1. "Unknown Status (255)" bug
File: backend/app/services/printer_manager.py:291-293
Problem: A1/P1 printers send stg_cur=255 when idle (unlike X1 which uses -1). The code treated 255 as a valid stage number and returned "Unknown stage (255)".
Fix: Changed the condition from if state.stg_cur >= 0: to if 0 <= state.stg_cur < 255: so that 255 is now treated as "no calibration stage" (same as -1).
2. AMS humidity/temp displaced on mobile
File: frontend/src/pages/PrintersPage.tsx:1164-1212
Problem: The AMS row used a rigid horizontal flex layout that didn't adapt to narrow mobile screens, causing humidity/temperature indicators to be displaced.
Fix:
- Added flex-wrap to allow wrapping on very narrow screens
- Added ml-auto to humidity/temp section to keep it right-aligned
- Added max-w-[60px] sm:max-w-none to truncate long filament names on mobile
- Changed gap from fixed gap-3 to responsive gap-2 sm:gap-3
Tests Added
4 new unit tests for get_derived_status_name:
- test_stg_cur_255_returns_none - Verifies A1/P1 idle state
- test_stg_cur_negative_one_returns_none_when_idle - Verifies X1 idle state
- test_valid_stage_returns_name - Verifies valid stages work
- test_stg_cur_zero_returns_printing - Verifies printing state
All 382 tests pass.
- Add getStatusDisplay() helper in frontend to format status nicely
- Add get_derived_status_name() in backend to compute status from:
- stg_cur calibration stages (bed leveling, vibration comp, etc.)
- Temperature data when stg_cur unavailable (heating heatbed/nozzle)
- Include stg_cur and stg_cur_name in WebSocket broadcasts
- Update broadcast status key to detect heating phase changes
Printer cards now show: "Heating heatbed", "Heating nozzle", "Preparing",
"Auto bed leveling", "Cleaning nozzle tip", and 60+ other stage names
instead of just "Printing" or "Idle".
Problem: xcam data was parsed BEFORE _was_running was set to True, so timelapse detection failed when both arrived in the same message.
Fix: Added timelapse detection at two critical points:
# Lines 1375-1381: When entering RUNNING state
if self.state.state == "RUNNING" and current_file:
if not self._was_running:
if self.state.timelapse:
self._timelapse_during_print = True
logger.info(f"[{self.serial_number}] Timelapse detected when entering RUNNING state")
# Lines 1391-1399: When print start detected
if self.state.timelapse:
self._timelapse_during_print = True
logger.info(f"[{self.serial_number}] Timelapse detected at print start")
2. Callback Error Handling (main.py + printer_manager.py)
Problem: The on_print_complete callback was hanging silently - no logs after "Found archive".
Fixes:
- Added try/except wrapper around "Update archive status" section (line 749-767)
- Added [CALLBACK] log messages at start and end of callback
- Added exception handler to _schedule_async in printer_manager.py to log any exceptions from async callbacks
3. New Integration Tests (test_bambu_mqtt.py)
Added TestRealisticMessageFlow class with 5 new tests that simulate real MQTT message sequences:
1. test_timelapse_detected_at_print_start_in_same_message - The critical race condition test
2. test_timelapse_not_detected_when_disabled
3. test_timelapse_detected_when_enabled_after_print_start
4. test_print_complete_includes_timelapse_flag_full_flow - Full lifecycle test
5. test_print_failed_includes_timelapse_flag
These tests process messages through _process_message() with proper {"print": {...}} wrapping, matching real MQTT flow.
Files Modified:
- backend/app/services/bambu_mqtt.py - Timelapse race condition fix
- backend/app/main.py - Error handling + logging for on_print_complete
- backend/app/services/printer_manager.py - Exception capture in _schedule_async
- backend/tests/unit/services/test_bambu_mqtt.py - New integration tests
Next Steps
You should restart the application to apply these changes. The next print will show:
- [CALLBACK] on_print_complete started for printer X
- [ARCHIVE] Updating archive X status...
- [ENERGY], [PHOTO], [AUTO-OFF] logs (if those features trigger)
- [CALLBACK] on_print_complete finished for printer X, archive X
- Add dynamic humidity indicator with Bambu Lab style water drop icons
- Empty drop for good (dry), half-filled for fair, full for bad (wet)
- Configurable thresholds via Settings page
- Add dynamic temperature indicator with thermometer icons
- Empty for good, half-filled for fair, full for hot
- Colors match humidity: green/gold/red
- Add AMS Display Thresholds settings card
- Humidity thresholds (good/fair) configurable
- Temperature thresholds (good/fair) configurable
- Persisted in backend settings
- Fix AMS card stability issues
- Add ams_extruder_map to WebSocket broadcasts
- Cache AMS data and extruder map to prevent bouncing
- Fix L/R nozzle indicator for dual-nozzle H2 printers
- Fix status summary bar counting
- Don't count printers with unknown status as offline
- Theme-aware L/R nozzle badges (light/dark theme support)