maziggy 18dbe63fd5 fix(drying): don't stop a running AMS dry on an unreliable humidity re-check (#1892)
Auto-drying stopped manually started (and pre-restart) AMS drying cycles
    after exactly 30 minutes. The already-drying branch in _check_auto_drying()
    applied a humidity-based auto-stop despite its own "track but don't stop"
    comment, and the humidity re-check is unreliable: RH drops steeply in heated
    air, so the sensor reads ~15-20% within minutes of the dryer starting even
    with saturated filament. humidity <= threshold was thus effectively always
    true, and the _min_drying_seconds=1800 floor pinned the stop to the 30-minute
    mark. This also truncated Bambuddy's own preset-duration dries.

    Remove the humidity-based early-stop entirely: a running dry now runs to its
    configured duration (firmware stops it). Scheduling stops (print priority,
    queue no longer needing the dry) are unchanged via _stop_drying(). Drop the
    now-unused _min_drying_seconds.
2026-07-07 11:03:25 +02:00
..