New printers report stage numbers before Bambuddy learns their names,
and the H2C still has several. Those reached the printer card verbatim,
as "Unknown stage (72)" -- a number that means nothing to the person
reading it, on the one line that otherwise says what the printer is
doing.
Every stage that has turned out to be unnamed so far has been part of
the run-up to printing, so an unnamed one now reads as "Preparing".
That is the same literal stage 74 already carries rather than a second
spelling of the same idea, so a card cannot show two different words
for the same situation depending on which number the firmware picked.
Display only, and deliberately not pushed down into get_stage_name.
That function also feeds the stage-transition log line and the
once-per-session warning added to capture unnamed stages so they can be
named in a later release; there the number is the entire diagnostic
value, and replacing it with "Preparing" would hide the only thing that
reports these. Both paths are pinned by tests asserting they disagree
for an unnamed stage and agree for a named one, so a later tidy-up
cannot quietly collapse them.
The idle sentinels are untouched: 255 on A1/P1 and -1 on X1 mean "no
stage", not an unnamed one, and still resolve to nothing rather than
being swept up by the fallback.
Nothing keys logic off stg_cur_name -- it is display-only in the printer
card, the print dialog's printer selector and the stream overlay -- so
all three improve and none change behaviour. No i18n either way: the
whole stage table has always been English.