Two printers went on printing while every archive they produced held nothing
but a filename. Bambuddy opened port 990, the printer accepted the connection
and answered with something that was not TLS, and connect() logged a warning
and returned False -- indistinguishable, to every caller, from "the file is
not at this path". So the 3MF lookup walked all six filename variants across
five directories with four retries each, the cover endpoint ran its own
sixteen-path sweep, and the timelapse scan added four more, all against a
sixteen-path sweep, and the timelapse scan added four more, all against a
printer that could not have answered any of them. One reporter's log carried
1813 identical handshake failures, another's 3511.
The evidence says this is the printer's own file service getting stuck, not a
model, firmware or TLS-configuration problem. In #2780's bundle the same two
printers ran clean from 22 July to 4 August and failed again from the 5th; a
second bundle shows an X2D serving files for five days, flipping on 19 July,
then failing every connection for eight days with zero successes. The same
models and firmware appear in roughly twenty other bundles with no occurrences
at all. Both bundles show it happening with cap_tls_v1_2 in effect -- the X2D
and H2C entries in ftp_profiles were added on analogy with P2S to fix exactly
this symptom, and the reporter's own debug line proves they do not.
An ssl.SSLError from connect() now opens a five-minute cool-off for that
printer. Subsequent connects return False without touching the network, so a
wedged printer is contacted twice an hour instead of hundreds of times a
minute, and the single warning that is logged names the remedy. The cool-off
is dropped on expiry rather than kept, so the map holds one key per currently
wedged printer. ftps_handshake_blocked() lets the sweeps stop: the 3MF lookup
abandons the remaining paths and skips the directory-walk fallback, the cover
endpoint returns 503 naming the file service instead of a 404 that reads as
"this print has no thumbnail", and the timelapse scan separates 503 (cannot
reach the printer) from 404 (no timelapse directory) -- one 500 used to cover
both, which is what the reporter hit when reproducing.
The Connection Diagnostic completed a bare TCP connect to 990, which is why it
reported the port green throughout: the port is open, it is what is behind it
that is broken. It now completes a real implicit-TLS handshake using the
model's own ftp_profiles cap, so a pass means the FTP client would also get
through. An open port that cannot negotiate reports warn with reason no_tls,
selecting a new message in all 13 locales that points at a printer restart
rather than at the firewall. No login is attempted, so this stays valid in the
pre-save Add Printer flow.
The cool-off tests run against a real socket that accepts on 990 and replies
with a plaintext FTP banner, reproducing WRONG_VERSION_NUMBER rather than
mocking ssl. The autouse fixture clearing _mode_cache now clears the cool-off
map too -- every test here talks to 127.0.0.1, so one left behind would make
the next test's connect() a no-op.
The follow-up to the same report: a second AMS 2 Pro, no aux power,
loaded entirely with PLA and drying at the 45C the reporter picked,
showed 45C and then switched to 55C.
Bambu never echoes back a cycle's filament or temperature, so both come
from the target cached when the command went out, and the fallback for
a missing cache reads the loaded trays. The first pass narrowed that
fallback to units whose spools agree on a filament, which fixed the
mixed-unit case in the original report but left the uniform case
answering with the spools' RFID-recommended drying_temp -- 55C here.
Agreement across slots is evidence of what is being dried, because the
dryer heats all of them. It is no evidence of the temperature, which is
picked freely in the popover, so the recommendation was never more than
a guess wearing the same confident "PLA @ 55C" as a known target.
uniform_tray_drying_hint therefore becomes uniform_tray_filament_hint
and returns the filament alone. The badge names a temperature only when
we sent it, and otherwise shows the filament and the countdown.
Both status builders also stopped filling the two fields independently.
Entering the fallback when either was missing let a cached filament pair
with a guessed temperature and render as though both were known; the
temperature now simply has no fallback to reach.
The badge required both fields before rendering anything, so dropping
the temperature would have blanked it rather than shortening it -- the
frontend now renders each on its own terms. No new translation key: the
filament type is a passthrough.
This changes what is shown when the cached target is missing, not why
it goes missing. If the reporter was on the fixed build, the falling-
edge gate is still letting a zero through on an unpowered unit, which
needs a log covering the start of the cycle.
The overlay at /overlay/{printer} draws live print data over a
full-screen camera view for OBS, a wall display or any browser source.
It has been tunable since it shipped -- which fields, what size, what
frame rate -- but only through query parameters documented in the wiki,
and temperatures were not among the fields on offer. The request asked
for temperatures first and for the field set to be selectable in the web
UI; this addresses both.
Nozzle, bed and chamber readings join the list. The target is drawn only
while the heater is still climbing, so a settled hotend reads "220°C"
for the rest of the print instead of the noisier "220 / 220°C" -- 219.6
against a target of 220 rounds to the same number, and repeating it says
nothing. Both nozzles appear on a dual-nozzle machine. They are drawn
whether or not a print is running, because a preheating printer is
exactly when they are worth watching, and each reading appears only when
the printer genuinely reports one: chamber temperature stays absent on
P1 and A1 models, which publish a chamber_temper with no sensor behind
it, so the overlay never puts a measurement on screen that does not
exist. Labels reuse the heater chart's strings rather than inventing a
second vocabulary for the same three things.
The feed sends an allow-list rather than the temperatures dict. That
dict doubles as the MQTT client's working memory -- derived heater flags
and private target-set timestamps live alongside the readings -- and an
overlay token is a narrower grant than a login, so it gets exactly what
the overlay draws and does not pick up fields as the dict grows. The
same chamber-sensor gate the full status payload already applies is
applied here. The integration test that asserts the payload's exact key
set, which exists to catch that surface widening silently, is updated
deliberately.
Temperatures are not in the default field set, so an overlay URL already
pasted into a scene renders identically after upgrading.
Settings -> API Keys -> Streaming Overlay now builds the URL: printer,
field checkboxes, size, frame rate, camera toggle, an optional token,
and a copy button. It persists nothing and calls nothing new -- the URL
is the configuration, which keeps a scene reproducible by copy-paste and
lets two displays show different fields off one token. Fields are
emitted in the overlay's own top-to-bottom order rather than click
order, and parameters left at their default are omitted, so the same
selection always produces the same URL. The preview alongside it stays
off until asked for: an always-live iframe would hold a subscriber on
the printer's single camera connection for as long as the settings tab
stayed open.
The preview needed one narrow security-header change. Every SPA route
sent frame-ancestors 'none', which is stricter than the SAMEORIGIN in
X-Frame-Options beside it and refuses even a same-origin frame, so the
preview showed Firefox's "another site has embedded it" page instead of
the overlay. The overlay path now sends 'self', mirroring /gcode-viewer,
which admits a framer only on this origin -- Bambuddy's own UI. Every
other path keeps 'none', and embedding the overlay from another host
still requires TRUSTED_FRAME_ORIGINS.
Starting the dryer on an AMS 2 Pro holding two PETG and two PLA spools
and picking PLA showed "PLA @ 45°C" for about a minute and then switched
to "PETG @ 65°C" for the remaining twelve hours.
Bambu never echoes back which filament or temperature a cycle is
running, so the badge reads the target cached when the command went out,
and that cache had been dropped. Between accepting the command and
settling its countdown the firmware publishes one update with the
remaining time at zero while the unit is still in its Checking phase --
the reporter's log has 720, then 0, then 719, and four seconds later the
same unit's info hex decodes to dry_status 2, Drying. The falling-edge
detector read that zero as the cycle ending. Losing the cached target
left the badge to guess from the first loaded slot, which was PETG, and
its RFID-recommended 65°C. The same false ending fired
on_drying_complete, so anyone with smart-plug auto-off-after-drying
switched on had power scheduled to cut one minute into a twelve-hour
dry; the reporter had it off, which is the only reason this reads as a
cosmetic bug.
