The Site Speed Test poll against the controller's aggregated-dashboard
endpoint has always run unconditionally, so operators whose controllers
misbehave on that endpoint have no way to skip the request. Every other
optional collection already has a save_* flag; this adds the missing one.
Defaults to true in all three default paths (local defaults,
per-controller defaults and remote discovery) so existing setups keep
behaving exactly as before.
Refs #1030
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Adds 21 new data types from unifi v5.26.0 across all metric output plugins
(InfluxDB, Prometheus, DataDog). Per-site Integration/v1 calls are gated on
API key configuration and only run for user-configured sites; ErrEndpointNotFound
is handled gracefully so older firmware continues to work without log spam.
Also migrates events collection (collectAlarms, collectAnomalies, collectEvents,
collectIDs, collectProtectLogs) to handle Network 10.x+ endpoint removals via
ErrEndpointNotFound, with debug-level logging to avoid per-poll noise.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
* feat: add Site Magic site-to-site VPN metrics (closes#926)
Bump github.com/unpoller/unifi/v5 to v5.25.0 which adds:
- GetMagicSiteToSiteVPN / GetMagicSiteToSiteVPNSite API methods
- MagicSiteToSiteVPN types with mesh, connection, device, and status structs
- Missing VPN health fields on Site.Health (SiteToSiteNumActive/Inactive,
SiteToSiteRxBytes/TxBytes/RxPackets/TxPackets)
Implement VPN metrics collection across all output plugins:
- Collect Site Magic VPN mesh data per-site in inputunifi pollController
- Propagate VPNMeshes through poller.Metrics / AppendMetrics
- Apply DefaultSiteNameOverride for VPN meshes in augmentMetrics /
applySiteNameOverride
- influxunifi: vpn_mesh, vpn_mesh_connection, vpn_mesh_status tables
- promunifi: vpn_mesh_*, vpn_tunnel_*, vpn_mesh_status_* gauges
- datadogunifi: unifi.vpn_mesh.*, unifi.vpn_tunnel.*, unifi.vpn_mesh_status.*
Co-Authored-By: Claude Sonnet 4.6 (1M context) <noreply@anthropic.com>
* feat(otelunifi): add Site Magic VPN metrics to OpenTelemetry output
Adds exportVPNMeshes to the otel output plugin, emitting the same
unifi_vpn_mesh_*, unifi_vpn_tunnel_*, and unifi_vpn_mesh_status_*
gauges as the other output plugins.
Co-Authored-By: Claude Sonnet 4.6 (1M context) <noreply@anthropic.com>
---------
Co-authored-by: Claude Sonnet 4.6 (1M context) <noreply@anthropic.com>
Collect port anomalies from the UniFi v2 API endpoint
/proxy/network/v2/api/site/{site}/ports/port-anomalies and export
them to all output plugins (Prometheus, InfluxDB, DataDog, OpenTelemetry).
Metrics exported per port:
- port_anomaly_count – number of anomaly events
- port_anomaly_last_seen – unix timestamp of last event
Labels: site_name, source, device_mac, port_idx, anomaly_type
Bumps github.com/unpoller/unifi/v5 to v5.24.0 which adds GetPortAnomalies.
Co-authored-by: Claude Sonnet 4.6 (1M context) <noreply@anthropic.com>
Bumps github.com/unpoller/unifi/v5 to v5.23.0 which adds
GetTopology() fetching vertices (devices/clients) and edges
(wired/wireless connections) from /proxy/network/v2/api/site/{site}/topology.
Changes across the stack:
- poller.Metrics: add Topologies []any field + AppendMetrics support
- inputunifi: collect topology per-site (non-fatal on older controllers),
pass through augmentMetrics with site name override support
- promunifi: new topology.go with summary, connection-type, link-quality,
and band-distribution gauges
- influxunifi: new topology.go with topology_summary and topology_edge
measurements
- datadogunifi: new topology.go with equivalent Datadog gauges
- otelunifi: new topology.go with OpenTelemetry gauge observations
Co-authored-by: Claude Sonnet 4.6 (1M context) <noreply@anthropic.com>
* fix(influxunifi): use CelsiusSafe() for temp fields to fix InfluxDB type conflict
Write temp_* fields as float64 instead of int64 so InfluxDB does not
report 'field type conflict' when the measurement already has float.
Requires github.com/unpoller/unifi/v5 with CelsiusSafe() (unpoller/unifi#195).
Fixes#944.
