maziggy 379b1c14bc fix(printer): Flow Calibration was silently skipped — wrong project_file fields (#1478)
The H2S never ran flow-dynamics calibration even with the print option
  enabled, because start_print built the project_file command wrong:

  - extrude_cali_flag was hardcoded to 0. A BambuStudio request-topic
    capture from a real H2D (plus X1C/P2S captures) shows it is always 1
    (run calibration) or 2 (skip, reuse stored PA), paired with flow_cali,
    never 0 — so the printer skipped calibration regardless of the toggle.
  - flow_cali and the other calibration/leveling fields were integer-
    encoded for the H2 family on a mistaken belief that H2 firmware
    requires 0/1. The same capture sends plain JSON booleans for every
    model; the belief conflated these fields with use_ams (which does
    need to stay boolean — the actual #1386 cause).

  Fix: extrude_cali_flag = 1 if flow_cali else 2; send timelapse,
  bed_leveling, flow_cali, vibration_cali and layer_inspect as booleans
  for all models; drop the is_h_family integer-conversion branch.
  use_ams is unchanged.

  Corrected the two tests that asserted the integer format and renamed
  them; all three model tests now also assert extrude_cali_flag.
2026-05-21 14:50:29 +02:00
..