An end-of-print auto-off on a plug that powers a filter fan marked the linked
printer offline and forced its state to "unknown". The mark was unrecoverable:
connected heals on the next MQTT message but state does not (only frames
carrying gcode_state rewrite it, and steady-state push_status frames are
partial), so the printer stayed "unknown" until a manual Force Refresh and the
queue never dispatched to it again.
The offline mark is now an explicit presumption: mark_power_off records the
state it overwrites and _on_message undoes it as soon as the printer sends
another report on its own topic, since inbound traffic proves the power was
never cut. A reconnect discards the saved state, so a genuine power cut is
unaffected. Each plug also gains a controls_printer_power flag (default true,
backfilled) that gates all five power-off paths, and the queue's power-on step
now picks the flagged plug instead of whichever linked plug came first.
Bed levelling, flow calibration, and nozzle-offset calibration were on/off
only, so the sole way to run bed levelling was to force a full level before
every print. Bambu Studio has always offered a third "Auto" state that lets
the printer skip the calibration when it was done recently -- the state most
users actually want. Make these three options tri-state (off/on/auto),
defaulting to auto, and leave vibration/layer-inspect/timelapse as on/off
(Bambu Studio exposes no auto for those).
Wire encoding follows Bambu Studio's source exactly: each option sends a JSON
bool (true only for "on") plus a companion int -- off=0, on=1, auto=2. The
bool fields stay booleans (the #1478 H2S regression); only the companion int
widened from {0,1} to {0,1,2}. #1721's observation that stage 8/39 stays
queued when sending 2 is the auto contract (queued, skipped at runtime if
recent), not a broken "off".
- schemas: TriState = Literal[off/on/auto] with a BeforeValidator coercing
legacy bool / 0-1 / true-false so old clients and un-migrated rows validate
- model + migration: boolean columns -> String; SQLite via column affinity +
data backfill, PostgreSQL via ALTER COLUMN TYPE guarded on information_schema
(verified on both dialects); settings rows normalised true/false -> on/off
- MQTT: start_print takes the tri-state strings and emits the paired bool+int
- Virtual Printer: reconstructs the slicer's auto/on/off from the int companion
(auto_bed_leveling / extrude_cali_flag) in both capture paths
- frontend: CalibrationMode type; off/auto/on segmented controls in the print
dialog, queue bulk-edit, and Settings -> Workflow; calibrationMode_* strings
in all 11 locales
GET /printers/{id}/cover took its printer row via Depends(get_db), whose
yield-dependency session stays open for the whole request — including the
3MF cover download (up to 8 remote paths x retries with backoff, minutes
under FTP contention). One pooled connection sat idle-in-transaction the
entire time; on a large farm a wall of dashboards drained the pool. The
route now fetches the printer in a short-lived async_session() and releases
the connection before the download (expire_on_commit=False keeps printer.*
readable). Pinned by a signature-inspection guard that fails if get_db is
ever re-added.
fix(print-start): release the DB connection across plate detection and 3MF download (#2572)
on_print_start held one session from top to bottom of the handler, across
two slow I/O blocks that need no database: the plate-detection camera grab
and, on the new-archive path, the multi-path 3MF FTP download (its own
comments cite worst cases of tens of minutes). The connection sat idle-in-
transaction for both, once per starting print. It now commits at each
boundary — only read SELECTs have run on those paths (every write branch
returns earlier), so the commit persists nothing and simply returns the
connection to the pool for the I/O; the next query re-acquires, and
expire_on_commit=False keeps printer.* readable.
fix(startup): connect to printers concurrently so the API serves within seconds (#2572)
init_printer_connections awaited each printer's connection serially, and
connect_printer ends in a fixed 1s settle wait. The MQTT connect is non-
blocking (connect_async + loop_start), so that 1s x fleet size was pure
serial dead air the FastAPI lifespan blocked on before uvicorn began
serving — ~100s before port 8000 responded on a 93-printer farm. The
connections are now started with asyncio.gather, so the step takes ~1s
regardless of fleet size. return_exceptions=True isolates each result: one
unreachable printer no longer aborts the rest, or startup itself.
The reporter found what his P1S was doing, and it is in Bambu's P1 manual:
"P1S connected AMS drying functions may only be controlled from the P1S screen."
The firmware acks ams_filament_drying with result: success and then discards it,
which is why three commands on an idle printer left the AMS 2 Pro at dry_status 0.
