With a switch fitted, an AMS is not wired to a nozzle any more. It is plumbed into one of the switch's two inlets and reaches both nozzles through it, so every unit reports its extruder as "not fixed" (0xE) and ams_extruder_map comes back empty on these machines. The printer card had nothing to fall back on but the AMS unit number, so AMS-A was badged R and AMS-B was badged L purely because their unit ids are 0 and 1, a third unit got no badge at all, and every one of those labels was wrong. The SpoolBuddy assign modal had the same fallback in a worse form, mapping anything that was not extruder 1 to R. The binding turned out to need no new telemetry. BambuStudio reads it out of bits 24-27 of the same AMS info string we already parse for the AMS type and the extruder id -- 0 is In-B, 1 is In-A -- and it is only meaningful when a switch is installed, because without one 0xE really does mean an uninitialised unit and those bits carry nothing. That gates the read, which in turn forced the switch block to be parsed before the AMS block: _handle_ams_data runs early in _process_message and _update_state only much later, so the binding was lost on every frame that carried both. _parse_fila_switch is split out and called first, and left in _update_state as well so that stays a complete absorb step. The badge keeps L and R rather than A and B, because the lettering is familiar and matches the physical layout. It is a different colour from the plain nozzle badge, and its tooltip names the inlet in full, since the letter is the inlet's position and not a claim about which nozzle that AMS feeds -- the switch can route either inlet to either outlet. An AMS still reporting a real extruder id keeps its ordinary badge, which BambuStudio also treats as authoritative over any switch binding, and a switch that has been fitted but not yet set up on the printer shows nothing rather than a guess. The print dialog's slot dropdown gets the same label. It replaces a left/right hint that never once rendered: ftsExtruderForSlot compared snow-encoded in[] values against global tray ids and could not match. Decoding it correctly would not have saved it -- the firmware reports which slot sits in each inlet and which nozzle each outlet feeds, but never which inlet is currently paired with which outlet, so no per-slot nozzle can be derived. That function is gone rather than fixed. The dialog also points out when every filament a print needs sits behind one inlet. Bambu's own guidance is that this is legal but slow: a change between two filaments on the same inlet retracts the outgoing spool all the way back to its AMS before the next can be fed up the shared tube, where a change across the two inlets only retracts as far as the switch. All on one inlet means every change in the job takes the slow path, and moving a single spool fixes it. So it advises, it does not block. Both views update live. Two things were stopping that. fila_switch and ams_switch_inlet were absent from printer_state_to_dict, and the frontend shallow-merges each WebSocket push over its cached status, so a field the push omits keeps whatever the last full fetch left behind. And the broadcast dedup key had no term for either, so "Join IN-B" on the printer screen moved nothing: the binding is not in the tray component of that key, and it is not in the AMS change-hash either, which covers tray fields only and must stay that way because it drives Spoolman sync. Assigning an AMS to an inlet remains printer-side. BambuStudio can read the binding and has no command to write it -- its switch class is parse and getters only, and the recommended-arrangement popup draws and publishes nothing -- so there is no wire format for us to copy. Adding the two fields to PrinterState broke four test modules whose SimpleNamespace stubs predate them. The stubs are fixed rather than the production reads made defensive: the real dataclass always carries both, and a getattr in the dedup key would silently stop tracking the field if it were ever renamed.
448 lines
20 KiB
Python
448 lines
20 KiB
Python
from datetime import datetime
|
|
|
|
from pydantic import BaseModel, Field, field_validator
|
|
|
|
from backend.app.utils.printer_models import supports_nozzle_flow_type
|
|
|
|
|
|
class PrinterBase(BaseModel):
|
|
name: str = Field(..., min_length=1, max_length=100)
|
|
serial_number: str = Field(..., min_length=1, max_length=50)
|
|
|
|
@field_validator("serial_number")
|
|
@classmethod
|
|
def _normalize_serial_number(cls, v: str) -> str:
|
|
"""Uppercase and trim the serial number.
