A queue item's "Any <model>" button labeled itself from the file's slice
metadata while the scheduler used the row's target_model, so an X1C-sliced
item targeting H2D showed "Any X1C" above "assign to first idle H2D". The
mismatch itself was created silently: sliced-for metadata loads async, and
switching to model mode before it arrived pre-selected the alphabetically
first model (H2D on a mixed farm), after which the model dropdown hid
itself. Nothing validated compatibility, so the scheduler would hand X1C
G-code to an H2D.
Frontend: never default the target silently, keep the dropdown visible in
model mode (incompatible models disabled), label from the actual target,
warn on mismatch, block submit when incompatible.
Backend: new GCODE_COMPAT_FAMILIES table (X1/X1C/X1E/P1P/P1S interchange;
everything else exact-match; missing metadata never blocks). Queue create
and update reject incompatible targets with 400; the scheduler holds back
pre-existing mismatched rows with an actionable waiting_reason instead of
dispatching them.
P1-series printers have a MicroSD slot but no reachable control to enable
"Store sent files on external storage": current P1 firmware (through
01.10.00.00) never publishes support_save_remote_print_file_to_storage, so
the Bambu Studio toggle never renders, and the P1S has no screen — leaving
store_to_sdcard stuck False with no way for the user to change it. The
external_storage check reported a permanently-unresolvable fail.
Add NO_REMOTE_STORAGE_TOGGLE_MODELS (P1S, P1P) + has_remote_storage_toggle(),
kept distinct from the no-slot NO_EXTERNAL_STORAGE_MODELS. When a model has a
slot but no reachable toggle and the option is off, the check now emits skip
with params reason=unsupported_model rather than fail, and overall no longer
escalates. A P1S reporting the option on still passes. Model-scoped and
default-open, so X1/P2S/H2 (where the fail is actionable) are unaffected; if
a future firmware surfaces the capability, drop the model and it reactivates.
The frontend DiagnosticChecklist renders a reason-specific message variant
(external_storage.skip_unsupported_model) so P1 users see an accurate
explanation instead of the generic "needs a live MQTT connection" skip text.
The fix propagates to the support-bundle diagnostic snapshot automatically.
Internal code N9 (from BambuStudio resources/profiles/BBL/machine/Bambu Lab A2L.json),
serial prefix 26A19 (5-char, same shape as H2C's late 31B8B). Capabilities from
Bambu's official A2L specs page: linear rail, single FDM extruder + integrated
cutter/plotter, no Ethernet (2.4 GHz Wi-Fi only), low-rate chamber camera on
port 6000.
The BambuStudio profile's use_double_extruder_default_texture: true flag
describes two TOOL HEADS (FDM + cutter), not dual filament extrusion — A2L
must NOT be classified as dual-nozzle or AMS routing will target the deputy
slot and firmware rejects with 07FF_8012.
Registry updates: printer_models.py, firmware_check.py, virtual_printer/manager.py,
virtual_printer/mqtt_server.py, PrintersPage.tsx, SpoolBuddyAmsPage.tsx.
12 new test cases in TestA2LModel pin every dimension.
A1 and A1 Mini ship without a MicroSD slot at all - there is no
firmware-side "Store sent files on external storage" toggle and the
slicers don't surface a slicer-side equivalent either. The connection
diagnostic was reading state.store_to_sdcard (home_flag bit 11), which
is never set on these models, so the check fell through to fail for
every A1-series user. Combined with the absent slicer UI it left users
thinking Bambuddy was wrong about a setting their hardware does not
have.
New NO_EXTERNAL_STORAGE_MODELS frozenset in utils/printer_models.py
enumerates A1, A1 Mini, and their internal codes (N1, N2S, A04, A11,
A12). has_external_storage() returns False for those, True for
everything else. Unknown models default to True so the check stays
active for future Bambu lineup additions - new no-slot models must be
added to the set explicitly.
The diagnostic now short-circuits to skip before reading
store_to_sdcard when printer.model is in the set. X1, P1, P2S, H2,
and X2D are unchanged - the bit-off -> fail signal is still the right
read for them.
The companion FTP-upload-timeout symptom in the same bug report (ftp
code 28 from BambuStudio when sending to the proxy VP) is a separate
Docker-bridge-mode networking constraint, not addressed here.
N1 and N2S were flipped relative to every other registry that names
them - firmware_check.py (N2S -> "a1"), virtual_printer/manager.py
(both the model map and the serial-prefix map: N2S -> 039 = A1,
N1 -> 030 = A1 Mini), and printer_manager.py A1_MODELS all agree on
N2S = A1, N1 = A1 Mini. Only printer_models.py had it backwards, so
any path that resolved an A1-family printer by internal code rather
than serial prefix would silently misclassify.