No command can start a cycle on a P1, on any firmware, so don't offer one.
supports_drying() now excludes the P1 series outright, replacing the 01.08+ gate
carried since #292 — that version is when P1 firmware gained AMS 2 Pro support,
not remote drying, and it was never checked against a live P1. Both drying routes
refuse with a specific 400 instead of publishing a message the printer will drop;
queue and ambient auto-drying skip P1s via the same helper.
A new drying_screen_only flag keeps the control on the card, disabled, saying why
— a P1 owner needs to learn where to dry, not watch the button disappear. A cycle
started at the printer still shows with its countdown; only Stop goes away, since
a P1 ignores stop exactly as it ignores start.
Also corrects the wiki firmware matrix, which listed P1P/P1S as supported and
(separately) P2S/H2S/H2C as unsupported. 8 tests.
The print-queue "auto off after this job" trigger used a second, inline
auto-off implementation (main.py, print_scheduler.py, print_queue.py)
that hardcoded wait_for_cooldown(50C, 600s) — ignoring each plug's
configured off_delay_mode / off_delay_minutes / off_temp_threshold — and
ignored the return value, powering off on the 600s timeout regardless of
print state. A print that failed and was reprinted from the touchscreen
got its power cut mid-print. The inline tasks were also uncancellable, so
a reprint couldn't abort a pending off.
Consolidate all three into SmartPlugManager.schedule_off_after_queue_job,
which schedules via the plug's configured strategy (shared with
on_print_complete through _schedule_off_per_mode) and is cancellable via
_pending_off. Add printer_manager.is_print_active() and guard the actual
power-off in _delayed_off and _temp_based_off so no path cuts power on a
loaded print. Move the on_print_start cancellation ahead of the auto_on
gate so a reprint always aborts a pending off.
Bambu's per-tick AMS push carries only the dry_time countdown — the
filament name and target temperature the user chose are never echoed on
the wire. The AMS card had no source of truth for them and rendered the
bare "Drying · 11h 35m left". The badge now shows
"Drying · PETG @ 65°C · 11h 35m left", matching the cycle the user
actually started.
BambuMQTTClient caches {ams_id: {filament, temp}} on send_drying_command
(mode=1), clears on mode=0 and on the dry_time falling edge to 0 — the
same per-AMS edge detector that drives the smart-plug-after-drying
callback. PrinterManager.get_drying_targets exposes it, the four
printer_state_to_dict call sites thread it through, AMS schema gains
dry_target_temp + dry_filament, and routes/printers.py builds the same
fields into the manually-constructed AMSUnit response.
When no cached target exists (drying started in a previous backend
lifetime, or initiated outside Bambuddy), the badge falls back to the
first loaded tray's tray_type + RFID-recommended drying_temp — the
heuristic the popover already uses to seed defaults.
i18n: printers.drying.targetSummary = "{{filament}} @ {{temp}}°C" in
all 11 locales. Parity check 5356 leaves per locale.
Note: a user reported the H2D's own physical display still labels the
cycle by the loaded tray's filament (e.g. "PLA" instead of the
Bambuddy-requested "PETG"). The wire payload is correct end-to-end —
journalctl shows filament: "PETG" sent and result: success ACKed — and
the badge in Bambuddy's own UI now reflects what we actually sent,
independent of the firmware's display choice.
Continue Auto-Drying while a print is running on capable hardware.
New Settings > Print Queue > "Continue drying while printing" toggle
(default OFF). Extends _check_auto_drying in print_scheduler.py to
evaluate running printers when supports_drying_while_printing(model,
firmware) returns true. Strict allowlist verified per Bambu wiki
release notes for "Print While Drying" / "printing while filament is
drying": H2D 01.03.00.00+, H2C/H2S/P2S/H2D Pro 01.02.00.00+, X2D/A2L
01.01.00.00+, X1C 01.11.02.00+. P1*, A1, A1 Mini, X1 (non-C), X1E
intentionally excluded. Mid-print drying temperature is capped at
max(40, preset_temp - 5) to protect spools from heat damage inside the
hot enclosure during a print, matching Bambu's own "lower drying
temperature during printing" guidance.
Rotate-spool toggle in the drying popover is now disabled when any tray
in the targeted AMS has filament threaded into the feed tube
(tray.state === 11). The whole AMS rotates as one mechanism, so a
single loaded slot locks the entire unit. Previously the toggle was
always clickable and the firmware rejected with dry_sf_reason=[3]
(ConsumableAtAmsOutlet) after the click. The first cut keyed on the
printer-level tray_now but missed the H2D's typical post-print state
where tray_now resets to 255 while filament stays in the tube — the
per-tray state field reports it correctly. Submission also clamps
rotateTray off so a stale-true state from a previous AMS can't leak
through.