|
|
|
|
Bambu serial numbers are uppercase alphanumeric, and the MQTT report
|
|
topic ``device/<serial>/report`` is case-sensitive. A serial entered
|
|
in the wrong case (or with stray whitespace) connects and subscribes
|
|
without error but never receives a message — the printer publishes to
|
|
the correctly-cased topic, so every status field stays unknown (#1465).
|
|
Normalising on input makes the subscribed topic always match.
|
|
"""
|
|
normalized = v.strip().upper()
|
|
if not normalized:
|
|
raise ValueError("serial_number must not be blank")
|
|
return normalized
|
|
|
|
ip_address: str = Field(
|
|
...,
|
|
max_length=253,
|
|
pattern=r"^(\d{1,3}(\.\d{1,3}){3}|[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?(\.[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?)*)$",
|
|
)
|
|
model: str | None = None
|
|
location: str | None = None # Group/location name
|
|
auto_archive: bool = True
|
|
external_camera_url: str | None = None
|
|
external_camera_type: str | None = None # "mjpeg", "rtsp", "snapshot", "usb"
|
|
external_camera_enabled: bool = False
|
|
external_camera_snapshot_url: str | None = None # Optional single-frame override; #1177
|
|
camera_rotation: int = 0 # 0, 90, 180, 270 degrees
|
|
|
|
|
|
class PrinterCreate(PrinterBase):
|
|
# access_code lives on the input shapes only — never on the default
|
|
# PrinterResponse. Direct exposure on PRINTERS_READ would let a Viewer
|
|
# connect to the printer's MQTT and bypass Bambuddy's RBAC.
|
|
access_code: str = Field(..., min_length=1, max_length=20)
|
|
|
|
|
|
class PlateDetectionROI(BaseModel):
|
|
"""Region of interest for plate detection (percentages 0.0-1.0)."""
|
|
|
|
x: float = Field(..., ge=0.0, le=1.0) # X start %
|
|
y: float = Field(..., ge=0.0, le=1.0) # Y start %
|
|
w: float = Field(..., ge=0.0, le=1.0) # Width %
|
|
h: float = Field(..., ge=0.0, le=1.0) # Height %
|
|
|
|
|
|
class PrinterUpdate(BaseModel):
|
|
name: str | None = None
|
|
ip_address: str | None = Field(
|
|
default=None,
|
|
max_length=253,
|
|
pattern=r"^(\d{1,3}(\.\d{1,3}){3}|[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?(\.[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?)*)$",
|
|
)
|
|
access_code: str | None = None
|
|
model: str | None = None
|
|
location: str | None = None
|
|
is_active: bool | None = None
|
|
auto_archive: bool | None = None
|
|
print_hours_offset: float | None = None
|
|
external_camera_url: str | None = None
|
|
external_camera_type: str | None = None
|
|
external_camera_enabled: bool | None = None
|
|
external_camera_snapshot_url: str | None = None # #1177
|
|
camera_rotation: int | None = None # 0, 90, 180, 270 degrees
|
|
plate_detection_enabled: bool | None = None
|
|
plate_detection_roi: PlateDetectionROI | None = None
|
|
|
|
|
|
class PrinterResponse(PrinterBase):
|
|
id: int
|
|
is_active: bool
|
|
nozzle_count: int = 1 # 1 or 2, auto-detected from MQTT
|
|
# Whether the model is sold with both Standard and High Flow nozzles, so a
|
|
# K-profile's flow type is a real choice rather than a meaningless field.
|
|
# Derived from the model, not from nozzle_count — see
|
|
# printer_models.supports_nozzle_flow_type.
|
|
supports_nozzle_flow_type: bool = True
|
|
print_hours_offset: float = 0.0
|
|
external_camera_url: str | None = None
|
|
external_camera_type: str | None = None
|
|
external_camera_enabled: bool = False
|
|
external_camera_snapshot_url: str | None = None # #1177
|
|
camera_rotation: int = 0 # 0, 90, 180, 270 degrees
|
|
plate_detection_enabled: bool = False
|
|
plate_detection_roi: PlateDetectionROI | None = None
|
|
created_at: datetime
|
|
updated_at: datetime
|
|
|
|
class Config:
|
|
from_attributes = True
|
|
|
|
@classmethod
|
|
def from_orm_with_roi(cls, printer) -> "PrinterResponse":
|
|
"""Create response from ORM model, converting ROI fields to nested object."""
