Fix Read Tag diagnostic failing on NTAG tags
The read_tag.py diagnostic script had stale PN5180 NTAG methods: TX CRC was off (should be on), no Crypto1 clear, no IDLE→TRANSCEIVE state reset, and multi-batch reads failed because subsequent READ commands need a full state machine reset between batches. Also rejected SAK 0x04 as unsupported. Synced register setup and write methods with daemon.
This commit is contained in:
+1
-1
@@ -22,7 +22,7 @@ All notable changes to Bambuddy will be documented in this file.
|
||||
- **SpoolBuddy System Tab** — Added a "System" tab to SpoolBuddy Settings showing live OS stats from the Raspberry Pi: CPU temperature, core count, load average, memory usage, disk usage, OS distro/kernel/architecture, Python version, and system uptime. Stats are collected by the daemon every heartbeat (10s) using stdlib-only reads from `/proc` and `/sys` — no additional dependencies required. Usage bars turn amber at 70% and red at 90%; CPU temperature is color-coded green/amber/red.
|
||||
|
||||
### Fixed
|
||||
- **SpoolBuddy Read Tag Diagnostic Fails on NTAG Tags** — The `read_tag.py` diagnostic script had four issues preventing NTAG reads: (1) SAK `0x04` (MIFARE Ultralight family) was rejected as "unsupported tag type" — now accepts both `0x00` and `0x04`. (2) `ntag_read_pages` had TX CRC off (should be on per NTAG spec), no Crypto1 clear, and no IDLE→TRANSCEIVE state reset. (3) The PN5180 drops the NTAG card after each 4-page READ batch — added card reactivation between batches so multi-batch reads (pages 4-20) succeed. (4) `ntag_write_page`/`ntag_write_pages` had the same stale CRC/state issues plus unreliable ACK checking and post-write verification — synced with daemon.
|
||||
- **SpoolBuddy Read Tag Diagnostic Fails on NTAG Tags** — The `read_tag.py` diagnostic script had four issues preventing NTAG reads: (1) SAK `0x04` (MIFARE Ultralight family) was rejected as "unsupported tag type" — now accepts both `0x00` and `0x04`. (2) `ntag_read_pages` had TX CRC off (should be on per NTAG spec), no Crypto1 clear, and no IDLE→TRANSCEIVE state reset. (3) The PN5180 needs a full IDLE→TRANSCEIVE state machine reset between each 4-page READ batch — added between-batch resets so multi-batch reads (pages 4-20) succeed. (4) `ntag_write_page`/`ntag_write_pages` had the same stale CRC/state issues plus unreliable ACK checking and post-write verification — synced with daemon.
|
||||
- **Delete Tag Leaves Stale Tag Type** — The "Delete Tag" button in the spool edit modal only cleared `tag_uid` but left `tray_uuid`, `tag_type`, and `data_origin` intact. All tag-related fields are now cleared together.
|
||||
- **SpoolBuddy NFC Write Fails on NTAG Tags** — Multiple issues prevented writing to NTAG 213/215/216 tags. (1) Some chips report SAK `0x04` (MIFARE Ultralight family) instead of `0x00` during anticollision — both `0x00` and `0x04` are now accepted. (2) TX CRC was disabled for NTAG commands but the spec requires it — enabled for both WRITE and READ. (3) The PN5180 state machine needed IDLE→TRANSCEIVE resets (not just `set_transceive_mode()`) and Crypto1 cleared before NTAG operations. (4) The 4-bit WRITE ACK cannot be captured by the PN5180 (SOF detected but no RX_IRQ) — removed per-page ACK checking. (5) Post-write read-back verification also failed (second READ command gets no response from the PN5180) — removed verification since the tag reliably ACKs each write.
|
||||
- **Database Connection Pool Exhaustion on Large Printer Farms** — Users with 100+ printers connected simultaneously experienced `QueuePool limit of size 10 overflow 20 reached, connection timed out` errors. Increased the SQLAlchemy connection pool from 30 total (10 base + 20 overflow) to 220 (20 base + 200 overflow), and raised the SQLite busy_timeout from 5 to 15 seconds to reduce write contention under heavy concurrent MQTT updates.
|
||||
|
||||
@@ -372,53 +372,48 @@ class PN5180:
|
||||
|
||||
return self.read_data(16)
|
||||
|
||||
def _ntag_setup_and_read_one(self, page: int) -> bytes | None:
|
||||
"""Setup registers and read 4 NTAG pages (16 bytes) starting at page."""
