never offered the entry. It decides whether to show Finance by reading billing_enabled from GET /settings, which requires SETTINGS_READ. A non-admin gets 403 there, so the value arrived undefined, `undefined !== true` held, and the entry was hidden from precisely the users the permission was written for. The permission map and the route guard were both already right; only discovery was broken. Three more fields came from that same 403, and one of them failed the other way up. The Notifications gate tests `=== false`, which undefined never satisfies, so an administrator who switched user notifications off still left the entry showing to the non-admins it governs. Nobody reported that one, and no administrator could have reproduced either: administrators can read /settings. The remaining two were quieter -- the sponsor prompt fell back to EUR whatever the install uses, and the update check ran where it had been turned off. SETTINGS_READ cannot be the price of knowing whether billing is on. It also grants sight of the SMTP, LDAP and MQTT credentials, which is the reason /settings/ui-preferences exists at all. So: a second endpoint, GET /settings/ui-flags, carrying those four fields and asking only that the caller be signed in, via the existing require_auth_if_enabled. Layout drops its /settings query altogether, which closes the class rather than the two instances that happened to be visible. Deliberately not four more fields on /ui-preferences. That endpoint is served to anyone at all on the recorded grounds that its contents are "public defaults that ship with the app" (test_route_auth_coverage.py), and its field set is pinned by a test written to make anyone adding to it stop and think. These fields are not defaults -- they say how this deployment is configured -- so they get their own endpoint at their own trust level instead of stretching that charter to fit them. require_auth_if_enabled also keeps the auth-disabled case that /ui-preferences was ungated for: "works when there is no auth" and "readable by anyone" are different statements, and conflating them is what put a settings read in front of a permission that never needed one. Twelve tests. Backend pins that the operator can read the flags, that the same operator still gets 403 from /settings, that an anonymous caller is refused when auth is on, that it answers when auth is off, the exact field set, that no credential ever appears, and that the public endpoint did not quietly gain these fields. Frontend pins Finance visible for cost_centers:read_own with /settings returning 403, and Notifications hidden when the flag is off -- each waiting on a positive signal before asserting an absence, so the negative cases cannot pass before the query resolves. Reported by @lonix, who traced it to the queryKey and the route gate. |
||
|
|
09b4584d5f |
fix(queue): say when an unscheduled item runs instead of calling it ASAP (issue #3018)
The print dialog offers ASAP, Queue and Schedule. ASAP and Queue differ only in where the item is inserted, and neither is stored on the item -- scheduleType is a frontend-only concept, and grep finds no "asap" anywhere in the backend. So the queue's time column had nothing to read but scheduled_time, and labelled every unscheduled item "ASAP": the name of the one mode the user may well have chosen against. Someone who picked Queue then watched their row appear as ASAP and start immediately, and concluded Bambuddy had overridden them. Two reporters wrote that same sentence thirteen months apart, and #2557 was closed as A2L-specific after the first of them -- kilrah replied there with an X1C before filing this. The column answers when an item runs, so it now says that. The key is renamed whenFree rather than just retranslated: left called asap, the next translator puts ASAP back. The dispatch is unchanged, because it was right. A print scheduled for later does not reserve the printer until then; an unscheduled item behind it uses the idle printer rather than leaving an X1C dark until 6 AM. Two of the new tests pin that, so it does not get "fixed" later on the strength of a report like this one. What genuinely could not answer the question was the queue's own log. Its per-printer line called every entry in busy_printers "not available" -- but that set holds both printers that cannot take work and printers the pass has just claimed for some, which are opposite facts. It also read printer state at logging time rather than at the decision, so #3018's bundle carries Queue: printer 1 not available — connected=True, state=IDLE, ... Launching 1 upload(s) (pool 0/4 in flight) Starting queue item 18 a printer reported unavailable, evidence that it was available, and a dispatch to it, in three consecutive lines. It is the first line anyone greps for "why did my item not go out". Each of the nine sites that removes a printer from a pass now records why, and the summary reports a claim as a reservation and everything else as an obstruction with its reason. The live fields stay, since a bundle reader wants them next, but are labelled as read now rather than offered as the cause. print_scheduler.py:1210 already documented that these two meanings differ -- the dispatching_printers snapshot exists for it. This carries that distinction into the log. |
||
|
|
6564c74071 |
fix(archives): report a refused FTPS handshake as the printer, not the slicer (issue #2780)
The Archives banner picks its wording from a priority list of the causes it knows. REASON_FTPS_COOLOFF was added by #2957 and never put in that list, so an install whose empty archives all came from a printer refusing the TLS handshake matched nothing, got reason: null, and fell to the original wording: the slicer did not leave the .gcode.3mf on the card, switch on "Store sent files on external storage", here is installation step 4. Every clause of that is wrong for this cause. The slicer did write the file -- reason he read the whole thing as Bambuddy being broken. The setting was already on. And there is nothing on his side to change: the printer's file service answered port 990 with something that is not TLS, so no lookup ever ran and where the file went was never tested. It is #2899's mistake -- an error message describing a cause that was ruled out before it was printed -- in a surface that did not get that pass. The slug now leads the list rather than joining the end of it. The other three describe an install working as configured and each ends in something the operator can change; this one reports a fault nobody can yet explain, which is both the more urgent thing to say and the thing that produces a useful report. The banner also dismisses one-shot into localStorage, so a reason ranked below another is not deferred to next time -- it is never shown to that user again. Ranking