A remaining time of zero now ends a cycle only when the unit is not also
reporting an active phase. dry_status comes from the same info hex
already parsed a few lines above, so this costs nothing to check.
Stopping and Error are deliberately not treated as active -- those
should end it -- and a unit that reports no phase at all still ends its
cycles, so the gate can only ever suppress on positive evidence that the
cycle is live. A suppressed edge leaves the remembered dry_time alone,
exactly as the #1462 absent-value skip does, so the push that really
ends the cycle still sees a non-zero previous.
The fallback guess is tightened to match. On a mixed unit the first tray
is evidence of nothing, and naming a temperature the cycle is not using
is worse than naming none, so it now answers only when every loaded
spool is the same filament and otherwise leaves the badge showing the
countdown alone. Both the websocket and REST status builders carried
their own copy of that loop; they now share one helper, which also takes
the temperature from the first slot that carries an RFID one rather than
giving up when slot 1 holds a third-party spool.
Every field that takes a chamber target stopped at 60: the per-filament
chamber map and per-print override in Preheat & Heat Soak, the chamber
quick-select presets, and the printer-card chamber control. 60 is the
X1E's ceiling and the X1E was the only heated-chamber model when that
limit was written; the H2 series and X2D heat to 65, so the top of their
range was unreachable.
The ceiling now lives in one constant per side (MAX_CHAMBER_TEMP_C in
backend/app/utils/printer_models.py and frontend/src/utils/printer.ts)
rather than as a literal at each call site. X1E firmware clamps a higher
request to its own maximum, so a shared ceiling is safe.
Also fixes a live bug at PrintersPage.tsx:7985: parsePresetTriple was
bounded to 60 there, and it rejects the whole triple on any out-of-range
entry, so a saved 65 preset would have silently reverted the printer
card to the defaults while Settings still showed 65.
device.airduct is pushed field by field - the modeCur handler reads it with
an "in" check for that reason - so a frame can carry parts without carrying
every fan. Absence in that list is what tells us a kit is not fitted, and
taken from a truncated frame it made both accessory badges vanish mid-print
and started rejecting fan=aux2 on a printer that has the fan.
A parts list now counts as a full inventory only when it carries ids 1 (part
cooling) and 2 (aux). Neither is optional on a machine that reports an
airduct at all, and both appear in every layout in the support-package
archive - P2S base 1,2 / P2S+kit 1,2,3 / X2D 1,2,3,10 / H2C,H2D,H2S 1,2,3,6.
Anything narrower is a diff frame: its speeds are applied, presence is left
alone. Presence can still be added from a partial frame; only retraction
needs the full list, so a kit that really is removed still disappears.
Also compose showChamberFan from both model lists rather than branching
between them, so the P2S/X2D entries in MODELS_WITH_CHAMBER_FAN stay
reachable instead of reading as dead, and note in the fan-speed docstring
that the aux2 gate also rejects between connect and the first airduct push.
mqtt_relay reads state.left_aux_fan_speed, but the SimpleNamespace fixture in
test_plate_clear_mqtt_notification enumerates its fields explicitly, so the two
status-payload tests raised AttributeError. I updated the equivalent fixture in
test_printer_manager_status_broadcast and missed this one — running only the
touched suites is what hid it.
Also addresses the round-2 review notes:
- exhaust_fan_present: documented that the H2 series reports part 3 too, so the
flag is not model-specific despite the name.
- Mask the part id after shifting, matching get_flag_bits(id, 4, 8), for
consistency with the state decode. No behaviour change for any observed id.
- Noted the unmapped H2 id 6 beside the id branches.
- Reject fan=aux2 when the printer reports no left_aux_fan_speed, so a POST
against an A1 no longer sends M106 P10 for absent hardware. The UI already
hid the badge; this closes the same hole on the API.
- Added a test asserting EXHAUST_FAN_LABEL_MODELS and the frontend's
MODELS_WITH_EXHAUST_LABEL cannot drift apart.
Review feedback on #2691: `state` is bit-packed like its sibling `range`
(end << 16 | start), and Bambu Studio decodes it with
get_flag_bits(state, 0, 8). Masking with & 0xFF before clamping means a
packed value decodes to the real percentage instead of clamping to 100.
Also moves the uses_exhaust_fan_label import to the top of printers.py with
the other imports.
Tests: packed value (60 << 16 | 45) decodes to 45, and plain 0-100 values
round-trip unchanged.
The fan-speed endpoint always reported 'Chamber fan set to N%', so on
P2S/X2D — where the printer card labels that fan 'Exhaust' — clicking
Exhaust produced a toast saying Chamber fan.
Adds uses_exhaust_fan_label() to printer_models so the badge label and the
API response share one source of truth, and uses it to pick 'Exhaust fan'
vs 'Chamber fan' in the response message.
Tests: helper coverage for P2S/X2D (incl. internal codes N7/N6), other
enclosed models, and unknown/missing model; API test asserting the message
matches the badge label per model.
The P2S/X2D have two fans bambuddy didn't fully handle. On the P2S both are
add-on kits; on the X2D they ship from the factory.
1. Left auxiliary part cooling fan — not shown or controllable. It is reported
ONLY as device.airduct part id 10 (raw id 160 >> 4; FAN_REMOTE_COOLING_1 in
Bambu Studio's DevFan::ParseV3_0) and is never mirrored into a flat
big_fanX_speed field, which is why it was invisible. This is the gap
identified in #2576, where the single 'Auxiliary' fan (big_fan1 / M106 P2)
only reaches the right-hand aux fan.
2. Chamber exhaust fan — shown on every P2S labelled 'Chamber Fan'. On P2S/X2D
Bambu's firmware/UI (and Bambu Studio's FAN_CHAMBER_0_IDX) call it 'Exhaust',
and it is a kit on the P2S rather than built in.
Both are now detected from device.airduct.parts, which lists only the fans that
physically exist, so each tile appears only when the hardware is present.
- bambu_mqtt: parse airduct part 10 -> left_aux_fan_speed (None when absent) and
part 3 presence -> exhaust_fan_present; set_fan_speed() accepts index 10 plus a
set_left_aux_fan() helper
- schema / status route / printer_manager broadcast / mqtt_relay expose both fields
- POST /printers/{id}/fan-speed accepts fan=aux2 -> M106 P10, the command Bambu's
official P2S machine profiles use
- frontend: 'Left Auxiliary Fan' tile shown when reported; big_fan2 tile labelled
'Exhaust' and presence-gated on P2S/X2D, unchanged 'Chamber Fan' elsewhere
- i18n: leftAuxiliary + exhaust for all 12 locales
Verified fan -> field map on a live P2S (fw 01.02.00.00), stable across cooling
and heating airduct modes:
Part cooling -> cooling_fan_speed / airduct id 1 (built in)
Aux -> big_fan1_speed / airduct id 2 (built in)
Exhaust -> big_fan2_speed / airduct id 3 (kit)
Left aux -> airduct id 10 only (kit; forced off in heating by mode config)
Tests: airduct id-10 parsing (raw 160 -> id 10, not literal 160), id-3 presence,
base-P2S absence, diff-push survival, clamping, malformed entries, M106 P10
emission, invalid-index rejection; fan-speed API aux2->10 mapping; frontend tile
presence and labelling per model/kit.
Pairs the top-down plate preview with the slicer's per-object pick mask
(Metadata/pick_N.png), whose pixel colours encode the same identify_id the
firmware's skip command takes, so a click resolves to a real object rather
than an inferred bounding box. Several objects can be selected before one
confirmation; selected and already-skipped items are highlighted on the
plate; the checklist stays available when no mask exists.
view=pick serves only the active plate's mask and 404s otherwise, unlike
every other view. A render returned in a mask's place would be decoded as
object IDs — dark pixels yield small integers that collide with real ones —
and a click would then skip an arbitrary object, mid-print, irreversibly.