|
|
data = {
|
|
"id": printer.id,
|
|
"name": printer.name,
|
|
"serial_number": printer.serial_number,
|
|
"ip_address": printer.ip_address,
|
|
"model": printer.model,
|
|
"location": printer.location,
|
|
"auto_archive": printer.auto_archive,
|
|
"external_camera_url": printer.external_camera_url,
|
|
"external_camera_type": printer.external_camera_type,
|
|
"external_camera_enabled": printer.external_camera_enabled,
|
|
"external_camera_snapshot_url": printer.external_camera_snapshot_url,
|
|
"camera_rotation": printer.camera_rotation,
|
|
"is_active": printer.is_active,
|
|
"nozzle_count": printer.nozzle_count,
|
|
"supports_nozzle_flow_type": supports_nozzle_flow_type(printer.model),
|
|
"print_hours_offset": printer.print_hours_offset,
|
|
"plate_detection_enabled": printer.plate_detection_enabled,
|
|
"created_at": printer.created_at,
|
|
"updated_at": printer.updated_at,
|
|
}
|
|
# Build ROI object if any ROI field is set
|
|
if any(
|
|
[
|
|
printer.plate_detection_roi_x is not None,
|
|
printer.plate_detection_roi_y is not None,
|
|
printer.plate_detection_roi_w is not None,
|
|
printer.plate_detection_roi_h is not None,
|
|
]
|
|
):
|
|
data["plate_detection_roi"] = PlateDetectionROI(
|
|
x=printer.plate_detection_roi_x or 0.15,
|
|
y=printer.plate_detection_roi_y or 0.35,
|
|
w=printer.plate_detection_roi_w or 0.70,
|
|
h=printer.plate_detection_roi_h or 0.55,
|
|
)
|
|
return cls(**data)
|
|
|
|
|
|
class PrinterResponseWithSecret(PrinterResponse):
|
|
"""PrinterResponse + access_code. Returned ONLY to callers with
|
|
PRINTERS_UPDATE (Admin / Operator JWTs, or single-trust auth-disabled mode).
|
|
|
|
Viewers and API keys never receive this shape — they get the bare
|
|
PrinterResponse without access_code, since holding the access_code lets
|
|
the caller talk to the printer's MQTT directly and bypass Bambuddy's RBAC.
|
|
"""
|
|
|
|
access_code: str
|
|
|
|
|
|
class HMSErrorResponse(BaseModel):
|
|
code: str
|
|
attr: int = 0 # Attribute value for constructing wiki URL
|
|
module: int
|
|
severity: int # 1=fatal, 2=serious, 3=common, 4=info
|
|
actions: list[str] = [] # List of user-facing action keys (e.g. "CHECK_FILAMENT")
|
|
job_id: str | None = None # Optional job ID for actions that require it (e.g. "CHECK_ASSISTANT")