Co-authored-by: Cursor <cursoragent@cursor.com>
* deps: unifi v5.17.0; nil guards and 429 retry (unpoller#943)
- Bump github.com/unpoller/unifi/v5 to v5.17.0 (CelsiusSafe, ErrNilUnifi, RateLimitError)
- inputunifi: guard pollController for nil c.Unifi; controllerID(c) in formatSites/Clients/Devices
- inputunifi: getUnifi retry with backoff on 429 (up to 5 attempts, Retry-After or exponential backoff)
Co-authored-by: Cursor <cursoragent@cursor.com>
* test(influxunifi): expect temp_* as float after CelsiusSafe() (fix#944)
Co-authored-by: Cursor <cursoragent@cursor.com>
---------
Co-authored-by: Cursor <cursoragent@cursor.com>
- Add Sysinfo collection from stat/sysinfo endpoint
- Export controller_info, uptime, update_available, data retention, ports
- Hostname fallback: name, then site_name when API omits hostname
- Apply site name override to Sysinfo for remote/cloud
- Add Discover/Discoverer for endpoint discovery
- Require unpoller/unifi v5.15.0
Co-authored-by: Cursor <cursoragent@cursor.com>
- Update go.mod to use unifi library v5.6.0 (includes remote API support)
- Remove temporary replace directive now that v5.6.0 is published
- Fix empty-block linter errors in input.go by removing empty if blocks
Remove empty if blocks by inverting conditions:
- Line 289: Invert Remote check for URL default
- Line 303: Invert APIKey check in Remote mode
- Line 401: Invert Remote check for URL default in setControllerDefaults
- Add remote API mode with automatic controller discovery
- Discover consoles via /v1/hosts endpoint
- Auto-discover sites for each console via integration API
- Use console name from hosts response as site name override for Cloud Gateways
- Support both config-level and per-controller remote mode
- Add example configs for YAML, JSON, and TOML formats
- Remote API uses api.ui.com with X-API-Key authentication
- Automatically discovers all consoles when remote=true and remote_api_key is set
This enables monitoring multiple UniFi Cloud Gateways through a single
API key without requiring direct network access to each controller.
The UniFi controller HTTP client was created without a timeout, causing
unpoller to hang indefinitely when the controller becomes unresponsive.
This resulted in random stops where polling would cease until the
container was restarted.
Changes:
- Add Timeout field to Controller struct (cnfg.Duration)
- Set default timeout of 60 seconds
- Pass timeout to unifi.Config when creating the client
- Log timeout value on startup for visibility
The timeout can be configured via:
- Config file: timeout = "60s"
- Environment: UP_UNIFI_DEFAULT_TIMEOUT=60s
Fixes issue where container would hang overnight:
2025/12/22 22:29:27 - Requesting https://unifi/.../stat/sta
[~2 hour gap - request hung indefinitely]
2025/12/23 00:17:57 - Unmarshalling Device Type: udm...
- Add SaveProtectLogs config option to enable Protect log collection
- Add ProtectThumbnails config option to fetch event thumbnails
- Add collectProtectLogs function with 24h default fetch window
- Add ProtectLogEvent for Loki reporting with separate thumbnail log lines
- Add PII redaction for Protect log entries
- Filter thumbnail fetching to camera events only (motion, smartDetect*, etc.)
- Update log output to show Protect logs status
Add new save_syslog config option to collect events from the v2 UniFi
system-log API (/v2/api/site/{site}/system-log/all).
Changes:
- Add SaveSyslog field to Controller struct
- Add collectSyslog() function using v2 API
- Keep collectEvents() using v1 API for backwards compatibility
- Add RedactIPPII() helper for PII redaction
- Update lokiunifi to log raw JSON (parseable with Loki | json)
- Reduce indexed labels to low-cardinality fields only
- Add SystemLogEntry handler in lokiunifi report
Config: save_syslog (v2 API) vs save_events (v1 API)
Env: UP_UNIFI_DEFAULT_SAVE_SYSLOG=true
Speed tests were not being reported correctly for multi-WAN setups
because the device-level speedtest-status field was returning zeros.
The data has moved to a new aggregated dashboard API endpoint.
Changes:
- Add GetSpeedTests() and GetSiteSpeedTests() methods to fetch from
/v2/api/site/{site}/aggregated-dashboard endpoint
- Create SpeedTestResult data structures to capture per-WAN metrics
- Update Prometheus exporter with new speedtest_* metrics per interface
- Update InfluxDB exporter to write speedtest measurements per WAN
- Update Datadog exporter with unifi.speedtest.* metrics per WAN
- Update metrics collection to include speed test data for all sites
Metrics now include labels/tags for:
- wan_interface: Physical interface (eth8, eth9, etc.)
- wan_group: Logical WAN name (WAN, WAN2, etc.)
- site_name: Site identifier
- source: Controller URL
Gracefully handles older controllers without the new API endpoint.
Fixes#841🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>