maziggy 072b8c8ce1 fix(vp): preserve AMS/vt_tray/net across incremental push_status updates (#1371)
The bridge cache replaced _latest_print_state wholesale on every
  push_status arrival. Bambu firmware sends full pushall responses
  (with AMS/vt_tray/net.info/lights_report) on reconnect / pushall
  requests, but ~1 Hz incremental updates with only the fields that
  changed. The first incremental push after a pushall therefore wiped
  AMS info from the bridge cache, and slicers reading the cache (via
  the VP's 1 Hz status push) saw a stripped-down state with no AMS
  visible until the next pushall — typically only on a manual printer
  power-cycle.

  Preserve a small set of slicer-visible sticky keys from the previous
  cache when the incoming push doesn't carry them: ams, vt_tray,
  ams_extruder_map, mapping, net, ipcam, lights_report. Mirrors the
  same pattern Bambuddy uses for its own internal state.raw_data.