Also fixes the matching comments in LINEAR_RAIL_MODELS - cosmetic only
(both codes were already in the frozenset) but kept the file
self-consistent.
New TestA1SeriesModelIds regression test pins both directions so a
future re-flip fails loudly.
Reporter on an A1 Mini saw the AMS slot Configure dropdown render no
Bambu / Generic filament profiles, and saw the Profiles tab strip
A1 Mini results when filtering by that model. Bambu rolled out a
profile rename mid-2026: the @BBL <code> suffix on 106 cloud profiles
shifted from the long display form to a terse model code -- e.g.
"Bambu PLA Basic @BBL A1 Mini ..." is now
"Bambu PLA Basic @BBL A1M ...". User-authored profiles still use the
long form. Bambuddy's filters did a verbatim uppercase compare
("A1M" vs "A1 MINI"), so every renamed cloud profile silently
disappeared from the picker.
Centralize the alias check in slicerPrinterMatch.ts. New
PRINTER_MODEL_SUFFIX_ALIASES table maps "A1 Mini" <-> "A1M"
bidirectionally; exported matchesPrinterModelSuffix() does the
case-insensitive compare with the alias fallback. Two consumer
sites swap to the helper:
* ConfigureAmsSlotModal.tsx (Orca cloud and Bambu cloud filter
branches) -- the AMS slot picker, hit directly and reached from
SpoolBuddy's AMS page via mapModelCode(printer?.model)
* slicerPrinterMatch.ts:classifyByBambuName -- the SliceModal
Process / Filament compatibility check
Backend printer_models.py also gets a "Bambu Lab A1M" -> "A1 Mini"
entry so server-side 3MF model normalization stays consistent if a
3MF ever embeds the short form.
Kept the alias table narrow on purpose. Wide-net aliasing (e.g.
"X1" <-> "X1C") would silently collapse physically distinct
printers. When Bambu introduces the next rename, it is one new row
in the table -- /api/v1/cloud/settings is the place to grep, called
out in the source comment.
Five follow-up fixes to cross-printer re-slicing, all surfaced while
testing archive re-slices.
1. Re-sliced archive now records the printer it was sliced FOR.
slice_and_persist_as_archive copied sliced_for_model from the source
archive, so re-slicing X1C->H2D still showed "X1C sliced". Read it
from the freshly-sliced 3MF's parsed metadata instead, falling back
to the source only when absent.
2. Real slicer rejections are surfaced instead of silently masked.
_run_slicer_with_fallback retried with the 3MF's embedded settings on
any sidecar 5xx — including genuine content rejections (object off
the bed, incompatible filament temps), which "succeeded" only by
re-slicing for the source's original printer. A new
_slicer_rejection_message detects the slicer's own error string and
surfaces it as a 400; the embedded-settings fallback is kept only for
true CLI crashes.
3. A failed slice opens an error modal, not a 3s toast. The slicer's
reason is actionable and a toast hides it before it can be read. New
AlertModal (acknowledge-only); SliceJobTrackerContext shows it on a
failed job. New slice.failedTitle key in all 9 locales.
4. Sliced files no longer report "0 g" filament usage. The sidecar
doesn't always populate the X-Filament-Used-* headers;
ThreeMFParser._parse_gcode_header now also reads the slicer's own
"total filament weight/length" from the G-code header, and both
slice-persist paths fall back to it when the sidecar reports 0.
5. Nozzle-class re-slice guard. Re-slicing across the single-nozzle <->
dual-nozzle boundary (e.g. X1C -> H2D) fails BambuStudio's
multi-extruder validation; both slice routes now reject it up front
with a clear 400. The dual-nozzle model classification — previously
an inline tuple duplicated across start_print and the K-profile
routes — is centralized into DUAL_NOZZLE_MODELS / is_dual_nozzle_model
in printer_models.py, consumed by all three sites and the guard.
Full cross-nozzle-class re-slicing (dual-nozzle project_settings
reconciliation) remains separately tracked.
Tests: _slicer_rejection_message, _canonical_printer_model,
guard_nozzle_class_reslice, is_dual_nozzle_model, the G-code-header
filament parse, AlertModal, and end-to-end slice-API coverage including
an X1C-archive-to-H2D 400. Backend ruff + i18n parity clean; frontend
build clean.
