@ -37,7 +37,7 @@ GPIO4 | RX
|
|||
|
||||
Sometimes the desk controller does not supply enough current, then simply disconnet the VCC pin and plug in a micro-usb/usb-c cable into your ESP board.
|
||||
|
||||
### ESPHome yaml code
|
||||
### Example ESPHome yaml code
|
||||
|
||||
```yaml
|
||||
external_components:
|
||||
|
|
|
|||
|
|
@ -25,7 +25,7 @@ pin | function
|
|||
4 | +12V (250mA)
|
||||
5 | GND
|
||||
|
||||
## ESPHome yaml code
|
||||
## ESPHome example yaml code
|
||||
|
||||
```yaml
|
||||
substitutions:
|
||||
|
|
@ -57,26 +57,493 @@ uart:
|
|||
stop_bits: 1
|
||||
|
||||
panasonic_heatpump:
|
||||
uart_hp: uart_heatpump
|
||||
uart_wm: uart_cz_taw1
|
||||
id: my_heatpump
|
||||
uart_id: uart_heatpump
|
||||
uart_client_id: uart_cz_taw1
|
||||
log_uart_msg: false
|
||||
update_interval: 3s
|
||||
|
||||
sensor:
|
||||
- platform: panasonic_heatpump
|
||||
top1:
|
||||
name: "Pump Flow"
|
||||
...
|
||||
|
||||
binary_sensor:
|
||||
- platform: panasonic_heatpump
|
||||
top0:
|
||||
name: "Heatpump State"
|
||||
...
|
||||
|
||||
text_sensor:
|
||||
- platform: panasonic_heatpump
|
||||
top4:
|
||||
name: "Operating Mode State"
|
||||
...
|
||||
|
||||
number:
|
||||
- platform: panasonic_heatpump
|
||||
set5:
|
||||
name: "Set Z1 Heat Request Temperature"
|
||||
|
||||
select:
|
||||
- platform: panasonic_heatpump
|
||||
set2:
|
||||
name: "Set Holiday Mode"
|
||||
|
||||
switch:
|
||||
- platform: panasonic_heatpump
|
||||
set1:
|
||||
name: "Set Heatpump"
|
||||
```
|
||||
|
||||
## Configuration variables
|
||||
|
||||
- **id** (*Optional*, ID): Manually specify the ID used for actions.
|
||||
- **update_interval** (*Optional*, Time): The interval of the polling request message to get the heatpump values. This time applies only if no `uart_client_id` is set. Defaults to 3s.
|
||||
- **uart_id** (Optional, ID): Manually specify the UART ID of the Heatpump. Required if multiple UART buses are defined.
|
||||
- **uart_client_id** (*Optional*, ID): Manually specify the UART ID of an additonal UART client like the Panasonic CZ-TAW1. If this ID is not set then your ESP controller will send the polling request messages.
|
||||
- **log_uart_msg** (*Optional*, boolean): Shows the raw UART messages in the logs, if set to `true`. The messages will be written to the log level `INFO`. Defaults to false.
|
||||
|
||||
### Sensors
|
||||
|
||||
All sensors are optional and all default sensor variables can be applied.
|
||||
Here a list of all supported sensors:
|
||||
|
||||
```
|
||||
sensor:
|
||||
- platform: panasonic_heatpump
|
||||
top1:
|
||||
name: "Pump Flow"
|
||||
top5:
|
||||
name: "Main Inlet Temp"
|
||||
top6:
|
||||
name: "Main Outlet Temp"
|
||||
top7:
|
||||
name: "Main Target Temp"
|
||||
top8:
|
||||
name: "Compressor Freq"
|
||||
top9:
|
||||
name: "DHW Target Temp"
|
||||
top10:
|
||||
name: "DHW Temp"
|
||||
top11:
|
||||
name: "Operations Hours"
|
||||
top12:
|
||||
name: "Operations Counter"
|
||||
top14:
|
||||
name: "Outside Temp"
|
||||
top15:
|
||||
name: "Heat Power Production"
|
||||
top16:
|
||||
name: "Heat Power Consumption"
|
||||
top21:
|
||||
name: "Outside Pipe Temp"
|
||||
top22:
|
||||
name: "DHW Heat Delta"
|
||||
top23:
|
||||
name: "Heat Delta"
|
||||
top24:
|
||||
name: "Cool Delta"
|
||||
top25:
|
||||
name: "DHW Holiday Shift Temp"
|
||||
top27:
|
||||
name: "Z1 Heat Request Temp"
|
||||
top28:
|
||||
name: "Z1 Cool Request Temp"
|
||||
top29:
|
||||
name: "Z1 Heat Curve Target High Temp"
|
||||
top30:
|
||||
name: "Z1 Heat Curve Target Low Temp"
|
||||
top31:
|
||||
name: "Z1 Heat Curve Outside High Temp"
|
||||
top32:
|
||||
name: "Z1 Heat Curve Outside Low Temp"
|
||||
top33:
|
||||