Backend: supports_drying_while_printing in printer_manager.py covers
display names and internal SSDP/MQTT codes (O1D, O1E/O2D, O1C/O1C2,
O1S, N6, BL-P001, N7, N9). New print_drying_enabled boolean in
settings schema. Frontend: toggle on SettingsPage, gate + clamp on
PrintersPage drying popover using existing amsData cache. i18n: 3 new
keys x 11 locales, no English fallback. Tests: 7 cases on the gate
matrix (TestSupportsDryingWhilePrinting), 4 cases on the scheduler
mid-print path (TestMidPrintDrying), 9 cases on the rotate gate state
transitions. Full backend pytest -n 30 green (4251/4251), ruff clean,
frontend npm run build clean, i18n parity 5355 leaves per locale.
First-attempt fix (d196cfc5) was wrong about the cause. Real root,
traced via @mkoreen's BAMBUDDY_VP_DUMP_WIRE capture + 2026-06-21
support bundle:
mqtt_server.py:1296 was passing the slicer's bare subtask_name
(e.g. "Model_Name") into on_print_command, which stashed under
that key. _add_to_print_queue looked up under file_path.name
(the FTP filename WITH extension, "Model_Name.gcode.3mf"). The
two strings never matched. pop returned None, the 2s wait fired
against a key the stash side never signaled, every captured
slicer field silently fell back to settings defaults.
Affected EVERY Bambu Studio "Send" upload across EVERY model —
not just H2C nozzle_mapping. bed_leveling / flow_cali /
vibration_cali / layer_inspect / timelapse from the original
#1403 capture have been silently ignored since BambuStudio
started splitting subtask_name (bare) from file (with extension).
Unit tests passed because fixtures called on_print_command with
file_path.name directly, bypassing the broken caller.
Fix in manager.py::on_print_command: derive
stash_key = data.get("file") or filename and use it for both
_slicer_print_options and the event lookup. filename
(subtask_name) still flows unchanged to _schedule_finish_release
— push_status echoes it back as gcode_file / subtask_name and
the slicer matches against its own subtask_name there, so
re-routing that path was a separate regression I caught and
reverted mid-audit.
Also: nozzles_info field was a wrong guess in d196cfc5 —
BambuStudio never sends it (confirmed via wire capture). Drop
the capture, dispatch, schema, kwarg, and route paths. DB
column stays nullable so old rows still load; nothing reads
or writes it.
Diagnostic: DEBUG log when _add_to_print_queue finds no slicer
options after the 2s wait, including the looked-up key and the
actual cache keys present. Future stash/lookup mismatches will
be obvious from a log line instead of needing a wire capture.
Behaviour change worth flagging: users on Bambu Studio whose
slicer-side bed-leveling / flow-cali / vibration-cali /
layer-inspect / timelapse differ from Bambuddy's
default-workflow settings will see their slicer choices
honored now instead of silently overridden. Restores #1403's
original intent.
BambuStudio's project_file MQTT command for O1C2 (the H2C dual-
nozzle-rack variant) carries nozzle_mapping (per-filament physical
nozzle position IDs) and nozzles_info (per-extruder rack metadata).
The VP intake was dropping both, so the H2C firmware fell back to
"last matching nozzle type" auto-pick and ignored the user's
slicer choice — every HF print landed on R2, every standard print
landed on R4.
Carry both fields through the VP intake → queue item → MQTT
dispatch path. New nullable TEXT columns on print_queue, non-
branched ALTER (matches ams_mapping / filament_overrides
precedent). Dual-nozzle gate at start_print() keeps the fields
off single-nozzle dispatches. Fail-open on malformed JSON —
firmware auto-picks, never worse than pre-fix.
Stamps both fields on every plate in the multi-plate Send All
loop (#1697 / #1188 precedent).
ams_mapping2 still handles H2D/X2D dual-extruder routing
unchanged; this fix is scoped to the O1C2 rack-swap mechanism.
