H2S is single-nozzle (nozzle_count=1 across 9+ stored support bundles
and the reporter's diagnostic) but had been added to the H-family model
gate in start_print_job. That single flag controlled both the firmware
bool->int format (legitimately needed for the whole H-family, including
H2S) and the dual-nozzle external-spool routing (correct only for actual
dual-extruder printers).
With no AMS attached and an external-spool slot (tray_id=254), the
dual-nozzle branch wrote ams_id=254 into ams_mapping2 instead of the
canonical 255 — exactly the failure the comment six lines above warns
against. Firmware rejected the dispatch with 07FF_8012 "Failed to get
AMS mapping table". The use_ams=False fallback was also being skipped
because the H-family bypass was meant for dual-nozzle routing.
A second site at bambu_mqtt.py:3987 and its sibling at kprofiles.py:119
detected dual-nozzle by serial prefix ("094", "20P9", "31B8B"). H2S
shares prefix "094" with H2D, so prefix detection misclassified it too.
Split the conflated flag into two:
- is_h_family — firmware format (int 0/1 for calibration fields).
Includes H2S. H2S firmware structurally accepted the current command
shape (failure was at AMS routing, not parsing), so the int format
stays for H2S.
- is_dual_nozzle — external-spool routing and use_ams gating. Excludes
H2S. Source-of-truth is the runtime _is_dual_nozzle flag set from
device.extruder.info, with a model-name fallback for the brief window
after connect before push data arrives.
The K-profile delete site and the kprofiles route now use the same
runtime+model check instead of serial prefix.