|
|
# Canonical hex identifier the firmware uses to match HMS-related commands.
|
|
# 16 chars for `hms[]`-array faults (full 64-bit attr+code), 8 chars for
|
|
# `print_error` faults. The frontend echoes this back as
|
|
# HmsActionBody.print_error so we send the firmware-recognised key, not the
|
|
# truncated short_code that historically caused silent command rejection
|
|
# (#1830, H2D wrong-plate verification).
|
|
full_code: str = ""
|
|
|
|
|
|
class AMSTray(BaseModel):
|
|
id: int
|
|
tray_color: str | None = None
|
|
tray_type: str | None = None
|
|
tray_sub_brands: str | None = None # Full name like "PLA Basic", "PETG HF"
|
|
tray_id_name: str | None = None # Bambu filament ID like "A00-Y2" (can decode to color)
|
|
tray_info_idx: str | None = None # Filament preset ID like "GFA00"
|
|
remain: int = 0
|
|
k: float | None = None # Pressure advance value (from tray or K-profile lookup)
|
|
cali_idx: int | None = None # Calibration index for K-profile lookup
|
|
tag_uid: str | None = None # RFID tag UID (any tag)
|
|
tray_uuid: str | None = None # Bambu Lab spool UUID (32-char hex)
|
|
nozzle_temp_min: int | None = None # Min nozzle temperature
|
|
nozzle_temp_max: int | None = None # Max nozzle temperature
|
|
drying_temp: int | None = None # RFID-recommended drying temp
|
|
drying_time: int | None = None # RFID-recommended drying time (hours)
|
|
state: int | None = None # AMS tray state: 9=empty, 10=spool present not loaded, 11=loaded
|
|
# Firmware's authoritative "spool physically present" bit (from tray_exist_bits).
|
|
# True for a non-RFID spool the firmware can't identify — the UI shows "?" rather
|
|
# than "Empty" (#2527). None when the bitmask was unavailable (→ state-based fallback).
|
|
exists: bool | None = None
|
|
|
|
|
|
class AMSUnit(BaseModel):
|
|
id: int
|
|
humidity: int | None = None
|
|
temp: float | None = None
|
|
is_ams_ht: bool = False # True for AMS-HT (single spool), False for regular AMS (4 spools)
|
|
tray: list[AMSTray] = []
|
|
serial_number: str = "" # AMS unit serial number (sn from MQTT)
|
|
sw_ver: str = "" # AMS firmware version (from get_version info.module)
|
|
dry_time: int = 0 # Minutes remaining (0 = not drying, >0 = drying active)
|
|
dry_status: int = 0 # 0=Off, 1=Checking, 2=Drying, 3=Cooling, 4=Stopping, 5=Error
|
|
dry_sub_status: int = 0 # 0=Off, 1=Heating, 2=Dehumidify
|
|
dry_sf_reason: list[int] = [] # Cannot-dry reasons from firmware (see CannotDryReason)
|
|
dry_target_temp: int | None = None # Active-cycle target °C (Bambu doesn't echo this)
|
|
dry_filament: str | None = None # Active-cycle filament name we sent
|
|
module_type: str = "" # "ams", "n3f", "n3s"
|
|
|
|
|
|
class NozzleInfoResponse(BaseModel):
|
|
nozzle_type: str = "" # "stainless_steel" or "hardened_steel"
|
|
nozzle_diameter: str = "" # e.g., "0.4"
|
|
|
|
|
|
class NozzleRackSlot(BaseModel):
|
|
"""H2C nozzle rack slot (6-position tool-changer dock)."""
|
|
|
|
id: int = 0
|
|
nozzle_type: str = ""
|
|
nozzle_diameter: str = ""
|
|
wear: int | None = None
|
|
stat: int | None = None # Nozzle status (e.g. mounted/docked)
|
|
max_temp: int = 0 # Max temperature rating °C (0 = not set)
|
|
serial_number: str = "" # Nozzle serial number
|
|
filament_color: str = "" # RGBA hex ("00000000" = no filament)
|
|
filament_id: str = "" # Bambu filament ID
|
|
filament_type: str = "" # Material type (e.g. "PLA", "PETG")
|
|
|
|
|
|
class AmsLabelBody(BaseModel):
|
|
label: str = Field(..., min_length=1, max_length=100)
|
|
ams_serial: str = Field(default="", max_length=50)
|
|
|
|
|
|
class HmsActionBody(BaseModel):