Bambuddy's project_file MQTT payload hardcoded "nozzle_offset_cali": 2 (skip),
giving users on H2D / H2D Pro / H2C / X2D no way to control the same toggle
BambuStudio exposes. Critical for diamond-nozzle setups that must keep the
calibration off.
start_print() now takes a nozzle_offset_cali kwarg; the value is encoded as
1 (run) or 2 (skip) and gated on is_dual_nozzle so single-nozzle machines
always send 2 even if a stale flag arrives. The kwarg threads through
printer_manager, both background_dispatch sites, and print_scheduler so
every dispatch path respects the per-item setting.
print_queue gains a nozzle_offset_cali column (DEFAULT TRUE, is_sqlite()
branch for Postgres BOOLEAN). Settings default key default_nozzle_offset_cali
defaults to TRUE to match BambuStudio. Schemas updated across print_queue,
library FilePrintRequest, archive ReprintRequest, settings.
PrintModal renders the new toggle only when the selected printer is dual-
nozzle (printer-mode: nozzle_count===2; model-mode: DUAL_NOZZLE_MODELS).
SettingsPage default-print-options row + QueuePage bulk-edit tri-state both
hide unless any registered printer is dual-nozzle. Labels reuse the existing
settings.default* keys so the only new i18n strings are
settings.defaultNozzleOffsetCali / Desc and queue.bulkEdit.nozzleOffsetCali
- real translations in all 11 locales.
H2C was in _DRYING_UNSUPPORTED_MODELS. Move to _DRYING_MIN_FIRMWARE
with the same 01.02.00.00 floor as H2S / P2S. Both SSDP model codes
the H2C advertises (O1C single-nozzle, O1C2 dual-nozzle) get the
same gate so supports_drying() fires correctly regardless of which
form is stored on the printer record.
The pre-insert MQTT probe added in 0.2.4.2 (b51598ea) had two bugs that
compounded on P1S firmware specifically:
1. Fixed 2-second sleep was too short. P1S broker + TLS handshake
routinely needs 3-5s to surface CONNACK on a cold MQTT session (same
firmware family with the documented "broker stops publishing but TCP
stays alive" quirk at bambu_mqtt.py:3181), so the probe falsely rejected
a printer that would have connected fine. H2C's broker is snappier and
cleared the 2s window without trouble — which is why the reporter's
H2C added without issue and only the P1S misbehaved.
2. client.disconnect() ran synchronously on the asyncio thread.
BambuMQTTClient.disconnect() ends in paho's loop_stop() which joins
the network thread; if that thread was still mid-TLS-handshake to the
slow P1S socket when teardown ran, the join blocked the asyncio thread
for as long as the handshake took to complete or fail. POST /printers
wedged, every other HTTP request queued behind it, Docker healthcheck
timed out — user-visible symptom: "the container hangs."
Fix:
- Replace the fixed sleep with a polling loop (8s budget, 200ms tick,
early-returns the moment state.connected flips True). Slow brokers
get the headroom they need; happy-path connects still finish in
~1-2s. Constants exposed as PROBE_TIMEOUT_SECONDS / PROBE_POLL_
INTERVAL_SECONDS class attributes so tests can dial them down.
- Move client.disconnect() to await asyncio.to_thread(...) so paho's
thread-join can never block the event loop.
The empty-card-report-prevention goal of the original probe stays
intact: a genuinely wrong access code still results in connected=False
after the 8s budget, the 400 with code=printer_connection_failed
still fires, the row is still never persisted.
Follow-up to the #1322 root fix. Reporter @RosdasHH traced the raw MQTT
payload and found that P1S and A1 Mini send only {"id": N} for a
physically empty slot — no state, no tray_type, no other fields. Without
that signal, the assign-spool path was firing one wasted MQTT publish per
click on a truly-empty slot (firmware dropped it silently, but still).
The AMS parser in printer_manager.py now detects the bare-tray shape and
promotes it to state=9 — the firmware's explicit "no spool" code — which
lets the existing state in {9, 10} short-circuit in the inventory route
apply automatically.
The detection is intentionally narrow:
len(tray) == 1 and "id" in tray and state is None
so the post-Reset-Slot A1 Mini BMCU case (populated payload with state=3
and tray_type="") has more than one key and stays unaffected — the #1322
root fix is preserved.
On A1 / A1 Mini, clicking the "Up" arrow on the printer-card bed-jog
control sent the nozzle straight into the build plate. Reporter
triggered it with the 50 mm step and crashed their nozzle.
Root cause: the bed-jog UI was designed against the X1 / P1 / H2 family
where the bed is the Z-axis and Bambu's firmware homes Z=0 at the top,
so G1 Z- raises the bed toward the toolhead (decreases the nozzle-bed
gap). The frontend maps "Up" to negative distance with that convention
in mind.