The 404 is what tells the UI to fall back to the checklist.
Click mapping goes through the contained rect, since the canvas paints at
mask resolution under object-contain; clicks on a letterbox bar are rejected
rather than clamped onto whichever object touches the border. Confirming
names the object when one is selected and counts them when several are,
which is what plates of identically-named clones need.
No printer-control command path was added or changed; the layer, permission
and existing skip-command guards are untouched.
The A2L reports its 4-slot AMS Lite as unit id 16, but its slot-presence
bitmasks sit at bit base 24 (id 6) and it reports tray_now as a local 0-3
slot. Fed the raw id 16, the ams_id*4+slot convention probed bits 64-67
(always zero) and marked loaded slots empty; the local tray_now was read as
global, so usage deducted from the wrong spool (or not at all); and the
ams_id<=7 DB constraint rejected id-16 Spoolman links.
Normalise the Lite 16->6 at the MQTT ingest boundary so global tray ids land
at 24-27 - matching the firmware's own bit base, working with every existing
ams_id*4+slot consumer, colliding with nothing, and passing the DB
constraint. Globalise tray_now to 24+slot, widen the valid-tray guards, label
the unit "AMS Lite", and build the confirmed ams_mapping2 {ams_id:16,
slot_id:0-3} / flat 0-3 for dispatch. Outbound slot commands translate 6->16
on the wire via a single helper. Self-scoping: only unit id 16 is touched, so
all other printers/AMS types are unaffected. One uncaptured wire field (the
physical global tray on load/cali) is extrapolated and isolated to the helper.
Assigning a spool to an AMS tray pushed ams_filament_setting +
extrusion_cali_sel and reported success immediately, whether or not the
tray accepted it. A silently-dropped assignment never surfaced, and since
a print only deducts from the spool on the exact tray it pulls from, it
also recorded no filament usage - which made the whole thing feel random.
Read the AMS telemetry back after every assign (inventory assign_spool and
the Configure Slot modal) and toast the outcome: loaded when the tray
echoes the pushed tray_info_idx, a warning when the filament loaded but the
K-profile (cali_idx) did not, or not-confirmed after ~30s. Verification
uses the periodic per-tray push (the command ack hardcodes sequence_id 0
and can't be correlated); an on-demand pushall is nudged so it lands
quickly. Covers regular AMS, AMS-HT and external slots; stays silent rather
than inventing a failure if the printer goes quiet. The read-back check
runs on every AMS push because the change-hash excludes tray_info_idx.
The /overlay/{id} route renders without a login, but everything it draws is
auth-gated: printer status and name (PRINTERS_READ), one setting (SETTINGS_READ),
and the camera stream (a camera-stream token). A signed-in browser rides its JWT
from local storage; OBS is a fresh browser with no session, so the overlay stayed
blank whenever authentication was enabled. Cloudflare/remote access was never the
cause -- an incognito window fails identically.
Give the overlay a self-contained kiosk-token mode, mirroring the Cam Wall:
- New `overlay` long-lived-token scope, kept separate from `camwall`: the overlay
names the printed file on screen, which a Cam Wall token is trusted never to
expose, so folding it in would silently widen every existing wall token.
- New token-authed GET /printers/{id}/overlay-status returning exactly the fields
the overlay draws and nothing else; added to the auth-middleware allowlist so it
reaches its own RequireOverlayTokenIfAuthEnabled gate.
- StreamOverlayPage reads ?token= and, in that mode, authenticates its status and
camera calls with the token and skips the WebSocket (the 2s poll is the feed).
The logged-in path is unchanged.
- Token-mint UI (Settings > API Keys) offers the scope with a ready-made
/overlay/{id}?token= URL copied once on creation.
The Configure AMS Slot modal sends built-in / local / Orca-generic presets
with a GF* tray_info_idx but an empty setting_id, and configure_ams_slot
forwarded that empty value to ams_filament_setting. The firmware treats a
filament-id-without-setting-id slot as half configured: it shows the new
material briefly, then reverts to its previously stored profile.
Back-fill setting_id from the resolved tray_info_idx via
filament_id_to_setting_id when the client sent none (e.g. GFB99 -> GFSB99),
mirroring the derivation the inventory/assignment path already does. Doing
it server-side also protects API callers and future frontends. P* user
presets and already-GFS* values are left unchanged, and an explicit
setting_id still passes through untouched.
Three more idle-in-transaction / thundering-herd paths from farm testing:
- print_scheduler: _start_print commits before the FTP delete/upload and
_preheat_and_soak commits before the heat-soak wait, so the per-item
session no longer sits idle-in-transaction across preheat + upload.
- cloud/filament-info: rollback the request transaction after the token
read and before the sequential Bambu Cloud calls; single-flight
concurrent misses for the same setting_id through one shared call.
- printers/cover: coalesce identical in-flight cover requests so followers
serve from the cache the leader fills instead of duplicating the
multi-path FTP + 3MF extraction.
Also adds pool_use_lifo (PostgreSQL default on, DB_POOL_USE_LIFO override,
shown in /system/db-pool) so a bursty farm keeps a small hot connection set.
The firmware's runout HMS text says "insert into the same AMS slot", which is
wrong under AMS Filament Backup: the firmware won't re-accept the depleted slot
and advances to the next compatible one. Bambuddy parsed print.ams.tray_now only
and dropped tray_tar/tray_pre, so the expected slot never reached the UI.
Capture tray_tar/tray_pre on PrinterState and, while paused, resolve them to
global tray IDs (expected_tray/previous_tray) on both the REST and WebSocket
status payloads via a shared resolver: single-AMS passthrough, multi-AMS
snow-mapping resolution, AMS-HT/external passthrough, and an honest null when the
slot can't be placed. The AMS graphic highlights the expected slot (amber) and
the ran-out slot (red); the HMS modal re-describes runout codes to name both,
falling back to "check the printer" when unresolved. Runout copy translated in
all 11 locales.
Reporter @Jostxxl confirmed tray_pre=1/tray_tar=2 during the pause (ran out in
Slot 2, printer expected Slot 3).
The remaining routes of the idle-in-transaction class: the file-manager,
storage, camera-snapshot and timelapse routes each took their printer row
via Depends(get_db) and then talked FTP/camera on the same held session, so
a farm dashboard polling cover/snapshot tiles (offline printers included)
crept the pool to exhaustion over ~23h. They now read in a short session and
release before the I/O; timelapse re-opens a fresh session only for the write.
Also caps the four bare-executor FTP helpers with asyncio.wait_for so a
saturated 48-worker pool can't pin a caller (and its DB connection)
indefinitely, and runs the synchronous smtplib send off the event loop with
an explicit timeout so a wedged relay can't freeze the loop.
GET /printers/{id}/cover took its printer row via Depends(get_db), whose
yield-dependency session stays open for the whole request — including the
3MF cover download (up to 8 remote paths x retries with backoff, minutes
under FTP contention). One pooled connection sat idle-in-transaction the
entire time; on a large farm a wall of dashboards drained the pool. The
route now fetches the printer in a short-lived async_session() and releases
the connection before the download (expire_on_commit=False keeps printer.*
readable). Pinned by a signature-inspection guard that fails if get_db is
ever re-added.
fix(print-start): release the DB connection across plate detection and 3MF download (#2572)
on_print_start held one session from top to bottom of the handler, across
two slow I/O blocks that need no database: the plate-detection camera grab
and, on the new-archive path, the multi-path 3MF FTP download (its own
comments cite worst cases of tens of minutes). The connection sat idle-in-
transaction for both, once per starting print. It now commits at each
boundary — only read SELECTs have run on those paths (every write branch
returns earlier), so the commit persists nothing and simply returns the
connection to the pool for the I/O; the next query re-acquires, and
expire_on_commit=False keeps printer.* readable.
fix(startup): connect to printers concurrently so the API serves within seconds (#2572)
init_printer_connections awaited each printer's connection serially, and
connect_printer ends in a fixed 1s settle wait. The MQTT connect is non-
blocking (connect_async + loop_start), so that 1s x fleet size was pure
serial dead air the FastAPI lifespan blocked on before uvicorn began
serving — ~100s before port 8000 responded on a 93-printer farm. The
connections are now started with asyncio.gather, so the step takes ~1s
regardless of fleet size. return_exceptions=True isolates each result: one
unreachable printer no longer aborts the rest, or startup itself.
