Bambu sends two humidity fields that are not the same quantity. humidity_raw is relative humidity in percent; humidity is a 1-5 drop index, and it runs the other way -- OpenBambuAPI's push_info sample pairs "humidity:30%" with "humidity_idx:4", so a high index means dry where a high percentage means wet. Four call sites used the index whenever no percentage arrived. A unit sending only the index therefore rendered as "2%" in the green band while being the second-wettest of the five steps, charted an average of index values as a percentage, and sat under every humidity threshold forever, since no index can reach one -- the alarm and auto-drying could not fire for such a unit at all. - utils/ams_humidity: one leaf helper, a percentage or None. The index is never converted; None is what every caller already handles. - routes/printers, printer_manager, print_scheduler, main, bambu_mqtt: all five readings go through it, so the card, the websocket, the chart, the alarm and auto-drying cannot answer differently. - main: a unit that reports the index and no usable percentage says so once per unit in the log, with its firmware versions requested. No supported printer is known to do this, and "known" is doing work there -- the alternative is a card that goes blank with no trace. Three faults found while checking what else those paths touched: - main: humidity_raw=float(x) if x else None stored NULL for a numeric 0% while writing 0.0 to humidity on the same row. - main: that same expression was unguarded, unlike the parse above it, so a non-numeric humidity_raw raised inside record_ams_history and aborted the pass for every printer, not just the one that sent it. - routes/ams_history: the averages were tested for truthiness, so a window averaging exactly 0 reported no average while the min and max beside it reported 0.0. An affected unit now reports no humidity rather than a number that means the opposite: the indicator is hidden, the chart leaves a gap, the alarm and auto-drying skip the unit. Temperature is untouched. Auto-drying's outcome is unchanged either way -- an index could never cross the threshold -- so only the intent moves. No supported printer is known to be affected; the report came from an install running X1Plus, which Bambuddy does not support. Verified against 7927 recorded samples from seven AMS units including an AMS-HT: not one used the fallback. Two percentages that did fall through to the index no longer do -- a reading with a decimal point, and "38.0", which int() rejected.
41 lines
1.7 KiB
Python
41 lines
1.7 KiB
Python
"""Shared reading of an AMS unit's humidity.
|
|
|
|
Bambu sends two humidity fields and they are not the same quantity.
|
|
``humidity_raw`` is relative humidity in percent. ``humidity`` is a 1-5 drop
|
|
index, and it runs the other way: OpenBambuAPI's push_info sample carries both
|
|
in one line -- ``ams0 temp:18.4;humidity:30%;humidity_idx:4`` -- so a high index
|
|
means dry where a high percentage means wet.
|
|
|
|
Falling back from one to the other therefore does not degrade, it inverts.
|
|
Index 2 rendered as "2%" reads as the driest a unit can be while the unit is in
|
|
fact the second-wettest of the five steps, and no index can ever exceed a
|
|
percentage threshold, so the humidity alarm and auto-drying silently never fire
|
|
for such a unit (#3140). A unit that reports no percentage has no percentage:
|
|
this returns ``None``, which every caller already treats as "no reading" -- the
|
|
card hides the indicator, the alarm and auto-drying skip the unit, and the
|
|
history chart leaves a gap.
|
|
|
|
Kept as a leaf module like ``ams_drying``: nothing here imports from the app.
|
|
"""
|
|
|
|
from collections.abc import Mapping
|
|
from typing import Any
|
|
|
|
|
|
def ams_humidity_percent(ams_data: Any) -> float | None:
|
|
"""Relative humidity in percent for one AMS unit, or ``None``.
|
|
|
|
``None`` covers every case where the unit did not report a usable
|
|
percentage, including the units that send only the 1-5 index -- which is
|
|
deliberately never converted. See the module docstring.
|
|
"""
|
|
if not isinstance(ams_data, Mapping):
|
|
return None
|
|
raw = ams_data.get("humidity_raw")
|
|
if raw is None:
|
|
return None
|
|
try:
|
|
return float(raw)
|
|
except (TypeError, ValueError):
|
|
return None # Unparseable reading — not a licence to use the index
|