maziggy a4cfbd4212 fix(archives): come back for a 3MF whose transfer ran out of time (issue #3063)
The reporter's P1S had the sliced file on its card and was serving it. The 19MB
transfer just did not finish inside the budget while the printer was also running
its camera, its status messages and the upload of the job itself. Bambuddy wrote
an empty fallback archive and never looked again -- then downloaded that same file
successfully three times over the next two minutes and discarded every copy,
because the only code that would have attached one had already run.

The recovery machinery was there. It was armed for exactly one give-up, the FTPS
cool-off, on the grounds that the three storage verdicts are settled: a job on
internal eMMC never appears at any FTPS path, and sweeping for it again is what
where the file is demonstrably still on the card.

The sweep already had the signal and never used it. A file that is genuinely not
there is answered with 550, which surfaces as FileNotOnPrinterError and is caught
by name; a timeout returns falsy instead. So "the printer says no such file" and
"we never got a straight answer" are distinguishable without guessing, and only
the second schedules anything.

Not scheduled either for a 3MF that downloaded fine and turned out to be another
plate's. Recovery checks that a candidate is a readable 3MF but not which plate it
holds, and the names a retry would use are the same stale ones that fetched the
contradicted file -- so it would put back exactly what #2957 discards.

The ladder follows the cause: a cool-off has to expire, so its first attempt sits
past the 300s; nothing has to expire here, and this reporter's file completed 48
seconds after the budget was spent.

The archives banner gets its own wording for this, because the old text sends an
owner whose card is working to switch on a setting that is already on. It names
the Connection Timeout setting instead.
2026-09-18 13:38:02 +02:00
..