@ -37,7 +37,7 @@ GPIO4 | RX
Sometimes the desk controller does not supply enough current, then simply disconnet the VCC pin and plug in a micro-usb/usb-c cable into your ESP board.
### ESPHome yaml code
### Example ESPHome yaml code
```yaml
external_components:

View File

@ -25,7 +25,7 @@ pin | function
4 | +12V (250mA)
5 | GND
## ESPHome yaml code
## ESPHome example yaml code
```yaml
substitutions:
@ -57,26 +57,493 @@ uart:
stop_bits: 1
panasonic_heatpump:
uart_hp: uart_heatpump
uart_wm: uart_cz_taw1
id: my_heatpump
uart_id: uart_heatpump
uart_client_id: uart_cz_taw1
log_uart_msg: false
update_interval: 3s
sensor:
- platform: panasonic_heatpump
top1:
name: "Pump Flow"
...
binary_sensor:
- platform: panasonic_heatpump
top0:
name: "Heatpump State"
...
text_sensor:
- platform: panasonic_heatpump
top4:
name: "Operating Mode State"
...
number:
- platform: panasonic_heatpump
set5:
name: "Set Z1 Heat Request Temperature"
select:
- platform: panasonic_heatpump
set2:
name: "Set Holiday Mode"
switch:
- platform: panasonic_heatpump
set1:
name: "Set Heatpump"
```
## Configuration variables
- **id** (*Optional*, ID): Manually specify the ID used for actions.
- **update_interval** (*Optional*, Time): The interval of the polling request message to get the heatpump values. This time applies only if no `uart_client_id` is set. Defaults to 3s.
- **uart_id** (Optional, ID): Manually specify the UART ID of the Heatpump. Required if multiple UART buses are defined.
- **uart_client_id** (*Optional*, ID): Manually specify the UART ID of an additonal UART client like the Panasonic CZ-TAW1. If this ID is not set then your ESP controller will send the polling request messages.
- **log_uart_msg** (*Optional*, boolean): Shows the raw UART messages in the logs, if set to `true`. The messages will be written to the log level `INFO`. Defaults to false.
### Sensors
All sensors are optional and all default sensor variables can be applied.
Here a list of all supported sensors:
```
sensor:
- platform: panasonic_heatpump
top1:
name: "Pump Flow"
top5:
name: "Main Inlet Temp"
top6:
name: "Main Outlet Temp"
top7:
name: "Main Target Temp"
top8:
name: "Compressor Freq"
top9:
name: "DHW Target Temp"
top10:
name: "DHW Temp"
top11:
name: "Operations Hours"
top12:
name: "Operations Counter"
top14:
name: "Outside Temp"
top15:
name: "Heat Power Production"
top16:
name: "Heat Power Consumption"
top21:
name: "Outside Pipe Temp"
top22:
name: "DHW Heat Delta"
top23:
name: "Heat Delta"
top24:
name: "Cool Delta"
top25:
name: "DHW Holiday Shift Temp"
top27:
name: "Z1 Heat Request Temp"
top28:
name: "Z1 Cool Request Temp"
top29:
name: "Z1 Heat Curve Target High Temp"
top30:
name: "Z1 Heat Curve Target Low Temp"
top31:
name: "Z1 Heat Curve Outside High Temp"
top32:
name: "Z1 Heat Curve Outside Low Temp"
top33:
name: "Room Thermostat Temp"
top34:
name: "Z2 Heat Request Temp"
top35:
name: "Z2 Cool Request Temp"
top36:
name: "Z1 Water Temp"
top37:
name: "Z2 Water Temp"
top38:
name: "Cool Power Production"
top39:
name: "Cool Power Consumption"
top40:
name: "DHW Power Production"
top41:
name: "DHW Power Consumption"
top42:
name: "Z1 Water Target Temp"
top43:
name: "Z2 Water Target Temp"
top45:
name: "Room Holiday Shift Temp"
top46:
name: "Buffer Temp"
