Found on a real 1312-GA house: a room with floor heating, a convector and an AC unit became
ONE climate (convector setpoint, AC controller mode, AC fan speed as the valve). Room 1.09
matched 2.09 and a central "09." GA, "Kids room 1" took "Kids room 2 temperature", and valves
came from light brightness and blind position statuses. The zone was the room alone: device
words were stripped as qualifiers, "А/С" vanishes in the tokenizer, the floor digit of "1.09"
is dropped.
Now a climate is assembled per room AND device type (floor, wall, radiator/convector, fan
coil, AC; RU/EN/DE words, removed from the zone as whole words):
- room code "N.NN" only at the start of a name, and it must match on both sides;
- standalone numbers of the anchor must be in a device member; a shared room sensor's
numbers must be among the anchor's; digits in dotted codes and values do not count;
- an untyped GA is shared room data: any role if the room has one device, otherwise only
the current temperature, which several devices may reuse; with a room code the room's
untyped sensor qualifies even without the device's extra words;
- a word that sets another device of the room apart keeps its GAs away;
- control roles must be unambiguous: more than one candidate -> review climate_ambiguous;
- two mode GAs that cannot be told apart -> review climate_duplicate_anchor, not dropped;
- only 20.102 / 20.105 anchor; valve needs a valve word; AC never gets a valve;
- stable address order, so results never depend on parse order.
Two gates. Own audit on seven real projects, every changed entity inspected: no control GA
used by two climates, no address lost; house 16 -> 33 climates (one per device), manual
review 33 -> 12; flat 7 -> 9; HDL 3 -> 5; demo 6 -> 13; villa 23 -> 21 with the 3 it cannot
disambiguate sent to review instead of guessed. LLM council (three models + devil's
advocate, sanitised packet): accept with hardening; its P0s (same-type devices, silent
first pick) and P1s (mid-name codes, dotted digits, non-102/105 anchors, generic valve
words) are all in this commit, with tests E and F covering its failure catalogue.
Out of scope, recorded: identically named rooms of different flats without room codes, and
lexical identity in general -> device-channel identity ("lever 0").
Also works around a mypy 2.3.1 parse error on a comment right after a compound if.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
229 lines
13 KiB
Python
229 lines
13 KiB
Python
"""Regressions found on a real 1312-GA Zennio house (ETS 5.7), anonymised.
|
||
|
||
A. subdpt_suspect false positives
|
||
- a 1-bit flag named after a quantity ("on by motion detector by illuminance",
|
||
"CO2 threshold 1") is a flag, not the value -> never checked;
|
||
- date/time and text GAs are never checked ("meter value recorded, date");
|
||
- legitimate DPTs for the same quantity are not "wrong": power 9.024 kW,
|
||
power factor 14.057, reactive energy 13.015, power 14.056 under an
|
||
"electricity" name. (Checked against xknx 3.20.)
|
||
- real findings survive: a bare DPT 9 named "lux threshold", a 5.x named
|
||
"temperature control".
|
||
B. on/off lighting (1.001, lighting category) is emitted as a Home Assistant light
|
||
(address + state_address), not a switch. A brightness-only light, which HA would
|
||
reject for lacking `address`, goes to review (tested in test_pipeline.py).
|
||
"""
|
||
import os
|
||
import sys
|
||
|
||
sys.path.insert(0, os.path.join(os.path.dirname(__file__), ".."))
