Files
bambuddy/backend
maziggy d67f1a1c03 fix: inventory spool weight_used reset by AMS remain% sync
The on_ams_change() handler recalculated weight_used from the AMS
remain% sensor on every status update, overwriting precise values
from the usage tracker. For small prints on large spools (e.g. 1.6g
on 1000g), the integer-resolution sensor (10g steps) still reported
100% remain, resetting weight_used back to 0. The sync now only
increases weight_used, never decreases it.