top47:
name: "Solar Temp"
top48:
name: "Pool Temp"
top49:
name: "Main Hex Outlet Temp"
top50:
name: "Discharge Temp"
top51:
name: "Inside Pipe Temp"
top52:
name: "Defrost Temp"
top53:
name: "Eva Outlet Temp"
top54:
name: "Bypass Outlet Temp"
top55:
name: "Ipm Temp"
top56:
name: "Z1 Temp"
top57:
name: "Z2 Temp"
top62:
name: "Fan1 Motor Speed"
top63:
name: "Fan2 Motor Speed"
top64:
name: "High Pressure"
top65:
name: "Pump Speed"
top66:
name: "Low Pressure"
top67:
name: "Compressor Current"
top70:
name: "Sterilization Temp"
top71:
name: "Sterilization Max Time"
top72:
name: "Z1 Cool Curve Target High Temp"
top73:
name: "Z1 Cool Curve Target Low Temp"
top74:
name: "Z1 Cool Curve Outside High Temp"
top75:
name: "Z1 Cool Curve Outside Low Temp"
top77:
name: "Heating Off Outdoor Temp"
top78:
name: "Heater On Outdoor Temp"
top79:
name: "Heat To Cool Temp"
top80:
name: "Cool To Heat Temp"
top82:
name: "Z2 Heat Curve Target High Temp"
top83:
name: "Z2 Heat Curve Target Low Temp"
top84:
name: "Z2 Heat Curve Outside High Temp"
top85:
name: "Z2 Heat Curve Outside Low Temp"
top86:
name: "Z2 Cool Curve Target High Temp"
top87:
name: "Z2 Cool Curve Target Low Temp"
top88:
name: "Z2 Cool Curve Outside High Temp"
top89:
name: "Z2 Cool Curve Outside Low Temp"
top90:
name: "Room Heater Operations Hours"
top91:
name: "DHW Heater Operations Hours"
top93:
name: "Pump Duty"
top95:
name: "Max Pump Duty"
top96:
name: "Heater Delay Time"
top97:
name: "Heater Start Delta"
top98:
name: "Heater Stop Delta"
top102:
name: "Solar On Delta"
top103:
name: "Solar Off Delta"
top104:
name: "Solar Frost Protection"
top105:
name: "Solar High Limit"
top113:
name: "Buffer Tank Delta"
top115:
name: "Water Pressure"
top116:
name: "Second Inlet Temp"
top117:
name: "Economizer Outlet Temp"
top118:
name: "Second Room Thermostat Temp"
top127:
name: "Z1 Valve PID"
top128:
name: "Z2 Valve PID"
top131:
name: "Bivalent Start Temperature"
top134:
name: "Bivalent Advanced Start Temp"
top135:
name: "Bivalent Advanced Stop Temp"
top136:
name: "Bivalent Advanced Start Delay"
top137:
name: "Bivalent Advanced Stop Delay"
top138:
name: "Bivalent Advanced DHW Delay"
```
### Binary Sensors
All binary sensors are optional and all default binary sensor variables can be applied.
Here a list of all supported binary sensors:
```
binary_sensor:
- platform: panasonic_heatpump
top0:
name: "Heatpump State"
top2:
name: "Force DHW State"
top3:
name: "Quiet Mode Schedule"
top13:
name: "Main Schedule State"
top26:
name: "Defrosting State"
top60:
name: "Internal Heater State"
top61:
name: "External Heater State"
top68:
name: "Force Heater State"
top69:
name: "Sterilization State"
top99:
name: "Buffer Installed"
top100:
name: "DHW Installed"
top108:
name: "Alt External Sensor"
top109:
name: "Anti Freeze Mode"
top110:
name: "Optional PCB"
top119:
name: "External Control"
top120:
name: "External Heat Cool Control"
top121:
name: "External Error Signal"
top122:
name: "External Compressor Control"
top123:
name: "Z2 Pump State"
top124:
name: "Z1 Pump State"
top129:
name: "Bivalent Control"
top132:
name: "Bivalent Advanced Heat"
top133:
name: "Bivalent Advanced DHW"
```
### Text Sensors
All text sensors are optional and all default text sensor variables can be applied.
