Bed levelling, flow calibration, and nozzle-offset calibration were on/off
only, so the sole way to run bed levelling was to force a full level before
every print. Bambu Studio has always offered a third "Auto" state that lets
the printer skip the calibration when it was done recently -- the state most
users actually want. Make these three options tri-state (off/on/auto),
defaulting to auto, and leave vibration/layer-inspect/timelapse as on/off
(Bambu Studio exposes no auto for those).
Wire encoding follows Bambu Studio's source exactly: each option sends a JSON
bool (true only for "on") plus a companion int -- off=0, on=1, auto=2. The
bool fields stay booleans (the #1478 H2S regression); only the companion int
widened from {0,1} to {0,1,2}. #1721's observation that stage 8/39 stays
queued when sending 2 is the auto contract (queued, skipped at runtime if
recent), not a broken "off".
- schemas: TriState = Literal[off/on/auto] with a BeforeValidator coercing
legacy bool / 0-1 / true-false so old clients and un-migrated rows validate
- model + migration: boolean columns -> String; SQLite via column affinity +
data backfill, PostgreSQL via ALTER COLUMN TYPE guarded on information_schema
(verified on both dialects); settings rows normalised true/false -> on/off
- MQTT: start_print takes the tri-state strings and emits the paired bool+int
- Virtual Printer: reconstructs the slicer's auto/on/off from the int companion
(auto_bed_leveling / extrude_cali_flag) in both capture paths
- frontend: CalibrationMode type; off/auto/on segmented controls in the print
dialog, queue bulk-edit, and Settings -> Workflow; calibrationMode_* strings
in all 11 locales
A print queued from a specific plate of a multi-plate 3MF showed as Plate 1
in Print History after cancellation: the archive derives its plate from the
filename, but a whole multi-plate 3MF uploads under one name with no plate
suffix, so the parser defaulted to plate 1 and nothing copied the queue
item's plate_id onto the archive (which had no plate field).
Add a nullable print_archives.plate_id, copy it from the queue item at
dispatch (archive- and library-file paths), expose it in the archive API,
and render it in Print History. A startup backfill copies the plate onto
existing archives from their linked queue rows. Column add + backfill are
identical on SQLite and Postgres.
Also fix a related lifecycle bug: stopping a printing item while the printer
was offline left the linked archive stuck at "printing" (queue row
cancelled, but no MQTT completion ever arrives to reconcile the archive).
The offline-stop path now closes the archive out directly; the online path
still defers to the MQTT completion event.