maziggy 0f68039416 Fix: AMS drying popover no longer renders off the bottom of the viewport (#1447 part 1)
The flame-icon onClick on PrintersPage computed popover position as a
  fixed { top: rect.bottom + 4, left: Math.max(8, rect.right - 240) }
  with no viewport-overflow check. The flame icon sits at the bottom of
  the AMS info section on the printer card, so on most realistic viewports
  rect.bottom + 4 + popover_height (~320px) overruns viewport.height and
  the popover renders partially or entirely off-screen with the Start
  button unreachable. Reporter (kleinweby, P1S + AMS-HT) worked around it
  via DevTools to confirm the popover was actually there, just clipped.

  Extract a computePopoverPosition() helper in utils/popoverPosition.ts:
  - defaults to below + right-aligned to the trigger (preserves the
    original visual layout when there's room),
  - flips ABOVE the trigger when below would overflow AND above fits,
  - stays below in the degraded case (popover taller than the viewport) —
    at least the top is visible and the user can scroll inside the
    popover; flipping to a top-clipped position would lose the action
    buttons too,
  - clamps the left coordinate so a trigger near either viewport edge
    can't push the popover off-screen horizontally either.

  Both PrintersPage callsites (the compact AMS row at :3498 and the
  dual-nozzle layout at :4011) route through the helper.

  This is part 1 of #1447. The functional drying bug — printer receives
  the ams_filament_drying MQTT command, ACKs it, but never starts/stops
  drying on Bambuddy's request while the printer's own touchscreen works
  — is NOT addressed here. Diagnosing it needs the printer's actual
  response payload (whether result: "fail" and the specific reason code),
  which bambu_mqtt.py:918 currently doesn't log for ams_filament_drying.
  Punted to a follow-up where I'll extend the existing extrusion_cali_* /
  ams_filament_setting payload-logging path at :919-920 to cover
  ams_filament_drying too, ask the reporter to retry, and fix the
  command side based on what the printer actually returns.
2026-05-20 10:00:15 +02:00
..