Here a list of all supported text sensors:
```
text_sensor:
- platform: panasonic_heatpump
top4:
name: "Operating Mode State"
top17:
name: "Powerful Mode Time"
top18:
name: "Quiet Mode Level"
top19:
name: "Holiday Mode State"
top20:
name: "ThreeWay Valve State"
top44:
name: "Error"
top58:
name: "DHW Heater State"
top59:
name: "Room Heater State"
top76:
name: "Heating Mode"
top81:
name: "Cooling Mode"
top92:
name: "Heat Pump Model"
top94:
name: "Zones State"
top101:
name: "Solar Mode"
top106:
name: "Pump Flowrate Mode"
top107:
name: "Liquid Type"
top111:
name: "Z1 Sensor Settings"
top112:
name: "Z2 Sensor Settings"
top114:
name: "External Pad Heater"
top125:
name: "TwoWay Valve State"
top126:
name: "ThreeWay Valve State2"
top130:
name: "Bivalent Mode"
```
### Numbers
All numbers are optional and all default number variables can be applied.
Here a list of all supported numbers:
```
number:
- platform: panasonic_heatpump
set5:
name: "Set Z1 Heat Request Temperature"
set6:
name: "Set Z1 Cool Request Temperature"
set7:
name: "Set Z2 Heat Request Temperature"
set8:
name: "Set Z2 Cool Request Temperature"
set11:
name: "Set DHW Temp"
set15:
name: "Set Max Pump Duty"
set16_1:
name: "Set Zone1 Heat Target High"
set16_2:
name: "Set Zone1 Heat Target Low"
set16_3:
name: "Set Zone1 Heat Outside Low"
set16_4:
name: "Set Zone1 Heat Outside High"
set16_5:
name: "Set Zone2 Heat Target High"
set16_6:
name: "Set Zone2 Heat Target Low"
set16_7:
name: "Set Zone2 Heat Outside Low"
set16_8:
name: "Set Zone2 Heat Outside High"
set16_9:
name: "Set Zone1 Cool Target High"
set16_10:
name: "Set Zone1 Cool Target Low"
set16_11:
name: "Set Zone1 Cool Outside Low"
set16_12:
name: "Set Zone1 Cool Outside High"
set16_13:
name: "Set Zone2 Cool Target High"
set16_14:
name: "Set Zone2 Cool Target Low"
set16_15:
name: "Set Zone2 Cool Outside Low"
set16_16:
name: "Set Zone2 Cool Outside High"
set18:
name: "Set Floor Heat Delta"
set19:
name: "Set Floor Cool Delta"
set20:
name: "Set DHW Heat Delta"
set21:
name: "Set Heater Delay Time"
set22:
name: "Set Heater Start Delta"
set23:
name: "Set Heater Stop Delta"
set27:
name: "Set Buffer Delta"
set29:
name: "Set Heating Off Outdoor Temp"
set36:
name: "Set Bivalent Start Temp"
set37:
name: "Set Bivalent AP Start Temp"
set38:
name: "Set Bivalent AP Stop Temp"
```
### Switches
All switches are optional and all default switch variables can be applied.
Here a list of all supported switches:
```
switch:
- platform: panasonic_heatpump
set1:
name: "Set Heatpump"
set10:
name: "Set Force DHW"
set12:
name: "Set Force Defrost"
set13:
name: "Set Force Sterilization"
set14:
name: "Set Pump"
set24:
name: "Set Main Schedule"
set25:
name: "Set Alt External Sensor"
set28:
name: "Set Buffer"
set30:
name: "Set External Control"
set31:
name: "Set External Error"
set32:
name: "Set External Compressor Control"
set33:
name: "Set External Heat Cool Control"
set34:
name: "Set Bivalent Control"
```
### Selects
All selects are optional and all default select variables can be applied.
Here a list of all supported selects:
```
select:
- platform: panasonic_heatpump
set2:
name: "Set Holiday Mode"
set3:
name: "Set Quiet Mode"
set4:
name: "Set Powerful Mode"
set9:
name: "Set Operation Mode"
set17:
name: "Set Zones"
set26:
name: "Set External PadHeater"
set35:
name: "Set Bivalent Mode"
```
## Sources