A 1-bit switch is domain-agnostic, yet DPT 1.001 defaulted to 'lighting', so an "AC on/off" was classified lighting and tripped downstream checks. The domain is now a combination: explicit name > strong domain-encoding DPT > main-group name; a bare 1-bit GA with no signal is honestly 'unknown', never a guessed lighting. An explicit name contradicting a STRONG DPT yields 'unknown' (a genuine conflict, shown by explain_ga as contested), not a silent pick. Word-boundary matching so "ac" no longer fires inside "terrace"; name terms broadened (EN+RU HVAC incl. ac/a-c/air-conditioner, RGB/colour lighting). check_policy taxonomy-outlier now flags only misplaced ACTUATORS (lighting/ shutter/hvac); sensors, scene links, thresholds and timeout params are the cross-cutting GAs they are. HA generator still emits a switch for a now-HVAC simple on/off, so no device is dropped. Verified on 3 real projects: every AC on/off is HVAC; outlier noise fell demo 11->2, Minsk 31->6, Razdory 200->57. tests/test_domain_classifier.py (13/13 green). Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>