name: "Room Thermostat Temp"
|
||||
top34:
|
||||
name: "Z2 Heat Request Temp"
|
||||
top35:
|
||||
name: "Z2 Cool Request Temp"
|
||||
top36:
|
||||
name: "Z1 Water Temp"
|
||||
top37:
|
||||
name: "Z2 Water Temp"
|
||||
top38:
|
||||
name: "Cool Power Production"
|
||||
top39:
|
||||
name: "Cool Power Consumption"
|
||||
top40:
|
||||
name: "DHW Power Production"
|
||||
top41:
|
||||
name: "DHW Power Consumption"
|
||||
top42:
|
||||
name: "Z1 Water Target Temp"
|
||||
top43:
|
||||
name: "Z2 Water Target Temp"
|
||||
top45:
|
||||
name: "Room Holiday Shift Temp"
|
||||
top46:
|
||||
name: "Buffer Temp"
|
||||
top47:
|
||||
name: "Solar Temp"
|
||||
top48:
|
||||
name: "Pool Temp"
|
||||
top49:
|
||||
name: "Main Hex Outlet Temp"
|
||||
top50:
|
||||
name: "Discharge Temp"
|
||||
top51:
|
||||
name: "Inside Pipe Temp"
|
||||
top52:
|
||||
name: "Defrost Temp"
|
||||
top53:
|
||||
name: "Eva Outlet Temp"
|
||||
top54:
|
||||
name: "Bypass Outlet Temp"
|
||||
top55:
|
||||
name: "Ipm Temp"
|
||||
top56:
|
||||
name: "Z1 Temp"
|
||||
top57:
|
||||
name: "Z2 Temp"
|
||||
top62:
|
||||
name: "Fan1 Motor Speed"
|
||||
top63:
|
||||
name: "Fan2 Motor Speed"
|
||||
top64:
|
||||
name: "High Pressure"
|
||||
top65:
|
||||
name: "Pump Speed"
|
||||
top66:
|
||||
name: "Low Pressure"
|
||||
top67:
|
||||
name: "Compressor Current"
|
||||
top70:
|
||||
name: "Sterilization Temp"
|
||||
top71:
|
||||
name: "Sterilization Max Time"
|
||||
top72:
|
||||
name: "Z1 Cool Curve Target High Temp"
|
||||
top73:
|
||||
name: "Z1 Cool Curve Target Low Temp"
|
||||
top74:
|
||||
name: "Z1 Cool Curve Outside High Temp"
|
||||
top75:
|
||||
name: "Z1 Cool Curve Outside Low Temp"
|
||||
top77:
|
||||
name: "Heating Off Outdoor Temp"
|
||||
top78:
|
||||
name: "Heater On Outdoor Temp"
|
||||
top79:
|
||||
name: "Heat To Cool Temp"
|
||||
top80:
|
||||
name: "Cool To Heat Temp"
|
||||
top82:
|
||||
name: "Z2 Heat Curve Target High Temp"
|
||||
top83:
|
||||
name: "Z2 Heat Curve Target Low Temp"
|
||||
top84:
|
||||
name: "Z2 Heat Curve Outside High Temp"
|
||||
top85:
|
||||
name: "Z2 Heat Curve Outside Low Temp"
|
||||
top86:
|
||||
name: "Z2 Cool Curve Target High Temp"
|
||||
top87:
|
||||
name: "Z2 Cool Curve Target Low Temp"
|
||||
top88:
|
||||
name: "Z2 Cool Curve Outside High Temp"
|
||||
top89:
|
||||
name: "Z2 Cool Curve Outside Low Temp"
|
||||
top90:
|
||||
name: "Room Heater Operations Hours"
|
||||
top91:
|
||||
name: "DHW Heater Operations Hours"
|
||||
top93:
|
||||
name: "Pump Duty"
|
||||
top95:
|
||||
name: "Max Pump Duty"
|
||||
top96:
|
||||
name: "Heater Delay Time"
|
||||
top97:
|
||||
name: "Heater Start Delta"
|
||||
top98:
|
||||
name: "Heater Stop Delta"
|
||||
top102:
|
||||
name: "Solar On Delta"
|
||||
top103:
|
||||
name: "Solar Off Delta"
|
||||
top104:
|
||||
name: "Solar Frost Protection"
|
||||
top105:
|
||||
name: "Solar High Limit"
|
||||
top113:
|
||||
name: "Buffer Tank Delta"
|
||||
top115:
|
||||
name: "Water Pressure"
|
||||
top116:
|
||||
name: "Second Inlet Temp"
|
||||
top117:
|
||||
name: "Economizer Outlet Temp"
|
||||
top118:
|
||||
name: "Second Room Thermostat Temp"
|
||||
top127:
|
||||
name: "Z1 Valve PID"
|
||||
top128:
|
||||
name: "Z2 Valve PID"
|
||||
top131:
|
||||
name: "Bivalent Start Temperature"
|
||||
top134:
|
||||
name: "Bivalent Advanced Start Temp"
|
||||
top135:
|
||||
name: "Bivalent Advanced Stop Temp"
|
||||
top136:
|
||||
name: "Bivalent Advanced Start Delay"
|
||||
top137:
|
||||
name: "Bivalent Advanced Stop Delay"
|
||||
top138:
|
||||
name: "Bivalent Advanced DHW Delay"
|
||||
```
|
||||
|
||||
### Binary Sensors
|
||||
|
||||
All binary sensors are optional and all default binary sensor variables can be applied.
