maziggy 04e64ffde1 Fix SpoolBuddy scale tare & calibration not being applied
The tare and calibrate buttons on the Settings page queued commands
  but never executed them due to five broken links:

  1. Daemon received tare command but never called scale.tare()
  2. No endpoint to persist tare offset back to backend DB
  3. Heartbeat never called scale.update_calibration()
  4. Heartbeat response with stale values overwrote new tare to zero
  5. set-factor used DB tare_offset (stale/zero), producing wrong
     calibration factor — empty scale showed ~5000g

  Fixed daemon to execute tare, persist result, and propagate
  calibration. Calibration step now captures raw ADC at tare time
  and sends it with step 2, making factor computation self-contained.

  Replaced calibration weight input with compact touch numpad for
  the RPi kiosk's 1024x600 touchscreen (no physical keyboard).
2026-02-28 09:51:51 +01:00
..