The H2C dual nozzle variant reports model code O1C2 via MQTT, but only
O1C was recognized. This caused the camera to use the wrong protocol
(chamber image on port 6000 instead of RTSP on port 322), producing a
reconnect loop. Added O1C2 to all model ID maps across 8 files.
- Add H2D Pro option to printer model dropdowns (add/edit modals)
- Support both O1E and O2D internal codes for H2D Pro compatibility
- Add O2D to RTSP-capable and chamber temp supported models
- Add H2DPRO variant to firmware check mapping
- Add H2D Pro and X1E to bug report issue template
Closes#192
Root Cause: P2S (and other newer models) may report their model as internal codes (e.g., "N7" for P2S) rather than display names in MQTT/SSDP responses. The camera code
only checked for display names like "P2S", causing it to incorrectly use the chamber image protocol (for A1/P1) instead of RTSP.
Internal Code Mapping:
BL-P001 → X1/X1C (RTSP)
C13 → X1E (RTSP)
O1D → H2D (RTSP)
O1C → H2C (RTSP)
O1S → H2S (RTSP)
O1E → H2D Pro (RTSP)
N7 → P2S (RTSP)
C11 → P1P (Chamber)
C12 → P1S (Chamber)
N2S → A1 (Chamber)
N1 → A1 Mini (Chamber)
Closes#127
prints (not just completed), matching get_printer_total_hours behavior
- Add option to keep or delete archives when deleting a printer
- Custom maintenance types no longer auto-assign to all printers
- Add UI to manually assign/remove custom maintenance types per printer
- Add backend endpoints for assigning types to printers and removing items
- Exclude static/assets from large file pre-commit check
- Fix A1/P1 camera streaming with extended timeouts and lower FPS cap