Manual jog could drive an axis past its travel limit into a collision.
Instrumenting the exact G-code to an H2D showed Bambuddy sending a clean
move at the limit (G91 / G1 Z-1.00 F600 / G90, no M211) that the printer
ran straight past, while its own touchscreen refuses the identical move.
This is a Bambu firmware bug: soft endstops are not enforced on G-code
received over MQTT, and no axis position is reported, so the move cannot
be clamped firmware- or client-side from position.
Two changes: (1) jogs no longer wrap moves in M211 S0/S1 — that disabled
the firmware's soft endstops globally, breaking even the touchscreen's
limits until a power cycle; a bare move keeps the touchscreen protected.
(2) The jog panel shows a prominent warning that travel limits are not
enforced during manual moves due to the firmware bug. Client-side
dead-reckoning enforcement is tracked separately.
The reporter found what his P1S was doing, and it is in Bambu's P1 manual:
"P1S connected AMS drying functions may only be controlled from the P1S screen."
The firmware acks ams_filament_drying with result: success and then discards it,
which is why three commands on an idle printer left the AMS 2 Pro at dry_status 0.
No command can start a cycle on a P1, on any firmware, so don't offer one.
supports_drying() now excludes the P1 series outright, replacing the 01.08+ gate
carried since #292 — that version is when P1 firmware gained AMS 2 Pro support,
not remote drying, and it was never checked against a live P1. Both drying routes
refuse with a specific 400 instead of publishing a message the printer will drop;
queue and ambient auto-drying skip P1s via the same helper.
A new drying_screen_only flag keeps the control on the card, disabled, saying why
— a P1 owner needs to learn where to dry, not watch the button disappear. A cycle
started at the printer still shows with its countdown; only Stop goes away, since
a P1 ignores stop exactly as it ignores start.
Also corrects the wiki firmware matrix, which listed P1P/P1S as supported and
(separately) P2S/H2S/H2C as unsupported. 8 tests.
extract_printable_objects_from_3mf() has accepted a plate_number since it was
written and no caller ever passed one, so it took root.find(".//plate") — the
first plate in the file. Passing one would not have helped either: the lookup
was .//plate[@plate_idx='N'], a predicate on an attribute neither Bambu Studio
nor OrcaSlicer writes. The index lives in a <metadata key="index"> child, as
threemf_tools and filament_requirements already read it, so the selector never
matched and fell back to plate 1 regardless.
On an all-plates .gcode.3mf that meant Skip Objects offered the wrong plate's
objects, with that plate's marker positions drawn over the correct plate's
thumbnail (/cover resolves the plate properly via resolve_plate_id, the object
list did not). The reporter printed a one-object plate and was shown the four
copies from another plate of the same file.
Select the plate on its index metadata, and pass resolve_plate_id(state) at all
three call sites so the list and the thumbnail share one resolver. Also stop
peek_plate_index_in_3mf() reporting plate 1 for a multi-plate file: it backs the
running one, so an all-plates upload printing plate 2+ lost its archive entirely.
A spool with no readable RFID was reported by the standard AMS with an empty
tray_type and state=9 — structurally identical to a truly-empty slot at the
tray level — so the AMS card rendered it "Empty" while Bambu Studio correctly
showed "?". The authoritative "a spool is physically here" signal is firmware's
AMS-level tray_exist_bits bitmask (what Studio uses), but Bambuddy inferred
emptiness from the per-tray state/tray_type. Confirmed from the reporter's
bundle: tray_exist_bits=f (all four slots present) with tray_is_bbl_bits=5
(only slots 0,2 Bambu) — the present-but-non-Bambu slots were the ones shown
Empty. Supersedes closed#1838.
apply_tray_exist_bits() already parses the bitmask to clear stale fields on
absent slots; it now also annotates each slot with an authoritative `exists`
bool, gated behind a new annotate_exists flag so only the printer-card path
sets it. The VP bridge leaves it off, so the `exists` key never reaches the
slicer wire format. `exists` flows through the AMSTray schema/serialization to
the frontend, where getEmptySlotKind() uses it: exists===true + no tray_type
-> "?" (present, unconfigured), exists===false -> "Empty", exists absent ->
the previous state=9/10 heuristic (AMS-HT and missing-bitmask paths unchanged).
H2D/X1C already reported present-unknown slots with a non-9 state and took the
"?" path; with the fix they reach it via `exists` and are unaffected.
The HMS error modal had three compounding bugs that surfaced when a
user forced a wrong-plate HMS (0500_8051) and tried to dispatch the
per-fault actions.
(1) IGNORE_RESUME did not ignore. Bambuddy redirected the action on
state=PAUSE to a plain `resume` command, citing a #1830 verdict that
BambuStudio's "err-bearing shape" was firmware-silently-rejected.
BambuStudio source disagrees: DeviceErrorDialog.cpp:600 dispatches
IGNORE_RESUME via command_hms_ignore, whose wire shape is
{command:"ignore", err:"<decimal>", param:"reserve", job_id:...}.
That's a distinct command from `resume` — the firmware suppresses
the next re-check AND auto-resumes in one operation. Plain resume
means "re-check normally", which is exactly why the wrong-plate
detection re-fired 1-2 s after the user clicked Ignore. The #1830
"err-bearing shape rejected" test almost certainly sent the err as
a hex shortcode; BambuStudio passes std::to_string(int m_error_code)
i.e. the DECIMAL form, which is what the firmware matches against.
(2) Action buttons read as inert badges. The button className used
`hover:${buttonHoverColor}` — a template-literal interpolation
Tailwind's JIT scanner can't see as a literal string, so the
per-severity hover utility never reached the compiled CSS. Same
bg/text color as the severity badge above and no border made it
read as another label. No disabled state and no spinner during the
2.5 s ack wait left clicks sitting silently inert.
(3) Ack-detection 502'd on legitimate ack. The route compared
(gcode_state, hms_errors-len) before vs after publish; wrong-plate
re-pause round-tripped both fields to their pre-publish values
inside the 2.5 s window → false 502 even though the firmware fully
ack'd. PROBLEM_SOLVED_RESUME working but IGNORE_RESUME 502'ing on
the same fault was the same race resolving differently.
Fixes:
bambu_mqtt.py — new hms_ignore_command() publishes the BambuStudio
shape; existing hms_ignore(persistent) renamed to hms_idle_ignore
(unchanged shape, used by NO_REMINDER_NEXT_TIME per
DeviceErrorDialog.cpp:588). Dispatch routes IGNORE_RESUME,
IGNORE_NO_REMINDER_NEXT_TIME, and DONT_REMIND_NEXT_TIME to
hms_ignore_command (BambuStudio routes all three to the same
command_hms_ignore — the "don't remind" half is the firmware's
job). NO_REMINDER_NEXT_TIME stays on hms_idle_ignore type=0. Hex →
decimal err conversion at the helper layer with a defensive
fallback. job_id=None → empty string (matches BambuStudio's
std::string default).