A1 / A1 Mini are bed-slingers: bed moves on Y, toolhead moves on X+Z,
firmware uses standard cartesian Z (Z+ = toolhead up). On those models
G1 Z-10 drives the toolhead DOWN 10 mm. There was no model
classification at the bed-jog code path, so every printer got the same
X1-convention G-code.
Fix: new is_bed_slinger(model) helper in printer_manager (sibling to
existing supports_chamber_temp / has_stg_cur_idle_bug, reuses the
already-defined A1_MODELS frozenset which covers display names and
internal codes N1 / N2S). The bed-jog route now inverts the signed
distance before emitting G-code when the printer model is in that set,
so UI "Up" semantics ("decrease nozzle-bed gap") stay consistent
regardless of which physical part moves. Frontend untouched, single
source of truth lives in the backend, keyed off the Printer.model
column. Route Query description and docstring updated to spell out the
new contract: distance is the gap adjustment, not the raw Z value.
P1S 01.10.00.00 (and similar firmware revisions) only echo the .3mf
filename in print.gcode_file, dropping the Metadata/plate_N.gcode path.
The /cover route's regex falls back to plate 1 — and the printer card
shows the wrong plate's thumbnail on multi-plate prints.
Resolution order in the new resolve_plate_id() helper (used by both
the status route's current_plate_id and /cover):
1. The plate Bambuddy dispatched. start_print() now records
(dispatched_plate_id, dispatched_subtask) on PrinterState; the
subtask check rejects stale records from a previous Bambuddy
dispatch bleeding into a Studio-direct print on the same project.
2. plate_(\d+)\.gcode regex on state.gcode_file (existing behaviour
for firmware that does include the path).
3. After download, scan the 3MF for a unique Metadata/plate_*.gcode —
covers per-plate archives sliced separately in Studio without a
Bambuddy dispatch record.
4. Default to plate 1.
Cover-byte cache key simplified to (subtask_name, view_key) now that
plate resolution is late-bound. clear_cover_cache() already fires on
every print start, so re-dispatches with a different plate always
fetch a fresh thumbnail.
Bambuddy-dispatched prints additionally register the local archive
3MF in the cover cache at dispatch time, so /cover reads straight
from the archive directory and doesn't refetch the file over FTP
from a printer whose FTP server is busy serving the active print.
Coverage: 5 unit tests for resolve_plate_id, 4 unit tests for the
dispatch record on start_print, 2 integration tests for the cover
route (dispatch wins over plate-1 default; 3MF-scan fallback for
per-plate archive without dispatch record).
Reshapes the embedded PrettyGCode viewer (landed in #963) into a focused
archive-preview tool, matching Bambuddy's data model instead of the
OctoPrint-style "connected-printer + library file picker" flow it shipped
with. Reached only from the Archives page 3D-preview button; URL
/gcode-viewer?archive=<id>[&plate=<N>].
Backend:
- /archives/{id}/gcode accepts ?plate=N and resolves the filename by
parsing the suffix as int, so zero-padded names like plate_01.gcode
are found when the plates endpoint reports index 1.
- /archives/{id}/plates gains top-level has_gcode: bool. Source-only
3MFs (PNG/JSON fallback path) surface the flag so the frontend can
skip the picker instead of sending the user into a dead viewer.
- printer_state_to_dict injects name + model into every WS snapshot so
consumers render proper labels on the initial tick without racing a
separate /printers fetch.
- /gcode-viewer (no trailing slash) dropped from the backend so reloads
fall through to the SPA catch-all and keep the layout shell; only
/gcode-viewer/ (trailing slash) and /gcode-viewer/<path> remain for
the iframe + static assets.
Frontend:
- PlatePickerModal shown only for multi-plate archives with sliced
gcode, grid layout with thumbnails matching the Re-print modal.
- Source-only archives show a noGcode toast instead of the empty
viewer.
- ArchivesPage navigate path swapped to /gcode-viewer?archive=<id> with
no trailing slash; GCodeViewerPage iframe forwards
window.location.search so the archive reference survives both the
initial navigate and a full-page reload.
- Viewer iframe's auth path: fetch intercept injects Bearer; a 401
redirects to / so the SPA handles login.
Viewer adapter:
- Stripped the printer selector, WebSocket subscription, library file
picker, tryAutoLoadPrintingFile, BAMBU_BED_SIZES, and updatePrinter-
Selector. The viewer no longer observes live printer state.
- Bed size derived from /archives/{id}/capabilities.build_volume
(extracted from the 3MF's printable_area/printable_height), so H2D,
H-family, and any future printer render on the correct bed without
a hardcoded map.
