maziggy 70312b0a11 fix(scheduler): skip per-nozzle filter under FTS so dispatch feeds the right spool (#2186)
On a dual-nozzle H2C with a Filament Track Switch, a queued print targeting
one nozzle fed a same-type wrong-colour spool: the backend mapping
(_match_filaments_to_slots) hard-filtered candidate trays to the requested
extruder, excluding the correct spool loaded in the other nozzle's AMS — which
the FTS can route across. Confirmed from the reporter's captures: same model
mapped to AMS-A slot 2 (black) on the left nozzle but AMS-B slot 3 (red) on the
right. The #1162 FTS-skip existed only in the frontend mapping, never the
queue-dispatch path.

Read fila_switch.installed in _compute_ams_mapping_for_printer and skip the
per-nozzle filter when an FTS is present. Single-nozzle printers are unaffected
(no nozzle_id in the 3MF, no FTS). Regression tests in TestFtsNozzleBypass.
2026-07-07 12:17:46 +02:00
..