Design-time MCP server that reads .knxproj (read-only), validates naming/DPT/status, and generates Home Assistant KNX YAML + ETS-importable group addresses (XML/CSV). No live bus access — confined-workspace writes only. Includes: 12 MCP tools, end-to-end smoke test, MIT license, English-first README (+ Russian), CONTRIBUTING with a real-project test call, SECURITY policy, CHANGELOG, GitHub Actions CI (Python 3.10–3.12), and issue/PR templates. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
124 lines
9.0 KiB
Python
124 lines
9.0 KiB
Python
"""DPT classification and Home Assistant KNX platform mapping.
|
|
|
|
Central knowledge base translating a KNX Datapoint Type into:
|
|
* a functional *category* (lighting / shutter / hvac / sensor / scene / energy / diagnostics)
|
|
* a *kind* (command vs status vs sensor)
|
|
* a suggested Home Assistant KNX platform + value_type
|
|
|
|
Everything here is heuristic but conservative: when in doubt we mark the
|
|
datapoint for manual review rather than guessing an entity wrong.
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
from typing import Optional, TypedDict
|
|
|
|
|
|
class DptInfo(TypedDict):
|
|
category: str # lighting|shutter|hvac|sensor|scene|energy|diagnostics|unknown
|
|
kind: str # command|status|sensor|unknown
|
|
ha_platform: str # switch|light|cover|sensor|binary_sensor|climate|number|scene|button|unknown
|
|
value_type: Optional[str] # HA value_type for sensor/number, None otherwise
|
|
label: str # human-readable description
|
|
|
|
|
|
CATEGORY_LIGHTING = "lighting"
|
|
CATEGORY_SHUTTER = "shutter"
|
|
CATEGORY_HVAC = "hvac"
|
|
CATEGORY_SENSOR = "sensor"
|
|
CATEGORY_SCENE = "scene"
|
|
CATEGORY_ENERGY = "energy"
|
|
CATEGORY_DIAG = "diagnostics"
|
|
CATEGORY_UNKNOWN = "unknown"
|
|
|
|
KIND_COMMAND = "command"
|
|
KIND_STATUS = "status"
|
|
KIND_SENSOR = "sensor"
|
|
KIND_UNKNOWN = "unknown"
|
|
|
|
|
|
def dpt_key(main: Optional[int], sub: Optional[int]) -> str:
|
|
"""Return a normalized 'main.sub' / 'main' string, '' if no DPT."""
|
|
if main is None:
|
|
return ""
|
|
if sub is None:
|
|
return str(main)
|
|
return f"{main}.{sub:03d}"
|
|
|
|
|
|
def dpt_ets_token(main: Optional[int], sub: Optional[int]) -> str:
|
|
"""ETS GA-export 'DPTs' attribute token, e.g. DPST-1-1 or DPT-1."""
|
|
if main is None:
|
|
return ""
|
|
if sub is None:
|
|
return f"DPT-{main}"
|
|
return f"DPST-{main}-{sub}"
|
|
|
|
|
|
# Exact (main, sub) overrides. None sub = applies to whole main group as fallback.
|
|
_EXACT: dict[tuple[int, Optional[int]], DptInfo] = {
|
|
(1, 1): {"category": CATEGORY_LIGHTING, "kind": KIND_COMMAND, "ha_platform": "switch", "value_type": None, "label": "Switch on/off"},
|
|
(1, 2): {"category": CATEGORY_UNKNOWN, "kind": KIND_COMMAND, "ha_platform": "switch", "value_type": None, "label": "Boolean"},
|
|
(1, 3): {"category": CATEGORY_UNKNOWN, "kind": KIND_COMMAND, "ha_platform": "switch", "value_type": None, "label": "Enable"},
|
|
(1, 5): {"category": CATEGORY_DIAG, "kind": KIND_SENSOR, "ha_platform": "binary_sensor", "value_type": None, "label": "Alarm"},
|
|
(1, 8): {"category": CATEGORY_SHUTTER, "kind": KIND_COMMAND, "ha_platform": "cover", "value_type": None, "label": "Up/Down"},
|
|
(1, 9): {"category": CATEGORY_UNKNOWN, "kind": KIND_SENSOR, "ha_platform": "binary_sensor", "value_type": None, "label": "Open/Close"},
|
|
(1, 10): {"category": CATEGORY_SHUTTER, "kind": KIND_COMMAND, "ha_platform": "cover", "value_type": None, "label": "Start/Stop"},
|
|
(1, 11): {"category": CATEGORY_LIGHTING, "kind": KIND_STATUS, "ha_platform": "binary_sensor", "value_type": None, "label": "State (status)"},
|
|
(1, 18): {"category": CATEGORY_DIAG, "kind": KIND_SENSOR, "ha_platform": "binary_sensor", "value_type": None, "label": "Occupancy"},
|
|
(1, 19): {"category": CATEGORY_DIAG, "kind": KIND_SENSOR, "ha_platform": "binary_sensor", "value_type": None, "label": "Window/Door"},
|
|
(3, 7): {"category": CATEGORY_LIGHTING, "kind": KIND_COMMAND, "ha_platform": "light", "value_type": None, "label": "Dimming control (relative)"},
|
|
(3, 8): {"category": CATEGORY_SHUTTER, "kind": KIND_COMMAND, "ha_platform": "cover", "value_type": None, "label": "Blinds control (relative)"},
|
|
(5, 1): {"category": CATEGORY_LIGHTING, "kind": KIND_COMMAND, "ha_platform": "light", "value_type": "percent", "label": "Scaling 0-100% (brightness/position)"},
|
|
(5, 3): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "angle", "label": "Angle 0-360°"},
