mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-09-30 03:01:21 +02:00
The Statistics page reported "Gesamt" (All Time) kWh correctly but showed
zero for Today/Week/Month in total-consumption mode. Two bugs drove it:
1. The starting plug counter was kept in an in-memory dict
`_print_energy_start` that was lost on any backend restart mid-print, so
the per-print `energy_kwh` delta silently never got computed. The stats
endpoint's fallback path `SUM(PrintArchive.energy_kwh)` therefore summed
to zero for users running in total mode.
2. Total-consumption mode has no per-print delta by design — it includes
idle/preheat/standby — so the fallback to archive rows was the wrong
strategy even when the data existed.
Fix, in two parts:
- Persist `energy_start_kwh` on the archive row and read it back from a
fresh session at print end. Deletes `_print_energy_start` and its 5
call sites, replacing them with a single `_record_energy_start()` helper.
Per-print tracking is now restart-resilient regardless of tracking mode.
- Add hourly `smart_plug_energy_snapshots` table + `_snapshot_loop()` in
SmartPlugManager. Rewrote the `/archives/stats` energy branch as
`_sum_snapshot_deltas()` which computes per-plug
`max(0, last-in-range - baseline)` where baseline is the latest snapshot
at or before the range start, falling back to the earliest-ever snapshot
and signalling `energy_data_warming_up` when no pre-range baseline
exists (fresh upgrade). MQTT plugs are skipped from snapshots since they
only report "today" and have no lifetime counter.
Frontend: QuickStatsWidget renders an AlertTriangle next to Energy Used /
Energy Cost with a tooltip when `energy_data_warming_up` is true, so the
"low values right after upgrading" situation is explained in-product.
Fully localised across 7 UI languages.
Tests: new backend unit tests cover the snapshot delta arithmetic
(baseline/endpoint, counter reset clamp, multi-plug, warming-up fallback,
endpoint windowing), per-print restart resilience via expunge_all, and the
snapshot task lifecycle (start idempotent, stop cancels). Frontend tests
assert the warning icon appears only when the flag is set and only on the
energy tiles.
Docs: updated `CHANGELOG.md`, `README.md`, wiki `features/energy.md`,
wiki `features/statistics.md`, and website `features.html` with the new
behaviour and warming-up explanation.
200 lines
8.2 KiB
Python
200 lines
8.2 KiB
Python
"""Tests for #941 — date-range energy in total consumption mode + restart-resilient per-print tracking.
|
|
|
|
Covers:
|
|
- `_sum_snapshot_deltas()`: correct (endpoint - baseline) arithmetic
|
|
- Counter-reset clamp, warming-up flag, missing-endpoint handling
|
|
- Restart resilience: per-print `energy_start_kwh` persists across a
|
|
"simulated restart" (new session/process), so the print-end handler can
|
|
still compute the delta.
|
|
"""
|
|
|
|
from datetime import datetime, timedelta, timezone
|
|
|
|
import pytest
|
|
from sqlalchemy import select
|
|
|
|
from backend.app.api.routes.archives import _sum_snapshot_deltas
|
|
from backend.app.models.archive import PrintArchive
|
|
from backend.app.models.smart_plug_energy_snapshot import SmartPlugEnergySnapshot
|
|
|
|
|
|
def _snap(plug_id: int, recorded_at: datetime, kwh: float) -> SmartPlugEnergySnapshot:
|
|
return SmartPlugEnergySnapshot(plug_id=plug_id, recorded_at=recorded_at, lifetime_kwh=kwh)
|
|
|
|
|
|
class TestSumSnapshotDeltas:
|
|
@pytest.mark.asyncio
|
|
async def test_returns_zero_when_no_plugs(self, db_session):
|
|
total, warming = await _sum_snapshot_deltas(db_session, dt_from=None, dt_to=None)
|
|
assert total == 0.0
|
|
assert warming is False
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_simple_delta_with_baseline_and_endpoint(self, db_session, smart_plug_factory):
|
|
plug = await smart_plug_factory(name="A")