- loadArchiveById accepts a plate param; fetch intercept rewrites
__bambuddy_archive_<id>[_plate<N>] to /archives/<id>/gcode[?plate=N].
Nav + locale cleanup:
- Sidebar "GCode Viewer" nav entry removed (viewer is archive-scoped
now, not a destination page).
- 32 orphaned gcodeViewer locale keys deleted across all 8 locales.
- platePicker.{title, hint, plateLabel, objectCount, noGcode} keys
added in all 8 locales.
ArchivesPage: the now-unreachable ModelViewerModal render paths + its
showViewer state removed. ModelViewerModal itself stays — File Manager
still uses it for library file previews (plate picker + .3mf 3D model).
pre-commit:
- gcode_viewer/ excluded from trailing-whitespace + end-of-file-fixer
so vendored third-party JS libs don't drift away from upstream.
Incidental sweeps picked up by pre-commit and kept (unrelated but
benign):
- NotificationsPage.tsx: single trailing-whitespace line removed.
- spoolbuddy/scripts/pn5180_diag.py: dead `import gpiod` dropped —
the pn5180 driver module imported at line 27 does its own
`import gpiod` and `gpiod.Chip()` calls, so the diag script's
top-level import was never referenced.
Tests:
- 6 new cases in test_gcode_viewer.py for the backend plate / has_gcode
behaviour (plate=N resolution, zero-padded filenames, missing-plate
404, no-plate fallback, plate=0 rejection, has_gcode true/false).
- 3 new cases in test_printer_manager.py for name/model WS injection.
- PlatePickerModal.test.tsx — 6 frontend cases covering render,
plate-name composition, onSelect payload, backdrop close, and
thumbnail fallback.
PR #939 added the awaiting_plate_clear gate but stored it on
PrinterManager, not on PrinterState. printer_state_to_dict() — which
builds every WebSocket printer_status payload — never emitted the flag,
so the frontend's WS merge preserved the stale false value. The only
path that surfaced true was the 30s HTTP fallback poll, and incoming WS
ticks kept bumping React Query's dataUpdatedAt, pushing the refetch out
further on chatty printers.
Emit awaiting_plate_clear from printer_state_to_dict by reading
printer_manager.is_awaiting_plate_clear(printer_id) directly; returns
False when no id is passed. No frontend change needed — the existing WS
merge carries the flag end-to-end and the button now appears the instant
the printer transitions to FINISH.
Regression tests assert the WS dict always contains the key and surfaces
True when the manager has the flag set for that printer_id.
Affects every printer (A1/H2D/X1C) equally — transport-agnostic path.
When two printers were running different plates of the same multi-plate
3MF, the Printers page cards displayed the same file name on both and
there was no way to tell them apart. The Queue view already had this
information by cross-referencing the archive's plate list; the card
didn't have the linkage.
Expose `current_archive_id` (resolved by matching the MQTT `subtask_id`
against `PrintArchive.subtask_id` — the bridge introduced in #972 for
restart-resume) and `current_plate_id` (parsed from `gcode_file` by a
new shared `parse_plate_id` helper) on the status endpoint. The helper
is also called from the WebSocket push path so plate transitions
reflect within 100 ms instead of waiting 30 s for the next REST poll;
the archive id itself stays REST-only since it's stable for the life
of a print and shouldn't make the push path touch the DB.
The card fetches plate metadata via the same `api.getArchivePlates()`
call QueuePage uses — shared React Query cache keeps it cheap across
polls — and renders the actual plate name (or a "Plate N" fallback)
only when `is_multi_plate` is true. Single-plate prints stay clean.
Falls back to the previous `plate_N.gcode` regex path when there's no
archive linkage (e.g. prints started directly from the printer LCD).
Tests cover the plate-id extraction across Bambu Studio path shapes
(backend parse_plate_id, printer_state_to_dict wiring) and the label
override precedence in formatPrintName (frontend).
Move H2S from the drying-unsupported blocklist to the firmware-gated
list, requiring minimum firmware 01.02.00.00 (released end of March
2026). Both remote AMS drying and queue auto-drying now work on H2S.
Race condition in _update_state: dev mode probe released GIL via MQTT
publish between raw_data overwrite and vt_tray list restoration, letting
the event loop iterate over raw dict keys (strings) instead of spool
dicts. Affects A1, P1, and X1Plus firmware that don't send the fun field.
Fix: normalize vt_tray dict→list before raw_data assignment, restore
preserved fields before any GIL-releasing work, add defensive guard in
printer_state_to_dict.
