The Statistics page reported "Gesamt" (All Time) kWh correctly but showed
zero for Today/Week/Month in total-consumption mode. Two bugs drove it:
1. The starting plug counter was kept in an in-memory dict
`_print_energy_start` that was lost on any backend restart mid-print, so
the per-print `energy_kwh` delta silently never got computed. The stats
endpoint's fallback path `SUM(PrintArchive.energy_kwh)` therefore summed
to zero for users running in total mode.
2. Total-consumption mode has no per-print delta by design — it includes
idle/preheat/standby — so the fallback to archive rows was the wrong
strategy even when the data existed.
Fix, in two parts:
- Persist `energy_start_kwh` on the archive row and read it back from a
fresh session at print end. Deletes `_print_energy_start` and its 5
call sites, replacing them with a single `_record_energy_start()` helper.
Per-print tracking is now restart-resilient regardless of tracking mode.
- Add hourly `smart_plug_energy_snapshots` table + `_snapshot_loop()` in
SmartPlugManager. Rewrote the `/archives/stats` energy branch as
`_sum_snapshot_deltas()` which computes per-plug
`max(0, last-in-range - baseline)` where baseline is the latest snapshot
at or before the range start, falling back to the earliest-ever snapshot
and signalling `energy_data_warming_up` when no pre-range baseline
exists (fresh upgrade). MQTT plugs are skipped from snapshots since they
only report "today" and have no lifetime counter.
Frontend: QuickStatsWidget renders an AlertTriangle next to Energy Used /
Energy Cost with a tooltip when `energy_data_warming_up` is true, so the
"low values right after upgrading" situation is explained in-product.
Fully localised across 7 UI languages.
Tests: new backend unit tests cover the snapshot delta arithmetic
(baseline/endpoint, counter reset clamp, multi-plug, warming-up fallback,
endpoint windowing), per-print restart resilience via expunge_all, and the
snapshot task lifecycle (start idempotent, stop cancels). Frontend tests
assert the warning icon appears only when the flag is set and only on the
energy tiles.
Docs: updated `CHANGELOG.md`, `README.md`, wiki `features/energy.md`,
wiki `features/statistics.md`, and website `features.html` with the new
behaviour and warming-up explanation.