|
|
# Baseline sits before the range, endpoint inside the range.
|
|
t0 = datetime(2026, 4, 1, 0, 0, tzinfo=timezone.utc)
|
|
db_session.add(_snap(plug.id, t0, 100.0)) # baseline
|
|
db_session.add(_snap(plug.id, t0 + timedelta(days=2), 115.0)) # endpoint
|
|
await db_session.commit()
|
|
|
|
range_start = t0 + timedelta(days=1)
|
|
range_end = t0 + timedelta(days=3)
|
|
total, warming = await _sum_snapshot_deltas(db_session, dt_from=range_start, dt_to=range_end)
|
|
|
|
assert total == pytest.approx(15.0)
|
|
assert warming is False
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_warming_up_when_no_baseline_before_range(self, db_session, smart_plug_factory):
|
|
plug = await smart_plug_factory(name="A")
|
|
# All snapshots happen AFTER range_start — simulates fresh upgrade.
|
|
t0 = datetime(2026, 4, 10, 12, 0, tzinfo=timezone.utc)
|
|
db_session.add(_snap(plug.id, t0, 500.0)) # first snapshot ever (fallback baseline)
|
|
db_session.add(_snap(plug.id, t0 + timedelta(hours=6), 502.0)) # endpoint
|
|
await db_session.commit()
|
|
|
|
range_start = datetime(2026, 4, 10, 0, 0, tzinfo=timezone.utc) # before any snapshot
|
|
range_end = datetime(2026, 4, 10, 23, 59, tzinfo=timezone.utc)
|
|
|
|
total, warming = await _sum_snapshot_deltas(db_session, dt_from=range_start, dt_to=range_end)
|
|
|
|
assert total == pytest.approx(2.0) # 502 - 500
|
|
assert warming is True
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_counter_reset_is_clamped_to_zero(self, db_session, smart_plug_factory):
|
|
plug = await smart_plug_factory(name="A")
|
|
t0 = datetime(2026, 4, 1, 0, 0, tzinfo=timezone.utc)
|
|
db_session.add(_snap(plug.id, t0, 1000.0)) # baseline
|
|
# Counter reset — endpoint is lower than baseline (plug replaced, firmware reset, ...)
|
|
db_session.add(_snap(plug.id, t0 + timedelta(days=2), 5.0))
|
|
await db_session.commit()
|
|
|
|
total, warming = await _sum_snapshot_deltas(
|
|
db_session,
|
|
dt_from=t0 + timedelta(days=1),
|
|
dt_to=t0 + timedelta(days=3),
|
|
)
|
|
|
|
assert total == 0.0
|
|
assert warming is False
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_multiple_plugs_are_summed(self, db_session, smart_plug_factory):
|
|
plug1 = await smart_plug_factory(name="A", ip_address="10.0.0.1")
|
|
plug2 = await smart_plug_factory(name="B", ip_address="10.0.0.2")
|
|
t0 = datetime(2026, 4, 1, 0, 0, tzinfo=timezone.utc)
|
|
# plug1: 100 -> 110 (delta 10)
|
|
db_session.add(_snap(plug1.id, t0, 100.0))
|
|
db_session.add(_snap(plug1.id, t0 + timedelta(days=2), 110.0))
|
|
# plug2: 50 -> 55 (delta 5)
|
|
db_session.add(_snap(plug2.id, t0, 50.0))
|
|
db_session.add(_snap(plug2.id, t0 + timedelta(days=2), 55.0))
|
|
await db_session.commit()
|
|
|
|
total, warming = await _sum_snapshot_deltas(
|
|
db_session,
|
|
dt_from=t0 + timedelta(days=1),
|
|
dt_to=t0 + timedelta(days=3),
|
|
)
|
|
|
|
assert total == pytest.approx(15.0)
|
|
assert warming is False
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_plug_with_no_snapshots_signals_warming(self, db_session, smart_plug_factory):
