The daemon took tray_uuid from tag blocks 4-5, which hold the filament
type, so every spool of one type sent the same value and the kiosk never
saved it. Read block 9, which both tags of a spool share and the AMS
reports as tray_uuid. Save it on kiosk quick-add and link in local and
Spoolman mode, and give spools added before the fix their tray_uuid when
their exact tag UID is scanned again. Drop any tray_uuid that is not a v4
UUID, so daemons that are not updated yet keep matching by tag UID.
Block 9 read based on #1200 by @Keybored02.
Co-Authored-By: Keybored02 <Keybored02@users.noreply.github.com>
Reporter on a Raspberry Pi 5 couldn't read NFC tags — gauge worked,
SPI bus and wiring fine, but PN5180 transfers didn't complete.
Manually commenting out `self._spi.no_cs = True` restored
communication. Root cause: Pi 5's RP1 southbridge SPI driver
(spi-rp1) doesn't honour the SPI_NO_CS ioctl the way the historical
Broadcom driver on Pi 4 did.
Safe to relax Pi-wide. SpoolBuddy's PN5180 NSS line is wired to
GPIO23 (manual CS in _cs_low / _cs_high — the kernel's default
auto-CS timing doesn't meet the PN5180's 5µs setup / 100µs hold
spec). The hardware CE0 line (GPIO8) is not connected to the
reader, so whether the kernel auto-toggles it is electrically
invisible. The no_cs = True call was always cosmetic on this
hardware.
Wraps the assignment in try/except OSError in both the daemon and
the diagnostic script; the daemon logs at debug level so future
Pi-5-specific triage is greppable. README updated to drop the
"spidev.no_cs = True resolves this" sentence and explain the
manual GPIO23 CS scheme carries the timing on its own.
The read_tag.py diagnostic script had stale PN5180 NTAG methods: TX CRC
was off (should be on), no Crypto1 clear, no IDLE→TRANSCEIVE state
reset, and the PN5180 drops the card after each READ batch requiring
reactivation between 4-page reads. Also rejected SAK 0x04 as
unsupported. Synced register setup with daemon and added per-batch
card reactivation.
The PN5180 cannot read more than 4 NTAG pages after a batch write:
the second READ command (page 8+) returns rx_status=0 regardless of
state machine reset strategy. The write itself succeeds (tag ACKs
via SOF on every page). Remove verification and trust the writes.
Repeated IDLE→TRANSCEIVE resets inside the read loop broke the card
session after the first READ (page 8 returned rx_status=0). Match
the activate_type_a pattern: IDLE→TRANSCEIVE once before the loop,
set_transceive_mode() for subsequent iterations.
The verification read after writing failed because ntag_read_pages()
used set_transceive_mode() which was a no-op when already in
TRANSCEIVE. Apply the same IDLE→TRANSCEIVE reset pattern used in the
write path, clear Crypto1, and add diagnostic logging.
IRQ logging revealed the tag IS responding (RX_SOF_DET set) but the
PN5180 cannot capture the 4-bit ACK as a complete frame — RX_IRQ
never fires and RX_STATUS stays zero. Skip per-page ACK checking
and rely on the read-back verification in ntag_write_pages().
The PN5180 transceive state machine wasn't being reset between the
SELECT (from reactivate_card) and the WRITE command — just re-setting
the TRANSCEIVE bits was a no-op. Use IDLE→TRANSCEIVE transition like
activate_type_a does. Also clear Crypto1 bit and add IRQ status
logging.
Temporary diagnostics to identify which step of the NTAG write
fails: per-page ACK status, reactivation, read-back, or data
mismatch. Enable DEBUG level for pn5180 module.
The NTAG WRITE ACK is 4 bits (0x0A), not a full byte. The PN5180
RX_STATUS register reports 0 complete bytes with 4 extra bits, but
the check only looked at the byte count — returning False on every
successful write. Check both byte and bit fields of RX_STATUS.
Also bump post-write delay from 5ms to 10ms for margin.
Three issues:
1. SAK gate too strict — NTAG chips can report SAK 0x04 (MIFARE
Ultralight family) instead of 0x00. Accept both in nfc_reader.py
and main.py.
2. TX CRC disabled for NTAG WRITE — the NTAG spec requires CRC on
the WRITE command frame. Enable TX CRC in ntag_write_page().
3. TX CRC disabled for NTAG READ — the post-write verification read
also failed because ntag_read_pages() sent the READ command
without CRC. Enable TX CRC there too.
Two issues:
1. SAK gate too strict — NTAG chips can report SAK 0x04 (MIFARE
Ultralight family) instead of 0x00. Accept both in nfc_reader.py
and main.py.
2. TX CRC disabled during WRITE — the NTAG WRITE command (0xA2)
requires a CRC on the frame. The PN5180 was sending without CRC,
causing the tag to NAK every write. Enable TX CRC for writes
(RX CRC stays off for the 4-bit ACK).
The NAU7802 ADC returns a stale max-scale value (0x7FFFFF) on its
first conversion after power-up, polluting the moving average and
making the initial weight report wildly inaccurate. Flush the first
reading during init().
Also extract both hardware drivers out of diagnostic scripts into
proper daemon modules:
- NAU7802 scale driver: scripts/scale_diag.py -> daemon/nau7802.py
- PN5180 NFC driver: scripts/read_tag.py -> daemon/pn5180.py
The production daemon was importing driver classes from test scripts
since the original SpoolBuddy commit. Diagnostic scripts now import
from the driver modules. Removed the sys.path hack from main.py.