|
|
# Canonical hex identifier (HMSErrorResponse.full_code): 8 chars for
|
|
# `print_error`-sourced faults, 16 chars for `hms[]`-array faults whose
|
|
# full 64-bit code is the firmware's matching key. Length-bounded to
|
|
# those two valid shapes to keep stray input from reaching the dispatcher.
|
|
print_error: str = Field(..., min_length=8, max_length=16, pattern=r"^[0-9A-Fa-f]{8}([0-9A-Fa-f]{8})?$")
|
|
# One of the HMSAction enum values. Length-capped to keep stray input from
|
|
# reaching the dispatcher's `match` statement.
|
|
action: str = Field(..., min_length=1, max_length=64)
|
|
# The `subtask_id` snapshot from the HMSError that surfaced this dialog.
|
|
# Bambu echoes it back in HMS-aware commands. Optional for idle errors.
|
|
job_id: str | None = Field(default=None, max_length=64)
|
|
|
|
|
|
class FilaSwitchResponse(BaseModel):
|
|
"""Filament Track Switch (FTS) state — accessory that mediates AMS-to-extruder routing.
|
|
|
|
When installed, the AMS info field reports bits 8-11 = 0xE (uninitialized)
|
|
because slots are dynamically routed via the FTS rather than tied to a
|
|
specific extruder. Frontend uses `installed` to suppress the per-extruder
|
|
slot filter in the print modal. See #1162.
|
|
"""
|
|
|
|
installed: bool = False
|
|
# in[track] = currently loaded slot for that track (-1 = empty)
|
|
in_slots: list[int] = []
|
|
# out[track] = extruder this track terminates at (0 = right, 1 = left)
|
|
out_extruders: list[int] = []
|
|
stat: int = 0
|
|
info: int = 0
|
|
|
|
|
|
class PrintOptionsResponse(BaseModel):
|
|
"""AI detection and print options from xcam data."""
|
|
|
|
# Core AI detectors
|
|
spaghetti_detector: bool = False
|
|
print_halt: bool = False
|
|
halt_print_sensitivity: str = "medium" # Spaghetti sensitivity
|
|
first_layer_inspector: bool = False
|
|
printing_monitor: bool = False
|
|
buildplate_marker_detector: bool = False
|
|
allow_skip_parts: bool = False
|
|
# Additional AI detectors (decoded from cfg bitmask)
|
|
nozzle_clumping_detector: bool = True
|
|
nozzle_clumping_sensitivity: str = "medium"
|
|
pileup_detector: bool = True
|
|
pileup_sensitivity: str = "medium"
|
|
airprint_detector: bool = True
|
|
airprint_sensitivity: str = "medium"
|
|
auto_recovery_step_loss: bool = True
|
|
filament_tangle_detect: bool = False
|
|
|
|
|
|
class PrinterStatus(BaseModel):
|
|
id: int
|
|
name: str
|
|
connected: bool
|
|
state: str | None = None
|
|
current_print: str | None = None
|
|
subtask_name: str | None = None
|
|
gcode_file: str | None = None
|
|
progress: float | None = None
|
|
remaining_time: int | None = None
|
|
layer_num: int | None = None
|
|
total_layers: int | None = None
|
|
temperatures: dict | None = None
|
|
cover_url: str | None = None
|
|
hms_errors: list[HMSErrorResponse] = []
|
|
ams: list[AMSUnit] = []
|
|
ams_exists: bool = False
|
|
vt_tray: list[AMSTray] = [] # Virtual tray / external spool(s)
|
|
sdcard: bool = False # SD card inserted
|
|
store_to_sdcard: bool = False # Store sent files on SD card
|
|
timelapse: bool = False # Timelapse recording active
|
|
ipcam: bool = False # Live view enabled
|
|
wifi_signal: int | None = None # WiFi signal strength in dBm
|
|
wired_network: bool = False # Ethernet connection detected
|
|
door_open: bool = False # Enclosure door open (X1/P1S/P2S/H2*)
|
|
nozzles: list[NozzleInfoResponse] = [] # Nozzle hardware info (index 0=left/primary, 1=right)
|
|
nozzle_rack: list[NozzleRackSlot] = [] # H2C 6-nozzle tool-changer rack
|
|
print_options: PrintOptionsResponse | None = None # AI detection and print options
|
|
# Calibration stage tracking
|
|
stg_cur: int = -1 # Current stage number (-1 = not calibrating)
|
|
stg_cur_name: str | None = None # Human-readable current stage name
|
|
stg: list[int] = [] # List of stage numbers in calibration sequence
|
|
# Air conditioning mode (0=cooling, 1=heating)
|
|
airduct_mode: int = 0
|
|
# Print speed level (1=silent, 2=standard, 3=sport, 4=ludicrous)
|
|
speed_level: int = 2
|
|
# Chamber light on/off
|
|
chamber_light: bool = False
|
|
# Active extruder for dual nozzle (0=right, 1=left)
|
|
active_extruder: int = 0
|
|
# AMS mapping for dual nozzle: which AMS is connected to which nozzle
|
|
ams_mapping: list[int] = []
