The GET /api/v1/support/debug-logging endpoint returned 500 when the
database contained a timezone-aware enabled_at timestamp written by
0.2.2b3. The duration calculation mixed offset-aware and offset-naive
datetimes, raising TypeError. Strip tzinfo when reading the stored value.
Two bugs prevented bed cooldown notifications from working:
1. Stale temperature data: After print completion, the printer sends
partial MQTT updates without bed_temper, leaving the cached value
frozen at the end-of-print temperature. The monitor polled for 30
minutes seeing the stale value above threshold, then timed out.
Fix: send periodic pushall commands to force fresh temperature data.
2. Missing fields in provider create endpoint: on_bed_cooled and all 7
queue event toggles were omitted from the NotificationProvider
constructor, silently discarding user selections on create (update
worked fine via dynamic setattr).
Also added debug logging to the bed cooldown polling loop.
The debug logging banner displayed a negative elapsed time (e.g. "-60m -59s")
equal to the server's UTC offset. datetime.now() stored local time without a
timezone indicator, but the frontend's parseUTCDate() interpreted it as UTC.
Use datetime.now(tz=timezone.utc) consistently for storing, parsing, and
comparing the enabled_at timestamp.
* Enhance link spool functionality with additional printer and AMS details
* Refactor linkSpool function to accept detailed context object for improved spooling integration
* Enhance LinkSpoolModal to include amsName in props and linkSpool mutation for improved functionality
* Add amsName prop to PrinterCard for enhanced spool linking functionality
* Updates LinkSpoolModal test to work with recent spool location update changes
* Adds clear_location to unlink testing
* Refactor LinkSpoolRequest to remove ams_name and update location generation logic for improved clarity
* Remove amsName from LinkSpoolModal and PrinterCard for cleaner API integration
* Remove amsName from LinkSpoolModal test props and update linkSpool mock response for improved clarity
Two bugs prevented bed cooldown notifications from working:
1. Stale temperature data: After print completion, the printer sends
partial MQTT updates without bed_temper, leaving the cached value
frozen at the end-of-print temperature. The monitor polled for 30
minutes seeing the stale value above threshold, then timed out.
Fix: send periodic pushall commands to force fresh temperature data.
2. Missing fields in provider create endpoint: on_bed_cooled and all 7
queue event toggles were omitted from the NotificationProvider
constructor, silently discarding user selections on create (update
worked fine via dynamic setattr).
Also added debug logging to the bed cooldown polling loop.
The GET /api/v1/support/debug-logging endpoint returned 500 when the
database contained a timezone-aware enabled_at timestamp written by
0.2.2b3. The duration calculation mixed offset-aware and offset-naive
datetimes, raising TypeError. Strip tzinfo when reading the stored value.
* Expanded link logic to accept a generic spool tag (spool_tag, tray_uuid, or tag_uid) and validate 16/32-char hex values, including rejection of all-zero tags. Added a new unlink endpoint that clears Spoolman extra.tag for a given spool ID.
* Updated the link validation expectation to match the new 16-or-32-hex rule. Added an integration test for the new unlink endpoint to verify extra.tag is cleared and success is returned.
* Updated the link API call to send spool_tag instead of tray_uuid. Added a new unlinkSpool API helper that calls the new backend unlink route.
* Switched modal data source from inventory spools to Spoolman unlinked spools so the list matches the backend response you shared. Updated the link action to call Spoolman link directly and use trayUuid or tagUid as the slot tag.
* Refactored Spoolman card behavior so actions render correctly across linked/unlinked cases, and added support for an Unlink from Spoolman button under Open in Spoolman. Final UI rule now hides Unlink for Bambu Lab filament and shows it only for non-Bambu linked spools.
* Added fallback slot-tag generation so untagged slots can still be linked/unlinked reliably and linked spool lookups work consistently across AMS, AMS-HT, and external trays. Wired a new unlink mutation and passed per-slot unlink callbacks into the hover card, with query invalidation for linked/unlinked spool caches after unlink.
* Added/updated the noTrayUuid message to reflect that either tray UUID or tag UID is required when no slot tag is available. This keeps error text aligned with the new tag fallback and modal behavior.
* Added noTrayUuid message in the other languages. The translation was done using Google Translate.
* Updated LinkSpoolModal tests to use Spoolman API instead of inventory API, with new UnlinkedSpool data structure and Select Spool UI text.
* Adds hashSerialToHex32, uses new function in getFallbackSpoolTag and updates all uses. This ensures we're generating a fallback spool tag using the printers serial number rather than the database ID for consistency.