HMSErrorModal.tsx — getSeverityInfo loses the dead buttonHoverColor
field. Action button uses static
`bg-white/10 hover:bg-white/20 active:bg-white/30 text-white
border border-white/20`, wires
`disabled={!hasPermission||mutation.isPending}`, and renders
`<Loader2/>` only on the button whose (action,print_error) matches
mutation.variables.
printers.py — ack-detection probes `client._last_message_time`
(bumped on every MQTT push regardless of payload) rather than
diffing state fields. The pushall that follows every command
guarantees a fresh push lands inside the 2.5 s window on any
healthy printer; only firmware-silent-drop leaves the timestamp
untouched, which is the 502 path #1830 wanted.
Three distinct bugs combined into one user-facing failure: clicking
Stop / Problem-solved-and-resume / Ignore-and-resume returned 200 OK
but the printer didn't act, modal stayed up, print stayed paused.
Verified by injecting candidate command shapes on device/<sn>/request
against a live H2D paused on a wrong-plate HMS (print_error=0x05008051).
(1) hms_resume / hms_stop dispatched the "err"-bearing shape that
BambuStudio doesn't actually send; Bambu firmware silently rejects it.
Both now send the plain shape ({"print":{"command":"<x>","param":"",
"sequence_id":"0"}}). PAUSE -> FAILED in 1.7s for stop, PAUSE -> RUNNING
in <2s for resume.
(2) IGNORE_RESUME mapped to idle_ignore, which is BambuStudio's
"dismiss a warning" command and only works for non-pause warnings.
hms_ignore now branches on state.state == "PAUSE": paused -> plain
resume; not-paused -> idle_ignore with the full-length err.
(3) 64-bit hms[]-array faults were truncated to a non-matching err.
short_code in _parse_status discarded 32 of the 64 identifier bits, so
the firmware didn't match it to the active fault. HMSError.full_code
now carries the canonical hex identifier (16 chars for hms[] faults,
8 chars for print_error faults). Catalog lookup tries 16-char first,
falls back to 8-char. HmsActionBody.print_error pattern relaxed to
^[0-9A-Fa-f]{8}([0-9A-Fa-f]{8})?$.
(4) execute_hms_action returned publish-success as success, masking
every silent-rejection bug above as 200 OK. Route now snapshots
(state.state, len(state.hms_errors)) before dispatch, awaits
HMS_ACTION_ACK_WAIT_SECONDS (default 2.5s, module-level so tests
override), and returns 502 with "Printer did not acknowledge HMS
action within 2.5s" if state didn't move.
Bambu's per-tick AMS push carries only the dry_time countdown — the
filament name and target temperature the user chose are never echoed on
the wire. The AMS card had no source of truth for them and rendered the
bare "Drying · 11h 35m left". The badge now shows
"Drying · PETG @ 65°C · 11h 35m left", matching the cycle the user
actually started.
BambuMQTTClient caches {ams_id: {filament, temp}} on send_drying_command
(mode=1), clears on mode=0 and on the dry_time falling edge to 0 — the
same per-AMS edge detector that drives the smart-plug-after-drying
callback. PrinterManager.get_drying_targets exposes it, the four
printer_state_to_dict call sites thread it through, AMS schema gains
dry_target_temp + dry_filament, and routes/printers.py builds the same
fields into the manually-constructed AMSUnit response.
When no cached target exists (drying started in a previous backend
lifetime, or initiated outside Bambuddy), the badge falls back to the
first loaded tray's tray_type + RFID-recommended drying_temp — the
heuristic the popover already uses to seed defaults.
i18n: printers.drying.targetSummary = "{{filament}} @ {{temp}}°C" in
all 11 locales. Parity check 5356 leaves per locale.
Note: a user reported the H2D's own physical display still labels the
cycle by the loaded tray's filament (e.g. "PLA" instead of the
Bambuddy-requested "PETG"). The wire payload is correct end-to-end —
journalctl shows filament: "PETG" sent and result: success ACKed — and
the badge in Bambuddy's own UI now reflects what we actually sent,
independent of the firmware's display choice.
Continue Auto-Drying while a print is running on capable hardware.
New Settings > Print Queue > "Continue drying while printing" toggle
(default OFF). Extends _check_auto_drying in print_scheduler.py to
evaluate running printers when supports_drying_while_printing(model,
firmware) returns true. Strict allowlist verified per Bambu wiki
release notes for "Print While Drying" / "printing while filament is
drying": H2D 01.03.00.00+, H2C/H2S/P2S/H2D Pro 01.02.00.00+, X2D/A2L
01.01.00.00+, X1C 01.11.02.00+. P1*, A1, A1 Mini, X1 (non-C), X1E
intentionally excluded. Mid-print drying temperature is capped at
max(40, preset_temp - 5) to protect spools from heat damage inside the
hot enclosure during a print, matching Bambu's own "lower drying
temperature during printing" guidance.
Rotate-spool toggle in the drying popover is now disabled when any tray
in the targeted AMS has filament threaded into the feed tube
(tray.state === 11). The whole AMS rotates as one mechanism, so a
single loaded slot locks the entire unit. Previously the toggle was
always clickable and the firmware rejected with dry_sf_reason=[3]
(ConsumableAtAmsOutlet) after the click. The first cut keyed on the
printer-level tray_now but missed the H2D's typical post-print state
where tray_now resets to 255 while filament stays in the tube — the
per-tray state field reports it correctly. Submission also clamps
rotateTray off so a stale-true state from a previous AMS can't leak
through.
Backend: supports_drying_while_printing in printer_manager.py covers
display names and internal SSDP/MQTT codes (O1D, O1E/O2D, O1C/O1C2,
O1S, N6, BL-P001, N7, N9). New print_drying_enabled boolean in
settings schema. Frontend: toggle on SettingsPage, gate + clamp on
PrintersPage drying popover using existing amsData cache. i18n: 3 new
keys x 11 locales, no English fallback. Tests: 7 cases on the gate
matrix (TestSupportsDryingWhilePrinting), 4 cases on the scheduler
mid-print path (TestMidPrintDrying), 9 cases on the rotate gate state
transitions. Full backend pytest -n 30 green (4251/4251), ruff clean,
frontend npm run build clean, i18n parity 5355 leaves per locale.
Two tightly-coupled deliverables in one drop -- a new AMS Filament Backup
status/control surface, and the #1766 fix that depends on it.
Added -- AMS Filament Backup status + control
- Parse bit 18 of top-level print.cfg into PrinterState.ams_filament_backup
on every push_status. Verified against OrcaSlicer source
(DeviceManager.cpp:4961) and a live H2D ON/OFF capture. Tri-state
(None = A1 family / pre-cfg push) preserves today's behaviour.
- Hold-timer guard (3 s) prevents stale frames from flickering the badge
back to the printer's old cfg after a user-initiated toggle.
- POST /printers/{id}/ams-backup toggle, set_ams_filament_backup() client
method calling _set_print_option("auto_switch_filament", enabled).
- GET /printers/{id}/inventory-remain endpoint exposes the same map the
dispatcher uses (internal and Spoolman modes both work uniformly).
- Small icon badge in the printer card's "Filaments" section header
(placement reads as printer-wide because the cfg bit is printer-wide,
not per-AMS). Click to toggle, success toast.
- 5 i18n keys x 11 locales for the badge UI.
Fixed -- #1766: prefer_lowest didn't pick lowest, ignored backup state
- Backend gate in _compute_ams_mapping_for_printer: coerce prefer_lowest
to False when status.ams_filament_backup is False; log the skip.
- New effectivePreferLowest(setting, backup) helper applied at every
frontend sort entry point: single-printer PrintModal, multi-printer
hook per-printer, PrinterSelector InlineMappingEditor, FilamentMapping
standalone editor (the last had NO preferLowest awareness at all
before this change).