Assigning or unassigning a spool now broadcasts a spool_assignment_changed
event to all connected WebSocket clients. The frontend handles this event
by invalidating the spool-assignments and slotPresets caches, so other
open tabs update automatically without a page reload.
Start, monitor, and stop drying sessions for AMS 2 Pro (n3f) and
AMS-HT (n3s) directly from the Printers page. Flame icon in AMS card
header opens a popover with filament-based temperature/duration presets
from BambuStudio. Live countdown status bar shows time remaining.
Backend: cache module_type from MQTT get_version, expose dry_time and
module_type in both WebSocket and REST paths, add supports_drying()
with firmware gating, add server-side guard on start_drying endpoint.
Frontend: drying button, popover with filament select + temp/duration
sliders, status bar, start/stop mutations. i18n for all 7 locales.
Supported: X1/X1C (fw 01.09+), P1P/P1S (fw 01.08+), H2D (fw 01.02.30+),
H2D Pro, X1E. Not supported: P2S, A1, A1 Mini, H2S, H2C.
Suppress SQL/aiosqlite debug noise (~90% log volume reduction), add
caller-traced PRINT COMMAND logging to start_print(), log scheduler
queue checks, tighten stale archive ilike match to exact match, and
warn on multiple queue items in "printing" status. Includes 18 new
unit tests.
Backend:
- Add dual external spool support for H2D (vt_tray as list: Ext-L/Ext-R)
- Add cloud filament ID map endpoint (/cloud/filament-id-map)
- Fix RFID spool data erased by periodic AMS updates (skip tag matcher
for RFID-tagged trays)
- Fix AMS slot config overwrites RFID spool state
- Fix K-profile selection corrupts existing profiles on X1C/P1S
- Resolve K-profiles filament name via cloud filament ID map
- Update print scheduler and usage tracker for dual external spools
Frontend:
- Add printer model filtering to ConfigureAmsSlotModal (cloud/local/builtin
presets filtered by @BBL model suffix and compatible_printers)
- Add pre-population for configured slots (preset, color, K-profile)
- Add K-Profiles view with accurate filament name resolution
- Internationalize all ConfigureAmsSlotModal strings (en/de/fr/it/ja — 21 keys)
- Add 5 new ConfigureAmsSlotModal tests (model filtering, pre-selection,
color pre-population, i18n)
- Update PrintersPage for dual external spool rendering
Docs:
- Update CHANGELOG, README, website features, and wiki AMS docs
- Remove 28 unused imports across 22 test files
- Prefix 4 unused local variables with _ in app code
(archives, bambu_mqtt, main) and remove 1 dead store
- Consolidate import/import-from in test_plate_detection.py
- Fix unreachable statement in test_archive_service.py
- Simplify redundant comparison in timelapse_processor.py
Resolves ~50 CodeQL py/unused-import, py/unused-local-variable,
py/import-and-import-from, py/unreachable-statement, and
py/redundant-comparison findings.
Track and display who performs key actions in Bambuddy:
- Archives: who uploaded each archive file
- Library: who uploaded each file in File Manager
- Queue: who added each print job to the queue
- Printers: who started the current print (reprint tracking)
Backend changes:
- Add created_by_id column to print_archives, library_files, print_queue tables
- Add database migrations for new columns (auto-run on startup)
- Update archive, library, and queue routes to capture current user
- Add current-print-user endpoint for printer reprint tracking
- Track reprint user in PrinterManager in-memory state
- Fix file uploads not sending auth headers (FormData requires explicit headers)
Frontend changes:
- Display username on archive cards, library files, queue items
- Show "Started by" on printer cards during active prints
- Add auth headers to all 12 FormData upload functions
- Update TypeScript types for user tracking fields
Tests:
- Add unit tests for PrinterManager user tracking methods (7 tests)
- Add integration tests for current-print-user endpoint (3 tests)
- Add integration tests for library file user tracking (3 tests)
Works when authentication is enabled; gracefully hidden when disabled.
Closes#206
Some A1/A1 Mini firmware versions incorrectly report stg_cur=0 (which
maps to "Printing") even when the printer is idle. This is a known
firmware bug also observed in the Home Assistant Bambu Lab integration.