* Removes 'import json' from unlink_spool and moves to the top of the file.
* Removes hasUnlinkedSpools and related references since it's no longer used
* Removes noTrayUuid from translations and references in components.
* Adds confirmation dialog before fully unlinking spool from Spoolman
* Adds unlinkConfrimTitle and unlinkConfirmMessage. All languages other than English were done using Google Translate
* Fixes unlink toast to use dedicated unlinkSuccess and unlinkFailed keys.
* Changes tag priority on spoolTag, fixes type error by adding non-null assertion to spoolTag
* Switches around tag_uid and tray_uuid on const trayTag
---------
Co-authored-by: MartinNYHC <mz@v8w.de>
The debug logging banner displayed a negative elapsed time (e.g. "-60m -59s")
equal to the server's UTC offset. datetime.now() stored local time without a
timezone indicator, but the frontend's parseUTCDate() interpreted it as UTC.
Use datetime.now(tz=timezone.utc) consistently for storing, parsing, and
comparing the enabled_at timestamp.
Sends persistent notifications to the HA dashboard using the existing
HA connection from Settings. Zero config — just select "Home Assistant"
as provider type. Users can forward notifications to mobile via HA
automations.
Large Hueforge 3MF files (~28 MB) can't be downloaded from the
printer's FTP server within the previous 120s max timeout, especially
during active printing. Added 180s and 300s timeout options to the
FTP settings dropdown.
Three interrelated bugs in AMS info field parsing caused AMS units
to appear on the wrong nozzle on H2D dual-nozzle printers:
1. Info field parsed as decimal instead of hex (BambuStudio uses
std::stoull with base 16)
2. Extruder ID extracted as 1-bit instead of 4-bit field (bits 8-11)
3. Partial MQTT updates replaced the full extruder map instead of
merging into it
home_flag bit 18 was incorrectly interpreted as "wired/ethernet
connection", causing the ethernet badge to always show — even on
printers without an ethernet port (e.g. A1, P1S). This hid the
WiFi signal indicator entirely.
Removed the wired_network field and ethernet badge UI. The WiFi
signal badge now shows correctly whenever the printer reports
signal strength.
* Added "Force Color Match" feature to filament override
* Update settings.py
* Update settings.py
* Label updates for warnings and checkbox case
* Initial plan
* Add noMatchingMaterial i18n translations to all 7 locale files
Co-authored-by: cadtoolbox <12723486+cadtoolbox@users.noreply.github.com>
* Use {{material}} interpolation in noMatchingMaterial; populate from filament_overrides with getColorName
Co-authored-by: cadtoolbox <12723486+cadtoolbox@users.noreply.github.com>
* Updates for PR#625 comments
* Added "Force Color Match" feature to filament override
* Update settings.py
* Update settings.py
* Label updates for warnings and checkbox case
* Initial plan
* Add noMatchingMaterial i18n translations to all 7 locale files
Co-authored-by: cadtoolbox <12723486+cadtoolbox@users.noreply.github.com>
* Use {{material}} interpolation in noMatchingMaterial; populate from filament_overrides with getColorName
Co-authored-by: cadtoolbox <12723486+cadtoolbox@users.noreply.github.com>
* Updates to PrintersPage and QueuePage
* Update QueuePage.tsx
* Rebase to 0.2.2b3
* Fix compile errors with FilamentOverride
* Updates for PR#625 comments
https://github.com/maziggy/bambuddy/pull/625#pullrequestreview-3908738261
* Fix force color match default, loadedFilamentTypes bug, remove dead translations
---------
Co-authored-by: copilot-swe-agent[bot] <198982749+Copilot@users.noreply.github.com>
Co-authored-by: cadtoolbox <12723486+cadtoolbox@users.noreply.github.com>
Co-authored-by: MartinNYHC <mz@v8w.de>
Virtual printers in Queue mode now have an "Auto-dispatch" setting.
When enabled (default), prints start automatically — preserving current
behavior. When disabled, prints are added with manual_start so they
wait for manual dispatch from the queue UI.
The FTP upload skipped reading the server's "Transfer complete"
confirmation, sending the print command before the file was flushed
to the SD card. Now waits for the 226 response with a 60s timeout.
Checkbox selection + "Delete Selected" button in Settings > Filament
for both Spool Catalog and Color Catalog. Adds POST bulk-delete
endpoints and translations for all 7 locales.