|
||
|
||
from nickol_knx_mcp.project import build_loaded_from_raw
|
||
from nickol_knx_mcp.analyze import detect_dpt_issues
|
||
|
||
|
||
def _ga(addr, name, main, sub):
|
||
return {"name": name, "identifier": f"GA-{addr}", "raw_address": 0, "address": addr,
|
||
"project_uid": None, "dpt": {"main": main, "sub": sub} if main else None,
|
||
"data_secure": False, "communication_object_ids": [], "description": "", "comment": ""}
|
||
|
||
|
||
def _project(rows):
|
||
return build_loaded_from_raw({"group_addresses": {a: _ga(a, n, m, s) for a, n, m, s in rows},
|
||
"info": {"group_address_style": "ThreeLevel"}}, "mem")
|
||
|
||
|
||
# ---------------------------------------------------------------- A. subdpt_suspect
|
||
false_positives = [
|
||
("1/7/63", "1.04 - Winter garden - on by motion by освещенности", 1, 6),
|
||
("1/7/70", "1.01 - Vestibule вкл по ДД по освещенности", 1, 2),
|
||
("6/0/3", "Опорный сигнал освещенности для дневного откл ДД", 1, 1),
|
||
("2/5/1", "02. Living - порог CO2 1", 1, 1),
|
||
("5/2/1", "Электроэнергия - запись значения, дата", 11, 1),
|
||
("5/2/8", "3 Фазы - Активная мощность, кВт", 9, 24),
|
||
("5/2/9", "Boiler produced мощность", 9, 24),
|
||
("5/2/10", "3 Фазы - Фактор мощности", 14, 57),
|
||
("5/2/13", "3 Фазы - Индуктивная реактивная энергия", 13, 15),
|
||
("5/2/20", "Электроэнергия - Текущее потребление, W", 14, 56),
|
||
("5/2/21", "Meter energy MWh", 13, 16),
|
||
]
|
||
real_findings = [
|
||
("1/5/1", "01. Corridor PDK1.1 - порог освещенности, люкс", 9, None),
|
||
("3/1/1", "ПВУ 1 - Контроль температуры", 5, None),
|
||
("5/2/30", "Phase power L1", 5, 1),
|
||
("5/2/31", "Room temperature", 9, 2),
|
||
]
|
||
p = _project(false_positives + real_findings)
|
||
flagged = {f["address"] for f in detect_dpt_issues(p) if f["code"] == "subdpt_suspect"}
|
||
wrong = [a for a, *_ in false_positives if a in flagged]
|
||
assert not wrong, f"false positives still flagged: {wrong}"
|
||
missed = [a for a, *_ in real_findings if a not in flagged]
|
||
assert not missed, f"real findings no longer flagged: {missed}"
|
||
print(f"OK: A — {len(false_positives)} false positives silent, {len(real_findings)} real findings still flagged")
|
||
|
||
# ---------------------------------------------------------------- B. on/off lighting -> light
|
||
import yaml
|
||
from nickol_knx_mcp.generate_ha import generate_ha_yaml
|
||
|
||
pB = _project([
|
||
("1/0/1", "1.05 Bedroom - Ceiling light - on/off", 1, 1),
|
||
("1/1/1", "1.05 Bedroom - Ceiling light - on/off status", 1, 11),
|
||
("5/0/1", "Garden pump - on/off", 1, 1),
|
||
])
|
||
knxB = yaml.safe_load(generate_ha_yaml(pB)["yaml"].split("\n\n", 1)[1])["knx"]
|
||
lightsB = {l["address"]: l for l in knxB.get("light", [])}
|
||
assert "1/0/1" in lightsB and lightsB["1/0/1"].get("state_address") == "1/1/1", knxB
|
||
assert not any(s["address"] == "1/0/1" for s in knxB.get("switch", [])), knxB
|
||
print("OK: B — on/off lighting is a light with address + state_address, not a switch")
|
||
|
||