|
|
# Per-AMS extruder map: {ams_id: extruder_id} where 0=right, 1=left
|
|
ams_extruder_map: dict[str, int] = {}
|
|
# Filament Track Switch (FTS) accessory — when installed, AMS reports
|
|
# bits 8-11 = 0xE (uninitialized) and routing is dynamic via the FTS. See #1162.
|
|
fila_switch: FilaSwitchResponse | None = None
|
|
# Per-AMS FTS inlet binding: {ams_id: "A" | "B"}, from AMS info bits 24-27.
|
|
# Which of the switch's two inlets each AMS is plumbed into, as set on the
|
|
# printer's "Manual AMS Setup" screen. Empty unless an FTS is installed —
|
|
# an FTS-bound AMS reaches BOTH nozzles, so it has no entry in
|
|
# ams_extruder_map and must not be labelled left or right.
|
|
ams_switch_inlet: dict[str, str] = {}
|
|
# Currently loaded tray (global ID): 254 = external spool, 255 = no filament
|
|
tray_now: int = 255
|
|
# Runout / filament-replacement guidance (#2587). Populated only while the
|
|
# print is PAUSED. Both are globalised tray IDs (ams_id*4+slot, or 128-135 for
|
|
# AMS-HT, or 254 for external) so the frontend can highlight them with the same
|
|
# logic it uses for tray_now:
|
|
# expected_tray = the slot the firmware now expects filament in (from tray_tar).
|
|
# None when idle, not paused, or the slot can't be resolved
|
|
# (multi-AMS ambiguity) — the UI then says "check the printer".
|
|
# previous_tray = the slot loaded before the pause, i.e. the one that ran out
|
|
# (from tray_pre). None when unknown.
|
|
expected_tray: int | None = None
|
|
previous_tray: int | None = None
|
|
# AMS status for filament change tracking
|
|
# Main status: 0=idle, 1=filament_change, 2=rfid_identifying, 3=assist, 4=calibration
|
|
ams_status_main: int = 0
|
|
# Sub status: specific step within filament change (when main=1)
|
|
# Known values: 4=retraction, 6=load verification, 7=purge
|
|
ams_status_sub: int = 0
|
|
# mc_print_sub_stage - filament change step indicator used by OrcaSlicer/BambuStudio
|
|
mc_print_sub_stage: int = 0
|
|
# Timestamp of last AMS data update (for RFID refresh detection)
|
|
last_ams_update: float = 0.0
|
|
# Number of printable objects in current print (for skip objects feature)
|
|
printable_objects_count: int = 0
|
|
# Fan speeds (0-100 percentage, None if not available for this model)
|
|
cooling_fan_speed: int | None = None # Part cooling fan
|
|
big_fan1_speed: int | None = None # Auxiliary fan
|
|
big_fan2_speed: int | None = None # Chamber/exhaust fan
|
|
heatbreak_fan_speed: int | None = None # Hotend heatbreak fan
|
|
# Left auxiliary part cooling fan (optional P2S/X2D accessory, airduct part id 10).
|
|
# None = not installed / not reported by this model.
|
|
left_aux_fan_speed: int | None = None
|
|
# Chamber exhaust fan present (P2S/X2D External Exhaust Fan kit; airduct part id 3).
|
|
exhaust_fan_present: bool = False
|
|
# Firmware version (from info.module[name="ota"].sw_ver)
|
|
firmware_version: str | None = None
|
|