P2S uses hardened steel rods, not carbon fiber. Move P2S from
carbon rod classification to new steel_rod category with its own
"Lubricate Steel Rods" / "Clean Steel Rods" maintenance tasks.
Add {eta} template variable showing wall-clock completion time
(e.g. "15:53" or "3:53 PM") to print_start, print_progress, and
queue_job_started notifications. Respects the user's time_format
setting (12h/24h). The existing {estimated_time} variable continues
to show duration ("1h 23m").
visibility into AMS spool assignments on printer cards without exposing
the full Inventory page (#635). The list_assignments endpoint now
requires this new permission instead of inventory:read. All default
groups (Administrators, Operators, Viewers) include it for backward
compatibility.
Closes#634
Files added to a project from the archive (status="archived") were
incorrectly counted in completed_prints and parts_progress stats.
Only status="completed" (actually printed) now counts toward completion.
All filament mapping dropdowns (single-printer, multi-printer, and
"Print to Any" model-based) showed only the base material type (e.g.
"PLA") without distinguishing subtypes like "PLA Basic" vs "PLA Matte",
making entries with different subtypes but same color look identical.
Backend: Add tray_sub_brands to available-filaments response and include
it in the dedup key so different subtypes of the same color appear as
separate entries.
Frontend: Show tray_sub_brands in FilamentMapping, FilamentOverride, and
PrinterSelector dropdowns, falling back to base type when unset. Add
traySubBrands field to LoadedFilament interface.
Two lazy-load bugs caused greenlet_spawn errors in the RFID auto-assign
flow:
1. create_spool_from_tray set spool.k_profiles=[] AFTER db.flush(),
but assigning to a relationship on a persistent object triggers a
lazy load (SQLAlchemy loads the current collection before replacing).
Moved initialization to BEFORE db.add().
2. spool.assignments was never initialized or eagerly loaded, so
db.add(SpoolAssignment) triggered a back_populates lazy load
outside the async greenlet. Added assignments=[] in create and
selectinload(Spool.assignments) in get_spool_by_tag.
Also added exc_info=True to error handlers for full tracebacks, and
19 new tests including greenlet regression tests that reproduce the
exact failure.
enum.StrEnum was added in Python 3.11, but the documented minimum is
3.10. Add a compatibility shim in backend/app/core/compat.py that falls
back to (str, Enum) on older versions. Updated all 5 import sites and
lowered pyproject.toml target-version to py310.
Bambu printers only support plain RSA key exchange ciphers
(AES256-GCM-SHA384, AES128-GCM-SHA256), but Python's OpenSSL 3.x
defaults exclude them in favor of forward-secrecy (ECDHE/DHE) only.
Add the RSA ciphers to the client SSL context so the TLS proxy can
connect to the printer's bind port (3002).
When the print queue scheduler finds pending items but doesn't start
any, there was no logging to explain why. Added INFO-level summary
after each queue check showing skip reasons (manual_start,
scheduled_future) and busy printer details (state, connected,
plate_cleared). Also added DEBUG-level logging in _is_printer_idle()
for the specific condition that failed.
- Add 12 backend integration tests for AMS labels API (GET/PUT/DELETE,
serial resolution, synthetic key fallback, whitespace handling, validation)
- Add 10 frontend tests for FilamentSlotCircle component (rendering,
border styles, background colors, text contrast inversion)
- Fix ruff W293 trailing whitespace in inventory.py from contributor fix
- Add ams_label model import to test conftest.py
- Update CHANGELOG, README, website features page, and wiki AMS docs
* AMS Labels addition to PrintersPage
* Added database reinitialization for schema migrations on database restore
* Bug fixes and AMS Label persistence updates
* Update database.py to resolve PR conflicts
* PR Comment Resolution
* Resolve conflicts in database.py for PR#570
* Updates to address PR#570 additional comments
* Optimize visibility handling for popup component
* Improve serial key handling in printers.py
Refactor serial key assignment to handle empty AMS serial gracefully.
* Implement error handling in serial number mapping
Add error handling for serial number mapping.
* Add migration to drop old ams_labels table
---------
Co-authored-by: MartinNYHC <mz@v8w.de>
On Windows, process.terminate() on ffmpeg broadcasts CTRL_C_EVENT to
the entire process group, causing uvicorn to shut down. Spawn ffmpeg
with CREATE_NEW_PROCESS_GROUP so cleanup doesn't affect the server.