- New preferLowestSortKey(f, inventoryByTrayId) mirrors backend's two-tier
key exactly, including the banding tie-break (regular AMS < AMS-HT <
external) so the client-side pre-compute matches the dispatch-time pick.
An earlier draft used a flat `amsId * 4 + trayId` priority which gave
external slots (ams_id = -1) a NEGATIVE priority -- caught in code
review before commit.
- Settings -> Filament -> "Prefer lowest remaining filament" gets an
explanatory note about the printer-side AMS Backup dependency, with
i18n key in all 11 locales.
GET /api/v1/printers/ and /api/v1/printers/{id} return access_code
only when the caller holds PRINTERS_UPDATE. Adds PrinterResponseWithSecret
as the elevated response shape; PrinterResponse no longer carries the
field. Auth-disabled single-trust mode preserved.
Two warnings polluting every A1 support bundle on healthy prints, both
unrelated to the timelapse-default behaviour the issue actually reports.
1. mqtt_bridge.py's post-bind nudge calls request_status_update on the
real printer's MQTT client to populate the bridge cache without
waiting for the next periodic pushall. The bind frequently races the
TLS handshake, especially on A1 firmware. Skip the nudge when
state.connected is False — the periodic pushall fills the cache
anyway. The WARNING in bambu_mqtt.py stays for the genuinely-
actionable callers (refresh-status API, bug reporter).
2. Post-finish SD-card cleanup (and the symmetric forced-timelapse dir
walk) used delete_file_async's bool return to drive a WARNING when
all candidates failed. A1 firmware self-cleans the SD card before
our cleanup runs — every candidate FTP-DELE returns 550, we burn
the retry budget, then WARN on a successful print. Introduce
DeleteResult.{DELETED,NOT_FOUND,FAILED} so the helpers only WARN
on real network/auth/transient failures. NOT_FOUND advances to the
next candidate without consuming the 2s backoff. User-facing delete
endpoint returns 404 on NOT_FOUND.
asyncio holds only a weak reference to tasks returned by
``create_task``. Fire-and-forget callers that discard the return value
let the event loop GC the task before it finishes, logging
``Task was destroyed but it is pending!`` with no traceback. The #1648
support-bundle review surfaced 94 such warnings in 8 days of v0.2.4.5
-- the silently-vanished exceptions reach support bundles as opaque
GC notices instead of actionable errors.
New backend/app/core/tasks.py::spawn_background_task(coro, *, name=None)
is the one place in the codebase that calls asyncio.create_task. It
stores the task in a module-level set, attaches a done-callback that
auto-removes on completion AND surfaces any uncaught exception via the
logger with the originating traceback, and accepts name= so a leak
source is traceable through /tracebacks and the log line. Cancelled
tasks don't log (a shutting-down service is not an error).
Migrated the 16 truly-orphan create_task call sites to the helper:
main.py (8):
reconcile-stale, cooldown-poweroff, energy calc, smart-plug,
maintenance-check, photo-then-notify, layer-timelapse,
scan-timelapse, print-scheduler, notify-no-archive (the last one
was hand-rolling the same pattern with task + no-op done_callback)
printers.py:3123 apply-pa-after-refresh
print_queue.py:1034 queue cooldown-poweroff
firmware_update.py:261 firmware upload
archive.py:1514 timelapse mp4 convert
print_scheduler.py:2199 watchdog print-start
library.py:1614 STL backfill
smart_plugs.py:259 tasmota scan
discovery.py:159 subnet scan
smart_plug_manager.py x3 plug auto-off-pending
background_dispatch.py x2 (lambda-wrapped inside
loop.call_soon_threadsafe) upload progress
Sites that already kept strong refs are unchanged:
self._tasks.append(asyncio.create_task(...)) -- VP manager,
tcp_proxy, mqtt_server
self._x_task = asyncio.create_task(...) on service instances --
mqtt_bridge, obico_detection, github_backup, archive_purge,
local_backup, library_trash, discovery service
Locally assigned + awaited/gathered -- tcp_proxy bidirectional
pumps, camera_fanout, slice_dispatch, slicer_api progress_task,
manager._finish_release_task, main.py module-level cleanup loops
The existing connection diagnostic proved TCP + TLS + auth + SUBSCRIBE but
not that the printer was actually publishing reports. A wrong-cased serial
passes mqtt_auth because the broker accepts the subscription regardless;
the user-visible symptom is empty AMS / no K-profiles / no custom filaments
in the slicer Device tab because the VP cached state is empty. Bambuddy
already logged the actionable hint at bambu_mqtt.py:498 but only to
container logs.
New printer_publishing check turns that warning into a structured
diagnostic result. Pass = bridge has seen at least one report since the
last (re)connect; fail = zero reports across the wait window with fix-text
pointing at the case-sensitive serial. Bounded 10s poll on the on-demand
UI route, no wait on the support-package gathering path so bundling stays
fast. Exits the moment a message arrives — typical wall-clock is 1-2s.
Frontend renders an elapsed-seconds counter plus a "Listening for status
report — up to 10s" hint during the pending state so the wait doesn't look
hung. PUBLISH_WAIT_DEFAULT_SECONDS pinned on both sides.
report_messages_since_connect exposed as a public property on
BambuMQTTClient so the diagnostic doesn't reach into private state.
Reporter wanted to select a transparent filament colour in the spool
editor; CMW-ISS confirmed on v0.2.5b1 that AMS-detected transparent
spools were silently labelled "Black" in the filament-mapping dropdown
because the colour name resolver dropped the alpha byte and the underlying
RGB 000000 HSL-bucketed to "Black". Spoolman already supported 8-digit
hex; the built-in inventory didn't.
Eight collapsing sites fixed together so transparent reaches the user
intact:
- frontend/src/utils/colors.ts: hexToColorName / getColorName /
resolveSpoolColorName / isLightColor short-circuit to "Clear" for
alpha=00 before HSL bucketing or catalog lookup
- frontend/src/utils/amsHelpers.ts::normalizeColor preserves the alpha
byte when alpha < FF (normalizeColorForCompare unchanged so type/colour
matching is unaffected)
- frontend/src/components/spool-form/constants.ts: new
{ name: 'Clear', hex: '00000000' } preset in QUICK_COLORS
- frontend/src/components/spool-form/ColorSection.tsx: hex draft accepts
0-8 chars, commits at 6 (+FF) or 8 verbatim; blur pads 7-char to 8;
selectColor passes 6-char as +FF / 8-char verbatim; isSelected matches
on full rgba; swatch buttons paint a checkerboard for alpha=00
- backend/app/api/routes/printers.py::get_available_filaments preserves
the full rgba on both AMS and vt_tray branches (6-char dedup key
unchanged)
- backend/app/services/spoolman.py::parse_ams_tray drops the silent
00000000 -> F5E6D3FF cream rewrite — the swatch renderer paints a
checkerboard underlay for alpha < FF already (added in #1154), so the
rewrite was hidden technical debt that made every AMS-detected
transparent spool land in inventory as cream
- backend/app/services/spool_tag_matcher.py::create_spool_from_tray
short-circuits the colour-catalog lookup for alpha=00 and stores
color_name="Clear" directly — otherwise an RFID-tagged transparent
Bambu spool would resolve against the #000000 catalog row (or "Black"
via the HSL fallback) before the frontend's resolver ever saw it
- Two shared helpers in utils/colors.ts — getSwatchStyle(rgba) (style
object: checkerboard for alpha=00) and spoolColorString(rgba)
(8-char hex string for SVG fill) — applied to every simple-swatch
site that would otherwise have rendered Clear spools as solid black:
LabelTemplatePickerModal, SpoolBuddyInventoryPage (SpoolCircle + dot),
SpoolBuddyAmsPage (both branches), SpoolBuddyWriteTagPage (4 sites),
ForecastPanel, AssignToAmsModal, AssignSpoolModal (both branches),
InventorySpoolInfoCard, TagDetectedModal, SpoolInfoCard, LinkSpoolModal,
and the FilamentSwatch tooltip title fallback
Intentionally NOT changed: native <input type="color"> keeps 6-char hex
(can't pick alpha; onChange still emits +FF, correct); Spoolman's
_find_or_create_filament strips alpha (Spoolman catalog is 6-char only);
print_scheduler colour matching strips alpha (auto-mapping treats Clear
as Black for slot compatibility); label_renderer prints "#RRGGBB" on the
physical label (printers can't print transparency, swatch fill via
_color_from_hex still honours alpha).