# Developer LAN mode: True = enabled, False = disabled (MQTT encryption), None = unknown
|
|
developer_mode: bool | None = None
|
|
# AMS Filament Backup ("auto-switch" to a second spool when one runs out).
|
|
# True = ON, False = OFF, None = unknown / unsupported (A1 family — protocol field
|
|
# not yet identified). UI treats None as "status unavailable", not as a hard disable.
|
|
ams_filament_backup: bool | None = None
|
|
# Queue: printer is awaiting the user to acknowledge the build plate is cleared
|
|
# after a finished/failed print. Persisted across restarts (#961).
|
|
awaiting_plate_clear: bool = False
|
|
# AMS drying support
|
|
supports_drying: bool = False
|
|
# AMS "Print While Drying" — drying mid-print. Verified per Bambu wiki release notes;
|
|
# see _DRY_WHILE_PRINTING_MIN_FIRMWARE in printer_manager.py for the matrix.
|
|
supports_drying_while_printing: bool = False
|
|
# The AMS can dry, but only from the printer's own screen (P1 series, #2533).
|
|
# supports_drying is False on these; the UI keeps the control visible but disabled
|
|
# and says why, rather than dropping it without explanation.
|
|
drying_screen_only: bool = False
|
|
# Active chamber heater (responds to M141). True only for H2C/H2D/H2DPro/H2S/X2D.
|
|
supports_chamber_heater: bool = False
|
|
# Linked archive for the active print (resolved via subtask_id). Frontend uses
|
|
# this to fetch plate metadata and show the plate name when the source 3MF is
|
|
# multi-plate (#881 follow-up).
|
|
current_archive_id: int | None = None
|
|
# 1-indexed plate number parsed from gcode_file (e.g. /Metadata/plate_2.gcode).
|
|
# Set for every active print regardless of plate count; the frontend decides
|
|
# whether to render it based on current_archive_id's is_multi_plate flag.
|
|
current_plate_id: int | None = None
|
|
|
|
|
|
class DiagnosticCheck(BaseModel):
|
|
"""One connection-diagnostic check result.
|
|
|
|
``id`` is a stable key (port_mqtt, port_ftps, port_rtsps, network_mode,
|
|
subnet, mqtt_auth, developer_mode); the frontend renders the localized
|
|
title and fix text from id + status. ``params`` carries interpolation
|
|
values (e.g. network mode, IP addresses) for that text.
|
|
"""
|
|
|
|
id: str
|
|
status: str # "pass" | "fail" | "warn" | "skip"
|
|
params: dict = Field(default_factory=dict)
|
|
|
|
|
|
class PrinterDiagnosticResult(BaseModel):
|
|
"""Result of a printer connection diagnostic run."""
|
|
|
|
printer_id: int | None = None
|
|
ip_address: str
|
|
overall: str # "ok" | "warnings" | "problems"
|
|
checks: list[DiagnosticCheck]
|
|
|
|
|
|
class DiagnosticRequest(BaseModel):
|
|
"""Pre-save (Add Printer) connection diagnostic request.
|
|
|
|
serial_number + access_code are optional: when both are present the
|
|
diagnostic also probes MQTT credentials, otherwise only the
|
|
network-level checks run.
|
|
"""
|
|
|
|
ip_address: str
|
|
serial_number: str | None = None
|
|
access_code: str | None = None
|