Floating bug report button submits issues via bambuddy.cool relay (no GitHub
token needed locally). Collects 30s debug logs with printer push_all, sanitizes
all sensitive data, uploads logs as files to GitHub. Screenshot upload/paste/drag
with JPEG compression. Translated into all 7 languages. Includes 21 tests.
Parse home_flag bit 18 (0x00040000) from MQTT to detect ethernet
connections. When set, the printer card shows a green "Ethernet"
badge with a cable icon instead of WiFi signal strength in dBm.
The printer info modal also displays "Ethernet" instead of WiFi
signal details.
The firmware check only mapped display names (e.g., "H2D Pro") to
API keys but not raw SSDP device codes (e.g., "O1E", "O2D"). If a
printer's model was stored as the raw SSDP code, the firmware check
either failed or matched the wrong model — H2D Pro matched against
H2D firmware, showing a false update-available badge.
Add all known SSDP device codes to MODEL_TO_API_KEY so firmware
versions resolve correctly regardless of how the model was stored.
The previous fix only filtered status codes (< 0x4000) from the
print_error field. Firmware can also send the same false positive
through the hms array in MQTT, which had no such filter. Apply the
same < 0x4000 check to the HMS parser so status/phase indicators
are skipped regardless of which MQTT field carries them.
The isSlicedFile() check only matched .gcode or .gcode.3mf extensions,
so archives from .3mf prints (the standard Bambu slicer output) showed
a "SOURCE" badge instead of "GCODE". Since .3mf can be either sliced or
a raw CAD export, now checks the archive's total_layers and
print_time_seconds metadata to distinguish them. Also passes the
original filename when creating archives from file manager prints.
FTP upload: reduce chunk size from 1MB to 64KB for smooth progress bar
updates (~1s intervals instead of 20+ second gaps). Skip voidresp() for
all printer models — H2D delays the 226 response by 30+ seconds after
data transfer, causing a hang at 100%. Add transfer speed and TLS
handshake timing to logs for diagnosing slow connections.
Print/Schedule modal: widen from max-w-lg (512px) to max-w-2xl (672px)
to accommodate long filament profile names like "PLA Support for PETG
PETG Basic @Bambu Lab H2D 0.4 nozzle".
Profiles like "PLA Support for PETG PETG Basic @Bambu Lab H2D" have
filament_type PETG, but both the frontend and backend name parsers
found "PLA" first (iterating material types in order). The MQTT command
sent tray_type=PLA and tray_info_idx=GFL99 (PLA generic), so the
slicer displayed PLA instead of PETG.
- Frontend parsePresetName(): detect "X Support for Y" pattern, extract
material after "Support for"
- Frontend ConfigureAmsSlotModal: prefer corrected parsed material over
stored localPreset.filament_type for tray_type, tray_info_idx, and
temperature fallback
- Backend _parse_material_from_name(): same "Support for" handling for
future profile imports
- Backend assign_spool: prioritize spool.material over lp.filament_type
for generic filament ID lookup
The slicer_binary_path key was left in the settings table from earlier
slicer integration research but is no longer referenced anywhere in the
codebase. Add a startup migration step that deletes orphaned settings
keys so they don't persist in backups.
* feat(queue): show spool grams left in filament slot mapping
* Bumped version
* Add SpoolBuddy AMS slot config, external slots, and dashboard redesign
- AMS page: external spool slots (Ext/Ext-L/Ext-R), click-to-configure
modal on all slots, temperature/humidity threshold-colored indicators,
nozzle L/R badges for dual-nozzle printers, compact AMS-HT layout
- Dashboard: two-column layout with device status + printers list (left)
and current spool card (right), state-colored scale/NFC icons, dashed
border card styling
- Daemon: suppress redundant scale reports (±2g threshold + stability
state change detection) to prevent weight display bouncing
- TopBar: auto-select online printers only, SpoolBuddy logo
* Fix SpoolBuddy daemon crash when read_tag module is missing
NFCReader.__init__ imported read_tag and instantiated PN5180() outside
the try/except block, so a missing module crashed the entire daemon.
Moved the import inside the existing try/except so the daemon gracefully
skips NFC polling — matching the scale reader's existing behavior.
* Fix SpoolBuddy daemon failing to import hardware drivers
The daemon imports read_tag and scale_diag as bare modules, but they
live in spoolbuddy/scripts/ which isn't on sys.path when systemd runs
the daemon. Added scripts/ to sys.path at startup, resolved relative
to the module file. Also moved the read_tag import inside NFCReader's
try/except (was crashing the daemon instead of skipping gracefully)
and demoted hardware-not-available messages from ERROR to INFO.