A triage review of the last 200 closed issues found ~1/3 were
user-side setup errors — printer not in LAN developer mode, blocked
ports, Docker bridge networking, wrong access code, cross-subnet —
each costing a multi-round-trip support exchange.
Add a Connection Diagnostic that runs those checks automatically:
- backend/app/services/printer_diagnostic.py: TCP probes of MQTT
8883 / FTPS 990 / RTSPS 322, LAN developer mode, Docker network
mode, printer/host subnet match, MQTT credential class; each
check returns pass/fail/warn/skip with a localized fix.
- Routes: GET /printers/{id}/diagnostic (saved printer) and
POST /printers/diagnostic (pre-save Add-Printer flow).
- ConnectionDiagnostic.tsx: modal + shared checklist, surfaced from
the printer card actions menu, an offline-printer quick button,
the Add-Printer dialog, and a new System-page section.
- The in-app bug reporter scans configured printers when the form
opens and always shows the result inline — a healthy confirmation,
or the detected problem and its fix.
- config.yml troubleshooting link repointed to the rendered wiki
page; bug_report.yml gains a diagnostic checkbox.
Diagnostic strings translated across all 8 locales. Backend service
unit tests (15) + frontend modal tests (3). Ruff clean, frontend
build clean, i18n parity green.
Cover endpoint had no negative cache: when every FTP path returned
550 for a print whose 3MF wasn't on the printer (typical SD-card
print), each frontend refresh re-ran the full 8-path fan-out. Add
_cover_404_cache keyed by (subtask_name, view_key) and short-circuit
to 404 on hit; clear alongside _cover_cache on print start. Only
populated on genuine 404 paths, not transient FTP errors, so flaky
network doesn't lock out future retries.
GitHub update-check had no backoff on 403 rate-limit. Add module-
level _github_rate_limit_until plus three helpers; check before
every api.github.com call in /updates/check and
_discover_target_release. Read X-RateLimit-Reset from the 403 with a
1-hour fallback when the header is absent and a 60-second floor to
guard against container/GitHub clock skew. Route surfaces
retry_after_seconds so the UI can display real wait time.
The "ffmpeg didn't terminate gracefully" line the reporter quoted
is the standard SIGTERM/SIGKILL pattern in camera.py and unrelated
to the FTP loop; it goes away on its own once the cover endpoint
stops hammering the printer.
Several support reports traced back to one root cause: a mistyped access
code in Add Printer left an empty card on the dashboard. POST /printers/
was persisting the row first, then firing connect_printer() fire-and-forget.
Now we test_connection() BEFORE the insert; failure returns HTTP 400 and
the row is never written.
Structured error response -- detail={"code", "message"} -- so the toast
shows the localized message instead of the English fallback. New
ApiError.code field on the frontend; printers.toast.connectionFailedNotAdded
On A1 / A1 Mini, clicking the "Up" arrow on the printer-card bed-jog
control sent the nozzle straight into the build plate. Reporter
triggered it with the 50 mm step and crashed their nozzle.
Root cause: the bed-jog UI was designed against the X1 / P1 / H2 family
where the bed is the Z-axis and Bambu's firmware homes Z=0 at the top,
so G1 Z- raises the bed toward the toolhead (decreases the nozzle-bed
gap). The frontend maps "Up" to negative distance with that convention
in mind.
A1 / A1 Mini are bed-slingers: bed moves on Y, toolhead moves on X+Z,
firmware uses standard cartesian Z (Z+ = toolhead up). On those models
G1 Z-10 drives the toolhead DOWN 10 mm. There was no model
classification at the bed-jog code path, so every printer got the same
X1-convention G-code.
Fix: new is_bed_slinger(model) helper in printer_manager (sibling to
existing supports_chamber_temp / has_stg_cur_idle_bug, reuses the
already-defined A1_MODELS frozenset which covers display names and
internal codes N1 / N2S). The bed-jog route now inverts the signed
distance before emitting G-code when the printer model is in that set,
so UI "Up" semantics ("decrease nozzle-bed gap") stay consistent
regardless of which physical part moves. Frontend untouched, single
source of truth lives in the backend, keyed off the Printer.model
column. Route Query description and docstring updated to spell out the
new contract: distance is the gap adjustment, not the raw Z value.
Reported by @1000Delta. The printer file download (and three sibling
endpoints) raised UnicodeEncodeError: 'latin-1' codec can't encode
characters... on any filename outside U+0000..U+00FF (Chinese,
Japanese, Arabic, accented Latin), because the route pushed `filename`
straight into Content-Disposition: attachment; filename="...".
Starlette/uvicorn encodes response headers as latin-1, so the assignment
crashed at write-time.
New backend/app/utils/http.py::build_content_disposition emits both an
ASCII-stripped legacy filename="..." fallback and an RFC 5987
filename*=UTF-8''<percent-encoded> parameter. Every modern browser
prefers the *= form, so the original Unicode filename round-trips
through Save-As intact.
Same shape was latent in three siblings and fixed in the same PR
(no deferred follow-ups): archive QR endpoint (archive.print_name
from 3MF metadata), project ZIP export (project.name — the existing
isalnum() sanitiser passes non-ASCII through), and the PDF label
streamer (latent today, callers ASCII-only but the helper hardens it).
feat(spoolman-inventory): squashed feature work for rebase onto dev
Squashed all commits from feature/spoolman-inventory-ui onto a single commit
to enable a clean rebase onto dev. Original per-commit history preserved at
backup tag backup/spoolman-inventory-ui-prerebase-20260507-105721.
feat(spoolman-inventory): squashed feature work for rebase onto dev
Squashed all commits from feature/spoolman-inventory-ui onto a single commit
to enable a clean rebase onto dev. Original per-commit history preserved at
backup tag backup/spoolman-inventory-ui-prerebase-20260507-105721.
The ams_load_filament / ams_unload_filament MQTT primitives existed
in bambu_mqtt.py but were unused — no HTTP route and no UI. Surface
both as POST /printers/{id}/ams/load?tray_id={int} and
POST /printers/{id}/ams/unload, gated on PRINTERS_CONTROL.
Wire them into the existing AMS slot popover (next to "Re-read RFID")
and add a popover wrapper on the external spool slot which had none.
Hidden while the printer is RUNNING, mirroring the RFID re-read
gating. Both buttons enabled when permission is granted; the printer
no-ops gracefully if there's nothing to do (matches BambuStudio).
Dual-extruder H2D Ext-R support is the trickier piece. The existing
ams_load_filament(254) capture came from a single-extruder printer
and used slot_id=254, curr/tar=-1. Captured the Ext-R command from
BambuStudio fresh: it sends ams_id=255, slot_id=0 (the right
extruder index, NOT a slot index), target=255, and curr/tar = the
actual right-nozzle temp (read from state.temperatures["nozzle_2"],
falling back to 215 °C if cold so the printer doesn't reject the
command on a nonsensical temp). Added that as a new branch in
ams_load_filament; the existing tray_id=254 branch is preserved
verbatim — no risk of regression on single-external setups.
