@@ -62,6 +62,7 @@ panasonic_heatpump:
uart_client_id: uart_cz_taw1
log_uart_msg: true
update_interval: 5s
uart_client_timeout: 10s
sensor:
- platform: panasonic_heatpump
@@ -110,14 +111,15 @@ climate:
## Configuration variables
- **id** (*Optional*, ID): Manually specify the ID used for actions.
- **update_interval** (*Optional*, Time): The interval of the polling request message to get the heatpump values. This time applies only if no `uart_client_id` is set. Defaults to 3s.
- **uart_id** (Optional, ID): Manually specify the UART ID of the Heatpump. Required if multiple UART buses are defined.
- **uart_client_id** (*Optional*, ID): Manually specify the UART ID of an additonal UART client like the Panasonic CZ-TAW1. If this ID is not set then your ESP controller will send the polling request messages.
- **update_interval** (*Optional*, [Time](https://esphome.io/guides/configuration-types/#time)): The interval of the polling request message to get the heatpump values. This time applies only if no `uart_client_id` is set. Defaults to 3s.
- **uart_id** (Optional, [ID](https://esphome.io/guides/configuration-types/#id)): Manually specify the UART ID of the Heatpump. Required if multiple UART buses are defined.
- **uart_client_id** (*Optional*, [ID](https://esphome.io/guides/configuration-types/#id)): Manually specify the UART ID of an additonal UART client like the Panasonic CZ-TAW1. If this ID is not set then your ESP controller will send the polling request messages.
- **log_uart_msg** (*Optional*, boolean): Shows the raw UART messages in the logs, if set to `true`. The messages will be written to the log level `INFO`. Defaults to false.
- **uart_client_timeout** (*Optional*, [Time](https://esphome.io/guides/configuration-types/#time)): Maximum idle time for the `uart_client_id` connection. If no request is sent from the UART client for this duration, the component will send a POLLING request to the heatpump. This will (hopefully) prevent the heatpump from becoming unresponsive. Defaults to `10s`.
### Sensors
All sensors are optional and all default sensor variables can be applied.
All sensors are optional and all options from [sensor component](https://esphome.io/components/sensor/) can be applied.
Here a list of all supported sensors:
```yaml
@@ -330,7 +332,7 @@ sensor:
### Binary Sensors
All binary sensors are optional and all default binary sensor variables can be applied.
All binary sensors are optional and all options from [binary sensor component](https://esphome.io/components/binary_sensor/) can be applied.
Here a list of all supported binary sensors:
```yaml
@@ -386,7 +388,7 @@ binary_sensor:
### Text Sensors
All text sensors are optional and all default text sensor variables can be applied.
All text sensors are optional and all options from [text sensor component](https://esphome.io/components/text_sensor/) can be applied.
Here a list of all supported text sensors:
```yaml
@@ -438,7 +440,7 @@ text_sensor:
### Numbers
All numbers are optional and all default number variables can be applied.
All numbers are optional and all options from [number component](https://esphome.io/components/number/) can be applied.
Additionally the options `min_value`, `max_value` and `step` can override the default limits of each set entitiy.
This is usefull for example for `set5` to `set8` if `direct temperature` is configured instead of `compensation curve` (see `top76` and `top81`).
Here a list of all supported numbers:
@@ -516,7 +518,7 @@ number:
### Switches
All switches are optional and all default switch variables can be applied.
All switches are optional and all options from [switch component](https://esphome.io/components/switch/) can be applied.
Here a list of all supported switches:
```yaml
@@ -552,7 +554,7 @@ switch:
### Selects
All selects are optional and all default select variables can be applied.
All selects are optional and all options from [select component](https://esphome.io/components/select/) can be applied.
Additionally the option `cool_mode` can be configured.
If `cool_mode` is set to `true` the entity `set9` will have the additional select options `COOL`, `COOL+TANK`, `AUTO` and `AUTO+TANK`.
Here a list of all supported selects:
@@ -579,7 +581,7 @@ select:
### Climates
All climates are optional and all default climate variables can be applied.
All climates are optional and all options from [climate component](https://esphome.io/components/climate/) can be applied.
Additionally the option `cool_mode` can be configured.
If `cool_mode` is set to `true` the entity `zone1` and `zone2` will have the additional climate modes `COOL` and `AUTO`.
Additionally the options `min_temperature`, `max_temperature` and `temperature_step` can override the default limits on each climate entitiy.