* Increase scale moving average window to reduce weight bouncing
5 samples at 100ms (500ms window) wasn't enough to smooth NAU7802 ADC
noise — the averaged value still varied by >2g between 1s report
intervals, and the stability state kept flipping, triggering a report
every cycle. Increased to 20 samples (2s window) so noise is smoothed
before reaching the reporting layer.
* Remove stability flipping as scale report trigger
When ADC noise kept the spread hovering around the 2g stability
threshold, the stable flag toggled every cycle, forcing a report with
a slightly different weight each time. Now only actual weight changes
of >=2g trigger reports. The stable flag is still included in each
report for consumers that need it.
* Fix formatting of option elements in FilamentMapping
* Make low stock threshold editable
* Add new filter for low spools
* Update bug report template to require additional fields
* Added toast for invalid imputs with locales, updated inputb field restrictions
* Minor Spoolbuddy frontend improvements
* Updated test_backend.sh
* Updated Spoolbuddy install script to strip down Raspbian
* Updated Spoolbuddy install script
* Add API key auth support to /auth/me for SpoolBuddy kiosk
When Bambuddy auth is enabled, the SpoolBuddy kiosk gets redirected to
the login page because ProtectedRoute requires a user from GET /auth/me,
which only handled JWT tokens. The kiosk daemon already has an API key
but couldn't use it to satisfy the frontend auth check.
- Backend: /auth/me now accepts API keys (Bearer bb_xxx or X-API-Key)
and returns a synthetic admin UserResponse with all permissions
- Frontend: AuthContext reads ?token= from URL on first load, stores in
localStorage, and strips from URL (prevents history/referrer leakage)
- Install script: kiosk URL now includes ?token=${API_KEY}
- Tests: 3 new integration tests (Bearer API key, X-API-Key header,
invalid key rejection)
* SpoolBuddy touch-friendly UI overhaul for 1024x600 kiosk display
Enlarge all interactive elements across 9 SpoolBuddy components to meet
44px minimum tap targets on the RPi touchscreen. Increase nav icons
(20→24px), labels (10→12px), bar heights, section headers, printer
buttons, spool visualizations, fill bars, and status indicators.
Compact the dashboard stats bar and remove the printers card. Add
fullScreen prop to ConfigureAmsSlotModal with two-column layout
(filament list left, K-profile + color right) to eliminate scrolling.
* Minor changes, CSS fixes
* Refactor usageFilter state to remove 'lowstock' option for clarity
* Move var saving to API, add test coverage
* fix: threshold validation and cleanup
* Change test input from '150' to '0'
---------
Co-authored-by: tridev <c.tripod@gmx.ch>
Co-authored-by: MartinNYHC <mz@v8w.de>
Some firmware sends non-zero print_error values (e.g. 0x03000002 →
0300_0002) during normal printing as status/phase indicators. The
parser treated any non-zero value as a real error, triggering
notifications. All known real errors have codes >= 0x4000 (fatal,
warning, prompt ranges). Now skips print_error values where the
low 16 bits are below 0x4000.
Also fix K-profile greenlet error on auto-created RFID spools by
eagerly setting k_profiles=[] after flush in create_spool_from_tray().
create_spool_from_tray() didn't eagerly load the k_profiles
relationship, so auto_assign_spool() triggered a lazy load in async
context when iterating spool.k_profiles. Set k_profiles=[] on new
spools since they can never have K-profiles yet.
Write NTAG213/215/216 tags for third-party spools via the SpoolBuddy
kiosk UI. New "Write" page with three workflows: existing spool, new
spool creation, and tag replacement. Backend encodes 133-byte OpenTag3D
NDEF payloads (material, color, brand, weight, temp). Daemon writes
page-by-page via PN5180 NTAG WRITE command with read-back verification.
Write commands flow through heartbeat polling with WebSocket status
updates. Includes 39 new tests and translations for all 6 languages.
- Redesign settings page with tabbed layout (Device, Display, Scale, Updates)
- Add screen blank timeout: blanks after touch inactivity, tap to wake
- Add CSS brightness filter for HDMI displays (no sysfs on HDMI)
- Add backend `language` field to app settings for server-side persistence
- Sync UI language from backend on kiosk load (separate Chromium instance)
- Top bar clock respects user's time format setting (system/12h/24h)
- Add SpoolBuddy settings translations for all 6 languages (en/de/fr/ja/it/pt-BR)
- Disable Chromium swipe-to-navigate in kiosk install script
- Add `video` group for DSI backlight access