|
|
(5, 10): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "pulse", "label": "Counter pulses"},
|
|
(7, 12): {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "electric_current", "label": "Current (mA)"},
|
|
(7, 13): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "illuminance", "label": "Brightness (lux)"},
|
|
(9, 1): {"category": CATEGORY_HVAC, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "temperature", "label": "Temperature (°C)"},
|
|
(9, 4): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "illuminance", "label": "Illuminance (lux)"},
|
|
(9, 5): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "wind_speed_ms", "label": "Wind speed (m/s)"},
|
|
(9, 7): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "humidity", "label": "Humidity (%)"},
|
|
(9, 8): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "ppm", "label": "Air quality (ppm)"},
|
|
(9, 20): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "voltage", "label": "Voltage (mV)"},
|
|
(9, 21): {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "current", "label": "Current (mA)"},
|
|
(12, 1): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "pulse_4_byte", "label": "Counter (4-byte unsigned)"},
|
|
(13, 10): {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "active_energy", "label": "Active energy (Wh)"},
|
|
(13, 13): {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "active_energy_kwh", "label": "Active energy (kWh)"},
|
|
(14, 19): {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "electric_current", "label": "Electric current (A)"},
|
|
(14, 27): {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "temperature", "label": "Temperature (K → °C)"},
|
|
(14, 56): {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "power", "label": "Power (W)"},
|
|
(17, 1): {"category": CATEGORY_SCENE, "kind": KIND_COMMAND, "ha_platform": "scene", "value_type": None, "label": "Scene number"},
|
|
(18, 1): {"category": CATEGORY_SCENE, "kind": KIND_COMMAND, "ha_platform": "scene", "value_type": None, "label": "Scene control"},
|
|
(20, 102): {"category": CATEGORY_HVAC, "kind": KIND_COMMAND, "ha_platform": "climate", "value_type": None, "label": "HVAC mode"},
|
|
}
|
|
|
|
# Whole-main-group fallbacks when an exact (main, sub) is not known.
|
|
_MAIN_FALLBACK: dict[int, DptInfo] = {
|
|
1: {"category": CATEGORY_UNKNOWN, "kind": KIND_COMMAND, "ha_platform": "switch", "value_type": None, "label": "1-bit boolean"},
|
|
3: {"category": CATEGORY_LIGHTING, "kind": KIND_COMMAND, "ha_platform": "light", "value_type": None, "label": "4-bit relative control"},
|
|
5: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "1byte_unsigned", "label": "1-byte unsigned"},
|
|
6: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "1byte_signed", "label": "1-byte signed"},
|
|
7: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "2byte_unsigned", "label": "2-byte unsigned"},
|
|
8: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "2byte_signed", "label": "2-byte signed"},
|
|
9: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "2byte_float", "label": "2-byte float"},
|
|
12: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "4byte_unsigned", "label": "4-byte unsigned"},
|
|
13: {"category": CATEGORY_ENERGY, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "4byte_signed", "label": "4-byte signed"},
|
|
14: {"category": CATEGORY_SENSOR, "kind": KIND_SENSOR, "ha_platform": "sensor", "value_type": "4byte_float", "label": "4-byte float"},
|
|
17: {"category": CATEGORY_SCENE, "kind": KIND_COMMAND, "ha_platform": "scene", "value_type": None, "label": "Scene number"},
|
|
18: {"category": CATEGORY_SCENE, "kind": KIND_COMMAND, "ha_platform": "scene", "value_type": None, "label": "Scene control"},
|
|
20: {"category": CATEGORY_HVAC, "kind": KIND_COMMAND, "ha_platform": "climate", "value_type": None, "label": "1-byte HVAC enum"},
|
|
}
|
|
|
|
|
|
def classify_dpt(main: Optional[int], sub: Optional[int]) -> DptInfo:
|
|
"""Classify a DPT into category / kind / HA platform."""
|
|
if main is None:
|
|
return {"category": CATEGORY_UNKNOWN, "kind": KIND_UNKNOWN,
|
|
"ha_platform": "unknown", "value_type": None, "label": "No DPT assigned"}
|
|
if (main, sub) in _EXACT:
|
|
return dict(_EXACT[(main, sub)]) # copy
|
|
if main in _MAIN_FALLBACK:
|
|
return dict(_MAIN_FALLBACK[main])
|
|
return {"category": CATEGORY_UNKNOWN, "kind": KIND_UNKNOWN,
|
|
"ha_platform": "unknown", "value_type": None, "label": f"DPT {main}"}
|