| loki | ||
| prometheus | ||
| README.md | ||
README.md
UniFi Infrastructure Alerts
Example Prometheus and Loki alerting rules for monitoring UniFi infrastructure with unPoller.
Overview
- Prometheus – Metrics from devices, clients, UPS/PDU, controller, sites, WAN, DHCP, rogue APs, and more
- Loki – Logs for events, alarms, IDS, anomalies, and system logs
These examples assume the default Prometheus namespace unpoller. Adjust metric names if you use a custom prometheus.namespace.
Prometheus Alerts
Place prometheus/unifi-alerts.yaml in your Prometheus rule_files or Grafana Alerting.
UPS (unifi-ups)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiUPSLowBattery | Battery level < 20% for 5m | warning | UPS needs attention; plan for charging or replacement |
| UnifiUPSCriticalBattery | Battery level < 10% for 2m | critical | UPS near depletion; prepare for shutdown |
| UnifiUPSOnBattery | Running on battery for 1m | warning | Power outage or AC loss; UPS sustaining load |
| UnifiUPSLowRuntime | Runtime < 5 min (and known) for 5m | warning | Little runtime left; prioritize critical loads |
| UnifiUPSHighLoad | Load > 80% of capacity for 10m | warning | UPS near capacity; consider load shedding |
| UnifiUPSBMSAnomaly | BMS anomaly count > 0 for 5m | warning | Battery management system issue; check UPS health |
| UnifiUPSNotCharging | Not charging and battery < 100% for 30m | warning | Battery not charging; check power or battery |
Requires: PDU/UPS devices with vbms_table (e.g. USW-DA-23-POE-UPS)
Controller (unifi-controller)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiControllerUpdateAvailable | Update available for 1h | info | Controller firmware update available |
| UnifiControllerUnsupportedDevices | Unsupported device count > 0 for 1h | warning | Devices no longer supported; plan upgrades |
Controller Health (unifi-controller-health)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiControllerRecentlyRestarted | Uptime < 1h for 5m | info | Controller recently restarted; may indicate maintenance or crash |
| UnifiControllerBackupDisabled | Auto backup disabled for 24h | info | Backups disabled; enable for disaster recovery |
Devices (unifi-devices)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiDeviceHighCPU | CPU > 90% for 10m | warning | Device under heavy load; investigate |
| UnifiDeviceHighMemory | Memory > 90% for 10m | warning | Device memory pressure; may impact performance |
| UnifiDeviceUpgradeAvailable | Firmware upgrade available for 1h | info | Device has firmware update available |
Site (unifi-site)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiSiteHighDisconnectedDevices | Disconnected devices > 0 (WLAN/WAN/LAN) for 15m | warning | Devices offline; check power, connectivity, adoption |
| UnifiSitePendingAdoptions | Pending adoptions > 0 for 1h | info | Devices awaiting adoption |
| UnifiSiteWANDrops | WAN disconnections in last 1h > 0 | warning | Internet connectivity issues |
| UnifiSiteHighLatency | Internet latency > 500ms for 10m | warning | Poor internet performance |
Requires: save_sites=true
WAN (unifi-wan)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiWANLowUptime | WAN uptime < 95% for 15m | warning | WAN link unstable; check ISP or cabling |
| UnifiWANPeakDownloadUtilization | Peak download > 90% of capacity for 10m | info | Download near capacity; consider upgrade |
| UnifiWANPeakUploadUtilization | Peak upload > 90% of capacity for 10m | info | Upload near capacity; consider upgrade |
Requires: WAN metrics (UDM/UDM-Pro/UCG)
DHCP (unifi-dhcp)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiDHCPPoolExhaustion | Pool utilization > 90% for 15m | warning | DHCP pool nearly full; expand range or reduce lease time |
| UnifiDHCPPoolCritical | Pool utilization > 98% for 5m | critical | Pool almost exhausted; new devices may not get IPs |
Requires: save_dhcp or DHCP lease collection
Rogue AP (unifi-rogue)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiRogueAPDetected | Any rogue AP detected for 5m | warning | Unauthorized access point; investigate and remediate |
Requires: save_rogue=true
Prometheus Recording Rules
Place prometheus/unifi-recording-rules.yaml in your Prometheus rule_files to pre-compute aggregates for faster dashboards and simpler alerting.
