Every field that takes a chamber target stopped at 60: the per-filament
chamber map and per-print override in Preheat & Heat Soak, the chamber
quick-select presets, and the printer-card chamber control. 60 is the
X1E's ceiling and the X1E was the only heated-chamber model when that
limit was written; the H2 series and X2D heat to 65, so the top of their
range was unreachable.
The ceiling now lives in one constant per side (MAX_CHAMBER_TEMP_C in
backend/app/utils/printer_models.py and frontend/src/utils/printer.ts)
rather than as a literal at each call site. X1E firmware clamps a higher
request to its own maximum, so a shared ceiling is safe.
Also fixes a live bug at PrintersPage.tsx:7985: parsePresetTriple was
bounded to 60 there, and it rejects the whole triple on any out-of-range
entry, so a saved 65 preset would have silently reverted the printer
card to the defaults while Settings still showed 65.
Bed levelling, flow calibration, and nozzle-offset calibration were on/off
only, so the sole way to run bed levelling was to force a full level before
every print. Bambu Studio has always offered a third "Auto" state that lets
the printer skip the calibration when it was done recently -- the state most
users actually want. Make these three options tri-state (off/on/auto),
defaulting to auto, and leave vibration/layer-inspect/timelapse as on/off
(Bambu Studio exposes no auto for those).
Wire encoding follows Bambu Studio's source exactly: each option sends a JSON
bool (true only for "on") plus a companion int -- off=0, on=1, auto=2. The
bool fields stay booleans (the #1478 H2S regression); only the companion int
widened from {0,1} to {0,1,2}. #1721's observation that stage 8/39 stays
queued when sending 2 is the auto contract (queued, skipped at runtime if
recent), not a broken "off".
- schemas: TriState = Literal[off/on/auto] with a BeforeValidator coercing
legacy bool / 0-1 / true-false so old clients and un-migrated rows validate
- model + migration: boolean columns -> String; SQLite via column affinity +
data backfill, PostgreSQL via ALTER COLUMN TYPE guarded on information_schema
(verified on both dialects); settings rows normalised true/false -> on/off
- MQTT: start_print takes the tri-state strings and emits the paired bool+int
- Virtual Printer: reconstructs the slicer's auto/on/off from the int companion
(auto_bed_leveling / extrude_cali_flag) in both capture paths
- frontend: CalibrationMode type; off/auto/on segmented controls in the print
dialog, queue bulk-edit, and Settings -> Workflow; calibrationMode_* strings
in all 11 locales
The app was built dark-first, so hundreds of hardcoded Tailwind semantic
text/icon utilities at light shades (text-amber-400, text-blue-300, ...) had
no dark: variant. With darkMode:'class' they applied in light theme too,
producing washed-out text on pale tints and white cards — including the three
reported spots (AMS Drying banner, Archives no-3MF warning, debug-logging
banner). Give each a theme-aware pair: a darker readable shade in light theme
with the original pinned to dark:, so dark theme is unchanged. ~100 files.
The bambu-* CSS-variable palette (self-correcting) and the dark-only SpoolBuddy
kiosk are left untouched. Plain text-white is already theme-aware via the
existing index.css .text-white override, so it needed no changes.
New scheduler stage that heats the bed (and the chamber, on supported
printers) and holds at temperature before each queued print starts —
the heat-soak engineering filaments need for adhesion and warp
control. Bambuddy waits between FTP upload and start_print, so the
soak runs while the printer is otherwise idle. M191 is silently
ignored by Bambu firmware, so doing this at the orchestration layer
is the only place it works.
Resolution order at dispatch:
1. PrintQueueItem.preheat_override ∈ {inherit, on, off}.
'off' skips entirely; 'inherit' falls back to the global
preheat_enabled toggle; 'on' forces the stage even when the
global is off.
2. chamber_target = item.preheat_chamber_target_override
?? max(filament_map[normalize(t.tray_type)] for loaded slots)
?? 0.
Mixed PA+PLA picks PA's 50 (max-across-slots — PA's chamber
requirement is binding, PLA doesn't suffer being warm). PLA-only
derives 0 and skips the chamber phase automatically.
3. Three hardware tiers for chamber heat:
- Active chamber heater (H2C/H2D/H2D Pro/H2S/X2D/X1E) → M141 +
chamber-sensor wait
- Chamber sensor only (X1C/P2S) → no M141, passive bed-radiation
wait with hard max-wait cap
- No chamber sensor (P1S/P1P/A1/A1 Mini) → bed + soak timer only
4. Airduct flap (H2C/H2D/H2D Pro/H2S/X2D/P2S) auto-switches to
match the chamber target — heating mode for engineering
filaments, cooling mode for PLA. Bambu firmware does NOT
auto-switch the flap with M141, so without this an ABS print
on a previously-cooling flap fights the open exhaust, and a
PLA print on a previously-hot flap recirculates ABS heat.
Idempotent: only fires set_airduct_mode when current ≠ desired.
Settings → Workflow → Queue & Dispatch → Preheat & Heat Soak card:
master enable toggle (default off — disabled installs see no change),
per-filament chamber-target editor (replaces a single global int that
shipped in the first cut and couldn't serve PA + PLA in the same
config), preheat_max_wait_seconds, preheat_soak_seconds. The Print
Options panel in PrintModal gets a Preheat sub-section with the
tri-state Inherit/On/Off control and an optional chamber-target
override input.
DB migration: PrintQueueItem gains preheat_override VARCHAR(10)
DEFAULT 'inherit' and preheat_chamber_target_override INTEGER NULL.
Idempotent via _safe_execute. Existing rows behave exactly as before
the migration.
Best-effort throughout: printer drops, refused M141 or set_airduct,
missing bed temp, lost MQTT state mid-wait all log and return cleanly.
Normal upload + start path runs after this returns regardless.
Bambuddy's project_file MQTT payload hardcoded "nozzle_offset_cali": 2 (skip),
giving users on H2D / H2D Pro / H2C / X2D no way to control the same toggle
BambuStudio exposes. Critical for diamond-nozzle setups that must keep the
calibration off.
start_print() now takes a nozzle_offset_cali kwarg; the value is encoded as
1 (run) or 2 (skip) and gated on is_dual_nozzle so single-nozzle machines
always send 2 even if a stale flag arrives. The kwarg threads through
printer_manager, both background_dispatch sites, and print_scheduler so
every dispatch path respects the per-item setting.
print_queue gains a nozzle_offset_cali column (DEFAULT TRUE, is_sqlite()
branch for Postgres BOOLEAN). Settings default key default_nozzle_offset_cali
defaults to TRUE to match BambuStudio. Schemas updated across print_queue,
library FilePrintRequest, archive ReprintRequest, settings.
PrintModal renders the new toggle only when the selected printer is dual-
nozzle (printer-mode: nozzle_count===2; model-mode: DUAL_NOZZLE_MODELS).
SettingsPage default-print-options row + QueuePage bulk-edit tri-state both
hide unless any registered printer is dual-nozzle. Labels reuse the existing
settings.default* keys so the only new i18n strings are
settings.defaultNozzleOffsetCali / Desc and queue.bulkEdit.nozzleOffsetCali
- real translations in all 11 locales.