|
||||
Here a list of all supported binary sensors:
|
||||
|
||||
```
|
||||
binary_sensor:
|
||||
- platform: panasonic_heatpump
|
||||
top0:
|
||||
name: "Heatpump State"
|
||||
top2:
|
||||
name: "Force DHW State"
|
||||
top3:
|
||||
name: "Quiet Mode Schedule"
|
||||
top13:
|
||||
name: "Main Schedule State"
|
||||
top26:
|
||||
name: "Defrosting State"
|
||||
top60:
|
||||
name: "Internal Heater State"
|
||||
top61:
|
||||
name: "External Heater State"
|
||||
top68:
|
||||
name: "Force Heater State"
|
||||
top69:
|
||||
name: "Sterilization State"
|
||||
top99:
|
||||
name: "Buffer Installed"
|
||||
top100:
|
||||
name: "DHW Installed"
|
||||
top108:
|
||||
name: "Alt External Sensor"
|
||||
top109:
|
||||
name: "Anti Freeze Mode"
|
||||
top110:
|
||||
name: "Optional PCB"
|
||||
top119:
|
||||
name: "External Control"
|
||||
top120:
|
||||
name: "External Heat Cool Control"
|
||||
top121:
|
||||
name: "External Error Signal"
|
||||
top122:
|
||||
name: "External Compressor Control"
|
||||
top123:
|
||||
name: "Z2 Pump State"
|
||||
top124:
|
||||
name: "Z1 Pump State"
|
||||
top129:
|
||||
name: "Bivalent Control"
|
||||
top132:
|
||||
name: "Bivalent Advanced Heat"
|
||||
top133:
|
||||
name: "Bivalent Advanced DHW"
|
||||
```
|
||||
|
||||
### Text Sensors
|
||||
|
||||
All text sensors are optional and all default text sensor variables can be applied.
|
||||
Here a list of all supported text sensors:
|
||||
|
||||
```
|
||||
text_sensor:
|
||||
- platform: panasonic_heatpump
|
||||
top4:
|
||||
name: "Operating Mode State"
|
||||
top17:
|
||||
name: "Powerful Mode Time"
|
||||
top18:
|
||||
name: "Quiet Mode Level"
|
||||
top19:
|
||||
name: "Holiday Mode State"
|
||||
top20:
|
||||
name: "ThreeWay Valve State"
|
||||
top44:
|
||||
name: "Error"
|
||||
top58:
|
||||
name: "DHW Heater State"
|
||||
top59:
|
||||
name: "Room Heater State"
|
||||
top76:
|
||||
name: "Heating Mode"
|
||||
top81:
|
||||
name: "Cooling Mode"
|
||||
top92:
|
||||
name: "Heat Pump Model"
|
||||
top94:
|
||||
name: "Zones State"
|
||||
top101:
|
||||
name: "Solar Mode"
|
||||
top106:
|
||||
name: "Pump Flowrate Mode"
|
||||
top107:
|
||||
name: "Liquid Type"
|
||||
top111:
|
||||
name: "Z1 Sensor Settings"
|
||||
top112:
|
||||
name: "Z2 Sensor Settings"
|
||||
top114:
|
||||
name: "External Pad Heater"
|
||||
top125:
|
||||
name: "TwoWay Valve State"
|
||||
top126:
|
||||
name: "ThreeWay Valve State2"
|
||||
top130:
|
||||
name: "Bivalent Mode"
|
||||
```
|
||||
|
||||
### Numbers
|
||||
|
||||
All numbers are optional and all default number variables can be applied.