# ---------------------------------------------------------------- C. self-reporting status
|
||
def _proj_with_cos(rows, flags_by_addr):
|
||
gas, cos = {}, {}
|
||
for a, n, m, s in rows:
|
||
g = _ga(a, n, m, s)
|
||
if a in flags_by_addr:
|
||
cid = f"CO-{a}"
|
||
g["communication_object_ids"] = [cid]
|
||
cos[cid] = {"flags": flags_by_addr[a], "group_address_links": [a], "dpts": [], "text": "", "function_text": ""}
|
||
gas[a] = g
|
||
return build_loaded_from_raw({"group_addresses": gas, "communication_objects": cos,
|
||
"info": {"group_address_style": "ThreeLevel"}}, "mem")
|
||
|
||
pC = _proj_with_cos(
|
||
[("1/0/5", "1.02 Hall - Ceiling light - on/off", 1, 1),
|
||
("1/0/6", "1.03 Living - Floor lamp light - on/off", 1, 1),
|
||
("5/0/5", "Workshop socket - on/off", 1, 1)],
|
||
{"1/0/5": {"write": True, "read": True, "transmit": True},
|
||
"1/0/6": {"write": True, "read": False, "transmit": False},
|
||
"5/0/5": {"write": True, "read": True, "transmit": True}})
|
||
resC = generate_ha_yaml(pC)
|
||
knxC = yaml.safe_load(resC["yaml"].split("\n\n", 1)[1])["knx"]
|
||
ents = {e["address"]: e for plat in ("light", "switch") for e in knxC.get(plat, [])}
|
||
assert ents["1/0/5"].get("state_address") == "1/0/5", ents
|
||
assert ents["5/0/5"].get("state_address") == "5/0/5", ents
|
||
assert "state_address" not in ents["1/0/6"], ents
|
||
no_status = {r["address"] for r in resC["review"] if r["reason"] in ("light_without_status", "switch_without_status")}
|
||
assert no_status == {"1/0/6"}, no_status
|
||
print("OK: C — Read+Transmit object on the command GA is its own state; write-only stays in review")
|
||
|
||
# ---------------------------------------------------------------- E. climate: one entity per device
|
||
# A room with floor heating + convector + AC unit sharing one air sensor used to become ONE climate
|
||
# (convector setpoint, AC controller mode, AC fan speed as "valve"). Room codes lost their floor
|
||
# digit (1.09 matched 2.09 and a central GA), and "Kids room 1" matched "Kids room 2".
|
||
pE = _project([
|
||
("2/0/6", "1.05 Bedroom - Air temperature", 9, 1),
|
||
("2/2/20", "1.05 Bedroom - Convector - Уставка", 9, 1),
|
||
("2/2/21", "1.05 Bedroom - Convector - Уставка - Статус", 9, 1),
|
||
("2/2/22", "1.05 Bedroom - Convector - Режим", 20, 102),
|
||
("2/2/23", "1.05 Bedroom - Convector - Режим - Статус", 20, 102),
|
||
("2/5/37", "1.05 Bedroom -А/С - Уставка", 9, 1),
|
||
("2/5/38", "1.05 Bedroom -А/С - Уставка - Статус", 9, 1),
|
||
("2/5/39", "1.05 Bedroom -А/С - Режим", 20, 105),
|
||
("2/5/40", "1.05 Bedroom -А/С - Режим - Статус", 20, 105),
|
||
("2/5/42", "1.05 Bedroom -А/С - Вентилятор - Статус", 5, 1),
|
||
("2/4/10", "1.09 Bath - Теплый пол - Уставка", 9, 1),
|
||
("2/4/11", "1.09 Bath - Теплый пол - Уставка - Статус", 9, 1),
|
||
("2/4/12", "1.09 Bath - Теплый пол - Режим", 20, 102),
|
||
("2/4/13", "1.09 Bath - Теплый пол - Режим - Статус", 20, 102),
|
||
("2/1/9", "1.09 Bath - Теплый пол - Температура", 9, 1),
|
||
("2/4/14", "1.09 Bath - Теплый пол - клапан - Статус", 5, 1),
|
||
("0/1/7", "09. Bath 1st floor ТП + стена - Уставка", 9, 1),