- Add A1_MODELS constant listing affected model variants
- Add has_stg_cur_idle_bug() helper to identify affected models
- Update get_derived_status_name() to check gcode_state before stg_cur
for A1 models: if IDLE + stg_cur=0, return None to show "Idle"
- Fix only applies when all conditions match (A1 model + IDLE + stg_cur=0)
- Non-A1 printers and A1 printers without the bug are unaffected
Closes#168
Root Cause: P2S (and other newer models) may report their model as internal codes (e.g., "N7" for P2S) rather than display names in MQTT/SSDP responses. The camera code
only checked for display names like "P2S", causing it to incorrectly use the chamber image protocol (for A1/P1) instead of RTSP.
Internal Code Mapping:
BL-P001 → X1/X1C (RTSP)
C13 → X1E (RTSP)
O1D → H2D (RTSP)
O1C → H2C (RTSP)
O1S → H2S (RTSP)
O1E → H2D Pro (RTSP)
N7 → P2S (RTSP)
C11 → P1P (Chamber)
C12 → P1S (Chamber)
N2S → A1 (Chamber)
N1 → A1 Mini (Chamber)
Closes#127
Manually configure AMS slots for third-party or generic filaments:
1. Hover over an AMS slot on the printer card
2. Click the menu button (:material-dots-vertical:) that appears
3. Select **Configure Slot**
4. Choose a filament preset from your Bambu Studio cloud presets
5. Select a matching K profile (pressure advance calibration)
6. Optionally set a custom color using the color picker
7. Click **Configure Slot** to apply
**Color Picker Features:**
- Enter custom hex codes or color names (e.g., "brown", "FF8800")
- Live preview of selected color
- Expandable color picker in Configure AMS Slot modal:
- 8 basic colors shown by default
- 24 additional colors available via expand button
- Tests for ConfigureAmsSlotModal component
- Tests for AMS change callback
- Updated README with AMS slot configuration feature
- Wiki documentation for Configure AMS Slot feature
- Multi plate issue where plate names showed incorrect. #93
- Items from Queue end up as "source" files in archive. #107
- Added env variable support to change network port. #108
Docs -> https://wiki.bambuddy.cool/getting-started/docker/?h=port#custom-port
Fix Applied:
1. Added supports_chamber_temp() helper function that returns True only for X1/X1C/X1E, P2S, and H2 series
2. Modified printer_state_to_dict() to filter out chamber, chamber_target, chamber_heating from temperatures for unsupported models
3. Added model caching in PrinterManager so we can look up the model without a database query
4. Updated all callers (main.py, websocket.py) to pass the model
The chamber temperature widget will now simply not appear for P1S/P1P/A1/A1Mini printers since the temperatures.chamber field won't be sent to the frontend.
1. "Unknown Status (255)" bug
File: backend/app/services/printer_manager.py:291-293
Problem: A1/P1 printers send stg_cur=255 when idle (unlike X1 which uses -1). The code treated 255 as a valid stage number and returned "Unknown stage (255)".
Fix: Changed the condition from if state.stg_cur >= 0: to if 0 <= state.stg_cur < 255: so that 255 is now treated as "no calibration stage" (same as -1).
2. AMS humidity/temp displaced on mobile
File: frontend/src/pages/PrintersPage.tsx:1164-1212
Problem: The AMS row used a rigid horizontal flex layout that didn't adapt to narrow mobile screens, causing humidity/temperature indicators to be displaced.
Fix:
- Added flex-wrap to allow wrapping on very narrow screens
- Added ml-auto to humidity/temp section to keep it right-aligned
- Added max-w-[60px] sm:max-w-none to truncate long filament names on mobile
- Changed gap from fixed gap-3 to responsive gap-2 sm:gap-3
Tests Added
4 new unit tests for get_derived_status_name:
- test_stg_cur_255_returns_none - Verifies A1/P1 idle state
- test_stg_cur_negative_one_returns_none_when_idle - Verifies X1 idle state
- test_valid_stage_returns_name - Verifies valid stages work
- test_stg_cur_zero_returns_printing - Verifies printing state
All 382 tests pass.
Backend:
- pytest configuration with async support and coverage
- Unit tests for notification service (23 tests)
- Unit tests for smart plug manager (12 tests)
- Unit tests for archive service (16 tests)
- Integration tests for API endpoints
- Fix: notifications now send immediately (digest is summary only)
Frontend:
- Vitest configuration with jsdom and coverage
- MSW for API mocking
- Component tests for Toggle, Button, Card, ConfirmModal (77 tests)
- Test utilities with custom render wrapper
CI/CD:
- GitHub Actions workflow for automated testing
- Backend lint, unit tests, integration tests
- Frontend lint, type-check, unit tests, build