it first cannot bury a permanent cause in exchange: a successful recovery clears the row's markers (#2957), so a row still carrying this slug is one whose retry failed too, days after the print. New wording in all fourteen languages says the printer refused the connection, that this is not a slicer setting and not something the operator did, that Bambuddy comes back for the file when the five-minute pause clears so a brief episode fills itself in, and that a card still empty means the refusal outlasted the retry. It links to the handshake entry in the troubleshooting guide instead of to the installation guide. The client's getNo3MFWarning type still declared the old three-slug union, which made all three new comparisons provably dead -- caught by tsc, not by any test. Four tests. One pins the slug reaching the banner, one pins it outranking the three settled causes, one pins those three keeping their order behind it, and one asserts the rendered wording carries no slicer advice at all. Also corrects the wiki page these reports are pointed at. It said to power-cycle the printer; the reporter who prompted that advice power-cycled both of his and the failure continued unchanged, and bambu_ftp.py has carried the retraction in a comment since. The page now states what was actually measured -- that a version mismatch reports itself differently, that every printer probed refuses TLS 1.3 and completes on 1.2 so there is no version to fall back from, and that three P2S units failed while three more on the same switch never did -- says plainly that the trigger is unknown, and names the one cleartext-probe line worth collecting. |
||
|
|
10f0900fbc |
feat(ftp): log how every FTP session closes (issue #3009)
disconnect() and _abandon_connection() logged nothing, at any level. A session closed cleanly and a socket genuinely abandoned therefore produced identical output -- none -- and the only way to tell them apart was to read the source. That is how #3009 was filed. Its trace shows a print completion opening two FTP connections, deleting one file, and then nothing until the printer was powered off 21 minutes later, read as connections left open and offered as a mechanism for the 0500-C010 SD-card error that #645 has been chasing since April. The two connections are the post-print SD cleanup in main.py walking its candidate filenames, each through delete_file_async, which closes in a finally; running that against the mock FTPS server shows the server logging "FTP session closed (disconnect)" for both the 250 and the 550, holding zero sessions afterwards. Nothing in a support bundle could have shown that. Both close paths now log one DEBUG line: the printer, whether QUIT was acknowledged or the socket had to be dropped without it, why, and how long the session was held. Every connect in a debug log now has a matching close. The duration comes from a stamp taken when the control socket opens rather than after login, so a session that dies during login is accounted for too; where no socket was ever established the line says "held unknown" rather than claiming a number. The four connect() failure paths pass their own reason, so a close line stands on its own next to the warning above it. Nine tests, seven of which fail against the unlogged version. The other two assert silence -- a bare disconnect(), and a connect skipped by the handshake cool-off -- where no socket was opened and a close line would pair with no connect. |
||
|
|
f3b1c59169 |
fix(orca-cloud): close the HTTP client when an authenticated build fails
OrcaCloudService owns an httpx client from construction, and every path in _build_authenticated_service after that point can raise: no stored refresh token, a rejected refresh, an unreachable Orca, and the token-rotation write. On success the caller closes the client. On failure nobody is ever handed it, so all four paths leaked one into the connection pool. That went unnoticed while the only callers were routes, where the trigger is a person retrying a broken sign-in a handful of times. It stopped being harmless in |
||
|
|
9434875fa1 |
fix(ams): resolve a custom filament's own id from every preset source (issue #3003)
A custom filament profile reaches an AMS slot as itself through exactly one field, tray_info_idx, and every source we can read that id from was reading it from the wrong place or not reading it at all. Bambu Cloud returns a preset's own filament_id either on the response envelope or inside the preset JSON under `setting`, and only the envelope was read. Presets of the second shape fell through to the base_id branch and reached the slicer as the Bambu filament they inherit from. filament_type next door already handled both spreads; filament_id now does too. Orca Cloud was absent from the resolver entirely. A spool stores the bare profile UUID, which matched no branch and fell through normalize_slicer_filament -- a function that passes anything it does not recognise straight through -- so a 36-character UUID went into the field. Orca profiles carry their own filament_id in the slicer JSON that OrcaProfileDetail already exposes under `setting`, so the lookup is the same one the Bambu branch does. It is best-effort: no pairing, a dead token or a missing orca_cloud:auth permission degrades to the fallback rather than failing the assignment, and it passes clear_on_auth_failure=False because a background caller cannot tell a real revocation from a lost refresh-rotation race. configure_ams_slot sent the cloud setting_id as tray_info_idx when it found no real filament id. That field is 8 characters on the printer -- exactly the width of a local preset id, less than half a cloud one. Measured on the reporter's A1: sent PFUS9ddc938fe3ab8f, the tray read back PFUS9DDC, acknowledged as a success. The slot then resolved to nothing, so the slicer showed Generic anyway and the calibration table, keyed by the same field, lost the slot. It now falls back to the slot's existing filament id or the generic for the material, and the route's guard was aligned with the resolver's so both refuse the same four shapes from one shared definition. This reverses the contract #1053 pinned. Six tests asserted that the PFUS belonged in tray_info_idx; the A1 capture shows it never worked, so they were rewritten with the measurement in their docstrings. Verified against 874 AMS trays across twelve models in the support archive: 92 already carry a custom "P" + 7 hex filament id, which is what confirms the mechanism works and this is a lookup failure rather than a platform limit. No tray on any model carries a setting_id, so a profile with no filament_id of its own still cannot be told apart from its base. |
||
|
|
5ab0a4cb11 | fix(ui): make hover:text-white theme-aware so light-theme labels survive hover (issue #1909) |