|
||
("2/3/0", "2.09 Lounge - Теплый пол - Уставка", 9, 1),
|
||
("2/3/1", "2.09 Lounge - Теплый пол - Уставка - Статус", 9, 1),
|
||
("2/3/2", "2.09 Lounge - Теплый пол - Режим", 20, 102),
|
||
("2/1/19", "2.09 Lounge - Теплый пол - Температура", 9, 1),
|
||
("3/0/1", "Kids room 1 temperature", 9, 1),
|
||
("3/0/2", "Kids room 2 temperature", 9, 1),
|
||
("3/1/1", "Kids room 1 AC setpoint", 9, 1),
|
||
("3/1/2", "Kids room 1 AC setpoint status", 9, 1),
|
||
("3/1/3", "Kids room 1 AC mode", 20, 102),
|
||
])
|
||
climE = yaml.safe_load(generate_ha_yaml(pE)["yaml"].split("\n\n", 1)[1])["knx"]["climate"]
|
||
by_mode = {(e.get("operation_mode_address") or e.get("controller_mode_address")): e for e in climE}
|
||
conv, ac, bath, lounge, kids = by_mode["2/2/22"], by_mode["2/5/39"], by_mode["2/4/12"], by_mode["2/3/2"], by_mode["3/1/3"]
|
||
assert conv["target_temperature_state_address"] == "2/2/21" and conv["temperature_address"] == "2/0/6", conv
|
||
assert "controller_mode_address" not in conv and "command_value_state_address" not in conv, conv
|
||
assert ac["target_temperature_state_address"] == "2/5/38" and ac["temperature_address"] == "2/0/6", ac
|
||
assert "command_value_state_address" not in ac and "operation_mode_address" not in ac, ac
|
||
assert bath["target_temperature_address"] == "2/4/10" and bath["temperature_address"] == "2/1/9", bath
|
||
assert bath.get("command_value_state_address") == "2/4/14", bath
|
||
assert lounge["target_temperature_state_address"] == "2/3/1" and lounge["temperature_address"] == "2/1/19", lounge
|
||
assert kids["temperature_address"] == "3/0/1", kids
|
||
controls = [e[k] for e in climE for k in e if k.endswith("address") and k != "temperature_address"]
|
||
assert len(controls) == len(set(controls)), controls
|
||
assert "0/1/7" not in controls, controls
|
||
print(f"OK: E — {len(climE)} climates, one per device; room code, numbers and device type keep them apart")
|
||
|
||
# ---------------------------------------------------------------- F. climate: LLM-council failure catalog
|
||
def _climates(rows):
|
||
res = generate_ha_yaml(_project(rows))
|
||
doc = yaml.safe_load(res["yaml"].split("\n\n", 1)[1]) or {}
|
||
return (doc.get("knx") or {}).get("climate", []), res["review"]
|
||
|
||
def _controls(clims):
|
||
return [e[k] for e in clims for k in e if k.endswith("address") and k != "temperature_address"]
|
||
|
||
# F1. two devices of the same type, told apart by a word -> two climates, no cross-wiring
|
||
cl, rv = _climates([
|
||
("4/0/1", "3.01 Hall - Air temperature", 9, 1),
|
||
("4/1/1", "3.01 Hall - Convector north - Setpoint", 9, 1),
|
||
("4/1/2", "3.01 Hall - Convector north - Setpoint status", 9, 1),
|
||
("4/1/3", "3.01 Hall - Convector north - HVAC mode", 20, 102),
|
||
("4/2/1", "3.01 Hall - Convector south - Setpoint", 9, 1),
|
||
("4/2/2", "3.01 Hall - Convector south - Setpoint status", 9, 1),
|
||
("4/2/3", "3.01 Hall - Convector south - HVAC mode", 20, 102),
|
||
])
|
||
by = {e["operation_mode_address"]: e for e in cl}
|
||