|
||||
Here a list of all supported numbers:
|
||||
|
||||
```
|
||||
number:
|
||||
- platform: panasonic_heatpump
|
||||
set5:
|
||||
name: "Set Z1 Heat Request Temperature"
|
||||
set6:
|
||||
name: "Set Z1 Cool Request Temperature"
|
||||
set7:
|
||||
name: "Set Z2 Heat Request Temperature"
|
||||
set8:
|
||||
name: "Set Z2 Cool Request Temperature"
|
||||
set11:
|
||||
name: "Set DHW Temp"
|
||||
set15:
|
||||
name: "Set Max Pump Duty"
|
||||
set16_1:
|
||||
name: "Set Zone1 Heat Target High"
|
||||
set16_2:
|
||||
name: "Set Zone1 Heat Target Low"
|
||||
set16_3:
|
||||
name: "Set Zone1 Heat Outside Low"
|
||||
set16_4:
|
||||
name: "Set Zone1 Heat Outside High"
|
||||
set16_5:
|
||||
name: "Set Zone2 Heat Target High"
|
||||
set16_6:
|
||||
name: "Set Zone2 Heat Target Low"
|
||||
set16_7:
|
||||
name: "Set Zone2 Heat Outside Low"
|
||||
set16_8:
|
||||
name: "Set Zone2 Heat Outside High"
|
||||
set16_9:
|
||||
name: "Set Zone1 Cool Target High"
|
||||
set16_10:
|
||||
name: "Set Zone1 Cool Target Low"
|
||||
set16_11:
|
||||
name: "Set Zone1 Cool Outside Low"
|
||||
set16_12:
|
||||
name: "Set Zone1 Cool Outside High"
|
||||
set16_13:
|
||||
name: "Set Zone2 Cool Target High"
|
||||
set16_14:
|
||||
name: "Set Zone2 Cool Target Low"
|
||||
set16_15:
|
||||
name: "Set Zone2 Cool Outside Low"
|
||||
set16_16:
|
||||
name: "Set Zone2 Cool Outside High"
|
||||
set18:
|
||||
name: "Set Floor Heat Delta"
|
||||
set19:
|
||||
name: "Set Floor Cool Delta"
|
||||
set20:
|
||||
name: "Set DHW Heat Delta"
|
||||
set21:
|
||||
name: "Set Heater Delay Time"
|
||||
set22:
|
||||
name: "Set Heater Start Delta"
|
||||
set23:
|
||||
name: "Set Heater Stop Delta"
|
||||
set27:
|
||||
name: "Set Buffer Delta"
|
||||
set29:
|
||||
name: "Set Heating Off Outdoor Temp"
|
||||
set36:
|
||||
name: "Set Bivalent Start Temp"
|
||||
set37:
|
||||
name: "Set Bivalent AP Start Temp"
|
||||
set38:
|
||||
name: "Set Bivalent AP Stop Temp"
|
||||
```
|
||||
|
||||
### Switches
|
||||
|
||||
All switches are optional and all default switch variables can be applied.
|
||||
Here a list of all supported switches:
|
||||
|
||||
```
|
||||
switch:
|
||||
- platform: panasonic_heatpump
|
||||
set1:
|
||||
name: "Set Heatpump"
|
||||
set10:
|
||||
name: "Set Force DHW"
|
||||
set12:
|
||||
name: "Set Force Defrost"
|
||||
set13:
|
||||
name: "Set Force Sterilization"
|
||||
set14:
|
||||
name: "Set Pump"
|
||||
set24:
|
||||
name: "Set Main Schedule"
|
||||
set25:
|
||||
name: "Set Alt External Sensor"
|
||||
set28:
|
||||
name: "Set Buffer"
|
||||
set30:
|
||||
name: "Set External Control"
|
||||
set31:
|
||||
name: "Set External Error"
|
||||
set32:
|
||||
name: "Set External Compressor Control"
|
||||
set33:
|
||||
name: "Set External Heat Cool Control"
|
||||
set34:
|
||||
name: "Set Bivalent Control"
|
||||
```
|
||||
|
||||
### Selects
|
||||
|
||||
All selects are optional and all default select variables can be applied.
|
||||
Here a list of all supported selects:
|
||||
|
||||
```
|
||||
select:
|
||||
- platform: panasonic_heatpump
|
||||
set2:
|
||||
name: "Set Holiday Mode"
|
||||
set3:
|
||||
name: "Set Quiet Mode"
|
||||
set4:
|
||||
name: "Set Powerful Mode"
|
||||
set9:
|
||||
name: "Set Operation Mode"
|
||||
set17:
|
||||
name: "Set Zones"
|
||||
set26:
|
||||
name: "Set External PadHeater"
|
||||
set35:
|
||||
name: "Set Bivalent Mode"
|
||||
```
|
||||
|
||||
## Sources
|
||||
|
|
|
|||