|
||||
# Crypto1 off, TX CRC on, RX CRC off
|
||||
self.write_reg_and(0x00, 0xFFFFFFBF)
|
||||
self.write_reg_or(0x19, 0x01)
|
||||
self.write_reg_and(0x12, 0xFFFFFFFE)
|
||||
self.write_reg(0x03, 0xFFFFFFFF)
|
||||
|
||||
# IDLE → TRANSCEIVE
|
||||
sys_cfg = self.read_reg(0x00)
|
||||
self.write_reg(0x00, sys_cfg & 0xFFFFFFF8)
|
||||
time.sleep(0.001)
|
||||
self.write_reg(0x00, (sys_cfg & 0xFFFFFFF8) | 0x03)
|
||||
time.sleep(0.002)
|
||||
|
||||
# READ command: 0x30 + page → returns 16 bytes (4 pages)
|
||||
self.send_data([0x30, page])
|
||||
time.sleep(0.010)
|
||||
|
||||
rx_status = self.read_reg(0x13)
|
||||
rx_len = rx_status & 0x1FF
|
||||
if rx_len < 16:
|
||||
print(f" NTAG read page {page}: rx_len={rx_len} (expected >=16)")
|
||||
return None
|
||||
|
||||
return self.read_data(16)
|
||||
|
||||
def ntag_read_pages(self, start_page: int, num_pages: int) -> bytes | None:
|
||||
"""Read NTAG pages (4 bytes each). No authentication required.
|
||||
|
||||
Uses NTAG READ command (0x30) which returns 4 pages (16 bytes) at a time.
|
||||
The PN5180 drops the NTAG card after each READ, so we reactivate between
|
||||
each 4-page batch.
|
||||
Reads all requested pages in a single activated session — the card must
|
||||
already be selected via activate_type_a() or reactivate_card().
|
||||
"""
|
||||
# One-time setup: Crypto1 off, TX CRC on, RX CRC off, IDLE→TRANSCEIVE
|
||||
self.write_reg_and(0x00, 0xFFFFFFBF) # Crypto1 off
|
||||
self.write_reg_or(0x19, 0x01) # TX CRC on
|
||||
self.write_reg_and(0x12, 0xFFFFFFFE) # RX CRC off
|
||||
self.write_reg(0x03, 0xFFFFFFFF) # Clear IRQs
|
||||
|
||||
sys_cfg = self.read_reg(0x00)
|
||||
self.write_reg(0x00, sys_cfg & 0xFFFFFFF8) # IDLE
|
||||
time.sleep(0.001)
|
||||
self.write_reg(0x00, (sys_cfg & 0xFFFFFFF8) | 0x03) # TRANSCEIVE
|
||||
time.sleep(0.002)
|
||||
|
||||
result = bytearray()
|
||||
pages_read = 0
|
||||
while pages_read < num_pages:
|
||||
if pages_read > 0:
|
||||
# PN5180 loses the card after each READ — must reactivate
|
||||
if self.reactivate_card() is None:
|
||||
print(f" Failed to reactivate card before page {start_page + pages_read}")
|
||||
return None
|
||||
self.write_reg(0x03, 0xFFFFFFFF) # Clear IRQs
|
||||
# IDLE → TRANSCEIVE to reset state machine
|
||||
sys_cfg = self.read_reg(0x00)
|
||||
self.write_reg(0x00, sys_cfg & 0xFFFFFFF8)
|
||||
time.sleep(0.001)
|
||||
self.write_reg(0x00, (sys_cfg & 0xFFFFFFF8) | 0x03)
|
||||
time.sleep(0.002)
|
||||
|
||||
data = self._ntag_setup_and_read_one(start_page + pages_read)
|
||||
if data is None:
|
||||
# READ command: 0x30 + page → returns 16 bytes (4 pages)
|
||||
self.send_data([0x30, start_page + pages_read])
|
||||
time.sleep(0.010)
|
||||
|
||||
rx_status = self.read_reg(0x13)
|
||||
rx_len = rx_status & 0x1FF
|
||||
if rx_len < 16:
|
||||
print(f" NTAG read page {start_page + pages_read}: rx_len={rx_len} (expected >=16)")
|
||||
return None
|
||||
|
||||
data = self.read_data(16)
|
||||
pages_to_copy = min(4, num_pages - pages_read)
|
||||
result.extend(data[: pages_to_copy * 4])
|
||||
pages_read += 4
|
||||
|
||||
Reference in New Issue