mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-09-30 03:01:21 +02:00
The alert compares against ams_temp_fair, the same threshold that colours the printer card, which defaults to 35C. Drying deliberately runs at 45C for PLA, 65C for PETG and up to 85C on an AMS-HT, and the alert repeats once an hour for as long as the condition holds, so a twelve-hour dry sent twelve notifications about a temperature the user chose. It then kept sending them while the unit cooled back down, which is the half the reporter confirmed on an AMS 2 Pro and an H2C. Dispatch now consults the drying state the firmware already reports. dry_time alone is not enough: it reads 0 through the cooling phase that closes a cycle, so dry_status -- info bits 4-7, already parsed for the drying-complete edge -- carries the rest. That constant moves out of bambu_mqtt into a leaf util rather than being duplicated; drying_preflight would have been the natural home, but it imports printer_manager, which imports bambu_mqtt, and bambu_mqtt is one of the callers. The cool-down afterwards is held by a latch released as soon as the unit reads back at or below the threshold, rather than after a fixed delay, so a 65C cycle in a cold basement and a 45C one in a warm room each get the time they actually need. A two-hour cap bounds the one case the latch cannot resolve on its own -- a unit that never returns below the threshold -- and since such a unit would have been alarming with no drying involved, releasing there restores the ordinary behaviour instead of inventing a new alert. Two exclusions are deliberate. Humidity is untouched, because during drying that reading falling is the whole point. And dry_status 6, HeatOutOfControl, is kept out of the active set: an AMS that has lost thermal control is exactly when the alert should still arrive, so it must never read as expected heat. A cycle plus its cool-down outlasts a restart, so the latch is a settings row rather than a dict beside _ams_alarm_cooldown -- the internal timestamp-row pattern support.py already uses. It is read once per pass and written back only when a unit changed it. Stamps ahead of now are clamped on read, since a box whose clock jumps backwards writes them and suppression is measured as now minus the stamp; without the clamp the cap would measure from a moment that has not happened yet and hold the alert quiet for the skew on top of it. No new setting. The reporter was offered the opt-out checkbox they asked for and said they would not want it if the alert simply never fired during drying.