Files
bambuddy/backend/tests/unit/services
maziggy 76582298b5 fix(drying): stop false "drying complete" from killing the printer via smart-plug auto-off (#1462)
Reporter on X2D set a 1h AMS dry; the printer powered off seconds in.
  Support log: every "Sent drying command duration=1" was followed 3-9s
  later by "AMS 0 drying complete (dry_time 60 -> 0)" -- the completion
  callback fired right after drying started, arming smart-plug auto-off.

  Root cause: the tray-bearing branch of the AMS partial-update merge
  rebuilt the unit as {**ams_unit, "tray": merged_trays}, never spreading
  existing_unit. Tray-bearing partials carry no drying fields, so dry_time
  (and info) was dropped; the falling-edge detector read the absent field
  as 0 and saw a false 60->0 edge.

  - Merge: tray branch now spreads existing_unit first, preserving
    dry_time / info / humidity / temp across tray-only partials. Matches
    the no-tray branch. Also fixes dry_status/dry_sub_status UI flapping.
  - Detector: only evaluate the falling edge when dry_time is explicitly
    present and parseable; skip otherwise without updating state.