mirror of
https://github.com/maziggy/bambuddy.git
synced 2026-09-30 03:01:21 +02:00
14da007c7dcc0ebbeb56b0baf2987c701ba0984c
2
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
6988a30eae |
Carry a fault's description in the status response (issue #2926)
The HMS catalogue has been in the backend all along and the status response never carried it, so every consumer that wanted to tell a user why a print halted resolved the same 853 codes from its own duplicate of the same sentences -- this repo's Python table, the frontend modal's, and at least one third-party client whose catalogue exists purely because the server would not say. Each ages separately, and a relay watching a printer could only manage "your printer needs attention" while the server already knew it was "Filament ran out. Please load new filament." hms_errors[] entries now carry a description, defaulting to null so a client that has never seen the field is unaffected. It is resolved where the fault is parsed rather than at the boundary that prompted the request, because there are three serializers of a fault, not one: the status response, the WebSocket broadcast, and the completion payload the queue's failure reason is built from. Adding it to only the first would have handed half the feature to a relay watching the stream, which is the likelier consumer of the three. The queue's failure reason now quotes the resolved sentence instead of looking the code up a fourth time, and the notification path reads it rather than re-deriving. That they cannot report different text for one fault is the point, and a test asserts they agree. describe_fault is the single mapping from either code shape onto the table. An 8-char print_error is the catalogue's MMMM_EEEE key with the separator removed -- the parser derives full_code and that key from the same 32-bit value -- so it resolves exactly. A 16-char hms[] identifier is tried whole and then collapsed to its first and last groups. That collapse is lossy, and keeping it was the decision worth making carefully. #2728 counts 65 documented faults falling onto 0300_0001 alone, so a hit can attribute a neighbour's sentence to this fault, and refusing it looks like the stricter reading. It is not: the notification path, the queue's failure-reason helper and the frontend modal have all resolved hms[] faults this way for as long as they have existed, and it resolves real ones -- a 0500_4038 nozzle mismatch arrives in that shape. Declining to collapse would have stopped describing faults that are described today, silently suppressed the notifications they raise, and left this field null while the UI showed text for the same fault. Narrowing it belongs with #2728, where both key spaces can move together. So the lookup is exactly what it was, verified rather than asserted: a test walks every catalogue code in both fault shapes across all three alert levels and checks the result against the derivation this replaces. A future change to the lookup cannot quietly stop notifications firing. The catalogue ships one language, so the field is English and unlocalized, which the schema and the API reference both say next to it. The camwall feed is deliberately left alone -- it is code-only because its token travels in a URL on a screen, and a readable sentence discloses more than the camera picture already does. The frontend keeps resolving its own text: switching it would change what filterKnownHMSErrors counts across eight call sites, which is #1840 and #2728's argument to have. HMSError.message goes with this -- a text field that was never set or read anywhere, and an invitation to populate the wrong one now that a live description sits beside it. ----- Record a failure code the user can actually look up The queue's failure reason formats a fault's module and error into MMMM_EEEE, and that one derivation never masked the error to 16 bits. A fault arriving from the printer's hms[] array carries its alert level in the code's high half, so the label came out as 0500_24038 -- five digits in a group that has four. It is not a code anyone can find on Bambu's HMS index, and because it matches no catalogue key the sentence explaining the failure was dropped along with it, leaving the bare number alone. The nozzle-size mismatch behind #1111 is exactly such a fault. Reported one way it read "[0500_4038] The nozzle diameter in sliced file is not consistent with the current nozzle setting"; reported the other, the same physical fault read "[0500_24038]" and nothing else. There is already a helper that gets this right, used by the archive's own failure-reason lookup, so this calls it instead of keeping a fourth copy of the derivation. It also takes the raw integer code the MQTT payload carries, which the local version only handled as a string. |
||
|
|
08601b4772 |
● fix(#1111): advance queue item when print fails before reaching RUNNING
When a file sliced for the wrong nozzle size is dispatched, the printer goes IDLE -> PREPARE -> FAILED without ever entering RUNNING. Completion detection required prev=RUNNING or _was_running=True, so on_print_complete never fired and the queue item stayed at "printing" forever -- blocking every subsequent pending item for that printer (check_queue seeds busy_printers from any row in 'printing'). Fire completion on FAILED from PREPARE or SLICING too. Restricted to those two pre-print states so a stale FAILED on first connection (prev=None) still can't accidentally advance an unrelated queue item. Also populate PrintQueueItem.error_message from the current HMS error list via the existing hms_errors.py lookup, so users see e.g. "[0500_4038] The nozzle diameter in sliced file is not consistent with the current nozzle setting" instead of a blank failure reason. |