The hourly AMS sensor recorder dispatched humidity and temperature alarms for every unit above threshold without checking whether the unit was actually loaded. Empty AMS units still report ambient readings, so users with one loaded + one empty AMS got useful alarms for the loaded one and hourly noise for the empty one. Disabling the whole alarm category killed both — not a real choice. New _ams_has_filament helper inspects tray_exist_bits (hex bitmap, "0" = empty) with fallback to the tray array's tray_type strings for shapes where the bitmap is missing. The recorder gates the alarm dispatch on this check per-AMS-unit, so a multi-AMS printer with one loaded + one empty still alarms on the loaded one. Sensor history still records regardless of the gate so the System page humidity charts stay continuous — only the outbound notification is suppressed. 9 unit tests cover the bitmap-zero case, bitmap-missing fallback, garbage/blank/int bitmap edges, and defensive malformed tray.