assert by["4/1/3"]["target_temperature_state_address"] == "4/1/2", cl
|
||
assert by["4/2/3"]["target_temperature_state_address"] == "4/2/2", cl
|
||
assert by["4/1/3"]["temperature_address"] == by["4/2/3"]["temperature_address"] == "4/0/1", cl
|
||
print("OK: F1 — same-type devices told apart by a word, shared room sensor")
|
||
|
||
# F2. two devices we cannot tell apart ("AC_1"/"AC_2") -> never merged, never a silent pick
|
||
cl, rv = _climates([
|
||
("5/0/1", "Hall temperature", 9, 1),
|
||
("5/1/1", "Hall AC_1 setpoint", 9, 1), ("5/1/2", "Hall AC_1 setpoint status", 9, 1),
|
||
("5/1/3", "Hall AC_1 mode", 20, 105),
|
||
("5/2/1", "Hall AC_2 setpoint", 9, 1), ("5/2/2", "Hall AC_2 setpoint status", 9, 1),
|
||
("5/2/3", "Hall AC_2 mode", 20, 105),
|
||
])
|
||
assert not cl, cl
|
||
assert {r["address"] for r in rv if r["reason"] in ("climate_ambiguous", "climate_duplicate_anchor")} == {"5/1/3", "5/2/3"}, rv
|
||
print("OK: F2 — indistinguishable same-type devices go to review, nothing is guessed")
|
||
|
||
# F3. a value or a device tag is not a room code or a room number; a shared room sensor
|
||
# fits a numbered device ("Room 1 Temperature" for "Room 1 Floor heating 2")
|
||
cl, rv = _climates([
|
||
("6/0/1", "Room 1 Temperature", 9, 1),
|
||
("6/1/1", "Room 1 Floor heating 2 setpoint 21.5 °C", 9, 1),
|
||
("6/1/2", "Room 1 Floor heating 2 setpoint 21.5 °C status", 9, 1),
|
||
("6/1/3", "Room 1 Floor heating 2 D.1.2 HVAC mode", 20, 102),
|
||
])
|
||
assert len(cl) == 1 and cl[0]["temperature_address"] == "6/0/1" and cl[0]["target_temperature_state_address"] == "6/1/2", (cl, rv)
|
||
print("OK: F3 — '21.5' is no room code, 'D.1.2' no room number, shared sensor fits a numbered loop")
|
||
|
||
# F4. a second floor loop's word ("shower") keeps its members away from the main loop
|
||
cl, rv = _climates([
|
||
("7/0/1", "1.09 Bath - Air temperature", 9, 1),
|
||
("7/1/1", "1.09 Bath - Теплый пол - Уставка", 9, 1), ("7/1/2", "1.09 Bath - Теплый пол - Уставка - Статус", 9, 1),
|
||
("7/1/3", "1.09 Bath - Теплый пол - Режим", 20, 102),
|
||
("7/2/1", "1.09 Bath - Теплый пол душ - Уставка", 9, 1), ("7/2/2", "1.09 Bath - Теплый пол душ - Уставка - Статус", 9, 1),
|
||
("7/2/3", "1.09 Bath - Теплый пол душ - Режим", 20, 102),
|
||
])
|
||
by = {e["operation_mode_address"]: e for e in cl}
|
||
assert by["7/1/3"]["target_temperature_state_address"] == "7/1/2", cl
|
||
assert by["7/2/3"]["target_temperature_state_address"] == "7/2/2", cl
|
||
assert len(_controls(cl)) == len(set(_controls(cl))), cl
|
||
print("OK: F4 — main floor loop and shower loop each keep their own setpoint and mode")
|
||
|
||
# F5. only 20.102 / 20.105 anchor a climate
|
||
cl, rv = _climates([
|
||
("8/0/1", "Lab temperature", 9, 1), ("8/0/2", "Lab heating setpoint status", 9, 1),
|
||
("8/0/3", "Lab HVAC control mode", 20, 1),
|
||
])
|
||
assert not cl, cl
|
||
assert any(r["address"] == "8/0/3" for r in rv), rv # not an anchor, but never dropped silently
|
||
print("OK: F5 — a 20.001 GA does not start a climate entity and still reaches review")
|
||
|
||