P1S 01.10.00.00 (and similar firmware revisions) only echo the .3mf
filename in print.gcode_file, dropping the Metadata/plate_N.gcode path.
The /cover route's regex falls back to plate 1 — and the printer card
shows the wrong plate's thumbnail on multi-plate prints.
Resolution order in the new resolve_plate_id() helper (used by both
the status route's current_plate_id and /cover):
1. The plate Bambuddy dispatched. start_print() now records
(dispatched_plate_id, dispatched_subtask) on PrinterState; the
subtask check rejects stale records from a previous Bambuddy
dispatch bleeding into a Studio-direct print on the same project.
2. plate_(\d+)\.gcode regex on state.gcode_file (existing behaviour
for firmware that does include the path).
3. After download, scan the 3MF for a unique Metadata/plate_*.gcode —
covers per-plate archives sliced separately in Studio without a
Bambuddy dispatch record.
4. Default to plate 1.
Cover-byte cache key simplified to (subtask_name, view_key) now that
plate resolution is late-bound. clear_cover_cache() already fires on
every print start, so re-dispatches with a different plate always
fetch a fresh thumbnail.
Bambuddy-dispatched prints additionally register the local archive
3MF in the cover cache at dispatch time, so /cover reads straight
from the archive directory and doesn't refetch the file over FTP
from a printer whose FTP server is busy serving the active print.
Coverage: 5 unit tests for resolve_plate_id, 4 unit tests for the
dispatch record on start_print, 2 integration tests for the cover
route (dispatch wins over plate-1 default; 3MF-scan fallback for
per-plate archive without dispatch record).
The FTS routes any AMS slot to either extruder, so AMS info reports
bits 8-11 = 0xE (uninitialized) and ams_extruder_map ends up empty.
The print modal's per-nozzle dropdown filter then hides every loaded
slot, leaving the user with an empty filament dropdown.
Detection: parse print.device.fila_switch from MQTT push_status into a
new FilaSwitchState dataclass on PrinterState; surface it through the
GET /printers/{id}/status response as a nullable FilaSwitchResponse.
Frontend: useFilamentMapping and FilamentMapping skip the per-extruder
filter when fila_switch.installed is true. Slots currently fed into a
track display an [L]/[R] routing badge in the dropdown so the user
can see where the FTS is currently routing them.
Tests: 4 backend unit (TestFilamentTrackSwitchDetection), 2 backend
integration (status route), 2 hook regression, 2 component regression.
Three bugs that surfaced together while debugging an H2D cancel:
1. Cancelling a print stamped failure_reason="Layer shift" in archives
AND left the printer card stuck on "1 problem" forever. Four causes:
(a) POST /printers/{id}/print/stop never set the user-stopped flag, so
on_print_complete couldn't override "failed" -> "cancelled".
(b) HMS-derived failure_reason heuristic mapped any module-0x0C HMS to
"Layer shift". Module 0x0C is "Motion Controller" broadly (includes
cameras, markers, AND the cancel-sequence echo 0C00_001B). Real
layer-shift codes live in module 0x03. Same false-positive class
existed for "Filament runout" (any 0x07) and "Clogged nozzle" (any
0x05). Replaced with a 23-code curated short-code map; unknowns
leave failure_reason=None.
(c) Cancel-echo HMS codes (0300_400C "The task was canceled.",
0500_400E "Printing was cancelled.") were polluting state.hms_errors
via both the hms[] and print_error parse paths. Filter them at
parse time so the frontend never sees them.
(d) Frontend bucketed gcode_state="FAILED" as a problem unconditionally.
Real failures attach an HMS error; user-cancels don't — so FAILED-
without-HMS now buckets as "finished" and only escalates to "error"
when there's an active known HMS.
2. logs/bambuddy.log was silently dropping records from named child
loggers. TraceIDFilter was attached to root_logger, but Python's
logging only invokes a Logger's filters on records originating at that
logger — propagated child-logger records skipped it, formatter raised
KeyError, handler.handleError dropped the record. Moved the filter
from root_logger.addFilter() to handler.addFilter() on each handler,
matching the filter's own docstring guidance.
derive_failure_reason() extracted as a pure function for testability.
status="cancelled" now symmetrically yields "User cancelled" alongside
"aborted".
20 regression tests across:
- backend/tests/unit/test_failure_reason_derivation.py (11)
- backend/tests/unit/services/test_bambu_mqtt.py::TestHMSUserActionFiltering (4)
- backend/tests/unit/test_trace.py::TestFilterMustBeAttachedToHandlerNotLogger (1)
- frontend/src/__tests__/pages/PrintersPageBucketing.test.ts (5; includes
the H2D-cancel-echo "FAILED + only unknown HMS" case)
When two printers were running different plates of the same multi-plate
3MF, the Printers page cards displayed the same file name on both and
there was no way to tell them apart. The Queue view already had this
information by cross-referencing the archive's plate list; the card
didn't have the linkage.
Expose `current_archive_id` (resolved by matching the MQTT `subtask_id`
against `PrintArchive.subtask_id` — the bridge introduced in #972 for
restart-resume) and `current_plate_id` (parsed from `gcode_file` by a
new shared `parse_plate_id` helper) on the status endpoint. The helper
is also called from the WebSocket push path so plate transitions
reflect within 100 ms instead of waiting 30 s for the next REST poll;
the archive id itself stays REST-only since it's stable for the life
of a print and shouldn't make the push path touch the DB.
The card fetches plate metadata via the same `api.getArchivePlates()`
call QueuePage uses — shared React Query cache keeps it cheap across
polls — and renders the actual plate name (or a "Plate N" fallback)
only when `is_multi_plate` is true. Single-plate prints stay clean.
Falls back to the previous `plate_N.gcode` regex path when there's no
archive linkage (e.g. prints started directly from the printer LCD).
Tests cover the plate-id extraction across Bambu Studio path shapes
(backend parse_plate_id, printer_state_to_dict wiring) and the label
override precedence in formatPrintName (frontend).
After configuring an AMS-HT slot with a custom cloud preset, the slot
card and Configure modal kept showing "Generic PLA" even though the
printer and slicer had the correct preset. The `/slot-presets` response
keyed HT entries at `ams_id * 4 + tray_id = 512`, but frontend lookups
used `ams_id` directly (128 on PrintersPage via getGlobalTrayId, 64 on
SpoolBuddy via a one-off formula). All three agreed for regular AMS, so
the mismatch only surfaced on HT — the saved preset never reached the
UI and the render fell through to `tray.tray_type`.
Backend now keys via a helper that mirrors frontend `getGlobalTrayId`.
SpoolBuddy's AMS page switches to the shared helper. Regression test
covers regular, HT, and external slot keys.
Critical safety fix. The bed-jog dialog's "Home Z" button sent a bare
`G28 Z` over gcode_line. On Bambu printers where the Z endstop is at
the top (bed moves UP into it — H2C, H2D, H2S, X1 family), `G28 Z`
skips the toolhead-park step that a full `G28` runs first, so the bed
rises at full speed with nothing getting out of the way. The reporter
only escaped damage because the toolhead happened to be parked on the
purge chute.
The /printers/{id}/home-axes endpoint and BambuClient.home_axes() now
always send bare `G28` regardless of the axes argument, triggering the
firmware's safe multi-step routine (park toolhead → home XY → home Z).
The axes argument is kept for API compat but ignored; invalid values
still return 400.
Frontend retitles the button "Auto Home" and updates the dialog copy
in all 7 locales so users aren't surprised when X/Y motion happens
before Z. Parameterized regression test asserts z/xy/all all produce
bare G28.