The Bambu Lab X2D (launched April 2026, dual-nozzle, enclosed, hardened
steel rod gantry, AMS 2 Pro compatible) identifies itself as internal
model code N6 via SSDP/MQTT, and real serials begin with 20P9. None of
these identifiers existed in Bambuddy's registries, so the camera
service fell back to the chamber-image protocol on port 6000 (X2D
doesn't speak it), firmware-check logged "Unknown printer model: N6",
and the dual-nozzle K-profile paths — gated on the H2D serial prefix
"094" — would have treated X2D as single-nozzle.
Backend:
- Register N6 → X2D across every registry (PRINTER_MODEL_ID_MAP,
PRINTER_MODEL_MAP, STEEL_ROD_MODELS, ETHERNET_MODELS,
CHAMBER_TEMP_SUPPORTED_MODELS, firmware-check API keys + wiki path,
virtual-printer SSDP/product/serial tables, DB vp_model_fixes).
- supports_rtsp(): match the X2 display-name prefix and the N6 internal
code; camera now routes to RTSP on port 322.
- Dual-nozzle serial prefix check in bambu_mqtt.delete_kprofile and
kprofiles.set_kprofile broadened to ("094", "20P9") — X2D now takes
the H2D-style cali_idx in-place edit path.
- is_h2d model gate in bambu_mqtt.start_print extended with "X2D" so
timelapse / bed_leveling / flow_cali / vibration_cali / layer_inspect
are sent as integers and external-spool ams_id 254/255 routing is
preserved (H2D-style deputy-nozzle addressing).
X2D uses hardened steel rods like P2S — it is intentionally placed in
STEEL_ROD_MODELS, not CARBON_ROD_MODELS. A regression-guard test pins
the classification.
Frontend:
- mapModelCode in PrintersPage and SpoolBuddyAmsPage handle N6 and X2D.
- Enclosure-door badge and airduct-mode whitelists include X2D.
- MaintenancePage.getMaintenanceWikiUrl routes X2D to P2S wiki URLs for
steel-rod lubrication, belt tension, cold-pull, and PTFE tube
(exported to enable direct unit testing).
Tests:
- test_printer_models.py: TestX2DModel (10 assertions).
- test_bambu_mqtt.py: X2D in start_print ams_mapping and is_h2d gate;
TestDeleteKProfileDualNozzleDetection across H2D, X2D, P2S, X1C.
- MaintenancePageWikiUrls.test.tsx: 15 assertions covering X2D, P2S
regression, X1C/H2D/A1Mini regression, and model-name normalisation.
Docs:
- README: added X2 series to the supported printers table.
- CHANGELOG: new entry under 0.2.3b4 Fixed.
Credit to @krautech for the report and debug bundle, and to @legend813
for PR #989 which seeded most of the registry changes — rod-type
classification was corrected (steel, not carbon) and the dual-nozzle /
K-profile / is_h2d gaps were added on top.
home_flag bit 18 is set on all printers regardless of hardware,
causing the ethernet badge to appear on WiFi-only models (A1, P1P,
etc.). The previous fix removed the feature entirely, so ethernet
printers lost their badge too.
Now only trusts bit 18 on models with an ethernet port (X1C, X1E,
P1S, P2S, H2D, H2D Pro, H2C, H2S). WiFi-only models always show
the WiFi signal badge.
P2S uses hardened steel rods, not carbon fiber. Move P2S from
carbon rod classification to new steel_rod category with its own
"Lubricate Steel Rods" / "Clean Steel Rods" maintenance tasks.
The H2C dual nozzle variant reports model code O1C2 via MQTT, but only
O1C was recognized. This caused the camera to use the wrong protocol
(chamber image on port 6000 instead of RTSP on port 322), producing a
reconnect loop. Added O1C2 to all model ID maps across 8 files.
H2/A1 series have linear rails, not carbon rods. X1/P1/P2S have carbon
rods, not linear rails. Split rod-specific maintenance into model-aware
pairs: "Lubricate/Clean Carbon Rods" for X1/P1/P2S and "Lubricate/Clean
Linear Rails" for A1/H2. Added rod type classification to printer_models
and startup cleanup for stale/duplicate system maintenance types.
H2C was mapped to the "h2d" firmware API key, causing it to check
the H2D firmware page and offer H2D firmware for download. H2C has
its own separate firmware track (01.01.x.x vs H2D's 01.02.x.x).
Changed H2C to use its own "h2c" API key and added the reverse
mapping. Also added missing H2C (O1C) and H2S (O1S) entries to
the printer model ID and 3MF model name maps.
- Add H2D Pro option to printer model dropdowns (add/edit modals)
- Support both O1E and O2D internal codes for H2D Pro compatibility
- Add O2D to RTSP-capable and chamber temp supported models
- Add H2DPRO variant to firmware check mapping
- Add H2D Pro and X1E to bug report issue template
Closes#192