UPS Recording Rules (interval: 1m)
| Recorded Metric | Expression | Description |
|---|---|---|
unpoller:ups_on_battery:count |
Count of UPSes with battery_mode=1 by site | UPS devices running on battery per site |
unpoller:ups_min_battery_level_percent:min |
Min battery level by site | Worst battery level per site |
unpoller:ups_min_runtime_seconds:min |
Min runtime (≥0) by site | Worst runtime remaining per site |
unpoller:ups_total_power_output_watts:sum |
Sum of power output by site | Total UPS load per site |
unpoller:ups_total_power_budget_watts:sum |
Sum of power budget by site | Total UPS capacity per site |
unpoller:ups_bms_anomaly_count:sum |
Sum of devices with BMS anomaly by site | UPSes with BMS issues per site |
Device Recording Rules (interval: 1m)
| Recorded Metric | Expression | Description |
|---|---|---|
unpoller:device_count:by_type |
Count of devices by type (uap, usw, pdu, etc.) per site | Device inventory by type |
unpoller:device_count:total |
Total device count per site | Total devices per site |
unpoller:device_high_cpu_count:count |
Count of devices with CPU > 90% per site | Overloaded devices per site |
unpoller:device_high_memory_count:count |
Count of devices with memory > 90% per site | Memory-pressure devices per site |
Controller Recording Rules (interval: 5m)
| Recorded Metric | Expression | Description |
|---|---|---|
unpoller:controller_update_available:count |
Count of controllers with update available | Controllers needing updates |
unpoller:controller_unsupported_devices_total:sum |
Sum of unsupported devices | Total unsupported devices across controllers |
Loki Alerts
Place loki/unifi-alerts.yaml in your Loki Ruler config. Loki must be run with -ruler.enable=true and -ruler.storage.path configured.
Alarms (unifi-alarms)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiHighAlarmRate | > 20 alarms in 15m for 5m | warning | Elevated alarm volume; review controller |
Requires: save_alarms=true
IDS (unifi-ids)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiIDSEvent | Any IDS event in 5m for 1m | warning | Intrusion detection triggered; review logs |
| UnifiIDSHighVolume | > 50 IDS events in 1h for 5m | critical | High IDS volume; possible attack |
Requires: save_ids=true
Anomalies (unifi-anomalies)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiAnomalyDetected | > 5 anomalies in 10m for 5m | warning | Multiple anomalies; check network health |
Requires: save_anomalies=true
System Log (unifi-system-log)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiSystemLogCritical | Any CRITICAL log in 5m for 1m | critical | Critical system log; immediate attention |
| UnifiSystemLogHighSeverity | > 10 CRITICAL/HIGH/ERROR logs in 15m for 5m | warning | High volume of severe logs |
| UnifiSystemLogAuthFailure | > 5 auth failure matches in 1h for 5m | warning | Authentication failures; possible brute force |
Requires: save_syslog=true (UDM/UDM-Pro) or save_events=true (older controllers)
Events (unifi-events)
| Alert | Trigger | Severity | Description |
|---|---|---|---|
| UnifiEventSpike | > 100 events in 5m for 5m | info | Event spike; may indicate churn or issue |
Requires: save_events=true
Configuration
Prometheus (prometheus.yml):
rule_files:
- /etc/prometheus/rules/unifi-alerts.yaml
- /etc/prometheus/rules/unifi-recording-rules.yaml
Loki (loki-config.yaml):
ruler:
enable_api: true
storage:
type: local
local:
directory: /loki/rules
rule_path: /loki/rules-temp
alertmanager_url: http://alertmanager:9093
Mount the loki/ directory into your Loki container at /loki/rules/.
AlertManager Integration
Both Prometheus and Loki can forward alerts to Alertmanager. Configure Alertmanager receivers (Slack, PagerDuty, email, etc.) as needed.
Customization
- Tune thresholds (battery %, runtime seconds, CPU %, etc.) for your environment
- Add or remove labels in
annotationsfor your notification channels - Adjust
fordurations to reduce noise or catch issues sooner - Disable alert groups that don't apply (e.g. remove UPS alerts if you have no UPS devices)