maziggy e5a18bf58b Key a K profile on its nozzle's flow type
A printer files each calibration under a nozzle id of the form HH00-0.4
(high flow) or HS00-0.4 (standard) and can hold both for one diameter -- a
maintainer's H2D carries 102 high-flow entries against 6 standard --
because the same filament reads a different K through each. Nothing read
that, so a standard-flow profile could be selected for a high-flow nozzle
and vice versa.

The flow is now stored with the profile, shown against each option in the
picker, and checked before a stored profile is applied. Two spellings have
to agree for that: a calibration entry says HH00-0.4 while the fitted
nozzle reports HH01, so the comparison is two characters rather than four
-- the trailing digits are a hardware variant the calibration table
normalises to 00.

Unknown flow on either side matches anything, which is what it has to do.
Every profile stored before this has none. And an X1C declares none on any
profile at all -- probed live, all eight come back with an empty nozzle id,
against a four-digit cali_idx and a populated setting_id -- even though the
machine really does take either nozzle. supports_nozzle_flow_type is
therefore the wrong thing to gate on: it returns True for an X1C, and
treating that silence as Standard would have dropped every X1C profile the
moment a high-flow nozzle was fitted. What the printer's own table declares
per profile is the test.

NozzleInfo.nozzle_type carries two vocabularies by printer generation --
the nozzle material on legacy printers, the flow code on H2 -- and the
comment claiming only the former is corrected. Anything that is not HH or
HS reads as unknown, which is what makes the material spelling harmless.

Storing both flows for one hotend and diameter is deliberately not done:
spoolman_k_profile is UNIQUE on (spool, printer, extruder, diameter) with
no flow column, and allowing a second row in internal mode alone would
break inventory-mode parity. The picker marks a profile whose flow does not
match what is fitted instead of letting it look configured while doing
nothing.