The firmware check only mapped display names (e.g., "H2D Pro") to
API keys but not raw SSDP device codes (e.g., "O1E", "O2D"). If a
printer's model was stored as the raw SSDP code, the firmware check
either failed or matched the wrong model — H2D Pro matched against
H2D firmware, showing a false update-available badge.
Add all known SSDP device codes to MODEL_TO_API_KEY so firmware
versions resolve correctly regardless of how the model was stored.
The firmware update cache stored downloaded files under a mangled name
(e.g. X1C_01_09_00_10.bin) instead of the original filename from
Bambu Lab's CDN. On cache hit the wrong filename was uploaded to the
printer's SD card, so the printer couldn't find the firmware file.
Now caches with the original filename so it's always correct.
H2C was mapped to the "h2d" firmware API key, causing it to check
the H2D firmware page and offer H2D firmware for download. H2C has
its own separate firmware track (01.01.x.x vs H2D's 01.02.x.x).
Changed H2C to use its own "h2c" API key and added the reverse
mapping. Also added missing H2C (O1C) and H2S (O1S) entries to
the printer model ID and 3MF model name maps.
The CodeQL cleanup in "Housekeeping" (2b11efd) bulk-narrowed except
clauses across 50+ files, breaking FTP uploads on ALL printer models.
ftplib.error_perm (550 errors) is not a subclass of ftplib.error_reply,
so diagnose_storage() CWD failures escaped the handler and prevented
STOR from ever executing — causing 100% upload failure and HTTP 500s
on /api/v1/archives/{id}/reprint and /api/v1/library/files/{id}/print.
FTP fixes:
- Remove diagnose_storage() from upload hot path
- Change all except (OSError, ftplib.error_reply) to
except (OSError, ftplib.Error) across bambu_ftp.py
Exception handling reverts (9 files):
- Revert narrowed except clauses back to except Exception in route
handlers and service code where broad catches are intentional
defensive programming (archive parsing, HTTP clients, 3MF/ZIP
processing, Home Assistant, firmware checks)
- Keep narrow exceptions only where safe (single-op blocks like
int(), file.unlink(), socket.close())
- Remove unused XMLParseError imports from archive.py, threemf_tools.py
Closes#287
Simplify always-true authEnabled ternary and localSettings truthiness
checks in SettingsPage.tsx. Remove commented-out auth re-setup guard
and its dead _existing_setting/_user_count queries from auth.py.
Add clarifying comments to firmware_check.py api_key logs (model
identifier, not a secret).
- Add H2D Pro option to printer model dropdowns (add/edit modals)
- Support both O1E and O2D internal codes for H2D Pro compatibility
- Add O2D to RTSP-capable and chamber temp supported models
- Add H2DPRO variant to firmware check mapping
- Add H2D Pro and X1E to bug report issue template
Closes#192
Enables checking and uploading firmware updates for printers operating
in LAN-only mode without Bambu Cloud connectivity.
Features:
- Automatic firmware version checking against Bambu Lab servers
- Orange "Update" badge on printer cards when updates available
- Firmware update modal with version info and release notes
- One-click firmware upload to printer SD card via FTP
- Real-time upload progress (actual bytes transferred)
- Step-by-step instructions for triggering update from printer
- Local firmware caching for faster re-uploads
- Supports all Bambu Lab printer models
New files:
- backend/app/services/firmware_check.py - Version checking service
- backend/app/services/firmware_update.py - Upload orchestration
- backend/app/api/routes/firmware.py - REST API endpoints
Also includes:
- FTP upload progress callback support
- 10-minute upload timeout protection
- Firmware cache directory in .gitignore