|
|
# Plug exists but never snapshotted (yet).
|
|
await smart_plug_factory(name="A")
|
|
t0 = datetime(2026, 4, 1, 0, 0, tzinfo=timezone.utc)
|
|
|
|
total, warming = await _sum_snapshot_deltas(
|
|
db_session,
|
|
dt_from=t0,
|
|
dt_to=t0 + timedelta(days=1),
|
|
)
|
|
|
|
assert total == 0.0
|
|
assert warming is True
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_endpoint_picks_last_snapshot_at_or_before_range_end(self, db_session, smart_plug_factory):
|
|
plug = await smart_plug_factory(name="A")
|
|
t0 = datetime(2026, 4, 1, 0, 0, tzinfo=timezone.utc)
|
|
db_session.add(_snap(plug.id, t0, 100.0)) # baseline
|
|
db_session.add(_snap(plug.id, t0 + timedelta(days=1), 105.0)) # inside range
|
|
db_session.add(_snap(plug.id, t0 + timedelta(days=5), 130.0)) # AFTER range_end — must be ignored
|
|
await db_session.commit()
|
|
|
|
total, _warming = await _sum_snapshot_deltas(
|
|
db_session,
|
|
dt_from=t0 + timedelta(hours=12),
|
|
dt_to=t0 + timedelta(days=2),
|
|
)
|
|
|
|
# Baseline is last snapshot <= range_start → the t0 one at 100
|
|
# Endpoint is last snapshot <= range_end → the day-1 one at 105
|
|
assert total == pytest.approx(5.0)
|
|
|
|
|
|
class TestPerPrintRestartResilience:
|
|
"""#941: per-print energy tracking survives a mid-print backend restart.
|
|
|
|
The critical change: `energy_start_kwh` is stored on the archive row, not
|
|
in an in-memory dict. A new DB session should still be able to read it.
|
|
"""
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_energy_start_kwh_persists_to_db(self, db_session, printer_factory):
|
|
printer = await printer_factory()
|
|
archive = PrintArchive(
|
|
printer_id=printer.id,
|
|
filename="resilience.gcode.3mf",
|
|
print_name="Resilience",
|
|
file_path="archives/test/resilience.gcode.3mf",
|
|
file_size=1000,
|
|
status="printing",
|
|
energy_start_kwh=123.456,
|
|
)
|
|
db_session.add(archive)
|
|
await db_session.commit()
|
|
archive_id = archive.id
|
|
|
|
# Drop the ORM reference and re-fetch, simulating a fresh session
|
|
# (the situation we'd be in after a backend restart).
|
|
db_session.expunge_all()
|
|
result = await db_session.execute(select(PrintArchive).where(PrintArchive.id == archive_id))
|
|
reloaded = result.scalar_one()
|
|
|
|
assert reloaded.energy_start_kwh == pytest.approx(123.456)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_energy_kwh_delta_computes_from_persisted_start(self, db_session, printer_factory):
|
|
"""Simulates the background energy calc reading from DB instead of a dict."""
|
|
printer = await printer_factory()
|
|
archive = PrintArchive(
|
|
printer_id=printer.id,
|
|
filename="delta.gcode.3mf",
|
|
print_name="Delta",
|
|
file_path="archives/test/delta.gcode.3mf",
|
|
file_size=1000,
|
|
status="completed",
|
|
energy_start_kwh=200.0,
|
|
)
|
|
db_session.add(archive)
|
|
await db_session.commit()
|
|
|
|
# Emulate the end-of-print calculation: plug currently reads 203.4 kWh
|
|
ending_kwh = 203.4
|
|
assert archive.energy_start_kwh is not None
|
|
archive.energy_kwh = round(ending_kwh - archive.energy_start_kwh, 4)
|
|
archive.energy_cost = round(archive.energy_kwh * 0.30, 3)
|
|
await db_session.commit()
|
|
|
|
# Re-read and verify
|
|
db_session.expunge_all()
|
|
result = await db_session.execute(select(PrintArchive).where(PrintArchive.id == archive.id))
|
|
reloaded = result.scalar_one()
|
|
assert reloaded.energy_kwh == pytest.approx(3.4)
|
|
assert reloaded.energy_cost == pytest.approx(1.02)
|